STUDY, ANALYSIS AND DESIGN OF AUTOMOBILE RADIATOR (HEAT EXCHANGER) PROPOSED WITH CAD DRAWINGS AND GEOMETRICAL MODEL OF THE FAN

Similar documents
Chapter 1. Introduction, Literature Review and Need of Study

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Mechanical Engineering Department Sheet (1)

Gandhinagar Institute of Technology Mechanical Engineering (Thermal Engineering) Semester II. Design of Heat Exchange Equipments [ ]

Effects of Volute Tongue Clearance and Rotational Speed on Performance of Centrifugal Blower Nitin S. Jadhav *, S. R. Patil

Design, Manufacturing of Chilled Water System for Process Cooling Application

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

TITLE: Improvement in Heat Transfer Rate and Dynamics of Shrouded Fanned Radiator System

Performance of Shell and Tube Heat Exchanger under Varied Operating Conditions

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

Design, Development & Testing of Double Pipe Heat Exchanger With Heat Transfer Enhancement Liners

DESIGN AND ANALYSIS OF PIPE HEAT EXANGERS WITH INSIDE FINS

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Modified Air Cooler with Split Cooling Unit


Compression of Fins pipe and simple Heat pipe Using CFD

Design and Development of Water Cooled Condenser for Domestic Refrigerator

Fin-Fan Control System

Experimental analysis of condensation heat transfer enhancement of steam at low pressures using modified twisted tape insert

Performance Study of Triple Concentric Pipe Heat Exchanger

An Optimized Plate Fin Type Heat Exchanger

Enhancement of COP in Vapour Compression Refrigeration System

Rotodynamic Pumps INTRODUCTION:

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Performance Comparison of Hydronic Secondary Loop Heat Pump and Conventional Air-Source Heat Pump ABSTRACT 1. INTRODUCTION

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

Comparative Study of Transcritical CO 2 Cycle with and Without Suction Line Heat Exchanger at High Ambienttemperature

EXPERIMENTAL AND THEORTICAL STUDY OF THE THERMAL PERFORMANCE OF HEAT PIPE HEAT EXCHANGER

PERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

THE GATE COACH All Rights Reserved 28, Jia Sarai N.Delhi-16, ,-9998

Experimental Comparison of Natural Convection Heat Transfer from a Blackened V-Fin Array

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans

Module 5: Combustion Technology. Lecture 38: Combustion Burners

Design And Analysis Of Centrifugal Pump

As we discussed early in the first chapter that heat can transfer through materials and the surrounding medium whenever temperature gradient exists

HEAT TRANSFER COEFFICIENT ENHANCEMENT IN NATURAL CONVECTION FROM HORIZONTAL RECTANGULAR FIN ARRAYS WITH PERFORATIONS

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

CFD ANALYSIS OF DOUBLE PIPE PARALLEL FLOW HEAT EXCHANGER

Heat Exchanger. The purpose may be either to remove heat from a fluid or to add heat to a fluid.

Experimental Investigation of a Brazed Chevron Type Plate Heat Exchanger

Keywords: Triple tube heat exchanger (TTHE), hot water, cold water, CFD simulation.

A Review Paper on Extracting Waste Heat from the Engine Exhaust and Reutilizing in Car Air Conditioning

Dynamic Simulation of Double Pipe Heat Exchanger using MATLAB simulink

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

How is the heat transfer?

[Eswaran, 3(3): March, 2014] ISSN: Impact Factor: 1.852

A STUDY ON COMPACT HEAT EXCHANGERS AND PERFORMANCE ANALYSIS

CL4001 HEAT TRANSFER OPERATIONS

Design and Experimental Analysis of Concentric Tube Heat Exchangers with Various Fins

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

Performance of an Improved Household Refrigerator/Freezer

Implementation of Auto Car Washing System Using Two Robotic Arms

Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater

Adsorption refrigeration system using waste heat

ISSN Vol.04,Issue.12, September-2016, Pages:

Development of Large Size Hybrid Fan

IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 12 May 2015 ISSN (online):

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

ISSN (Online)

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Mallikarjun 1, Anandkumar S Malipatil 2

TRANSACTIONS ON ADVANCEMENTS IN SCIENCE AND TECHNOLOGY (TASTONLINE)

Natural Convection Heat Transfer Augmentation from Heat Sinks using Perforated Fins: A Review

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

Main Characteristics of Appliances for Transport and Compression of Air

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

EFFECT OF DIVERSE STREAM PATTERNS ON THE PERFORMANCE OF SOLAR AIR HEATER

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

HEAT EXCHANGERS. Heat exchangers are broadly classified based on the following considerations.

WASTE HEAT RECOVERY FROM DOMESTIC REFRIGERATOR Soma A. Biswas 1, Sandeep M. Joshi 2 1,2 Pillai College of Engineering

Performance Optimization of the Evaporative Condenser Design

Experimental Investigation of Heat Transfer Enhancement from Waveform Pin-Fins

Effects of Frost Formation on the External Heat Transfer Coefficient of a Counter-Crossflow Display Case Air Coil

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Effect of Flow Distortion in Inlet Duct on the Performance of Centrifugal Blower

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

[Vali*, 5(2): February, 2016] ISSN: (I2OR), Publication Impact Factor: 3.785

CFD and Thermal Analysis of FIN Tube Evaporator

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Theoritical Analysis For Miniature Vapor Compression Cycle Performance Using Microchannel And Finned Tube Condenser

Evaluation of Available Heat at the Exhaust of Automotive Engine for Air Conditioning by Vapor Absorption System

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

Water Cooled Condenser Using Nano Fluids

A Method of Heat Exchange Structure Optimization of the Cricoid Plastic Parts

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

DESIGN AND MANUFACTURING OF CHEMICAL AGITATOR

EXPERIMENTAL PERFORMANCE ANALYSIS OF SOLAR AIR HEATER WITH THREE DIFFERENT MODIFICATIONS IN ABSORBER PLATE

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Heat Exchangers. Heat Exchangers 1

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

Cost-Effective COP Enhancement of a Domestic Air Cooled Refrigerator using R-134a Refrigerant

Transcription:

International Journal of Mechanical and Production Engineering Research and Development (IJMPERD) ISSN 2249-6890 Vol. 3, Issue 2, Jun 2013, 137-146 TJPRC Pvt. Ltd. STUDY, ANALYSIS AND DESIGN OF AUTOMOBILE RADIATOR (HEAT EXCHANGER) PROPOSED WITH CAD DRAWINGS AND GEOMETRICAL MODEL OF THE FAN CHAVAN D. K 1 & TASGAONKAR G. S 2 1 Ph.D Scholar, JJTU Rajasthan, Professor Mechanical Engineering MMCOE, Pune, Maharashtra, India 2 Professor Navasahyadri Group of Institutions Pune, Maharashtra, India ABSTRACT The heat exchanger, used in refrigeration unit, air conditioning unit, radiator used with IC engine automobiles is either rectangular or square in shape. But the air blown/sucked by the fan is in circular area developing low velocity zones or high temperature regions are created in the corners. Different heat exchangers/radiators are studied; Radiator is designed, Calculations are done, CAD drawings of radiator and geometrical model are developed. Also power consumed by fan is studied. Experimentally it is found that the power consumed by fan is 2 to 5% of power produced by engine. It is proposed to have circular heat exchanger for refrigeration, air conditioning unit and for car radiators for maximum efficiency. Till now no significant work has been carried out on circular heat exchanger and radiators. KEYWORDS: Heat Exchanger, Radiator, Cad Model of Radiator, Geometrical Model of Fan, Power etc INTRODUCTION The proposed work relates to an improved heat exchanger (Radiator) design for either heating or cooling of a fluid. Also, it deals with the work particularly which relates to an improved fan assisted air-cooled heat exchanger used in Automobiles, Internal Combustion (IC) engines, Refrigeration system, and Power plants. Different types of heat exchangers are known, in which air is used as heat transfer medium as it is freely and abundantly available, without any disposal issues. In known heat exchangers, flow of air is induced naturally or is aided by the use of one or more fans. The use of fan reduces the size and the cost of the equipment, which makes it more compact. Hence, fan assisted air cooled heat exchangers are more popular than others. In known air-cooled heat exchangers, the fan either forces or draws the air through the heat exchanger, some of which are described herein below by way of examples. In present system, the fans are placed behind the heat exchangers to force/ draw the atmospheric air. These exchangers use a shroud. This directs the air over the entire area of the heat exchanger. A study was undertaken to find out the distribution of airflow and variation of its temperature [1]. Generally, all conventional heat exchangers are either square or rectangular in shape and the fans with circular blades are used to create the flow of air through them. For the present heat exchangers, there are several drawbacks or disadvantages which can be classified as follows Fans with circular blades deliver air in a circular area even when the heat exchangers are square in shape. The velocity of the air flow generated by the fan is not constant or uniform along its entire axial direction. It is almost zero at the centre and gradually increases at the rate of square of the radius.

138 Chavan D. K. & Tasgaonkar G. S When the thickness of the heat exchanger is constant, there has been no attempt to increase the heat transfer area at the periphery of such heat exchanger. The heat transfer area near the hub of the fan should be zero. Since this is not the case with present heat exchangers, they do not offer optimum utilization of material and air velocity. A square or rectangular shrouds were provided for the fan to convert the circular flow of air into the required shape. Further the known equipments consume more power, more material and are therefore not cost effective [3]. Therefore it has been proposed to develop a new heat exchanger, which would avoid all the disadvantages of the known equipments [2]. POWER CONSUMED BY FAN The automobile radiator sometimes needs additional airflow through it to prevent the engine from overheating. This usually occurs at idle and slow speed. At higher vehicle speeds, the air flows through the radiator by the forward motion of vehicle provide all the cooling that is needed. An engine fan or cooling fan pulls the additional air through the radiator. The fan may be either a mechanical fan or an electric fan. Engines mounted longitudinally in rear- drive vehicles usually have a mechanical fan that mounts to the water pump shaft. The fan is made of sheet steel or moulded plastic. It has four to seven blades and turns with the water pump impeller. A fan shroud around the fan directs the airflow. This increases the efficiency of the fan. Transverse engines in front-drive vehicles usually have an electric fan. An electric motor turns the blades. A thermostatic switch turns on the fan only when needed. Generally, the switch turns on the fan when the coolant reaches 70 0 80 0 C. It turns off the fan if the coolant drops below this temperature. On the experimental trial setup of Petrol Engine and Diesel Engine, trials are conducted in the college laboratory with fan and without fan. It is observed that power consumed by the fan is of considerable magnitude and is about 2% to 5% of total power developed by the engine [4]. Any saving in the fan power is directly the saving of precious fuel. Also BHP of the engine will be mentioned by the manufacturer or it can be calculated. Also it is observed from following examples that, Cummins engine make, 1645 BHP required 42 HP for fan i.e. 2.55% of engine power. Cummins engine make, 600 BHP required 17 HP for fan i.e. 2.83% of engine power. COST OF RADIATORS Smaller radiators may cost less but will consume more power; hence we have to optimize the design. Cost of radiators, heat transferred per unit area by radiator varies according to size, capacity and materials used for radiator and fins. Standard materials generally used are aluminum, copper, steel, alloys etc. as per the cost and capacity. EXISTING RECTANGULAR / SQUARE AND OTHER RADIATOR Rectangular Radiator

Study, Analysis and Design of Automobile Radiator (Heat Exchanger) 139 Proposed with Cad Drawings and Geometrical Model of the Fan Figure 2: Rectangular Radiator This existing design is most popularly used in the current applications. As shown in figure 2 hot water is allowed o flow through the inlet port, to upper tank where the hot water is distributed through a system of tubing. These tubes are surrounded and connected by a number of fins along the entire length of said tubes as shown. A fan is mounted on a shaft which causes a circulation or draught of air through the radiator and the fins. A shroud is adopted to regulate the flow of air from the fan so that it minimizes the quantity of air flow to escape. The atmospheric air collects the heat from the hot water as it flows over said system of tubes. The fins provided over the tubes increases the heat transfer area. The water entering through the inlet is allowed to flow the system of tubing before it gets cooled by the air and ultimately it comes out through an outlet port, after passing through the lower tank as shown. Heat exchanger for air conditioner Figure 3: Heat Exchanger for Air Conditioner Figure 3 shows a heat exchanger used in air conditioner, where the refrigerant enters the heat exchanger through an inlet port and it passes through a system of tubing. The flow of refrigerant takes place through the tubing. The tubing transfer heat to the air through a series of fins attached to the tubings. The refrigerant ultimately escapes out through an outlet port. As shown figure 3, in this case also a fan is provided to facilitate the air flow for enhancing the cooling / heating of refrigerant. Square Shaped Heat Exchanger This also is one of the constructional types of radiator existing in current market [5] Figure 4: Air-Cooled Square Shaped Heat Exchanger

140 Chavan D. K. & Tasgaonkar G. S Figure 4 shows a square-shaped heat exchanger with a fan provided to deliver air in a circular area. If the length and breadth of the heat exchanger is equal to D, the effective area of such heat exchanger will be equal to D 2. While the flow of air from the fan (without shroud) will be of area (π/4) D 2 = O.76 D 2. The difference in the area of the square and the circle would be {D 2 - (π/4) D 2 } = 0.24 D 2. OBJECTIVES OF PRESENT WORK To optimize the fan assisted heat exchanger (radiator) by improvement in design. To provide a heat exchanger that will be more efficient and compact. To provide a heat exchanger that will work with minimum power consumption for the fan and with maximum utilization of air flow. To have a heat exchanger with minimum material and will thus be less costly. Excluding the central hub area, the material saving is @ 24%, saving in the cost of production on mass scale basis once the dies are manufactured will be about 20 %. Considering the number of vehicles, refrigerators and air conditioners used at national and international levels, slight improvement in efficiency and reduction in cost will add to the economy to a great extent. CAD MODEL OF RADIATOR Material of tubes: Aluminium Number of tubes: 20 Inner Diameter of Tube: 10mm Outer diameter of tube: 11.25 mm Material of fin: Aluminium Thickness of fin: 0.16 mm GEOMERIC MODELING OF FAN Figure 5: Radiator CAD Drawing For CFD analysis of the radiator, it is necessary to create a geometric model of the system. A model of the radiator and the fan was made in CATIA V5 and then exported to CFD analysis software.

Study, Analysis and Design of Automobile Radiator (Heat Exchanger) 141 Proposed with Cad Drawings and Geometrical Model of the Fan PROPOSED HEAT EXCHANGER Figure 7: Fan Model Figure 8: Radiator Model To overcome the drawbacks of this current and conventional design, a new design with geometrical modifications is proposed to obtain efficient working of the radiator. Figure 9: Proposed Circular Heat Exchanger (Radiator) In the existing design, there is no heat transfer area at the centre where the flow of air is almost zero. In the proposed design the tubes and the fins are so arranged that the outlet air has nearly constant velocity [6]. Heat exchanger for the refrigeration air conditioning system Figure 11: Heat Exchanger for the Refrigeration Air Conditioning The Heat exchanger for the refrigeration air conditioning system as shown in figure 11 is provided with a number of fins of varying depth, maximum depth at the outer periphery and the reducing depth along the inner periphery. It is

142 Chavan D. K. & Tasgaonkar G. S found that the new heat exchanger as described herein above has better performance level in its application. Further it consumes less power and it is thus more economical. DESIGN CALCULATIONS FOR RADIATOR Available Data Table 3: Observations of Air and Water Sr. No. Observations Air (Cold) Water (Hot) 1 Inlet Temperature ( C) 28 52 2 Outlet Temperature ( C) 34.376 44 3 m i.e mass flow rate (kg/hr) 525.35 100 4 Cp. Specific Heat (kj/kg C) 1 4.187 5 K Thermal Conductivity (W/mK) 0.024 0.66 6 Density (kg/m 3 ) 1.1 1000 Assume: For this air cooled heat exchanger we use aluminum tubes of following dimension, Outer Diameter = 11.25 mm Inner Diameter = 10.00 mm 3. Thickness = 1.25 2 = 0.0625 mm From the chart of typical values of overall heat transfer coefficient, we know that for air cooled heat exchanger value of overall heat transfer coefficient (U) ranges from 300-450 W/m 2 K. So here we assume it to be equal to 350 W/m 2 K[42]. U=350 W/m 2 K Using Energy balana equation, ( mc p ) h (T hi T u ) = ( m C p ) c (T ce T ci ) 100 4.187 (52 44) = 525.35 1 (T ce 28) T ce = 34.376 C So outlet temperature of air is = 34.746 C. We know that, q = m w Cp w T w q = 100 4.187 (52 44) q = 3349.6 Watt Assuming the Heat Exchanger (Radiator) to be counter flow we get,

Study, Analysis and Design of Automobile Radiator (Heat Exchanger) 143 Proposed with Cad Drawings and Geometrical Model of the Fan 1 =17.624 C 2 = (44 28) 2 =16 C Substituting these values in equation (5.10) we get, m = 1 2 ln 1 2 m = (17.624 16) ln (17.624 / 16) m = 16.8 C i.e. 289.8 K i.e. LMTD=16.8 C Now, using the average velocity of water in tubes and its flow rate the total flow area is given as, A f = m V Where, A f = Total flow area V = Average velocity of water = Density of water Here, we have average velocity of water = 65 m/hr V=65 m/hr So we get, A f = 100 65 1000 A f = 1.538 10 3 m 2 But we know that, A f = n 4 d2 i Where, n = Number of tubes d i = Inlet diameter of tube

144 Chavan D. K. & Tasgaonkar G. S Substituting respective values, we get 1.538 10 3 = n 4 (10 10 3 ) 2 After solving the above equation we get, n = 19.582 approximate = 20 n=20 For correction factor required dimension parameters are, P = (T ce T ci ) (T hi T ci ) P = 34.376 28 52 28 = 0.3985 R = (T hi T he ) (T ce T ci ) R = 52 44 34.376 28 = 1.26 So referring the chart 5.14, we get value of correction factor as 0.96, F=0.96 That area of the heat transfer after considering correction factor is given as, A = A = q U F m(counterflow) 3349.6 350 0.96 16.8 A=0.5934 m 2 Final Acceptable Design Parameters are as Under Number of tubes per pass = 20 Number of passes = 1 Length of tube per pass = 0.284 m Effectiveness of Heat Exchanger (I) C h = (m Cp) water C h = (100 4.18 1000) 3600 C h =116.306 W/K

Study, Analysis and Design of Automobile Radiator (Heat Exchanger) 145 Proposed with Cad Drawings and Geometrical Model of the Fan (II) C c = (m C p ) air C c = (525.35 1 1000) 3600 C c = 145.931 W/K i.e C min = 116.306 W/K C max = 145.931 W/K Now (a) Capacity ratio (C): C = C min C max C = 116.306 145.931 C = 0.797 (b) NTU : NTU = U A C min NTU = 350 0.5934 116.306 NTU = 1.786 Using NTU- correlation for cross flow HE with both fluids unmixed, we have =1 exp =1 exp 1 C (NTU)0.22 {exp [ C (NTU) 0.78 ] 1} 1 0.797 (1.786)0.22 {exp [ 0.797 (1.786) 0.78 ] 1} =0.6388 So we get effectiveness equal to 0.6388 LIMITATIONS Bending of tubes in circular shape. Inserting of fins in the tubes. Dies are to be manufactured for circular radiators which are exorbitantly costly. CONCLUSIONS Low velocity zones and high temperature regions (low heat transfer regions) are identified in corners we observe that velocity increases with the increase in rpm of radiator fan. For optimum efficiency eliminate corners and develop radiator of Circular shape.

146 Chavan D. K. & Tasgaonkar G. S Design is compact Less material requirement Less power consumption for fan. More efficient. Since material saving is about 24%, cost saving on mass scale production will be about 20%, once the dies are manufactured REFERENCES 1. Cihat Arslanturk & A. Feridum Ozguc, (2006), Optimization of Central heating radiator, Applied Engg, Vol. no. 83, issue 11, pp. 1190-1197. 2. Chen Sun, (2004), Fast Beamforming of Electronically Steerable Parasitic Array Radiator Antennas: Theory and Experiment IEEE transactions on antennas and propagation, vol. 52. 3. JP Yadavand,Bharat Raj Singh,(2011) Study on Performance Evaluation of Automotive Radiator, S-JPSET : ISSN : 2229-7111, Vol. 2, Issue 2. 4. William H Crouse, Automotive Mechanics 10 th edition pp no 318-321 5. Maddiptla, Sridhar, Guessous, Nov (2002), Shape optimization of vehicle radiator using CFD, American Physical Society, Division of Fluid Dynamics, 55th Annual meeting, Vol no. 2, pp 213-222. 6. Max S.Peters and laus D. Timmerhuaus, (1958), Plant Design and Economics for Chemical Engineers, 4th edition, McGraw-Hill Book Company. 7. Prof. John R.Thom, (2004), Wolverine Tube Heat Transfer Data Book III, Wolverine Tube Inc. 8. Arthur P Fraas, Heat Exchanger Design (II Edition) Published by John Wiley& Sons New York, pp no.1-70. 9. Sadik Kakak & Hongtan Lin, Heat Exchangers, Selection, rating, & Thermal design (II edition), pp no 170-181. 10. Ramesh K Shah &Dusan P Sekulic Fundamentals of Heat Exchanger Design pp no 150-175. 11. T Kuppan Heat Exchanger Design Hand book pp no 145-160. 12. Frank P. Incropera David P. DeWitt, 4 th edition Fundamentals of Heat and mass transfer pp no 581-603.