freedom residential flush pendent sprinkler vk476 (K4.9)

Similar documents
TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE

FREEDOM RESIDENTIAL PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK457 (K4.9) TECHNICAL DATA

FREEDOM RESIDENTIAL CONCEALED HORIZONTAL SIDEWALL SPRINKLER VK480 TECHNICAL DATA

freedom residential Upright sprinkler vk467 (k4.9)

Page 1 of 7. Replaces Form No. F_ Rev 16.3 (Added 16X22 and 18X20 coverage areas)

freedom residential concealed pendent Sprinkler vk458 (K7.4)

Page 1 of 7. Form No. F_ Rev Replaces Form No. F_ Rev 17.1 (added 205deg version)

TECHNICAL DATA OBSOLETE

freedom residential concealed pendent sprinkler VK488 (K3.0)

TECHNICAL DATA. * Metric K-factor measurement shown is in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0.

FREEDOM RESIDENTIAL CONCEALED PENDENT LEAD FREE SPRINKLER VK4570 (K4.9) TECHNICAL DATA

freedom residential horizontal sidewall sprinkler Vk450 (k4.2)

freedom residential concealed pendent lead free sprinkler

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

Standard Spray concealed horizontal sidewall sprinkler VK481

freedom residential concealed pendent sprinkler vk474 (K5.8)

Quick response concealed horizontal sidewall sprinkler VK481

HORIZON QUICK RESPONSE FLUSH PENDENT SPRINKLERS TECHNICAL DATA

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK486 (K4.0) TECHNICAL DATA

STANDARD/quick. Sprinkler 42o. August 8, 2011

standard response/qr extended coverage concealed pendent sprinklers vk614 & vk616

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

TECHNICAL DATA. Viking Technical Data may be found on Minimum Operating Pressure: Refer to the Approval Chart.

sprinkler vk538 (K11.2)

mirage standard response concealed pendent sprinkler vk492 (K5.6)

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK479 (K3.0) TECHNICAL DATA

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

HORIZON MIRAGE QUICK RESPONSE LARGE ORIFICE CONCEALED PENDENT SPRINKLER VK406 TECHNICAL DATA

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

mirage Quick response concealed pendent sprinkler vk465 (K4.2)

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK460 (K5.8) TECHNICAL DATA

FREEDOM RESIDENTIAL PENDENT SPRINKLER VK470 (K3.0) TECHNICAL DATA

MIRAGE EC/QREC OH-ELO CONCEALED PENDENT SPRINKLER VK538 (K11.2) TECHNICAL DATA

mirage Quick response concealed pendent sprinkler vk464 (K8.0)

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA

freedom residential horizontal sidewall lead free sprinkler VK4840 (k4.2)

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA

freedom residential pendent sprinkler vk466 (K5.2)

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

TECHNICAL DATA vk470 (K3.0)

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

QUICK RESPONSE FUSIBLE ELEMENT HSW SPRINKLERS VK308 AND HP VK320 (PART NOS AND 13955) TECHNICAL DATA

microfast sr/qr extended coverage pendent sprinkler

Form No. F_ Rev 14.1 Page 1 of 6 TECHNICAL DATA

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA

TECHNICAL DATA. Viking Technical Data may be found on UNS-C84400 for Sprinkler VK202.

TECHNICAL DATA OBSOLETE

FREEDOM RESIDENTIAL PENDENT LEAD FREE SPRINKLER VK4700 (K3.0) TECHNICAL DATA

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK498 (K5.8) TECHNICAL DATA

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

standard/quick response sprinklers (vk302 & vk352) 3. technical data Specifications: Available since Sprinkler 41g May 1, 2009

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA

standard response Fusible Link Upright sprinkler VK204 (K8.0)

MicrofastHP EC/QREC FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK611 (K5.6) TECHNICAL DATA

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK537 (K11.2) TECHNICAL DATA

TECHNICAL DATA. Page 1 of 5

Microfast quick response Fusible element hsw sprinkler

QUICK RESPONSE EXTENDED COVERAGE CONCEALED HSW SPRINKLER VK630 (K8.0) TECHNICAL DATA

STANDARD/QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK352-D (K8.0) TECHNICAL DATA

standard/quick response extended coverage light and ordinary hazard elo sprinklers

TECHNICAL DATA. Refer to Approval Chart 1 and Design Criteria for culus Listing requirements that must be followed.

TECHNICAL DATA. The Viking Corporation s Web site at Overall Length (Sprinkler Body): 2-5/16 (59 mm)

TECHNICAL DATA. Cover Plate Assembly must be ordered separately:

TECHNICAL DATA. Refer to Approval Chart 1 and FM Design Criteria for FM Approval requirements that must be followed.

standard response fusible link sidewall sprinkler VK112 (K5.6)

TECHNICAL DATA. MicrofastHP QUICK RESPONSE FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK318 (K5.6)

quick response sprinkler vk194 Sprinkler 104j January 1, 2011

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

MICROFAST SR/QR EXTENDED COVERAGE HSW SPRINKLER VK605 (K5.6) TECHNICAL DATA

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

quick response horizontal sidewall sprinkler vk360 (K8.0)

microfast quick response extended coverage hsw sprinkler vk606

QUICK RESPONSE DRY CONCEALED PENDENT SPRINKLER VK194 TECHNICAL DATA

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

standard response/ quick response extended coverage

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

quick response Sprinkler 105a October 25, 2010

TECHNICAL DATA. Page 1 of 6

micromatic Standard response Horizontal Sidewall sprinkler

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608

quick response extra-large orifice upright sprinkler vk531 (storage-density/area)

EC/QREC ORDINARY HAZARD UPRIGHT SPRINKLER VK570 (K14.0) TECHNICAL DATA

QUICK RESPONSE EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER VK630 (K8.0) TECHNICAL DATA

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

quick response extended coverage horizontal sidewall sprinkler vk630 (k8.0)

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

micromatic standard response stainless steel sprinklers

standard response large orifice dry

standard response elo upright sprinkler

Transcription:

January 6, 2010 Sprinkler 145h 1. DESCRIPTION Viking Freedom Residential Flush Pendent Sprinkler VK476 is a small high-sensitivity fusible element residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-Factor of 4.9 (70.6 metric*), allows the sprinkler s efficient use of available water supplies for the hydraulically designed fire-protection system. The fast response operating element and special deflector combine speed of operation and areas of coverage to meet residential sprinkler standards. The two-piece design of the sprinkler and ceiling ring allows installation and testing of the sprinkler prior to ceiling installation. The ceiling ring allows for up to 5/8 (16 mm) of vertical adjustment and can be removed and re-installed, allowing access above removable ceiling panels without shutting down the sprinkler system and removing the sprinkler. 2. LISTINGS AND APPROVALS culus Listed: Category VKKW Refer to the Approval Chart and Design Criteria on pages 145j-k for culus Listing requirements that must be followed. 3. technical data Specifications: Available since 2009. Viking Technical Data may be found on Minimum Operating Pressure: Refer to the Approval Chart. The Viking Corporation s Web site at Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically http://www.vikinggroupinc.com. to 500 psi (34.5 bar). The Web site may include a more recent Thread size: 1/2 (15 mm) NPT edition of this Technical Data Page. Nominal K-Factor: 4.9 U.S. (70.6 metric*) *Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. Overall Length: 2-1/8 (54 mm) Material Standards: Sprinkler Body and Inlet: QM Brass Deflector Assembly: Copper UNS-C51000 and Brass UNS-C36000 Pin Assembly: Stainless Steel UNS-S30200 and C23000 Seat Assembly: Brass UNS-C31400 or UNS-C31600 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Fusible Element Assembly: Beryllium Nickel and Eutectic Solder Element Cover: Copper UNS-C11000 Lever Bar Assembly: Copper Alloy UNS-C72500 and Brass UNS-C36000 Lever Arm: Stainless Steel UNS-S31600 Element Assembly: Copper UNS-C11000 and Nickel Alloy Ceiling Ring: Cold Rolled Steel UNS-G10080 Ordering Information: (Also refer to the current Viking price list.) Viking Freedom Residential Flush Pendent Sprinkler VK476 and Ceiling Ring: Part No. 15630MC/- (includes a 165 F (74 C) rated sprinkler with a protective plastic cap covering the unit, and a ceiling ring). Specify finish of the sprinkler and ceiling ring by adding the appropriate suffix for the finish to the base part number: Finish Suffix: Wood Beam Finish = G, Painted White = W, Painted Black = B For example, sprinkler VK476 with a Wood Beam Finish = 15630MC/G. Available Finishes And Temperature Ratings: Refer to Table 1 Form No. F_120608 Replaces page 145h-m, dated Sept. 3, 2009. (Revised sloped ceiling listings.)

Sprinkler 145i January 6, 2010 Accessories: (Also refer to the Sprinkler Accessories section of the Viking data book.) Sprinkler Wrench**: Heavy Duty Wrench Part No. 15209W/R (available since 2009) **Requires a ½ ratchet (not available from Viking). Sprinkler Cabinet: Part No. 01731A, Capacity: five (5) sprinklers (available since 1971) Replacement Ceiling Ring (3 diameter): Base Part No. 15618M/- Specify finish of the ceiling ring by adding the appropriate suffix for the finish to the base part number: Finish Suffix: Wood Beam Finish = G, Painted White = W, Painted Black = B For example, ceiling ring 15618 with a Wood Beam Finish = 15618M/G. 4. Installation Refer to appropriate NFPA Installation Standards. 5. Operation During fire conditions, when the fusible element reaches its operating temperature, the element cover, fusible element and lever assembly fall away. The deflector is suspended below the ceiling. Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pressure at the sprinkler to extinguish or control the fire. 6. inspections, tests and maintenance Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. availability Viking Sprinkler VK476 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. Guarantee For details of warranty, refer to Viking s current list price schedule or contact Viking directly. Figure 1: Sprinkler Installation and Correct Use of Wrench TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating 1 Maximum Ambient Ceiling Temperature 2 Ceiling Ring Base Part Number 3 Ordinary 165 F (74 C) 100 F (38 C) 15618 Finishes: Wood Beam Finish, Painted White, or Painted Black 1 The sprinkler temperature rating is stamped on the sprinkler inlet. Footnotes 2 Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 Part number shown is the base part number for replacement ceiling rings. For complete part number, refer to current Viking price list schedule.

January 6, 2010 Sprinkler 145j Approval Chart Residential Flush Pendent Sprinkler VK476 For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria on page 145k. Sprinkler Base NPT Thread Size Nominal K-Factor Maximum Water Overall Length SIN Part Number 1 Inches mm U.S. metric 2 Working Pressure Inches mm 15630 VK476 1/2 15 4.9 70.6 175 psi (12 bar) 2-1/8 54 Maximum Areas of Coverage 6 Minimum Water Supply Requirements 6 (Refer also to Design Criteria on page 145k.) Listings and Approvals 3,5 culus 4 NYC NSF Installed below smooth, flat, horizontal ceilings and horizontal ceilings with beams. Includes ceilings with slopes up to and including 2/12 (9.5 ). 16 ft. x 16 ft. (4.9 m x 4.9 m) 13 gpm @ 7.0 psi (49.2 L/min @ 0.48 bar) A1 -- -- 18 ft. x 18 ft. (5.5 m x 5.5 m) 17 gpm @ 12 psi (64.4 L/min @ 0.83 bar) A1 -- -- 20 ft. x 20 ft. (6.1 m x 6.1 m) 21 gpm @ 18.4 psi (79.5 L/min @ 1.27 bar) A1 -- -- Installed below ceilings with slopes 7 up to and including a 4/12 (18.4 ) pitch. Refer to Figure 5 on page 145m. UL NYC NSF 16 ft. x 16 ft. (4.9 m x 4.9 m) 18 gpm @ 13.5 psi (68.1 L/min @ 0.93 bar) A1 -- -- 18 ft. x 18 ft. (5.5 m x 5.5 m) 20 gpm @ 16.7 psi (75.7 L/min @ 1.15 bar) A1 -- -- 20 ft. x 20 ft. (6.1 m x 6.1 m) 24 gpm @ 24 psi (90.8 L/min @ 1.65 bar) A1 -- -- Sprinkler Temperature Rating A - 165 F (74 C) Finishes 1 - Wood Beam Finish, Painted White, and Painted Black 8 Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. 3 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 4 Listed by Underwriter s Laboratories for use in the U.S. and Canada. 5 Listings are for residential occupancies with smooth, flat, horizontal ceilings or horizontal ceilings with beams. Includes ceilings with slopes up to and including a 2/12 (9.5 ) pitch. (For beam ceiling design criteria, refer to Beam Ceiling Guidelines and Figures 3 through 4D on pages 145l-m). 6 For areas of coverage smaller than shown, use the Minimum Water Supply Requirement for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the Minimum Water Supply Requirement used. 7 Areas under sloped ceilings must be measured along the ceiling slope. Actual floor coverage in the horizontal plane under sloped ceilings will be less than the listed area of coverage. 8 Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label on the sprinkler body. Figure 2: Sprinkler Dimensions and Ceiling Ring Installation

Sprinkler 145k January 6, 2010 DESIGN CRITERIA (Also refer to the Approval Chart on page 145j.) culus Listing Requirements: When using Viking Residential Flush Pendent Sprinkler VK476 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of coverage and minimum water supply requirements shown in the Approval Chart on page 145j. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: The flow rates given in the Approval Chart on data page 145j for NFPA 13D and NFPA 13R applications for each listed area of coverage, or Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the design area in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. Minimum distance between residential sprinklers: 8 ft. (2.4 m). BEAM CEILING GUIDELINES culus Listed for installation in residential occupancies with beam ceilings (with horizontal ceilings only). Refer to the Approval Chart for sprinkler areas of coverage and hydraulic design. Sprinkler Location: Locate sprinklers on the underside of the beams (not in the bays or pockets formed by the beams). Refer to Figure 3. The vertical distance from the sprinkler deflector to the bottom of the primary beam must be between 1/2 and 1-1/8 (12.7 to 28.5 mm). The horizontal distance from the centerline of the sprinkler to the primary beam cannot be more than 2 (51 mm) (Figure 3). NOTE: Consult with a structural engineer before drilling beams to allow the installation of sprinkler drops. Where drilling is not permitted, sprinkler position requirements allow for the sprinkler drop to be placed adjacent to the primary beam. Beam Position: Directly attached to the underside of a combustible or non-combustible smooth ceiling of any height. Beam Size and Shape (Cross section): Depth: Maximum 14 (355 mm) for primary beams. Secondary beam depth cannot be greater than the primary beam. Width: Unlimited. Beam Shape: Rectangular to circular. Beam Types: Combustible or non-combustible, solid surface, solid or hollow core. Beam Spacing: A. For primary beams, the distance from the wall to the center of the nearest primary beam must be at least 3-4 (1.0 m), and not more than one-half the listed sprinkler spacing. Note: Sprinklers may not be required to be located in the first beam nearest the wall. Center-to-center distance between primary beams is to be a maximum of 20-0 (6.1 m). Refer to Figure 4A. B. When beam pockets created by the primary beams exceed 20-0 (6.1 m) in length, secondary beams are required as follows (also refer to Figure 4B): 1. Secondary beam depth must be equal to primary beam depth. 2. Secondary beams must be placed so that the bays formed by the primary beams do not exceed 20-0 (6,1 m) in length. C. When primary beam spans do not exceed 20-0 (6.1 m), secondary beams (not required) may have any distance from wall to nearest secondary beam and any distance center to center between secondary beams. Refer to Figure 4C. Lintels: Must be present over doorways exiting the compartment. Lintel height must be at least 8 (203 mm), or at least the depth of the primary beams, whichever is greater. Beam and Soffit Arrangements: If a soffit is installed, beams may be arranged within the soffit. The cross section of the soffit may be any size, provided it does not create an obstruction to water distribution per the obstruction rules of NFPA 13 for residential sprinklers. Where there is a soffit, beam spacing from the wall is to be measured from the face of the soffit rather than the wall. Refer to Figure 4D. NOTE: The sprinkler area of coverage is to be measured from the wall. Definitions: Primary beams: The main beams that run primarily in one direction. Secondary beams: The beams that run perpendicular to the main beams. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to pages RES1-17 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction.

January 6, 2010 Sprinkler 145l Figure 3: Sprinkler Positioning Under Primary Beams Figure 4A: Primary Beam Spans up to 20-0 (6.1 m) Figure 4B: Primary Beam Spans over 20-0 (6.1 m)

Sprinkler 145m January 6, 2010 Figure 4C: Combination of Primary and Secondary Beams Figure 4D: Beam and Soffit Arrangements See Note 1 below. Maximum ceiling slope = 4/12 (18.4 ). Refer to the Approval Chart for listed areas of coverage. Notes: 1. Listed areas of coverage correspond to areas measured along ceiling slope. (For sloped ceiling installations, actual floor coverage in the horizontal plane under sloped ceilings will be less than the listed area.) 2. Actual installations may require multiple sprinklers. A single sprinkler installation has been shown for clarity. 3. For cathedral ceiling applications, install sprinklers in a symmetrical mirror-image of Figure 5. Figure 5: Installation Instructions - Sloped Ceilings Form No. F_120608 Replaces page 145h-m, dated Sept. 3, 2009. (Revised sloped ceiling listings.)