ENA Engineering Recommendation G83 Issue

Similar documents
PRODUCED BY THE OPERATIONS DIRECTORATE OF ENERGY NETWORKS ASSOCIATION

Documentation guide to get your plant on the positive list (Category A1/A2)

EN50438 TEST REPORT SUMMARY. Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks

This EREC G98 draft uses text from a number of sources and is therefore colour coded to demonstrate where the words have come from as follows.

Report reference No...: 10TH0052_AS4777_+_ISR_3 Tested by (printed name and signature)...: Urs Seifert. Approved by (printed name and signature)...

Consumer Products Services Germany GmbH Türkheim Germany

Reyrolle Protection Devices. 7PG26 DAD High Impedance Current Relay. Answers for energy

Microgrid Fault Protection Based on Symmetrical and Differential Current Components

NEW CONNECTION Heat Pump Application Form C

Description (Data Point Name) Unit Size

DEIF A/S. Description of options. Option A4, Loss of mains protection package Automatic Gen-set Controller. Description of option

AO Annunciator Module

PAC1500Xi PORTABLE APPLIANCE CHECKER

CIRCUIT BREAKER FAIL PROTECTION

SENTINEL A - Fault Passage Indicator

02/11/2015

RQE Series Temperature Controllers

An introduction to... Sigma

VAMP 120 & 121. Arc flash detection units. Product picture

RS485 MODBUS Module 8AI

Protection Chain IQ-Sensor + Relaiy device T420

Table of Contents. Protective Relays

MGD Murco Gas Detector. Check / Calibration Procedure* 10 ASH (1)

02/11/2015

SENTINEL D - Fault Passage Monitoring

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for Infrastructure & Cities.

See product BS EN :2010

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

HD COMMUNICATOR. Features & Benefits: Unique continuous Redundant Routing capacity. Up to 20km reach on a single copper pair.

DDS-SSENSOR - INSTALLATION MANUAL. Installation Manual DDS-S SENSOR

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK


FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

RE-PR3-E-27 3-Phase Panel Mount 27kW

B SERIES ELECTRIC FURNACE

Operating Instructions. For. Alarm Control Module. Model SSR 500

DETECTION SYSTEMS. GCM Auto Alarm. Instruction Manual. GA0203P01 Rev. D

SPACEMOTION SERIES SMM 01

Eclipse Trilogy Flame Safeguard Modulating Sequences

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address...:

Universal controller for panel mounting Models CS6S, CS6H, CS6L

FCR 05, FCR 07. Power factor correction controller. User and service manual

Gasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225.

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR200-24S / OPR200-24R. Manual

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

Segment design & and Bus Diagnostics

Item Number Description Price. Accessories " Diesel/Water/Waste tank sender $ Battery temperature sensor $2.22

The test items passed the test specification(s).

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

Forced draught gas burner

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

RM2S 2 module housing (sequence and phase-failure/asymmetry voltages)

APPENDIX C APPROVAL PROCESS SUBMISSION FORMS. HCJ/LJ/B100841/JR Issue I April 16. Appendix C

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

Micro-DCI 4 Channel Indicator Totalizers Series 53IT5100

0-2 m/s Lo Alarm 0-6 m/s Hi Alarm Signal Stregth EASZ-12 Doppler Flow Switch Measuring Flow Worldwide

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

DS1286 Watchdog Timekeeper

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

1022 R/T Remote Monitor

hgate Product Catalog

Series 65 Product Guide MAN 3036

COMBY 4000 & 9000 STEAM CLEANER OPERATOR MANUAL

Forced draught gas burner

Operating Manual VMD420

- Check Test Methodology for Tumble Dryers Energy Label & Ecodesign -

Multiple Battery Cabinets Dual-Lite TRN. External Maintenance Switch Configuration Options. External Maintenance Switch Options

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

Safety Speed Monitoring

DUCT AIR HEATER WITH BUILT-IN CONTROLS. Installation & User Instructions. Stock Ref T T T3

APM110 LOW AIR VELOCITY ALARM

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

100A / 200A. Maximum Heating Load: Enclosure Type: NEMA 4

ISIS SAFETY SYSTEM Installation guide

MODEL: 47LCT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements. TÜV Rheinland Shanghai Co., Ltd.

DANFOSS OPTYMA PLUS INVERTER UNITS

Amendment Number 3 of BS how it might affect you

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

38-SDMS-01 SPECIFICATIONS FOR FAULT INDICATORS FOR UNDERGROUND DISTRIBUTION NETWORKS

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

nugate Product Catalog

PRODUCT CONFORMITY CERTIFICATE

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

Distributed Generation (greater than 10kW) Connecting to Vector s electricity network

10.6 Schedule of Accreditation

VoCALL - CFVCC5. Compact 5 Line Exchange Unit. Installation & Commissioning Manual

SPECIFICATION FOR GAPLESS METAL OXIDE DISTRIBUTION TYPE SURGE ARRESTERS WITH POLYMERIC HOUSING

GAISER 4000 STEAM CLEANER OPERATOR MANUAL

Carbon Monoxide Transmitter

GS100M Gas Detector. Technical Specification

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Transcription:

ENA Engineering Recommendation G83 Issue 2 2012 Type Verification Test Report Type Approval and manufacturer/supplier declaration of compliance with the requirements of Engineering Recommendation G83/2. SSEG Type reference number 2014001 SSEG Type System Supplier name Address GW1000 NS/GW1500 NS/GW2000 NS/GW2500 NS/GW3000 NS Jiangsu GoodWe ower Supply Technology Co.,Ltd. NO.189 Kun Lun Shan Road, Suzhou New District, Jiangsu,china Tel +86 512 6239 7998 Fax +86 512 6239 7972 E:mail service@goodwe.com.cn Web site http://www.goodwe.com.cn Connection Option Maximum rated capacity( use separate sheet if more than one connection option) 1 kw single phase 1.5 kw single phase 2 kw single phase 2.5 kw single phase 3 kw single phase SSEG manufacturer/supplier declaration. I certify on behalf of the company named above as a manufacturer/supplier of Small Scale Embedded Generators, that all products manufactured/supplied by the company with the above SSEG Type reference number will be manufactured and tested to ensure that they perform as stated in this Type Verification Test Report, prior to shipment to site and that no site modifications are required to ensure that the product meets all the requirements of G83/2. Signed Xie Jing On behalf of Huang min

ower Quality. Harmonics The requirement is specified in section 5.4.1, test procedure in Annex A or B 1.4.1 Harmonic SSEG rating per phase (rpp) At 45 55% of rated ouput Measured Value (MV) in kw Normalised Value (NV) in 100% of rated output Measured Value (MV) in kw Normalised Value (NV) in NV=MV*3.68/rpp Limit in BS EN61000 3 2 in 2nd 0.0313 0.0576 0.0871 0.1603 1.080 3rd 0.0546 0.1005 0.0384 0.0707 2.300 4th 0.0151 0.0278 0.0174 0.0320 0.430 5th 0.0702 0.1292 0.0218 0.0401 1.140 6th 0.0073 0.0134 0.0110 0.0202 0.300 7th 0.0629 0.1157 0.0226 0.0416 0.770 8th 0.0048 0.0088 0.0073 0.0134 0.230 9th 0.0509 0.0937 0.0222 0.0408 0.400 10th 0.0042 0.0077 0.0109 0.0201 0.184 11th 0.0429 0.0789 0.0214 0.0394 0.330 12th 0.0039 0.0072 0.0052 0.0096 0.153 13th 0.0242 0.0445 0.0200 0.0368 0.210 14th 0.0049 0.0090 0.0075 0.0138 0.131 15th 0.0124 0.0228 0.0201 0.0370 0.150 16th 0.0049 0.0090 0.0046 0.0085 0.115 17th 0.0108 0.0199 0.0139 0.0256 0.132 18th 0.0025 0.0046 0.0063 0.0116 0.102 19th 0.0127 0.0234 0.0123 0.0226 0.118 20th 0.0062 0.0114 0.0044 0.0081 0.092 Higher limit for odd harmonics 21 and above 21th 0.0136 0.0250 0.0156 0.0287 0.107 0.160 22th 0.0061 0.0112 0.0045 0.0083 0.084 23th 0.0130 0.0239 0.0136 0.0250 0.098 0.147 24th 0.0035 0.0064 0.0052 0.0096 0.077 25th 0.0109 0.0201 0.0159 0.0293 0.090 0.135 26th 0.0059 0.0109 0.0056 0.0103 0.071 27th 0.0132 0.0243 0.0162 0.0298 0.083 0.124 28th 0.0049 0.0090 0.0055 0.0101 0.066 29th 0.0108 0.0199 0.0133 0.0245 0.078 0.117 30th 0.0047 0.0086 0.0044 0.0081 0.061 31th 0.0067 0.0123 0.0073 0.0134 0.073 0.109 32th 0.0044 0.0081 0.0051 0.0094 0.058 33th 0.0088 0.0162 0.0107 0.0197 0.068 0.102 34th 0.0017 0.0031 0.0038 0.0070 0.054

35th 0.0086 0.0158 0.0073 0.0134 0.064 0.096 36th 0.0038 0.0070 0.0065 0.0120 0.051 37th 0.0073 0.0134 0.0099 0.0182 0.061 0.091 38th 0.0058 0.0107 0.0065 0.0120 0.048 39th 0.0082 0.0151 0.0077 0.0142 0.058 0.087 40th 0.0045 0.0083 0.0058 0.0107 0.046 Note: The higher limits for odd harmonics 21 and above are only allowable under certain conditions, if these higher limits are utilised please state the exemption used as detailed in part 6.2.3.4 of BS EN 61000 3 2 in the box below. Flicker The requirement is specified in section 5.4.2, test procedure in Annex A or B 1.4.3 Starting Stopping Running d max d c d (t) d max d c d (t) st lt 2 hours Measured values 0.00 0.00 0.00 0.00 0.00 0.00 0.08 0.09 Normalised to standard impedance and 3.68kW for multiple units 0.00 0.00 0.00 0.00 0.00 0.00 0.147 0.165 Limits set under BS EN 4% 3.3% 61000 3 2 3.3% 3.3% 4% 3.3% 1.0 0,65 500ms 500ms Test start date 2014.6.11 13:50 Test end date 2014.6.11 15:50 ower quality. DC injection The requirement is specified in section 5.5, test procedure in Annex A or B 1.4.4 Test level power 10% 55% 100% Recorded value 6.2mA 2.9mA 8.3 ma As % of rated AC current 0.062% 0.029% 0.07% Limit 0.25% 0.25% 0.25% Diagramm of permanent DC Injec 40 30 20 (ma) 10 0 10 20 30 40 1 11 21 31 41 51 61 71 81 91 101 111 121 131 141 151 161 171 DCI 0.25%Irated 0.25%Irated

ower Quality. ower factor The requirement is specified in section 5.6, test procedure in Annex A or B 1.4.2 216.2V 230V 253V Measured at three voltage levels and at full Measured output. Voltage to be maintained within 0.997 0.997 0.995 value ±1.5% of the stated level during the test. Limit >0.95 >0.95 >0.95 rotection. Frequency test The requirement is specified in section 5.3.1, test procedure in Annex A or B 1.3.3 Function Setting Trip test No test Frequency Time delay Frequency Time delay U/F stage 1 47.5Hz 20s 47.45 Hz 20.2s U/F stage 2 47Hz 0.5s 46.95Hz 0.814s O/F stage 1 51.5Hz 90s 51.55Hz 93.4s O/F stage 2 52Hz 0.5s 52.05Hz 0.886s Frequency / time 47.7Hz / 25s 47.2Hz / 19.98s 46.8Hz / 51.3Hz / 95s 51.8Hz / 89.98s 52.2Hz / Confirm no rotection. Voltage test The requirement is specified in section 5.3.1, test procedure in Annex A or B 1.3.2 Function Setting Trip test No test Voltage Time delay Voltage Time delay U/V stage 1 200.1V 2.5s 198.9 2.92 U/V stage 2 184V 0.5s 182.8 0.92 O/V stage 1 262.2V 1.0s 263.35 1.41s O/V stage 2 273.7V 0.5s 274.85 0.92 Voltage / time 204.1V / 3.5s 188V / 2.48s 180V / 258.2V 2.0s 269.7V 0.98s 277.7V Confirm no

rotection. Loss of Mains test inverters can be tested to BS EN 62116. Test ower and 33% 66% 100% 33% 66% 100% imbalance 5% Q 5% Q 5% +5% Q +5% Q +5% Trip time. Limit is 0.5s 0.193 s 0.262 s 0.238 s 0.178 s 0.432 s 0.226 s rotection. Frequency change, Stability test The requirement is specified in section 5.3.3, test procedure in Annex A or B 1.3.6 Start Change End Frequency Frequency Confirm no ositive Vector Shift 49.5Hz +9 degrees Negative Vector Shift 50.5Hz 9 degrees ositive Frequency drift 49.5Hz +0.19Hz/sec 51.5Hz Negative Frequency drift 50.5Hz 0.19Hz/sec 47.5Hz rotection. Re connection time The requirement is specified in section 5.3.4 Automatic Reconnection, test procedure in Annex A or B 1.3.5 Test should prove that the reconnection sequence starts after a minimum delay of 20 seconds for restoration of voltage and frequency to within the stage 1 settings of table 1. Voltage Time delay setting Measured delay time(s) 20s 47.05s Frequency Time delay setting Measured delay time(s) 20s 47.15s Confirmation that the SSEG does not re connect. Checks on no reconnection when voltage or frequency is brought to just outside stage 1 limits of table 1. At 266.2V At 196.1V At 47.4Hz At 51.6Hz no reconnection no reconnection no reconnection no reconnection

Short circuit Current Contribution The requirement is specified in section 5.7, test procedure in Annex A or B 1.4.6 For a directly coupled SSEG arameter Symbol Value Time after fault For a Inverter SSEG Volts eak Short Circuit current 20ms 10.2V 270mA Initial Value of aperiodic current Initial symmetrical short circuit current* Decaying (aperiodic) component of short circuit current* Reactance/Resistance Ratio of source* 100ms 10.5V 310mA 250ms 10.1V 510mA 500ms 11.2V 380mA Time to 680µs In seconds Self Monitoring Solid state Disconnection The requirement is specified in section 5.3.1, No specified test requirements. Not applicable since electro mechanical relays are used. N/A Additional comments GW1000 NS,GW1500 NS,GW2000 NS,GW2500 NS is similar to GW3000 NS in circuit and construction except for output rating of current and power. The test result can refer to GW3000 NS.