Signature Series Component

Similar documents
Signature Series Auto-Sync Output Module (CC1S)

SIGA-CC1 Single Input Signal Module Installation Sheet

Control Relay Modules

Booster Power Supply Manual

Print Specification. Publication. Instructions. Specific requirements. General requirements

Addressable Detectors & Bases

FIRE ALARM SYSTEM 1.1 GENERAL REQUIREMENTS

WORLD CLASS SOLUTIONS TO A UNIVERSAL CHALLENGE EST LIFE SAFETY PRODUCTS DETECTORS AND MODULES ... EDWARDS SYSTEMS TECHNOLOGY

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

io64 Intelligent Life Safety System

TECHNICAL DATA OBSOLETE

SC-6 Six Supervised Control Module

ANNUNCIATOR FIXED MODULE

Addressable NAC Output Module D327A

V-Series Life Safety Systems

SECTION ADDRESSABLE FIRE ALARM SYSTEM

MR-2602 Two Zone Fire Alarm Control Panel

Specification/ Data Sheet

CZ-6A Six Zone Interface Module

WINDOW & HVAC REPLACEMENT PEMBERTON TOWNSHIP BOE REGAN YOUNG ENGLAND BUTERA, PC PROJECT #5450E

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

LifeAlarm Fire Alarm Controls

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

PSN-1000 & PSN 1000(E) Installation Manual

good things in small packages

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description.

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

TrueAlert Addressable Notification Appliances

Addressable Fire Alarm Control Panel

Release Control Fire Alarm Systems

TrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description

MANUAL RESET ALARM RELEASE

MANUAL RESET ALARM RELEASE

Multiple Input and Output Modules

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

INSTALLATION GUIDE XR5FC AND XR5SL COMMERCIAL FIRE PANELS

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

Model 17A00 Expansion Enclosure

MODEL B2 INSTALLATION MANUAL

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

Remote Booster Power Supply Technical Reference Manual

EST3 Installation and Service Manual

LifeAlarm Fire Alarm Control Panels

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

MMF Six Zone Interface Module

FireShield Plus. GE Security. EST Life Safety & Communications Conventional Small Building Solutions. Conventional Fire Alarm Control Panels

VS1 Intelligent Life Safety System

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

Installation Instructions Model ABHW-4S

4100U City and Relay Cards Installation Instructions

IDP-Zone-6 Six Zone Interface Module

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

ECC-50/100C. Emergency Command Center

30.45 Electric Release PDRP-2001

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

TrueAlert Addressable Notification Appliances

1. POWERPATH Operation

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

TrueAlert Multi-Candela Notification Appliances

Remote NAC Power Supply D7038

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200

Table 1: dba Ratings for AMT Multitone Signal Typical Anechoic dba at 10 Feet per CAN/ULC S525-07

EST2. Installation and Service Manual P/N REV 07 REB 27FEB13

R Series Remote Annunciators and Expander Installation and Operation Guide

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

E-FSC. Conventional Fire Alarm Control Panels. Standard Features. Overview

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

Fire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION

TrueAlert Addressable Notification Appliances

TrueAlert Notification Appliances

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

INSPECTION AND TESTING FORM

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

Cookson Company 1901 South Litchfield Road Goodyear, AZ Phone:

FireSeeker Fire Alarm Control Panel Model FS-100 Installation, Operation, and Maintenance Manual

RELEASE DEVICE CONTROLS

Building Name: Our Lady of Sorrows Date: July 10, 2013

Conventional Fire Alarm Systems

TrueAlarm ES Analog Sensing

R-Series Remote Annunciators and Expanders Installation and Operation Guide

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

AND ARCHITECT SPECIFICATIONS

The MS-4412B/MS-4424B(E) FIRE ALARM CONTROL PANELS

F I R E G A R D D C EXTENDED PERFORMANCE RELEASE DEVICE SAFE A N D SECURE

109-B Concord Drive Casselberry, FL DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72. Owner s Address: Owner's Phone Number:

LiftMaster 300 Windsor Drive Oak Brook, IL LiftMaster.com

Multi-Application Peripherals and Accessories

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

SELECT-A-HORN/STROBE SERIES

Conventional Releasing Control Panel

Transcription:

Signature Series Component Installation Manual P/N 7097 Rev.0 06DEC99

DEVELOPED BY COPYRIGHT NOTICE Edwards Systems Technology 6 Parkland Drive Sarasota, FL (9) 79-00 Copyright 997-99 Edwards Systems Technology This manual and the products it describes are copyrighted by Edwards Systems Technology (EST). You may not reproduce, translate, transcribe, or transmit any part of this manual without express, written permission from EST. This manual contains proprietary information intended for distribution to authorized persons or companies for the sole purpose of conducting business with Edwards Systems Technology, Inc. If you distribute any information contained in this manual to unauthorized persons, you have violated all distributor agreements and we may take legal action. CREDTIS This manual was designed and written by EST Technical Services - Documentation Department, Sarasota. REVISION INFORMATION The last revisions to this manual were made 06DEC99.

Content -CTM City Tie Module SIGA-70(L) Fire Alarm Station SIGA-70P -Stage Fire Alarm Station SIGA-78 Double Action Fire Alarm Station SIGA-AB Detector Sounder Base SIGA-CC Single Input Signal Module SIGA-CC Dual Input Signal Module SIGA-CR Control Relay Module SIGA-CRR Control Relay Reversing Module SIGA-CT Single Input Module SIGA-CT Dual Input Module SIGA-DG Detector Guard SIGA-DGS Surface Adapter for use with the SIGA-DG Detector Guard SIGA-DH Duct Detector Housing Assembly SIGA-DMP Duct Mounting Plate SIGA-DTS Duct Detector Test Station SIGA-HFS Fixed-Temperature Heat Detector SIGA-HRS Fixed-Temperature/Rate-of-Rise Heat Detector SIGA-HRSI Grade Heat Detector SIGA-IB Detector Base SIGA-IB Detector Base SIGA-IM Isolator Module SIGA-IPHS(B) D Multisensor Smoke Detector SIGA-IS Ionization Smoke Detector SIGA-LED Remote LED Alarm Indicator SIGA-MAB Class A/B Input/Output Module SIGA-MB Transponder Mounting Bracket SIGA-MCC Single Input Signal Module SIGA-MCC Dual Input Signal Module SIGA-MCR Control Relay (Dry) Module SIGA-MCRR Control Reversing Relay Module SIGA-MCT Dual Input Module SIGA-MM Monitor Module SIGA-MP Mounting Plate SIGA-MP Mounting Plate SIGA-MPL Mounting Plate SIGA-PHS D Multisensor Smoke Detector SIGA-PS Photoelectric Smoke Detector SIGA-RB Detector Base SIGA-RB Detector Base SIGA-SB Detector Base SIGA-SB Detector Base SIGA-TS -inch Box Trim Skirt / Ring SIGA-UIOR Universal Input/Output Motherboard SIGA-UIO6(R) Universal Input/Output Motherboard SIGA-UM Universal Class A/B Module SIGA-WTM Waterflow/Tamper Module SIGI-7 Breakglass Station SIGI-IBS Detector Base Signature Series Component Installation Manual i

Important Information Limitation of liability This product has been designed to meet the requirements of NFPA Standard 7, 99 Edition; Underwriters Laboratories, Inc., Standard 86, 7th Edition; and Underwriters Laboratories of Canada, Inc., Standard ULC S7 Installation in accordance with this manual, applicable codes, and the instructions of the Authority Having Jurisdiction is mandatory. EST shall not under any circumstances be liable for any incidental or consequential damages arising from loss of property or other damages or losses owing to the failure of EST products beyond the cost of repair or replacement of any defective products. EST reserves the right to make product improvements and change product specifications at any time. While every precaution has been taken during the preparation of this manual to ensure the accuracy of its contents, EST assumes no responsibility for errors or omissions. FCC warning This equipment can generate and radiate radio frequency energy. If this equipment is not installed in accordance with this manual, it may cause interference to radio communications. This equipment has been tested and found to comply within the limits for Class A computing devices pursuant to Subpart B of Part of the FCC Rules. These rules are designed to provide reasonable protection against such interference when this equipment is operated in a commercial environment. Operation of this equipment is likely to cause interference, in which case the user at his own expense, will be required to take whatever measures may be required to correct the interference. ii Signature Series Component Installation Manual

Document History Signature Series Component Installation Manual P/N 7097 Revision Status Revision Date Reason For Change.0 FEB97 Initial Release.0 06DEC99 Add the following installation sheets to the manual; AB, CRR, MAB, MCR, MCRR, MCC, MCC, MCT, UIO, and UIO6(R). Remove SIGA-RB Sounder Base. Signature Series Component Installation Manual iii

iv Signature Series Component Installation Manual

WIRING VDC out to next device (if required) + Alarm Wiring VDC from panel DATA IN + + 8 7 6 SINGLE INPUT SIGNAL MODULE 0 9 + + -CTM + + Master Box Municipal Circuit + DATA OUT Notes VDC from panel DATA IN VDC out to next device (if required) + + + + DATA OUT 8 7 6 SINGLE INPUT SIGNAL MODULE 0 9 Supervisory Wiring -CTM + + + + Master Box Municipal Circuit 00mA into a. trip coil max., loop resistance =. ) Circuit is supervised for OPENS. Circuit not supervised for OPENS and is not power limited. ) The Single Input Signal Module and the -CTM must be installed in the same room within three feet of each other. PRODUCT INFORMATION -CTM Description The City Tie Module (-CTM) is designed for use with Signature controllers. The -CTM is an interface between a Single Input Signal Module or a Dual Input Signal Module and a Master Box. It provides off premise signal transmission for systems which must comply with the provisions of the NFPA. The -CTM is used to activate a local energy fire alarm box, which provides a VDC alarm signal which is current limited at 00 ma. SPECIFICATIONS Power Municipal Box Operation Max. Wiring Resistance Trip Current Max. Current Standby Current Mounting Nominal VDC @ 00mA Nominal VDC 00mA into. Coil 00mA 0mA Single Gang Box INSTALLATION SHEET: INSTALLATION SHEET P/N: 7096 FILE NAME: 7096.CDR REVISION LEVEL:. APPROVED BY: SJ DATE: 08//97 CREATED BY: MR A UNIT OF GENERAL SIGNAL GS BUILDING SYSTEMS CORPORATION -CTM City Tie Module GS BUILDING SYSTEMS CORPORATION 6 Parkland Drive 6 6th Street East Sarasota, FL Owen Sound, ON, Canada

Description Device addressing LEDs Mounting PRODUCT INFORMATION The Fire Alarm Station, 70 Series, is a component of the Signature Series. It is a normally-open, dry contact signal initiating device that requires only one action by the user in order to initiate an alarm. The single input module mounted to the back of the unit supervises the station and sends an alarm signal to the loop controller when the switch is closed (i.e. when the handle is pulled). One device address is required. The loop controller assigns an address to the station automatically. A custom address can be assigned to the station via laptop computer; no addressing switches are used. Diagnostic LEDs provide visible indication of the status of the station, when the unit is removed from the electrical box. Normal: Green LED flashes Alarm/active: Red LED flashes The terminal blocks will accept AWG,, 6, or 8 wire (.,.,.0, or 0.7 sq mm ). Sizes 6 and 8 are preferred. System controller capability The 70 Series requires the Signature Loop Controller. Personality code : N/O alarm latching The 70 Series is factory assigned personality code which configures the station for alarm latching operation. When the pull lever is activated, an alarm signal is sent to the Loop Controller and the alarm condition is latched at the fire alarm station. WARNINGS SPECIFICATIONS Construction: Cast zinc with steel backplate Operation mechanism: Single action, pull lever Operating voltage range:. - 9.9 Vdc Standby current: 0 A Activated current: 00 A Operating temperature range: to 0 F (0 to 9 C) Operating humidity range: 0-9%RH Replacement glass rods USA, P/N 76-GLR (pkg 0 rods) CAN, P/N 76 (pkg rods) Storage temperature range: - to 0 F (-0 to 60 C) Compatible electrical boxes North American: -/ in (6 mm) deep -gang box Standard: in square box -/ in (8 mm) deep with -gang cover Special order surface mount boxes 79-0: Cream enamel finish 79-: Red enamel finish Shipping weight:. lbs (0. kg) FIRE ALARM PRODUCT DIAGRAM LOCAL ALARM This device will NOT operate without electrical power. As fires frequently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. PULL IN CASE OF FIRE PULL IN CASE OF FIRE 70 70L INSTALLATION SHEET SIGA-70 and SIGA-70L Fire Alarm Stations INSTALLATION SHEET P/N: 8708P REVISION LEVEL: 6.0 DATE: 0JUN99 FILE NAME: 8708P.CDR APPROVED BY: B. Right CREATED BY: D. Chinell TM EDWARDS SYSTEMS TECHNOLOGY 6 Parkland Drive Sarasota, FL USA 6 6th Street East Owen Sound, Ontario Canada NK P8

INSTALLATION INSTRUCTIONS ) The pull station is shipped from the factory complete with a single input module attached. The electronic module contains no userserviceable parts and should NOT be disassembled. ) Open the pull-station by using a flat blade screwdriver to twist the cover release screw counterclockwise while pulling the cover away from its backplate. ) Verify that all field wiring is free of opens, shorts, and ground faults. ) Make all wiring connections as shown in the diagram. ) Write the address assigned to the pull-station on the label provided and apply the label to the pull-station. Peel off the removable serial number label from the pull-station and apply it to the appropriate location in the Serial Number Logbook. 6) Using the two 6- x /8 in (6 mm) machine screws provided, mount the pull-station to the electrical box. 7) Pull the glass rod release lever and install the glass rod through the mounting bracket on the front of the pull-station. Set the toggle switch to the NORMAL position and snap the cover into its locked position. Compatible electrical box NORMAL LIFT Back plate Toggle switch Glass rod release lever Cover release screw WIRING DIAGRAM Notes [] Refer to Signature Loop Controller Installation Sheet for wiring specifications. All wiring is power-limited and supervised. Factory connections: do NOT alter Green LED (normal) Red LED (alarm/active) TB Wire Stripping Guide DATA IN (+) DATA OUT (+) DATA IN ( ) DATA OUT ( ) / in (~6 mm) From Signature controller or previous device [] To next device Strip / in (about 6 mm) from the ends of ALL wires that connect to the terminal block of the module. REAR VIEW of 70 Series CAUTION: Exposing more wire may cause a ground fault. Exposing less wire may result in a faulty connection. P/N: 8708P REV: 6.0 PG: /

Device addressing LEDs Mounting PRODUCT INFORMATION Description The -Stage Fire Alarm Station, 70P, is a component of the Signature Series. The 70P is a normally-open, dry contact, signal initiating device that requires one action by the user in order to initiate a pre-alarm. A keyswitch is used to activate the general alarm upon verification that evacuation is necessary. (Note: The alarm handle must be in the pulled position in order to insert the key.) The dual input module mounted to the back of the unit supervises the station. Input is used to send a pre-alarm signal to the loop controller when the switch is closed (i.e. when the handle is pulled). Input of the module is used to send an alarm signal to the loop controller when the keyswitch is activated. Two device addresses are required. The loop controller assigns two addresses to the 70P automatically. Custom addresses can be assigned to the station via laptop computer; no addressing switches are used. Diagnostic LEDs provide visible indication of the status of the station, when the unit is removed from the electrical box. Normal: Green LED flashes Alarm/active: Red LED flashes The 70P may be flush mounted in a standard in square box -/ in (8 mm) deep with -gang cover, or it may be surface mounted using a special order electrical box. (Refer to the specifications section of this sheet for ordering information.) The terminal block will accept,, 6, or 8 AWG wire (.,.,.0, or 0.7 sq mm). Sizes 6 and 8 are preferred. System controller capability The 70P requires the Signature Loop Controller. Personality Code : N/O Alarm Latching (Class B) Inputs and of the 70P are factory assigned personality code. When the keyswitch is activated, an alarm signal is sent to the loop controller and the alarm condition is latched at the fire alarm station. SPECIFICATIONS Operating voltage range:. - 9.9 Vdc Standby current: 96 A Activated current: 680 A Operating temperature range: to 0 F (0 to 9 C) Operating humidity range: 0 to 9 % RH Construction: Cast zinc with steel backplate Operating mechanism: Single action, pull lever with keyswitch Shipping Weight:. lbs (0. kg) Compatible electrical boxes Standard in square box -/8 in ( mm) deep box with -gang cover Replacement glass rods USA, P/N 70-GLR (pkg 0 rods) CAN, P/N 76 (pkg rods) Special order surface mount boxes 79-: WHD =x-/ x -/ in (76 x x 6 mm). Red enamel. Combination / and / in knockouts top, bottom, rear. 76B-RSB: WHD = -/ x -/ x -7/6 in (89 x 8 x 6 mm). Red enamel. Combination / and / in knockouts top, bottom, rear. Wiremold C7: Buff, cream enamel finish. Combination / and in knockouts top, bottom, rear PRODUCT DIAGRAM FIRE ALARM WARNINGS This device will NOT operate without electrical power. As fires frequently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. PULL IN CASE OF FIRE INSTALLATION SHEET SIGA-70P -Stage Fire Alarm Station INSTALLATION SHEET P/N: 870P REVISION LEVEL:.0 DATE: 0JUN99 FILE NAME: 870P.CDR APPROVED BY: B. Right CREATED BY: D. Chinell TM EDWARDS SYSTEMS TECHNOLOGY 6 Parkland Drive Sarasota, FL USA 6 6th Street East Owen Sound, Ontario Canada NK P8

INSTALLATION INSTRUCTIONS ) The 70P is shipped from the factory as an assembled unit; it contains no user-serviceable parts and should NOT be disassembled. ) Open the pull station using a flat blade screwdriver to twist the cover release screw counter-clockwise, while pulling the cover away from its backplate. ) Verify that all field wiring is free of opens, shorts, and ground faults. ) Make all wiring connections as shown in the wiring diagram. ) Write the address assigned to the module on the label provided and apply the label to the module. Peel off the removable serial number label from the module and apply it to the appropriate location in the Serial Number Logbook. 6) Using the two 6- x /8 in (6 mm) machine screws provided, mount the pull-station to the electrical box. 7) Pull the glass rod release lever and install the glass rod through the mounting bracket on the front of the pull station. Push the glass rod release lever into its closed position. Set the toggle switch to the NORMAL position, and snap the cover into its locked position. Compatible electrical box Cover release screw NORMAL LIFT Back plate Toggle switch Glass rod release lever WIRING DIAGRAM Notes [] Refer to Signature Loop Controller Installation Sheet for wiring specifications. All wiring is power-limited and supervised. Factory connections: do NOT alter Green LED (normal) Red LED (alarm/active) TB Wire Stripping Guide DATA IN (+) DATA OUT (+) DATA IN ( ) DATA OUT ( ) / in (~6 mm) From Signature controller or previous device [] To next device Strip / in (about 6 mm) from the ends of ALL wires that connect to the terminal block of the module. REAR VIEW CAUTION: Exposing more wire may cause a ground fault. Exposing less wire may result in a faulty connection. P/N: 870P REV:.0 PG: /

SPECIFICATIONS Temporal Continuous Operating Voltage (Note #) 0 to VDC 0 to V FWR 0 to VDC 0 to V FWR Low Vol. High Vol. Operating Current (UL 68 Individual alarm) 0mA ma 9mA 7mA 0mA ma 9mA 7mA Operating Current (UL 6 Reverse Polarity) 0mA 60mA ma 7mA 0mA 60mA ma 7mA Sound Level Output @ 0 ft (.0 M) Note # Low Volume High Volume Low Volume High Volume Anechoic - Peak @ VDC 99 dba 99 dba 0 dba 99 dba 0 dba Low Vol. High Vol. Low Vol. High Vol. Anechoic - Average @ VDC 9 dba 98 dba 9 dba 98 dba Reverberant Room per UL 6 @ VDC 79 dba 8 dba 79 dba 8 dba Reverberant Room per UL 6 @ 0 VDC 79 dba 8 dba 79 dba 8 dba Reverberant Room per UL 68 8 dba 8 dba 8 dba 8 dba Synchronization Pulses at temporal rate within 00 ms on common circuit (Note #) Compatible Detectors Operating Temperature Operating Humidity Storage Temperature Construction & Finish Maximum Distance from Ceiling (wall mount) Compatible Electrical Boxes Shipping Weight Signature Series Detectors F to 00 F (0 C to 8 C) 0 to 9% RH - F to 0 F (-0 C to 60 C) High Impact Engineering Polymer, White in (0 mm) Low Vol. High Vol. North American " (0 mm) Square by -/8" ( mm) deep; mud box (in x in octagonal concrete ring); European 00 mm Lb. (0. Kg) NOTES:. The horn must be connected to a continuous voltage when it is set to sound a temporal horn; it may be connected to either a pulsed or continuous voltage when set to sound a steady tone.. For sleeping area installations, the HIGH VOLUME setting must be used.. The temporal pattern for the horn is : /s ON, /s OFF, /s ON, /s OFF, /s ON, -/s OFF, repeat cycle.. The base will accept # AWG (. mm ), # (. mm ), #6 (.0 mm ), and #8 (0.7 mm ) wire. Size #6 and #8 are preferred.. Break wire run at each terminal. Do not loop wires around terminals. 6. Rated F to 0 F (0 C to 9 C) when used with model SIGA-PS or SIGA-IS. 7. At power up, units may sound for 0 seconds. Do NOT connect VDC until mapping is complete. INSTALLATION INSTRUCTIONS SIGA-AB North American " (0 mm) Square -/8" ( mm) Deep Box, mud box (concrete ring); European 00 mm../6 in (7 mm) 6 /6 in (7 mm) INSTALLATION SHEET: SIGA-AB Audible Detector Base DRAWING PART NO.: 707P REVISION LEVEL:. DATE: 08//97 FILE NAME: 707.CDR APPROVED BY: RR CREATED BY: R W A UNIT OF GENERAL SIGNAL GS BUILDING SYSTEMS CORPORATION GS BUILDING SYSTEMS CORPORATION 6 Parkland Drive 6 6th Street East Sarasota, FL Owen Sound, ON, Canada

WIRING Base Wiring and Jumper Settings JW OUT = Low Volume IN = High Volume JW OUT = Steady Tone IN = Temporal Tone JW JW SIG - SIG + DATA (-) OUT DATA (-) IN DATA (+) IN/OUT From Power Supply To Next Sounder Base or or Previous Sounder Base EOL Relay VDC IN (+) VDC OUT (+) VDC IN (-) VDC OUT (-) DATA OUT (-) DATA IN (-) DATA IN (+) From Signature Controller or Previous Device Head Operates Its Sounder (complies with UL 68) Audible Bases 6A-00 EOL Relay DATA OUT (+) To Next Signature Device SIGA-CRR Activates ALL Sounders, Head Operates Its Sounder (complies with UL 68 & UL 6) Listed VDC Power Supply Audible Bases 6A-00 EOL Relay Listed VDC Power Supply Signature Controller Optional SIGA-CR for disabling/disconnecting sounder base Signature Controller Optional SIGA-CR for disabling/disconnecting sounder base NOTES All wiring supervised and power limited. Sounder operates when detector operates (UL 68). Sounder operates when polarity of power supply is reversed, i.e. SIGA-CRR module activated (UL 6). Optional SIGA-CR module used to silence sounders. End-Of-Line relay must monitor and report power supply trouble to control panel. 6 Class B data wiring may be "T-tapped." 7 Polarity of power supply circuit shown in supervisory state.

PRODUCT INFORMATION DESCRIPTION The Single Input Signal Module, Model SIGA-CC, is a component of the Signature Series System. The SIGA-CC is an analog addressable device used to connect a supervised output circuit to the riser bus. The SIGA-CC does NOT provide supervision of the riser; the fire alarm panel must provide this function. Upon command from the loop controller, the SIGA-CC connects the output circuit to the riser input which may be VDC to operate polarized audible and visual signals, V or 70V to operate audio evacuation circuits, or telephone audio. One () device address is required. The actual function performed by the SIGA-CC is determined by the personality code that is downloaded to the module by the Signature Loop Controller during system configuration. The loop controller assigns an address to the SIGA-CC automatically or a custom address can be assigned to the module via laptop computer; no addressing switches are used. Diagnostic LEDs provide visible indication of the status of the module when the cover plate is removed. Status Normal Alarm/Active LED Indicator Green LED flashes. Red LED flashes. Operating Voltage Range Standby Current Activated Current Output Ratings: V DC V Audio 70V Audio EOL Resistor Value (EOLR) Max. Circuit Resistance Max. Circuit Capacitance Operating Temperature Range Operating Humidity Range Storage Temperature Range Construction Shipping Weight Compatible Electrical Boxes SPECIFICATIONS. - 9.9 Vdc A 00 A A 0W W 7K, UL/ULC Listed Refer to Manual 0. F to 0 F (0 to 9 C) 0 to 9% RH - to 0 F (-0 to 60 C) High Impact Polymer 7.7 oz (8 g) North American -/" (6 mm) Deep -Gang Box Standard Square Box -/" (8 mm) Deep Box European 00 mm Square Box Comments: ) Power limited when connected to a power-limited power supply. ) Power limited when connected to a power-limited audio amplifier. ) Non-power limited when connected to a non-power limited source. Power limited mark must be covered up. The SIGA-CC can be mounted in a NorthAmerican -/" (6 mm) deep -gang box, standard " square -/" (8 mm) deep box, or European 00 mm square box. The terminal blocks will accept #, 6 or 8 AWG wire (. mm,.0 mm, 0.7 mm ). Sizes #6 and #8 are preferred. SYSTEM CONTROLLER COMPATIBILITY The SIGA-CC requires the Signature Loop Controller. The loop controller downloads the personality code which determines how the module will operate. The following personality codes may be downloaded to the SIGA-CC: Personality Code : Riser Selector (Single Input) The SIGA-CC is factory assigned personality code. Personality code configures the SIGA-CC as a Signal Power (VDC) or Audio Evacuation ( or 70 V) Riser Selector. Since the SIGA-CC is NOT being used for telephone audio under this personality code, the ring-tone generator is DISABLED. The output circuit is monitored for open or shorted wiring. If a short exists, the control panel inhibits the activation of the audible/visual signal circuit, so the riser is not connected to the wiring fault. WARNINGS ) This module will NOT operate without electrical power. As fires frequently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. ) This module does NOT support conventional smoke detectors. Single Input Signal Module, SIGA-CC Personality Code 6: Riser Selector (Single Input), Ring-Tone Personality code 6 configures the SIGA-CC as a Telephone Riser Selector. When a telephone handset is plugged into its jack or lifted from its hook, the SIGA-CC will generate its own ring-tone signal (a separate ring-tone riser is NOT needed). The module sends this signal to the control panel to indicate that an off-hook condition is present, and waits for the system operator to respond to the call. When the system operator responds, the ring-tone signal is DISABLED. IMPORTANT NOTE: TRANSIENT PROTECTION INSTALLATION SHEET: This module requires transient protection for installations in which electromechanical bells or horns are connected to the output circuits. A Bi-Polar Transient Protector (P/N 96P) MUST be used to protect the module's electronic circuitry from the effects of electronic transients caused by the inductive load of bells or horns. The bi-polar transient protector assembly should be connected across the terminals of the bell or horn located electrically closest to the module. The bi-polar transient protector is not polarity sensitive. Bells and horns MUST be located a minimum of 6 ft. (.8 m) from the module. INSTALLATION SHEET P/N: 870P REVISION LEVEL: 6.0 DATE: 07/06/98 A UNIT OF GENERAL SIGNAL GS BUILDING SYSTEMS CORPORATION SIGA-CC Single Input Signal Module FILE NAME: 870P.CDR APPROVED BY: LM CREATED BY: MR GS BUILDING SYSTEMS CORPORATION 6 Parkland Drive Sarasota, FL USA 6 6th Street East Owen Sound, Ontario Canada NK P8

) The SIGA-CC is shipped from the factory as an assembled unit; it contains no user-serviceable parts and should NOT be disassembled. ) Refer to Technical Bulletin (P/N 70) for installation guidelines. ) Verify that all field wiring is free of opens, shorts, and ground faults. ) Make all wiring connections as shown in the wiring diagram. ) Write the address assigned to the module on the label provided and apply the label to the module. Peel off the removable serial number label from the module and apply it to the appropriate location in the Serial Number Logbook. 6) Using the two 6- x /8" (9. mm) machine screws provided, mount the module to the electrical box. 7) Using the four - x /6" (7.9 mm) self-tapping screws provided, mount the wall plate to the module. NOTE: ) Wire in accordance with NFPA70-996, National Electrical Code Article 760, Section 760-(a)(), Exceptions No. and. INSTALLATION INSTRUCTIONS Wire Stripping Guide Strip /" (6. mm) from the ends of ALL wires that connect to the terminal block of the module. CAUTION: Exposing more than /" (6. mm) of wire may cause a ground fault. Exposing less than /" (6. mm) of wire may result in a faulty connection. Single Input Signal Module, SIGA-CC (Personality Code or 6) 6) For maximum wire resistance, refer to the appropriate technical reference manual. Max. #AWG (. mm ) wire; Min. #8 (0.7 mm ) Refer to Signature Loop Controller Installation Sheet for wiring specifications. Power-limited and supervised. Supervised and power limited when connected to power limited source. If non-power limited, then all power limited wiring in box must use FPL, FPLR, or FPLP cable or equivalent per NEC. Power limited marking must be eliminated. This module will NOT support -wire smoke detectors. 7) Polarity at terminals 9 & 0 on Notification Appliance, Telephone, and Speaker Circuits shown in Supervisory condition. Connect as shown in diagram. (Polarity reverses on alarm.)

PRODUCT INFORMATION DESCRIPTION The Dual Input Signal Module, Model SIGA-CC, is a component of the Signature Series System. The SIGA-CC is an analog addressable device used to connect up to two supervised output circuits (riser and riser ). The SIGA-CC does NOT provide supervision of the riser; the fire alarm panel must provide this function. Upon command from the loop controller, the SIGA-CC connects the output circuit to either the riser or riser bus; which may be VDC to operate polarized audible and visual signals or V or 70V to operate audio evacuation circuits. Two () device addresses are required. The actual function performed by the SIGA-CC is determined by the personality code that is downloaded to the module by the Signature Loop Controller during system configuration. The loop controller assigns two addresses to the SIGA-CC automatically or custom addresses can be assigned to the module via laptop computer; no addressing switches are used. Diagnostic LEDs provide visible indication of the status of the module when the cover plate is removed. Status Normal Alarm/Active LED Indicator Green LED flashes. Red LED flashes. The SIGA-CC can be mounted in a North American -/" (6 mm) deep - gang box, standard " square -/" (8 mm) deep box, or European 00 mm square box. The terminal blocks will accept #, 6 or 8AWG wire (. mm,.0 mm, 0.7 mm ). Sizes #6 and #8 are preferred. SYSTEM CONTROLLER COMPATIBILITY The SIGA-CC requires the Signature Loop Controller. The loop controller downloads the personality code which determines how the module will operate. The following personality code may be downloaded to the SIGA- CC: Personality Code 7: Riser Selector (Dual Input) The SIGA-CC is factory assigned personality code 7. Personality code 7 configures the SIGA-CC as a one of two output Signal Power (V DC) or. Audio Evacuation ( or 70V) Riser Selector. Each output circuit is monitored for open or shorted wiring. If a short exists, the control panel inhibits the activation of the audible/visual signal circuit, so the riser is not connected to the wiring fault. Operating Voltage Range Standby Current Activated Current Output Ratings: V DC V Audio 70V Audio EOL Resistor Value (EOLR) Max. Circuit Resistance Max. Circuit Capacitance Operating Temperature Range Operating Humidity Range Storage Temperature Range Construction Shipping Weight Compatible Electrical Boxes SPECIFICATIONS. - 9.9 Vdc A 00 A A 0W W 7K, UL/ULC Listed Refer to Manual 0. F to 0 F (0 to 9 C) 0 to 9% RH - to 0 F (-0 to 60 C) High Impact Polymer 7.7 oz (8 g) North American -/" (6 mm) Deep -Gang Box Standard " Square Box -/" (8 mm) Deep Box European 00 mm Square Box WARNINGS ) This module will NOT operate without electrical power. As fires frequently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. ) This module does NOT support conventional smoke detectors. Dual Input Signal Module, SIGA-CC IMPORTANT NOTE: TRANSIENT PROTECTION This module requires transient protection for installations in which electromechnanical bells or horns are connected to the output circuits. A Bi-Polar Transient Protector (P/N 96P) MUST be used to protect the module's electronic circuitry from the effects of electronic transients caused by the inductive load of bells or horns. The bi-polar transient protector assembly should be connected across the terminals of the bell or horn located electrically closest to the module. The bi-polar transient protector is not polarity sensitive. Bells and horns MUST be located a minimum distance of 6 ft. (.8 m) from the module. INSTALLATION SHEET: INSTALLATION SHEET P/N: 8700P REVISION LEVEL: 6.0 DATE: 07/06/98 A UNIT OF GENERAL SIGNAL GS BUILDING SYSTEMS CORPORATION SIGA-CC Dual Input Signal Module FILE NAME: 8700P.CDR APPROVED BY: LM CREATED BY: MR GS BUILDING SYSTEMS CORPORATION 6 Parkland Drive 6 6th Street East Sarasota, FL Owen Sound, ON, Canada

INSTALLATION INSTRUCTIONS ) The SIGA-CC is shipped from the factory as an assembled unit; it contains no user-serviceable parts and should NOT be disassembled. ) Refer to Technical Bulletin (P/N 70) for installation guidelines. ) Verify that all field wiring is free of opens, shorts, and ground faults. ) Make all wiring connections as shown in the wiring diagram. ) Write the address assigned to the module on the label provided and apply the label to the module. Peel off the removable serial number label from the module and apply it to the appropriate location in the Serial Number Logbook. 6) Using the two 6- x /8" (9. mm) machine screws provided, mount the module to the electrical box. 7) Using the four - x /6" (7.9 mm) self-tapping screws provided, mount the wall plate to the module. NOTE: ) Wire in accordance with NFPA70-996, National Electrical Code Article 760, Section 760-(a)(), Exceptions No. and. Wire Stripping Guide Strip /" (6. mm) from the ends of ALL wires that connect to the terminal block of the module. CAUTION: Exposing more than /" (6. mm) of wire may cause a ground fault. Exposing less than /" (6. mm) of wire may result in a faulty connection. Dual Input Signal Module, SIGA-CC (Personality Code 7) For maximum wire resistance, refer to the appropriate technical reference manual. Max. # AWG (. mm ) wire; Min. #8 (0.7 mm ). Refer to Signature Loop Controller Installation Sheet for wiring specifications. Power-limited and supervised. Supervised and power limited when connected to power limited source. If non-power limited, then all power limited wiring in box must use FPL, FPLR, or FPLP cable or equivalent per NEC. Power limited marking must be eliminated. 6 This module will not support -wire smoke detectors. 7 Polarity at terminals 9 and 0 on Notification Appliance, Telephone, and Speaker Circuits shown in Supervisory condition. Connect as shown in diagram (polarity reverses on alarm).

PRODUCT INFORMATION SPECIFICATIONS DESCRIPTION The Control Relay Module, Model SIGA-CR, is a component of the Signature Series System. The SIGA-CR is an addressable device used to provide one Form "C" dry relay contact to control external appliances (door closers, fans, dampers, etc.) or equipment shutdown. The system firmware ensures that the relay is in the proper ON/OFF state. Upon command from the loop controller, the SIGA-CR relay energizes. TB-6 and TB-7 provide a normally-closed relay connection; TB-7 and TB-8 provide a normallyopen relay connection. One () device address is required. The loop controller assigns an address to the SIGA-CR automatically or a custom address can be assigned to the module via laptop computer; no addressing switches are used. Diagnostic LEDs provide visible indication of the status of the module, when the cover plate is removed. Status Normal Alarm/Active LED Indicator Green LED flashes. Red LED flashes. Operating Voltage Range Standby Current Activated Current Contact Ratings (Pilot Duty): V DC 0 AC Relay Type Operating Temperature Range Operating Humidity Range Storage Temperature Range Construction. - 9.9 Vdc 00 A 00 A A 0.A Form "C" to 0 F (0 to 9 C) 0 to 9% RH - to 0 F (-0 to 60 C) High Impact Engineering Polymer. oz ( g) Shipping Weight Compatible Electrical Boxes North American -/" (6 mm) Deep -Gang Box Standard " Square Box -/" (8 mm) Deep Box with -Gang Cover The SIGA-CR can be mounted in a North American -/" (6 mm) deep -gang box, or standard " square -/" (8 mm) deep box with -gang cover. The terminal blocks will accept #, 6 or 8 AWG wire (. mm,.0 mm, 0.7 mm ). Sizes #6 and #8 are preferred. SYSTEM CONTROLLER COMPATIBILITY The SIGA-CR requires the Signature Loop Controller. Personality Code 8: Dry Contact Output The SIGA-CR is factory assigned personality code 8 which configures the SIGA-CR as an output dry relay contact. WARNINGS ) This module will NOT operate without electrical power. As fires frequently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. ) Dangerouos voltages may be present at terminals even when power is shut off!! Control Relay Module, SIGA-CR INSTALLATION SHEET: SIGA-CR Control Relay Module INSTALLATION SHEET P/N: 870P REVISION LEVEL: 6.0 DATE: 07/06/98 FILE NAME: 870P.CDR APPROVED BY: LM CREATED BY: MR A UNIT OF GENERAL SIGNAL GS BUILDING SYSTEMS CORPORATION GS BUILDING SYSTEMS CORPORATION 6 Parkland Drive 6 6th Street East Sarasota, FL Owen Sound, ON, Canada

) The SIGA-CR is shipped from the factory as an assembled unit; it contains no user-serviceable parts and should NOT be disassembled. ) Refer to Technical Bulletin (P/N 70) for installation guidelines. ) Verify that all field wiring is free of opens, shorts, and ground faults. ) Make all wiring connections as shown in the wiring diagram. ) Write the address assigned to the module on the label provided and apply the label to the module. Peel off the removable serial number label from the module and apply it to the appropriate location in the Serial Number Logbook. 6) Using the two 6- x /8" (9. mm) machine screws provided, mount the module to the electrical box. 7) Using the four - x /6" (7.9 mm) self-tapping screws provided, mount the wall plate to the module. NOTE: ) If a " ( mm) -gang box is used, conduit can enter the electrical box through ONLY ONE knock out hole. ) If a -/" (6 mm) -gang box is used, conduit can enter the electrical box through ONE or BOTH knock-out holes. ) Wire in accordance with NFPA70-996, National Electrical Code Article 760, Section 760-(a)(), Exceptions No. and. INSTALLATION INSTRUCTIONS Wire Stripping Guide Strip /" (6. mm) from the ends of ALL wires that connect to the terminal block of the module. CAUTION: Exposing more than /" (6. mm) of wire may cause a ground fault. Exposing less than /" (6. mm) of wire may result in a faulty connection. Control Relay Module, SIGA-CR (Personality Code 8) Refer to Signature Loop Controller Installation Sheet for wiring specifications. SIGA-CR must be installed within the same room as the device it is controlling. ) Maximum # AWG (.mm ) wire; Minimum #8AWG (0.7mm ). Power limited and supervised. Supervised and power limited when connected to power limited source. If non-power limited, then all power limited wiring in box must use FPL, FPLR, or FPLP cable or equivalent per NEC. Power limited marking must eliminated.

PRODUCT INFORMATION DESCRIPTION The Polarity Reversal Relay Module, Model SIGA-CRR, is a component of the Signature Series System. The SIGA-CRR is an addressable device used to power and activate the audible sounder in SIGA-AB Audible Bases. The module can support a amp load of Audible Bases. The system firmware ensures that the relay is in the proper state when powered up. Upon command from the loop controller, the SIGA-CRR relay energizes, reversing the polarity of its VDC output. One () device address is required for the Polarity Reversal Relay Module. The loop controller assigns an address to the SIGA-CRR automatically or a custom address can be assigned to the module via laptop computer; no addressing switches are used. Diagnostic LEDs provide visible indication of the status of the module. Status Normal Alarm/Active LED Indicator Green LED flashes. Red LED flashes. Operating Voltage Range Standby Current Activated Current Contact Ratings (Pilot Duty): V DC Operating Temperature Range Operating Humidity Range Storage Temperature Range Construction SPECIFICATIONS. - 9.9 Vdc 00 A 00 A A F to 0 F (0 C to 9 C) 0 to 9% RH - F to 0 F (-0 C to 60 C) High Impact Engineering Polymer. oz ( g) Shipping Weight Compatible Electrical Boxes North American -/" (6 mm) Deep -Gang Box Standard " Square Box -/" (8 mm) Deep w/-gang Cover The SIGA-CRR can be mounted in a North American -/" (6 mm) deep -gang box, or standard " square -/" (8 mm) deep box with -gang cover. The module can also be mounted in the fire alarm enclosure using the SIGA-MP Mounting Plate. The terminal blocks will accept #, 6, or 8 AWG wire (. mm,.0 mm, 0.7 mm ). SYSTEM CONTROLLER COMPATIBILITY The SIGA-CRR requires a Signature Loop Controller to operate. Personality Code 8: Dry Contact Output The SIGA-CRR is factory assigned personality code 8 which configures the SIGA-CRR as a constant power polarity reversing device. WARNINGS ) This module will NOT operate without electrical power. As fires frequently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. SIGA-CRR INSTALLATION SHEET: SIGA-CRR Polarity Reversal Relay Module INSTALLATION SHEET P/N: 876P REVISION LEVEL:.0 DATE: 09//97 FILE NAME: 876P.CDR APPROVED BY: RR CREATED BY: R W A UNIT OF GENERAL SIGNAL GS BUILDING SYSTEMS CORPORATION GS BUILDING SYSTEMS CORPORATION 6 Parkland Drive 6 6th Street East Sarasota, FL Owen Sound, ON, Canada

INSTALLATION INSTRUCTIONS SIGA-CRR, Personality Code 8 ) The SIGA-CRR is shipped from the factory as an assembled unit; it contains no user-serviceable parts and should NOT be disassembled. ) Verify that all field wiring is free of opens, shorts, and ground faults. ) Make all wiring connections as shown in the wiring diagram. ) Write the address assigned to the module on the label provided and apply the label to the module. Peel off the removable serial number label from the module and apply it to the appropriate location in the Serial Number Logbook. ) Using the two 6- x /" ( mm) machine screws provided, mount the module to the electrical box. 6) Using the - x /6" (8 mm) self-tapping screw provided, mount the wall plate to the module. 7) The module can be mounted in the fire alarm enclosure using the SIGA-MP Mounting Plate. NOTES: ) If a " ( mm) -gang box is used, conduit can enter the electrical box through ONLY ONE knock-out. ) If a -/" (6 mm) -gang box is used, conduit can enter the electrical box throuogh ONE or BOTH knock-outs. ) Wire in accordance with NFPA70-996, National Electrical code Article 760, Section 760-(a)(), Exception No. and. Wire Stripping Guide Listed VDC Power Supply Schematic Head Operates its Sounder Audible Bases 6A-00 EOL Relay Strip /" (6. mm) from the ends of ALL wires that connect to the terminal block of the module. CAUTION: Exposing more than /" (6. mm) of wire may cause a ground fault. Exposing less than /" (6. mm) of wire may result in a faulty connection. SIGA-MP Signature Controller Optional SIGA-CR for disabling/disconnecting sounder base SIGA-CRR Activates ALL Sounders, Head Operates its Sounder Listed VDC Power Supply Audible Bases 6A-00 EOL Relay Compatible Electrical Box Wall Plate, White (-Gang) Self Adhesive French Label (Optional) Signature Controller Optional SIGA-CR for disabling/disconnecting sounder base Notes All wiring is power-limited and supervised.

PRODUCT INFORMATION DESCRIPTION The Single Input Module, Model SIGA-CT, is a component of the Signature Series System. The SIGA-CT is an analog addressable device used to connect a Class B normally-open Alarm, Supervisory, or Monitor type dry contact Initiating Device Circuit (IDC) to a Signature Loop Controller. One () device address is required. The SIGA-CT may be used for Alarm, Supervisory, or Monitor type applications as determined by the personality code that is downloaded to the module by the loop controller during system configuration. The loop controller assigns an address to the SIGA-CT automatically, or a custom address can be assigned to the module via laptop computer; no addressing switches are used. Diagnostic LEDs provide visible indication of the status of the module, when the cover plate is removed. Status Normal Alarm/Active LED Indicator Green LED flashes. Red LED flashes. The SIGA-CT can be mounted in a North American -/" (6 mm) deep - gang box, or standard " square box -/" (8 mm) deep with -gang cover. The terminal blocks will accept #, 6, or 8 AWG wire (. mm,.0 mm, 0.7 mm ). Sizes #6 and #8 are preferred. SYSTEM CONTROLLER COMPATIBILITY The SIGA-CT requires the Signature Loop Controller. The loop controller downloads the personality code which determines how the module will operate. The following personality codes may be downloaded to the SIGA- CT: Personality Code : N/O Alarm Latching (Class B) The SIGA-CT is factory assigned personality code. Personality code configures the SIGA-CT for Class B normally-open dry contact initiating devices (e.g., pull-stations, heat detectors, etc.). When the N/O input contact of an initiating device is closed, an alarm signal is sent to the loop controller and the alarm condition is latched at the module. Personality Code : N/O Alarm Delayed Latching (Class B) Personality code operates the same as personality code except that contact closure must be maintained for approximately 6 seconds before an Alarm status is generated. Personality code is only for use with nonretarded waterflow alarm switches. Operating Voltage Range Standby Current Activated Current Operating Temperature Range Operating Humidity Range Storage Temperature Range Construction SPECIFICATIONS. to 9.9 Vdc 0 A 00 A to 0 F (0 to 9 C) 0 to 9% RH - to 0 F (-0 to 60 C) High Impact Engineering Polymer. oz ( g) Shipping Weight Compatible Electrical Boxes North American -/" (6 mm) Deep -Gang Box Standard " Square Box -/" (8 mm) Deep Box w/-gang Cover Initiating Device Circuit (IDC): EOL Resistor Value (EOLR) 7K, UL Listed Max. Circuit Resistance 0 ( per wire) Max. Circuit Capacitiance 0. F Wire Size Max. Distance to EOLR #8 AWG (0.7 mm ),90' (,98m) #6 AWG (.0 mm ) 6,' (,897m) # AWG (. mm ) 9,900' (,08m) WARNINGS ) This module will NOT operate without electrical power. As fires frequently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. ) This module does NOT support conventional smoke detectors. Single Input Module, SIGA-CT Personality Code : N/O Active - Non-latching (Class B) A contact closure causes an active instead of an alarm status and does NOT latch at the module. Personality code is typically used for monitoring fans, dampers, doors, etc. Personality Code : N/O Active Latching (Class B) A contact closure causes an active instead of an alarm status, which is latched at the module. Personality code is typically used for monitoring supervisory and tamper switches. IMPORTANT NOTE: TRANSIENT PROTECTION INSTALLATION SHEET: SIGA-CT Single Input Module INSTALLATION SHEET P/N: 870P REVISION LEVEL: 6.0 DATE: 0/0/98 FILE NAME: 870P.CDR APPROVED BY: RR CREATED BY: MR A UNIT OF GENERAL SIGNAL GS BUILDING SYSTEMS CORPORATION GS BUILDING SYSTEMS CORPORATION 6 Parkland Drive 6 6th Street East Sarasota, FL Owen Sound, ON, Canada

INSTALLATION INSTRUCTIONS ) The SIGA-CT is shipped from the factory as an assembled unit; it contains no user-serviceable parts and should NOT be disassembled. ) Refer to Technical Bulletin (P/N 70) for installation guidelines. ) Verify that all field wiring is free of opens, shorts, and ground faults. ) Make all wiring connections as shown in the wiring diagram. ) Write the address assigned to the module on the label provided and apply the label to the module. Peel off the removable serial number label from the module and apply it to the appropriate location in the Serial Number Logbook. 6) Using the two 6- x /" ( mm) machine screws provided, mount the module to the electrical box. 7) Using the four - x /6" (8 mm) self-tapping screws provided, mount the wall plate to the module. NOTES: ) If a " ( mm) -gang box is used, conduit can enter the electrical box through ONLY ONE knock-out hole. ) If a -/" (6 mm) -gang box is used, conduit can enter the electrical box through ONE or BOTH knock-out holes. Wire Stripping Guide Strip /" (6. mm) from the ends of ALL wires that connect to the terminal block of the module. CAUTION: Exposing more than /" (6. mm) of wire may cause a ground fault. Exposing less than /" (6. mm) of wire may result in a faulty connection. Single Input Module (Personality Codes,,, and ) NOTES Maximum resistance per wire. Max. #AWG (. mm ) wire; Min. #8 (0.7 mm ). Refer to Signature Loop Controller Installation Sheet for wiring specifications. Maximum 0 VDC @ 0 A. ) All wiring is power-limited and supervised. 6) This module will NOT support -wire smoke detectors.

PRODUCT INFORMATION DESCRIPTION The Dual Input Module, model SIGA-CT, is a component of the Signature Series System. The SIGA-CT is an analog addressable device used to connect up to two Class B normally-open Alarm, Supervisory, or Monitor type dry contact Initiating Device Circuits (IDCs) to a Signature Loop Controller. Two () device addresses are required. The SIGA-CT may be used for Alarm, Supervisory, or Monitor type applications as determined by the personality code that is downloaded to the module by the loop controller during system configuration. The loop controller assigns an address to the SIGA-CT automatically, or custom addresses can be assigned to the module via laptop computer; no addressing switches are used. Diagnostic LEDs provide visible indication of the status of the module, when the cover plate is removed. Status Normal Alarm/Active LED Indicator Green LED flashes. Red LED flashes. The SIGA-CT can be mounted in a North American -/" (6 mm) deep - gang box, or standard " square box -/" (8 mm) deep with -gang cover. The terminal blocks will accept #, 6, or 8 AWG wire (. mm,.0 mm, 0.7 mm ). Sizes #6 and #8 are preferred. SYSTEM CONTROLLER COMPATIBILITY The SIGA-CT requires the Signature Loop Controller. The loop controller downloads the personality code which determines how the module will operate. The following personality codes may be downloaded to the SIGA- CT: Personality Code : N/O Alarm Latching (Class B) The SIGA-CT is factory assigned personality code to input channels and. Personality code configures the SIGA-CT for Class B normallyopen dry contact initiating devices (e.g., pull-stations, heat detectors, etc.). When the N/O input contact of an initiating device is closed, an alarm signal is sent to the loop controller and the alarm condition is latched at the module. Personality Code : N/O Alarm Delayed Latching (Class B) Personality code operates the same as personality code except that contact closure must be maintained for approximately 6 seconds before an Alarm status is generated. Personality code is only for use with nonretarded waterflow alarm switches. Operating Voltage Range Standby Current Activated Current Operating Temperature Range Operating Humidity Range Storage Temperature Range Construction Shipping Weight Compatible Electrical Boxes North American -/" (6 mm) Deep -Gang Box Standard " Square Box -/" (8 mm) Deep Box w/-gang Cover Initiating Device Circuit (IDC): EOL Resistor Value (EOLR) 7K, UL Listed Max. Circuit Resistance 0 ( per wire) (per channel) Max. Circuit Capacitiance (per channel) SPECIFICATIONS. - 9.9 Vdc 96 A 680 A to 0 F (0 to 9 C) 0 to 9% RH - to 0 F (-0 to 60 C) High Impact Engineering Polymer. oz ( g) 0. F Wire Size Max. Distance to EOLR #8 AWG (0.7 mm ),90' (,98m) #6 AWG (.0 mm ) 6,' (,897m) # AWG (. mm ) 9,900' (,08m) WARNINGS ) This module will NOT operate without electrical power. As fires frequently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. ) This module does NOT support conventional smoke detectors. Dual Input Module, SIGA-CT Personality Code : N/O Active - Non-Latching (Class B) A contact closure causes an active instead of an alarm status and does NOT latch at the module. Personality code is typically used for monitoring fans, dampers, doors, etc. Personality Code : N/O Active Latching (Class B) A contact closure causes an active instead of an alarm status, which is latched at the module. Personality code is typically used for monitoring supervisory and tamper switches. INSTALLATION SHEET: SIGA-CT Dual Input Module INSTALLATION SHEET P/N: 8707P REVISION LEVEL: 6.0 DATE: 0/0/98 FILE NAME: 8707P.CDR APPROVED BY: RR CREATED BY: MR A UNIT OF GENERAL SIGNAL GS BUILDING SYSTEMS CORPORATION GS BUILDING SYSTEMS CORPORATION 6 Parkland Drive 6 6th Street East Sarasota, FL Owen Sound, ON, Canada

INSTALLATION INSTRUCTIONS ) The SIGA-CT is shipped from the factory as an assembled unit; it contains no user-serviceable parts and should NOT be disassembled. ) Refer to Technical Bulletin (P/N 70) for installation guidelines. ) Verify that all field wiring is free of opens, shorts, and ground faults. ) Make all wiring connections as shown in the wiring diagram. ) Write the address assigned to the module on the label provided and apply the label to the module. Peel off the removable serial number label from the module and apply it to the appropriate location in the Serial Number Logbook. 6) Using the two 6- x /" ( mm) machine screws provided, mount the module to the electrical box. 7) Using the four - x /6" (8 mm) self-tapping screws provided, mount the wall plate to the module. NOTES: ) If a " ( mm) -gang box is used, conduit can enter the electrical box through ONLY ONE knock-out hole. ) If a -/" (6 mm) -gang box is used, conduit can enter the electrical box through ONE or BOTH knock-out holes. ) Wire in accordance with NFPA70-996, National Electrical Code Article 760, Section 760-(a)(), Exception No. and. Wire Stripping Guide Strip /" (6. mm) from the ends of ALL wires that connect to the terminal block of the module. CAUTION: Exposing more than /" (6. mm) of wire may cause a ground fault. Exposing less than /" (6. mm) of wire may result in a faulty connection. Single Input Module (Personality Codes,,, and ) Maximum resistance per wire. Max. #AWG (. mm ) wire; Min. #8 (0.7 mm ). Refer to Signature Loop Controller Installation Sheet for wiring specifications. Maximum 0 VDC @ 0 A. ) All wiring is power-limited and supervised. 6) This module will NOT support -wire smoke detectors.

PRODUCT INFORMATION The model SIGA-DG Detector Guard is designed to prevent mechanical damage to Signature Series smoke detectors. Use of the guard does not affect detector performance, and requires no detector sensitivity increase. The guard is finished in white enamel, and secured with tamper-proof fasteners. Construction Finished Dimensions Compatible Devices Detectors SPECIFICATIONS 6 gauge steel 6." diameter x." height (6.cm x 8.6cm) SIGA-IPHS XLS-IPHS SIGA-PS XLS-PS GSA-PS INSTALLATION. Fasten the detector base (B) to the SIGA-DG mounting flange (A) using the two #8- machine screws provided.. Install the mounting flange and detector base (A & B) over the electrical box, using appropriate fasteners Mounting holes provide clearance for a #0 screw. Route the base wiring through the hole in the detector base.. Wire the base in accordance with the instructions provided with the base, then install the detector (C).. Secure the SIGA-DG guard cage (D) to the mounting flange using the four tamper-proof screws provided, and tighten securely. Bases Spacing Finish SIGA-IB SIGA-RB SIGA-SB Listed detector spacing is not affected by the guard White enamel GSA-IB GSA-RB GSA-SB INSTALLATION SHEET: SIGA-DG Detector Guard INSTALLATION SHEET P/N: 877P REVISION LEVEL:.0 DATE: 0//97 FILE NAME: 877(R.0).CDR APPROVED BY: RR CREATED BY: R W GS BUILDING SYSTEMS, CORP. SARASOTA, FL. 9-79-00 Fax: 9-7-806 CHESHIRE, CT. 0-699-000 Fax: 0-699-07 OWEN SOUND, CANADA 9-76-0 Fax: 9-76-78 INTERNATIONAL: CANADA 90-70-7 Fax: 90-70-9

PRODUCT INFORMATION The model SIGA-DG Detector Guard is designed to prevent mechanical damage to surface mounted Signature Series smoke detectors when used with the SIGA-DGS surface adapter. Use of the guard does not affect detector performance, and requires no detector sensitivity increase. Construction Dimensions Surface Adapter SPECIFICATIONS 6 gauge steel 8.87" diameter x." height (.cm x.7cm) The guard is finished in white enamel, and secured with tamper-proof fasteners. INSTALLATION. Install the SIGA-DGS surface adapter (A) over the electrical box/conduit using appropriate fasteners. Mounting holes provide clearance for a #0 screw.. Fasten the detector base (C) to the SIGA-DG mounting flange (B) using the two #8- machine screws provided.. Install the mounting flange and detector base (B & C) on surface adapter, using four #8 bolts provided. Route the base wiring through the hole in the base.. Wire the base in accordance with the instructions provided with the base, then install the detector (D).. Secure the guard cage (E) to the mounting flange using the four tamper-proof bolts provided, and tighten securely. Adapter & Guard Compatible Devices Detectors Bases Spacing Finish 8.87" diameter x." height (.cm x.97cm) SIGA-IPHS XLS-IPHS SIGA-PS XLS-PS GSA-PS SIGA-IB SIGA-RB SIGA-SB Listed detector spacing is not affected by the guard White enamel GSA-IB GSA-RB GSA-SB INSTALLATION SHEET: SIGA-DGS Surface Adapter for use with the SIGA-DG Detector Guard INSTALLATION SHEET P/N: 878P REVISION LEVEL:.0 DATE: 0//97 FILE NAME: 878(R.0).CDR APPROVED BY: RR CREATED BY: R W GS BUILDING SYSTEMS, CORP. SARASOTA, FL. 9-79-00 Fax: 9-7-806 CHESHIRE, CT. 0-699-000 Fax: 0-699-07 OWEN SOUND, CANADA 9-76-0 Fax: 9-76-78 INTERNATIONAL: CANADA 90-70-7 Fax: 90-70-9