Model JL-14 (SIN RA1812) K14.0 (200 metric) Early Suppression Fast Response Sprinkler

Similar documents
Model MBEC-14. Extended Coverage Ordinary & Extra Hazard Horizontal Sidewall Sprinklers for Metal Building Applications. Model MBEC-14 (SIN R6932)

Model F1 LO K 8.0 (115 metric) Standard Response Sprinklers

ESFR PENDENT SPRINKLER VK500 (K14.0) TECHNICAL DATA

Model F1FR Series Quick Response Standard Spray

Model F1 Residential Sprinklers for Design Density of.10 gpm/ft 2

TECHNICAL DATA. * Refer the Approval Charts and Design Criteria on pages 3-5 for culus Listing and FM Approval requirements that must be followed.

esfr pendent sprinkler vk510 (k25.2)

ESFR PENDENT SPRINKLER VK510 (K25.2) TECHNICAL DATA

Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers

Additional Bulletins applicable to all F1RES LL Sprinklers Wall Wetting - Bulletin 007 Design and Installation - Bulletin 140

TECHNICAL DATA. * Refer the Approval Chart on page 120c and Design Criteria on page 120d for culus and FM approval requirements that must be followed.

TECHNICAL DATA NOTICE

esfr pendent sprinkler vk510 (k25.2)

Model G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler

TECHNICAL DATA OBSOLETE. * Refer the Approval Chart on page 121c and Design Criteria on page 121d for FM approval requirements that must be followed.

Model ESFR K-factor Pendent Sprinkler Early Suppression, Fast Response General Description. Sprinkler Identification Number (SIN)

Model G5 Series Sprinkler Summary. Listings and Approvals. G4/G5 QR Gasket culus QR G4/G5 SR Gasket culus, FM SR G4/G5

Sprinkler Guards Model C Model D

Model RFC Series Residential Sprinklers Flat Cover Plate, Concealed Pendent Sprinkler. Product Features. Product Description

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

esfr dry pendent sprinkler Vk502 (k14.0)

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

esfr dry pendent sprinkler Vk501 (k14.0)

TECHNICAL DATA OBSOLETE

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for UL and FM Listing/Approval requirements that must be followed.

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

Residential Sprinkler For Sloped Ceilings

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA

HORIZON QUICK RESPONSE FLUSH PENDENT SPRINKLERS TECHNICAL DATA

Series ELO K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage General Description

Standard Spray concealed horizontal sidewall sprinkler VK481

MicrofastHP EC/QREC FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK611 (K5.6) TECHNICAL DATA

TECHNICAL DATA. Page 1 of 5

Form No. F_ Rev 14.1 Page 1 of 6 TECHNICAL DATA

TECHNICAL DATA. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2009 NYC Approved: MEA E, Volume 3

microfast sr/qr extended coverage pendent sprinkler

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

microfast quick response extended coverage hsw sprinkler vk606

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

QUICK RESPONSE EXTENDED COVERAGE CONCEALED HSW SPRINKLER VK630 (K8.0) TECHNICAL DATA

QUICK RESPONSE EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER VK630 (K8.0) TECHNICAL DATA

quick response extended coverage horizontal sidewall sprinkler vk630 (k8.0)

QUICK RESPONSE ELO PENDENT SPRINKLER VK377 (STORAGE-DENSITY/AREA) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617

STANDARD/QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK352-D (K8.0) TECHNICAL DATA

freedom residential flush pendent sprinkler vk476 (K4.9)

Sprinkler Identification Numbers

standard response elo upright and pendent sprinklers (storage-density/area)

standard response/qr extended coverage concealed pendent sprinklers vk614 & vk616

freedom residential concealed pendent sprinkler VK488 (K3.0)

STANDARD/quick. Sprinkler 42o. August 8, 2011

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK457 (K4.9) TECHNICAL DATA

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

standard response fusible link sidewall sprinkler VK112 (K5.6)

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

freedom residential concealed pendent lead free sprinkler

TECHNICAL DATA. MicrofastHP QUICK RESPONSE FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK318 (K5.6)

TECHNICAL DATA. Viking Technical Data may be found on UNS-C84400 for Sprinkler VK202.

Microfast quick response Fusible element hsw sprinkler

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK479 (K3.0) TECHNICAL DATA

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA

TECHNICAL DATA. Page 1 of 6

Quick response concealed horizontal sidewall sprinkler VK481

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK537 (K11.2) TECHNICAL DATA

TECHNICAL DATA. Cover Plate Assembly must be ordered separately:

freedom residential concealed pendent sprinkler vk474 (K5.8)

Model ESFR-25 Early Suppression, Fast Response Pendent Sprinklers 25.2 K-factor General Description

INSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

Page 1 of 7. Form No. F_ Rev Replaces Form No. F_ Rev 17.1 (added 205deg version)

TECHNICAL DATA OBSOLETE

standard response/ quick response extended coverage

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7

standard response elo upright sprinkler

TECHNICAL DATA. * Metric K-factor measurement shown is in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0.

standard response dry horizontal sidewall sprinklers

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

Page 1 of 7. Replaces Form No. F_ Rev 16.3 (Added 16X22 and 18X20 coverage areas)

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

MICROFAST SR/QR EXTENDED COVERAGE HSW SPRINKLER VK605 (K5.6) TECHNICAL DATA

MIRAGE EC/QREC OH-ELO CONCEALED PENDENT SPRINKLER VK538 (K11.2) TECHNICAL DATA

FREEDOM RESIDENTIAL CONCEALED HORIZONTAL SIDEWALL SPRINKLER VK480 TECHNICAL DATA

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

FREEDOM RESIDENTIAL CONCEALED PENDENT LEAD FREE SPRINKLER VK4570 (K4.9) TECHNICAL DATA

standard response Fusible Link Upright sprinkler VK204 (K8.0)

quick response horizontal sidewall sprinkler vk360 (K8.0)

TECHNICAL DATA OBSOLETE

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA

sprinkler vk538 (K11.2)

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA

mirage standard response concealed pendent sprinkler vk492 (K5.6)

microfast quick response Pendent sprinkler VK302 (K5.6)

EC/QREC ORDINARY HAZARD UPRIGHT SPRINKLER VK570 (K14.0) TECHNICAL DATA

Transcription:

Bulletin 018 Rev. H Model JL-14 (SIN RA1812) K14.0 (200 metric) Early Suppression Fast Response Sprinkler Bulletin 018 Rev. H Product Description The Reliable Model JL-14 Early Suppression Fast Response (ESFR) Sprinkler is intended for use against severe fire challenges. This sprinkler is designed to respond quickly to growing fires and will deliver a heavy water discharge to suppress rather than control fires. Note: The Model JL-14 ESFR sprinkler utilizes a levered fusible alloy solder link in either a 165 F (74 C) or a 212 F (100 C) rating. FM Global considers this a Quick Response storage sprinkler for use in Data Sheet 8-9. The sprinkler has a Nominal K Factor of 14.0 (metric 200) and will deliver approximately 100 gpm (378 L/min) of water at 50 psi (3,5 bar). The deflector and frame provide a broad, very symmetrical, hemispherical pattern capable of suppressing fires between sprinklers in high storage height areas and at the same time retaining a high momentum central core to penetrate and suppress fires occurring directly beneath the sprinkler in low storage height areas. Application and Installation The Model JL-14 ESFR sprinkler is intended for installation in accordance with NFPA 13 and FM Loss Prevention Data Sheets 2-0 and 8-9 as well as the Authority Having Jurisdiction. This sprinkler is intended for protection of palletized and solid piled and open frame single row, double row, multiple row and portable rack storage of most common materials including unexpanded and cartoned expanded plastics. The JL-14 ESFR sprinkler was designed to be shorter, and more compact than other ESFR sprinklers. The shorter sprinkler allows piping to be installed further from the ceiling and obstructions. The JL-14 ESFR sprinkler is also less susceptible to damage due to smaller deflector and frame design. The lighter JL-14 ESFR passed rough use and abuse test in the labs without plastic protectors. The Model JL-14 ESFR Sprinkler is FM approved when installed in accordance with Factory Mutual Loss Prevention Data Sheet 8-9 and Data Sheet 2-0 and other FM Installation Standards. The Model JL-14 ESFR Sprinkler is UL Listed and Certified for Canada for installation in accordance with NFPA 13 Standards. Model JL-14 ESFR Sprinkler Design Criteria General guidelines: Orientation: Pendent. Deflector should be parallel with the ceiling or roof. System Type: Wet Pipe Systems Only Maximum area of coverage: 100 ft 2 (9,3m 2 ), greater coverage area are allowable in some cases. Minimum area of coverage: 64 ft 2 (5,8m 2 ) Maximum slope ceiling: 2/12 pitch (9.5 ) Maximum spacing: 12 ft (3,7m) for building heights up to 30 ft (9,1m) and 10 feet (3,1m) for building heights greater than 30 ft (9,1m) Minimum spacing: 8 feet (2,4m) Deflector distance from walls: At least 4 inches (102mm) from walls, and no more than one-half the allowable distance permitted between sprinklers. Deflector to Top of Storage: at least 36in (914mm). Deflector to ceiling Distance: 6-14 in (152-356mm) per NFPA 13. 5-14 in (121-35mm) per FM 2-2. Center Line of Thermal Sensing Element To Ceiling Distance: 4-13 in (102-330mm) per FM Listings and Approvals 1. Listed by Underwriters Laboratories Inc. and UL certified for Canada (culus) 2. FM Approved as a storage sprinkler 3. VdS Schadenverhütung GmbH (VdS) 4. Loss Prevention Certification Board (LPCB) 5. CNBOP-PIB Technical Approval Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523

Model JL-14 Ratings Classification Ordinary Intermediate Installation Data Sprinkler Type Pendent Only Thread Size Sprinkler Maximum Ceiling Link Frame Color Color F C F C 165 74 Black Uncolored 100 38 212 100 White White 150 66 Nominal K Factor US Metric Maximum Working Pressure Finish ¾ (R¾) 14.0 200 175 psi (12,1 bar) Bronze Maintenance The Model JL-14 ESFR Sprinkler should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinkler with soap and water, ammonia or any other cleaning fluid. Replace any sprinkler that has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used, to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Once operated, automatic sprinklers cannot be reassembled and reused. New sprinklers of the same size, type and temperature rating must be installed. A cabinet of replacement sprinklers should be provided for this purpose. Model JL-14 ESFR Sprinkler Specification Sprinklers shall be Early Suppression Fast Response (ESFR) pendent suppression mode sprinklers specifically tested and [UL Listed] [FM Approved] for commodity storage applications. Sprinkler frame and deflector to be of bronze construction. Fusible link assembly shall utilize the strut and lever principle of operation with approved fast response black-painted or white-painted beryllium-nickel thermal element. Water seal shall consist of a Electroless Nickel PTFE coated Bellville spring washer and brass cap assembly containing no plastic parts. ESFR sprinklers shall have a nominal K-factor of 14.0 with ¾ NPT threaded end connections. Sprinkler temperature rating shall be [Ordinary 165 F (74 C)] [Intermediate 212 F (100 C)]. ESFR pendent sprinklers shall be Reliable Model JL-14 (Bulletin 018). Model J1 Sprinkler Wrench Sprinkler Identification Number (SIN) RA1812 Use only the Model J1 sprinkler wrench for removal and installation. Any other type of wrench may damage the sprinkler. Note: Sprinklers should be tightened between 14-20 ft-lbs (19-27,1 N-m) torque. Sprinklers not tightened to recommended torque may cause leakage or impairment of the sprinklers. Damage sprinklers must be replaced immediately. Ordering Information Specify: 1. rating 2. Thread type 3 /4 NPT or ISO 7-R 3 /4 Note: Grooved sprinkler boss provided to ensure that the sprinkler wrench does not slip during installation. The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 11/17 P/N 9999970378

Features: 1. culus, VdS, and LPCB listed as a nominal K16.8 (240 metric) ESFR sprinkler. 2. FM Approved as a quick-response, storage and non-storage, sprinkler. 3. Fusible link operating element. 4. Compact design allows piping to be installed farther from the ceiling and obstructions compared with larger sprinklers. Listings and Approvals 1. Listed by Underwriters Laboratories Inc. and UL certified for Canada (culus) - Category Code VNWH. 2. FM Approved as a quick-response, storage and nonstorage, sprinkler. 3. VdS Schadenverhütung GmbH (VdS). 4. Loss Prevention Certification Board (LPCB). 5. CNBOP Technical Approval. Bulletin 019 Rev. H Model JL-17 (SIN RA1914) K16.8 (240 metric) Early Suppression Fast Response Sprinkler Model JL-17 ESFR Sprinkler Bulletin 019 Rev. H Product Description The Reliable Model JL-17 Early Suppression Fast Response (ESFR) Sprinkler with a nominal k-factor of 16.8 (240 metric). This sprinkler is designed to respond quickly to growing fires and will deliver a heavy water discharge to suppress rather than control fires. FM Global classifies the Model JL-17 as a quick-response sprinkler, storage and non-storage, when the sprinkler is used in accordance with FM Global Property Loss Prevention Data Sheets. The Model JL-17 ESFR sprinkler utilizes a levered fusible alloy solder link in either a 165 F (74 C) or a 212 F (100 C) rating. Model JL-17 sprinklers are culus Listed for compliance with UL/ULC 1767, including the high clearance test for rack storage. The Model JL-17 ESFR sprinkler was designed to be shorter and more compact than other ESFR sprinklers. The shorter sprinkler allows piping to be installed farther from the ceiling and obstructions. The JL-17 ESFR sprinkler is also less susceptible to damage due to smaller deflector and frame design. The lighter JL-17 ESFR passed rough use and abuse listing tests without plastic protectors. Application and Installation The Model JL-17 ESFR sprinkler is intended for installation in accordance with NFPA 13 and FM Loss Prevention Data Sheets 2-0 and 8-9, as well as the requirements of any Authorities Having Jurisdiction. See Table 1 for information on NFPA and FM Global design criteria for the Model JL-17 sprinkler. Use only the Model J1 sprinkler wrench for removal and installation. Any other type of wrench may damage the sprinkler. A grooved wrench boss is provided on the sprinkler to limit the potential for the wrench to slip during installation. Model J1 Sprinkler Wrench When handling sprinklers, hold sprinklers only on frame arms and do not apply any force on the link assembly. Sprinklers should be tightened between 14-40 ftlbs (19-54 N-m) torque. Sprinklers not tightened to recommended torque may cause leakage or impairment of the sprinkler. Damage sprinklers must be replaced immediately. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523

Ratings and Approvals Classification Rating Link Frame Maximum Ambient F C Color Color F C Ordinary 165 74 Black Uncolored 100 38 Intermediate 212 100 White White 150 66 Approvals culus, FM, VdS, LPCB, CNBOP culus, FM, VdS, LPCB, CNBOP Sprinkler Identification Number (SIN) RA1914 Installation Data Sprinkler Type Thread Size Nominal K- Factor US Metric Maximum Working Pressure Finish Pendent ¾ (R¾) 16.8 240 175 psi (12.1 bar) Bronze Installation Criteria The following general guidelines are provided for information only. NFPA and, where applicable, FM Global standards shall be consulted for complete design and installation criteria. Orientation: Pendent, deflector should be parallel with the ceiling or roof. System Type: Wet Pipe Systems Only. Maximum area of coverage: 100 ft 2 (9.3m 2 ), greater coverage areas are allowable in some cases. Minimum area of coverage: 64 ft 2 (5.8m 2 ). Maximum slope ceiling: 2/12 pitch (9.5 ). Maximum spacing: 12 ft (3.7m) for building heights up to 30 ft (9.1m) and 10 feet (3.1m) for building heights greater than 30 ft (9.1m). Minimum spacing: 8 feet (2.4m). Deflector distance from walls: At least 4 inches (102mm) from walls, and no more than one-half the allowable distance permitted between sprinklers. Deflector to Top of Storage: at least 36 in (900mm). Deflector to ceiling Distance: 6-14 in (150-350mm) per NFPA 13. Center Line of Thermal Sensing Element To Ceiling Distance: 2-13 in (50-330mm) for smooth ceilings or 4-13 in (100-330mm) for nonsmooth ceilings per FM Data Sheet 2-0. Maintenance The Model JL-17 ESFR Sprinkler should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinkler with soap and water, ammonia or any other cleaning fluid. Replace any sprinkler that has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used, to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Once operated, automatic sprinklers cannot be reassembled and reused. New sprinklers of the same size, type and temperature rating must be installed. A cabinet of replacement sprinklers should be provided for this purpose. 2. Model JL-17 ESFR Sprinkler Specification Sprinklers shall be Early Suppression Fast Response (ESFR) pendent sprinklers specifically tested and [culus Listed] [FM Approved] [VdS Approved] [LPCB Approved] for commodity storage applications. Sprinkler frame and deflector to be of bronze construction. Fusible link assembly shall utilize the strut and lever principle of operation with approved fast response black-painted or white-painted beryllium-nickel thermal element. Water seal shall consist of a PTFE coated Bellville spring washer and brass cap assembly containing no plastic parts. ESFR sprinklers shall have a nominal K-factor of 16.8 (240 metric) with [¾ NPT] [ISO 7-R¾] threaded end connections. Sprinkler temperature rating shall be [Ordinary 165 F (74 C)] [Intermediate 212 F (100 C)]. ESFR pendent sprinklers shall be Reliable Model JL-17 (Bulletin 019). Ordering Information Specify: 1. Sprinkler: Model JL-17 2. rating: [Ordinary 165 F (74 C)] [Intermediate 212 F (100 C)] 3. Thread type: [ 3 /4 NPT] [ISO 7-R 3 /4]

Storage Type NFPA FM Open Frame (that is, no solid shelves) Single, Double, Multiple-Row, or Portable Rack Storage of Class I-IV and Group A or B Plastics Solid Pile or Palletized Storage of Class I-IV and Group A or B Plastics Idle Pallet Storage Rubber Tire Storage Rolled Paper Storage (Refer to the standard) Chapters 16 and 17. Chapters 14 and 15. Chapter 12. Chapter 18. Chapter 19. Refer to FM 2-0 and FM 8-9. Refer to FM 2-8 and FM 8-9. Refer to FM 2-0 and FM 8-24. Refer to FM 2-0 and FM 2-0 and FM 8-3. Refer to FM 8-21. Flammable Liquid Storage (Refer to standard) Refer to NFPA 30. N/A Aerosol Storage (Refer to the standard) Refer to NFPA 30B. Refer to FM 7-31. Automotive Components In Portable Racks (Control mode only; refer to the standard) Chapters 20. N/A TABLE 1 COMMODITY SELECTION AND DESIGN CRITERIA OVERVIEW FOR MODEL ESFR-17 PENDENT SPRINKLERS 3.

Reliable...For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 11/17 P/N 9999970379