REFRIGERANT ON-VEHICLE INSPECTION AC 14

Similar documents
A/C-HEATER SYSTEM - MANUAL

AIR CONDITIONING SYSTEM

TROUBLESHOOTING GENERAL TROUBLESHOOTING PROBLEM PROBABLE CAUSE CORRECTIVE ACTION

ON-VEHICLE INSPECTION

Otherwise, you can continue reading the file on the following pages.

AIR CONDITIONING SYSTEM

SECTION 50 - CAB CLIMATE CONTROL

Vehicle Level Heating and Air Conditioning Description and Operation A/C System - Manual. A/C System - Manual

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration

INSTRUCTIONS RHS 700. Recovery, Recycling, Evacuation and Charging Station RHS 700


REFRIGERANT SYSTEM SERVICE WARNINGS

AUTOMOTIVE SPECIALIZATION (Air Conditioning and Heating) STUDENT GRADE RECORD Career & Technical Education

Motor Vehicle Air Conditioning (MVAC) System operation and the refrigerant cycle

HNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B COUNTER SHOWCASE MODEL SERVICE MANUAL HOSHIZAKI

Table of Contents. Service Procedures. Service Procedures. Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8)

Instructors: Contact information. Don Reynolds Doug McGee Factory Tech Support

MANUAL CONTROL HEATING, VENTILATION, AND AIR CONDITIONING SYSTEM

YC ON-OFF SERIES. Service Manual

Room Air Conditioner Service and Parts Manual

AXIAL HEATER TROUBLE SHOOTING GUIDE. Models: AX24 N/PV, AX24 N/PV LT, AX24 LP AX26 N/PV, AX26 N/PV LT, AX26 LP AX28 N/PV, AX28 N/PV NT, AX28 LP

Trouble Shooting Guide PWA, 3-phase (D10571)

Room Air Conditioner CP06 & CP08. Chill 115 Volts. Service & Parts Manual THE EXPERTS IN ROOM AIR CONDITIONING _02

Polar Air Dryer. Instructions Manual PDRCF PDRCF R E F R I G E R A T E D T Y P E C O M P R E S S E D A I R D R Y E R S

Cab Heater and Air Conditioner, Water-Valve Controlled 83.02

(PD[ $LU 'U\HU 5 ( ) 5, * ( 5 $ 7 ( ' 7 < 3 ( & ( 6 6 ( ' $, 5 ' 5 < ( 5 6 ('5&) ದ ('5&) Instructions Manual

Operation regulations must be strictly obeyed.

Beverage Air IMPORTANT

POWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings

442 Chapter 16. Figure 16-5 Gas leak detection

12 In Row. Installation Manual. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

Service Manual. Refrigerator. Model: HC-767WE. Features

Part 3 Troubleshooting

R410A. AIR CONDITIONER DUCT TYPE / ART Series OPERATING MANUAL. REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A.

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

HEATER & AIR CONDITIONING SYSTEM

Room Air Conditioner Service and Parts Manual

SERVICE MANUAL OFFICE PRO 36 SERIAL NUMBER FROM DECEMBER 2004 (1204) TO MARCH 2007 (0307)

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

AIR CONDITIONING SYSTEM

Room Air Conditioner EP08 & EP12. Chill 115 Volts-EP Volts-EP12. Service & Parts Manual THE EXPERTS IN ROOM AIR CONDITIONING

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Packaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS

DOLE REFRIGERATING COMPANY 1420 Higgs Road Lewisburg, Tennessee Phone (931)

Full Range Systems. Mokon Troubleshooting Guide Model 311. Process/Water Loop. Problem Possible Cause Corrective Measure. Process pump will not start

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

- 1 - Updated on 18 March, 2010

Room Air Conditioner SERVICE MANUAL MODEL : LW6013ERY3. CAUTION

- 1 - Updated on 18 March, 2010

Room Air Conditioner Service and Parts Manual

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Fig. 1 - Unit PHD4 and WPH4

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

2004 HVAC. Heating, Ventilation and Air Conditioning - Hummer H2. Fastener Tightening Specifications Specification Application

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

38ASB/CCARS240~600 (036~060) AIR-COOLED CONDENSING UNIT

HAIER REFRIGERATOR. Service Manual PART # RF HAIER AMERICA TRADING, LLC

Trouble Shooting Guide RAA, 1-phase (D3627)

WINDOW TYPE COOLING MODEL AKT7F AKT9F REVERSE CYCLE MODEL AKT7U AKT9U FUJITSU GENERAL LIMITED

Refrigerated Compressed Air Dryer

Trouble Shooting Guide PAA, 1-phase (D3731)

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

RPI Industries, Inc.

RM85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

INSTALLATION INSTRUCTIONS

Chapter 6. Do s & Don ts in Refrigeration & Air-Conditioning Servicing

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

A/C SYSTEM GENERAL SERVICING

Thru-the-Wall Series

RM85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Owner s Information Manual

Trouble Shooting Guide FAA, 3-phase (D3631)

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions

ASSIGNMENT OBJECTIVES

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

17 Interior Climate Control

HEATING AND AIR CONDITIONING

FAQs Air conditioning systems / Air conditioners

TABLE OF CONTENTS FOR YOUR SAFETY


UNIT MODEL/ POWER SUPPLY VOLTAGE VARIATION AMBIENT AIR ON CONDENSER

EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

HEATER & AIR CONDITIONING SYSTEM

SEA FROST BAITFREEZER 110-VOLT AIR-WATER Twin Valve

OWNER S MANUAL KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11

Owner s Manual SPLIT-TYPE ROOM AIR CONDITIONER

AIR CONDITIONING. CONfENfS. Page DESCRIPTION 1 SERVICE DIAGNOSIS 1 INSPECTION, TEST PROCEDURE AND DIAGNOSIS 4

CC Series VACUUM PUMPS

Table of Contents SAFETY FIRST. Owner s Manual. Safety Precautions Unit Specifications and Features Manual Operation (Without Remote)...

EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5

OPERATING INSTRUCTIONS

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3B54VA MXZ-4B71VA. English

Owners Manual Refrigerated Air Dryer MHT SERIES

Transcription:

14 REFRIGERANT ON-VEHICLE INSPECTION 1. INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET (a) This is a method to specify trouble areas by using a manifold gauge set. Read the manifold gauge pressure when the following conditions are established. Test conditions: Engine has been warmed up. All doors are fully open. A/C switch is ON. Engine is running at 1,500 rpm. Air inlet mode selector damper is set at recirculation. Temperature control switch is in MAX. COLD position. Blower speed control switch is in HI position. Air temperature at the air inlet is 30 to 35 C (86 to 95 F). Gauge readings (Reference) Pressure on low pressure side MPa (kgf/cm 2 ) 0.5 (5.0) Blower HI Zone 0.4 (4.0) 0.3 (3.0) 0.2 (2.0) 0.27 (2.75) 0.22 (2.24) 0.2 (2.03) 0.14 (1.4) 0.5 (5.0) 1.06 (10.8) 1.2 (12.2) Blower LO Zone 1.25 (12.7) 1.32 (13.5) 1.0 (10.0) 1.5 (15.0) 2.0 (20.0) Pressure on high pressure side MPa (kgf/cm 2 ) I030081E06

15 (1) When the volume is proper: Gauge reading: Low pressure side: 0.15 to 0.25 MPa (1.5 to 2.5 kgf/cm 2 ) High pressure side: 1.37 to 1.57 MPa (14 to 16 kgf/cm 2 ) (2) When there is moisture in the refrigeration system: E050573E02 Condition: Air conditioning system periodically repeats proper and improper function. I022117E08 During operation, pressure on low pressure side cycles between normal and vacuum Moisture in refrigeration system freezes at expansion valve orifice, causing temporary stop of cycle. However, when melted, normal state restored Drier overly saturated Moisture in refrigeration system freezes at expansion valve orifice and blocks circulation 1. Replace cooler drier 2. Remove moisture from cycle by repeatedly evacuating air 3. Supply appropriate volume of new (3) When cooling is insufficient: I022118E04 Pressure low on both low and high pressure Cooling performance insufficient Gas leakage from refrigeration system Insufficient Refrigerant leakage 1. Check for gas leakage and repair if necessary 2. Supply appropriate volume of new 3. If indicated pressure value close to 0 when connected to gauge, create vacuum after inspecting and repairing the location of leakage

16 (4) When the circulation of the is poor: I022119E04 Pressure low on both low and high pressure Frost exists on piping from condenser to A/C unit Refrigerant flow obstructed by dirt in condenser Condenser clogged Replace condenser (5) When the does not circulate: Condition: Air conditioning system does not function. (Sometimes it may function) I022121E05 Symptoms Probable Causes Diagnosis Corrective Actions Vacuum indicated on low pressure side, and extremely low pressure indicated on high pressure side Frost or condensation seen on piping on both of condenser or expansion valve Refrigerant flow obstructed by moisture or dirt in refrigeration system Refrigerant flow obstructed by gas leakage from expansion valve Refrigerant does not circulate 1. Check expansion valve 2. Clean expansion valve by blowing air 3. Replace condenser 4. Evacuate air and charge appropriate volume of new 5. For gas leakage from expansion valve, replace expansion valve (6) When the is overcharged or cooling of condenser is insufficient: I022121E06

17 Symptoms Probable Causes Diagnosis Corrective Actions Pressure extremely high on both low and high pressure Excessive Cooling performance of condenser insufficient Excessive Cooling performance of condenser insufficient 1. Clean condenser 2. Check condenser fan motor operation 3. If 1 and 2 normal, check the amount of and supply appropriate volume of (7) When there is air in the refrigeration system: Condition: Air conditioning system does not function. NOTE: These gauge indications occur when the refrigeration system opens and the is charged without vacuum purging. I022122E05 The low pressure piping too hot to touch Air in refrigeration system Air in refrigeration system Vacuum purging insufficient 1. Check whether compressor oil dirty or insufficient 2. Evacuate air and charge new (8) When the expansion valve malfunctions: Frost or condensation on piping on low pressure side Trouble in expansion valve Excessive in low pressure piping Expansion valve too wide open Replace expansion valve I022123E04 (9) When the compressor is defective: Condition: Air conditioning system does not function. I022124E04

18 Pressure extremely low on high pressure side Internal leakage in compressor Compression failure Leakage from damaged valve or broken sliding parts Repair or replace compressor