Environmentally friendly refrigeration systems for industrial use

Similar documents
Environmentally friendly systems for convenience stores

Use of transcritical CO 2 in industrial applications

investment in R&D, the commitment to - name.

CO2 TRANSCRITICAL BOOSTER SYSTEMS

System Design, Commissioning, Operation

TRENDS IN RETAIL INDUSTRY REFRIGERATION & REVIEW OF EUROSHOP 2017 EXHIBITION

SUBCRITICAL & TRANSCRITICAL SYSTEMS

Choose the winning team. Heat transfer technology for industrial cooling and air conditioning

Zero Superheat Control

Brazed Plate Heat Exchanger for CO Applications

compact BOOSTER RACK TRANSCRITICAL CO 2 Cooling capacity LT: from 2 to 130 kw Cooling capacity MT: from 20 to 300 kw

THE BIG FIVE NATURAL REFRIGERANTS IN DIFFERENT INDUSTRIAL APPLICATIONS. MAYEKAWA EUROPE S.A.,Leuvensesteenweg 605, 1930 Zaventem, Belgium

DeCO2ded: Understanding ROI on CO2 Refrigeration Systems

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

Transcritical CO2 Bottle Cooler Development

EN aquatech.piovan.com

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Commercial CO2 Refrigeration Systems. Guide for Subcritical and Transcritical CO2 Applications

Mechanical Systems Mechanical Systems

CO 2 transcritical FTE System Full Transcritical Efficiency

Process glycol chillers

Campbell Soup Company Extends Use of CO2 Systems Into Their Operations

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Refrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure.

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Air-Cooling Evaporators

GEA Blu chillers. GEA BluAstrum, GEA BluGenium, GEA BluAir: A new generation of compact ammonia chillers

Green economy with natural refrigerants

Welkom. Optimalisatie CO2 systemen m.b.v. ejecteur

Energy Efficiency Through Waste Heat Recovery. Heat Recovery Centrifugal Chillers and Templifier Water Heaters

DTI Kenneth Bank Madsen Global Application Expert Food Retail

Trends and Perspectives in Supermarket Refrigeration

Energy Efficiency Considerations in Refrigeration Systems

Saving the world and reducing energy costs with advanced CO 2 systems

Small Commercial Business Energy Audits. Recognizing and addressing the special requirements of the small business market segment.

Customers. The core of our innovation. Feeding&Conveying Drying Dosing Temperature Control Refrigeration. Granulation

Vicot Air Conditioning Co., Ltd. CONTENT

A refrigeration system for supermarkets using natural refrigerant CO 2

NATURAL REFRIGERANT SYSTEMS


BASE LEVEL AUDIT REQUIREMENTS REFRIGERATION SYSTEMS 1. SITE DATA COLLECTION. Business Name. Site physical address (Street, Suburb, City)

Atlas Copco. Oil-injected Rotary Screw Compressors Variable Speed Drive + (7-15 kw/10-20 hp)

July 2012 was a significant date for the HVAC and Refrigeration industry as it saw the introduction of the Carbon Tax and the HFC Levy.

REVERSIBLE R744 (CO 2 ) HEAT PUMPS APPLIED IN PUBLIC TRAINS

Chapter-8 Capacity Control of Refrigeration Systems

New Refrigerants & Selecting Capital Equipment

R&D ON HEAT PUMPS WITH NATURAL WORKING FLUIDS IN JAPAN

Technical Bulletin (TB-0037)

SEMI-HERMETIC SCREW COMPRESSORS

AZ(P)Y1 SERIES. Johnson Controls - Hitachi Air Conditioning AIR COOLED SCREW TYPE-WATER CHILLERS. R134a. Manufactured by:

DEMONSTRATION OF ADVANCED INTEGRATED HVAC&R SYSTEMS IN A LOBLAWS SUPERMARKET IN CANADA

Thermodynamics I. Refrigeration and Heat Pump Cycles

Commercial CO 2 Refrigeration Systems

THE INSTITUTE OF REFRIGERATION

REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar.

Refrigerants & Cooling in renovation buildings

Air-cooled chillers with single-screw compressor. Installation, operation and maintenance manual D - KIMAC EN. Original Instructions

1

Leadership, Innovation, Advanced Technology Synergise Here!

Energy Performance of Low Charge NH3 Systems in Practice. Stefan S. Jensen

New standard in compressed air treatment, providing Energy Savings up to 99%

Pack Calculation Pro. Users guide. Version Morten Juel Skovrup

Chillers CA Series: 35º 55º LCT CF Series: 35º 55º LCT CE Series: 35º 55º LCT CLH Series: 15º -15º LCT CLM Series: -10º -70º LCT

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-37 VSD+ (7-37 kw/10-50 hp)

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

commercial refrigeration products

Industrial cooling systems LT

Refrigeration Systems and Accessories

Chiller Centralised cooling plants Energy management. Perfect Cooling

Energy consumption storage facilities examined in ICE-E

Parilla Thermal Storage Project Case Study. May Page 1 of 11

Scroll Water Cooled Chiller

AIR COOLED CONDENSING UNITS

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice.

HYDROCARBONS, HEAT PUMP, HOME LAUNDRY DRYER: ENVIRONMENT FRIENDLY APPLIANCE

FACT SHEET 6 Transport Refrigeration

Aircooled Units. AirPLUS Aircooled scroll chiller. Freecooling options: liquid control. Freecooling options: fans control. Noise \\ Efficiency options

recooler HP EQKR HEAT PUMP

Technical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview

Global Solutions for Ammonia Industrial Refrigeration

R717 ROMANIAN REFRIGERATION SYSTEMS ANALYSIS Professor Gratiela-Maria TARLEA, Ph.D

NEW SECTION: ROTARY HEAT EXCHANGER WITH A HEAT PUMP Effective and smart!

The High-efficiency Water-cooled Chiller "H series"

HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE -

Emerson R290 Solutions for Commercial Refrigeration Applications

FACT SHEET 9 Large Air-Conditioning (air-to-air)

NEOSYS. AIR TO WATER LIQUID CHILLER kw. AIR TO WATER HEAT PUMP kw. lennoxemea.com

MSRW MINI SERIES. Modular Water Cooled Scroll Chiller MSRW075 MSRW085 Nominal Capacity 73 to 1312 kw(r) Issue: 2.0 Date 07/08

Comparison Ammonia / Secondary Refrigerant System against Direct Evaporation of HCFCs /HFCs

BOGE AIR. THE AIR TO WORK. Refrigerant Dryers RA Series

CO2 Supermarket System

PS & GPS SERIES PARALLEL RACK REFRIGERATION SYSTEMS

Refrigeration Compressed Air Dryer Boreas Variopulse

EWAT-B. Multi scroll chiller with R-32 refrigerant. First air cooled chiller with environmental friendly R-32 refrigerant

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-75 VSD+ (7-75 kw/ hp)

TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal

Why to decide on a Rotorcomp compact unit screw compressor

Ammonia. Background on ammonia as a refrigerant

H4T R410A. refrigerant

Transcription:

compindustri Environmentally friendly refrigeration systems for industrial use CO ² refrigeration systems of the future

GENERAL INFORMATION compindustri More than 10 years of development of refrigeration systems using CO ² as refrigerant combined with more than 2400 systems in operation, have positioned Advansor as the world s largest manufacturer of transcritical CO ² refrigeration systems. The systems combine a number of features that ensure reliability, optimal temperature control, and low operational costs. Choosing a product from the compindustri series, provides the end user with the most reliable and energy-efficient CO ² refrigeration system on the market. - Environmentally friendly refrigeration systems for commercial refrigeration and air conditioning - Based on more than 10 years of extensive development and experience - Reliable and energy-efficient systems - More than 2400 units installed Why use CO ²? compindustri units from Advansor only use one single refrigerant - CO ². CO ² is neither flammable nor toxic, making it an attractive refrigerant, both in terms of production, installation and operation of the system. CO ² meets all Danish and international requirements for refrigerants, present and future. By selecting a compindustri Advansor unit, neither the installer nor the end user need worry about new laws and taxes. Why choose a product from the compindustri series? There are many reasons for choosing a compindustri product. All units from Advansor are made with careful attention to detail, in order to achieve optimal, safe and service-friendly operation. All Advansor units are equipped with a complete oil control system to ensure effective oil return for all compressors. The units are equipped with an efficient oil separator, which ensures that as much oil as possible is returned to the oil reservoir from which the oil is automatically distributed to the compressors that have a low oil level. The entire oil system is regulated by the compressor controller. To ensure a good and stable superheating of the suction gas, Advansor has developed a patented system with an internal suction gas heat exchanger that ensures that no liquid will return to the LT compressors. By default, a suction accumulator is mounted on the LT suction line. In the MT suction pipe, superheating is controlled automatically by temperature sensors that continuously measure the suction gas temperature. At low superheat, hot gas will be blown into the suction pipe for optimum superheat. By customer choice, a suction accumulator for the MT section can also be mounted. To avoid excessive vibration of the unit, the compressors are equipped with vibration dampers and affixed to mounting plates that are welded to a solid frame made of steel profiles. Each unit has been designed in a 3D drawing CAD program, which ensures complete documentation of all components used in that unit. By designing all units in 3D prior to manufacturing, it is assured that all the valves and filters are easily accessible for servicing. In order to prevent refrigerant leakage during shut down, a higher design pressure can be selected for the low pressure side of the unit. All components necessary for increasing the design pressure are standard and are part of Advansors stock. During a power failure, the UPS (uninterruptible power supply), which is installed on the control panel, ensures that the high-pressure valve and the gas bypass valve are closed. The high pressure and the low pressure side of the unit are sepa- The advantages of compindustri - 100% environmentally friendly unit - Non-toxic, non-flammable refrigerant - Only one refrigerant - No greenhouse effect, GWP = 1 - No ozone-depleting potential - No zone classification needed - Compact construction - Low noise level - Low installation requirements - Easy to maintain - Low energy consumption - Low installation costs - Low maintenance costs - Future-proof solution rated from each other, thereby ensuring that the pressure levels are maintained and that the refrigerant in the unit does not leak during a longer outage. When the power returns, the unit will restart automatically. compindustri units are designed with standardized components, which is making it easy for customers to procure spare parts, in order to avoid long shut down periods. If the local procurement of spare parts is a problem, the components can be supplied directly from the Advansor warehouse. This also applies to older units.

MODELS MODELS Every unit is equipped with a liquid receiver at an intermediate pressure level. This basically functions as conventional liquid receiver. The receiver is designed for 80 bar which prevents the refrigerant from blowing off during system shut down. From the receiver, the liquid flows to the LT, MT and air conditioning evaporators where traditional expansion valves are used for direct injection (DX). All components of the control system for power-, oil-, and pressure-regulation are based on a control system that allows operation parameters to be monitored and controlled. This enables communication and supervision of the unit through a single network. Advansor products are adaptable to all common control systems that are available on the market. Included by default, one compressor is controlled by a frequency converter. This provides improved temperature control, especially on smaller systems. Advantages related to the installation When using an Advansor compindustri product, there will be only one type of refrigerant in the system. Because of this, a glycol circuit can be avoided. The installation can be made with small piping dimensions and it is possible to use either steel or copper pipes. The industrial cooling unit represents the latest technology based on natural refrigerants. It may be used in various applications, such as: By condensing CO ² directly in the condenser, considerable energy savings are achieved comparison with a solution using a glycol circuit and a dry cooler. - Freezing - Ice rinks - Cold storage and freezers - Catering and food processing - Fresh produce distribution terminals - Air conditioning of offices and production facilities Professional project management Advansor is an active partner in project work, and can supply all system components necessary for the unit. This ensures an optimal interaction between the mechanical components, condensers, evaporators, and control systems. In failure-safe applications, where temperature must be maintained without interruption, a number of identical systems can be installed so that more than one unit serves each room. Advansor always makes sure that the customer s specific needs are met. Description of a unit A compindustri unit is designed as a conventional single-stage system for direct expansion or as a two-stage booster system. LT and MT compressors are placed in the same refrigerant circuit. The units can combine multiple temperature levels while operating at optimal power consumption according to the capacities needed for cooling, freezing and air condition. It is also possible to utilize the discharge gas to achieve a heat recovery percentage of 30-50%. If you want 100% heat recovery, it is possible to bypass the gas cooler and thus exploit the full heating potential. Designed as a two-stage booster system, the discharge gas from the LT compressors flows directly into the suction line of the MT compressors and is afterwards compressed to a pressure level between 40-90 bar. The discharge gas then passes through a condenser/gas cooler installed outdoors, where it is cooled and partially condensed by heat exchange with ambient air. Exiting the condenser/gas cooler, the cooled gas/liquid returns through an expansion valve (high pressure valve) which dynamically maintains optimum operating pressure of the condenser in relation to the ambient air conditions. compindustri XL 5+3x3

MODEL OVERVIEW TECHNICAL SPECIFICATIONS Model: compindustri S 3x2 S/L 3x3 S/L 4x3 L 5x3 L 6x3 XL Model: T amb =36 C* L (3+1)x3 L (4+1)x3 L (5+1) x3 XL The heat recovery system # of Compressors, MT/LT MT capacity [kw] [at -10 C evaporation temperature and 32 C outdoor air temperature] LT capacity [kw] [at -35 C evaporation temperature and -10 C condensation temperature] Receiver volume* [L] Mechanical connections Liquid line(mt/lt) Suction line (MT) Suction line (LT) 3/2 3/3 4/3 5/3 6/3 70-140 100-150 130-200 180-240 240-360 20-35 25-40 40-60 40-70 40-70 1x130 1x130/2x170 1x130/2x170 2x170 2x170 2x 7/8 CU 2x 7/8 CU 3x 7/8 CU 3x 7/8 CU 4x 7/8 CU 2x 7/8 CU 2x 7/8 CU 3x 7/8 CU 3x 7/8 CU 4x 7/8 CU 1x 7/8 CU 2x 7/8 CU 2x 7/8 CU 2x 7/8 CU 2x 7/8 CU -/- <800 (MT only) <400 (LT only) 170 3+1/3 4+1/3 5+1/3 150-200 200-260 260-310 40-60 40-70 40-70 2x170 2x170 2 6/3 <800 (MT only) <400 (LT only) - Instead of rejecting the heat from the compressed gas to the atmosphere via the gas cooler, Advansor units include the option for choosing heat recovery. Recovered heat can be utilized for tap water or heating of air, or both if so desired. Due to the high temperature from compressed gas, it is possible to achieve temperatures in the 70-80 C range. The control of the heat recovery consists of four steps, depending on the heat requirement. Step 1: The 3-way valve is set so the discharge gas flows through the heat exchanger, and the water pump is started. The heat recovery has begun. Step 2: By gradually increasing the gas cooler pressure, the temperature of the discharge gas is increased. This is useful if a higher temperature and capacity on the water side is required. Step 3: The gas cooler fans are stopped. A minimal amount of heat is lost to the ambient air. Step 4: The 3-way valve is set so the gas cooler is bypassed. The heat recovery reaches 100%. Discharge line to the condenser Gas/liquid line from the condenser DN32 DN32/40 DN32/40 DN40 DN40 DN25 DN25/32 DN32/32 DN32 DN40 <DN40 DN32 DN40 DN40 DN32 DN32 DN32 Length [mm] 3500 3500/4400 3900/4400 4900 5900 5200 5500 6000 Width [mm] 780 780 780 780 780 800-1200 800 800 800 800-1200 Dp Height [mm] Weight [kg] 2100 2100 2100 2100 2100 1800 1900/2400 2000/2700 3200 3300 2200 2200 2200 2200 2500 3000 3500 2200 GAS COOLER/ CONDENSER By pass Valve Heat recovery M * The receiver can be supplied with extra-large capacity - ask Advansor Dimensions and weight of the unit can vary, depending on which options the customer selects *Advansor recommends parallel compressors if T amb >36 C For XL systems: compressor configuration and receiver capacities as per agreement By pass Valve Condenser M Heat recovery unit Model identification for the compindustri program: S 3 x 3 2R 60/60 Capacity range XS = Small capacity S = Small/medium capacity L = Medium/large capacity XL = customized solution - extra-large capacity Number of MT compressors Number of LT compressors Standard configuration of compindustri: - Semi-hermetic reciprocating compressors from leading manufactures - Control panel and electronic - First MT compressor - flow rate is regulated by variable frequency control - Standard design pressure for the unit: LT/MT/ receiver/hp: 30/52/80/120/130 bar - MT only/ LT only HP VALVE RECEIVER HP GBP GAS_BY_PASS EXPANSION VALVES OIL SEPERATOR MT COMPRESSORS MT EVAPORATORS Number of receivers 1R = 1 receiver 2R = 2 receivers XR = X receivers Design Pressure MT/LT 60/60 Bar 52/30 Bar 45/30 Bar Explanation of model for compindustri with parallel compressor: Number of parallel compressors S 3 +1x3 2R 60/60 Options: - Separate compressors and receiver modules, for easy on-site assembly - Heat recovery, with control system - 100% heat recovery by bypassing the gas cooler - Cabinet for installation outdoors - Extra-large receiver volume - Enhanced design pressure for the unit: LT/MT/ receiver/hp: 60/60/80/120bar - Systems to remote monitoring the unit - COP and energy meters - Chiller module 50-500 kw - Liquid cooled gas cooler EXPANSION VALVES Non-standard system solutions - Indirect system with glycol circuit - Pump system for flooded evaporators with pump separator and pumps LT COMPRESSORS LT EVAPORATORS

Advansor A / S Bautavej 1A DK-8210 Århus V T. +45 72 17 01 74 info@advansor.dk advansor.dk compindusti ENG ver. 2