Automatic Sprinklers

Similar documents
Automatic Sprinklers

UL LISTED. SPRINKLER HEADS IN STOCK: Pendent Upright Horizontal sidewall Concealed. RESPONSE Quick response Standard response

MODEL: FA003U FA004U FA005P FA006P STANDARD SPRAY, STANDARD QUICK RESPONSE, 5 3 mm BULB TYPE, K5.6, 1/2" CONNECTING THREAD

MODEL: FA007C FA008C STANDARD SPRAY, STANDARD QUICK RESPONSE, 5 3 mm BULB TYPE, K5.6, 1/2" CONNECTING THREAD WRENCH FLAT

Model ELOC 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick and Standard Response, Extended Coverage

ESCUTCHEON PLATE SEATING 3/4" NPT SURFACE. 1-1/2" (38,1 mm) CROSS SECTION PENDENT RECESSED PENDENT

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

Page 1 of 8 DECEMBER 2018 TFP408. Worldwide Contacts.

RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Domed-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

RAPID RESPONSE Series LFII Residential 4.9 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe and Dry Pipe Systems General Description

Sprinkler Identification Numbers. TY3351 Horizontal TY3451 Vertical. Technical Data

Sprinkler Identification Number TY ECLH HSW, 8.0K, 3/4"NPT

Sprinkler Identification Numbers

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

WRENCH FLATS NPT 1/2" 7/16" (11,1 mm) NOMINAL MAKE-IN. 1-1/2" (38,1 mm) 2-3/16" (55,6 mm) WRENCH NPT. (12,7 mm) NOMINAL MAKE-IN.

Series TY-FRB 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall Wet Pipe and Dry Pipe Systems General Description

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage

ILLUSION 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description

The Series LFII (TY3596) Residential

RAPID RESPONSE Series LFII Residential Sprinklers 5.6 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Flat-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

Model CHEC 8.0 K-factor Concealed Horizontal Extended Coverage Quick Response Light Hazard, Sidewall Sprinklers General Description

* Temperature rating is FIGURE K-FACTOR QUICK RESPONSE SERIES TY-FRB HORIZONTAL SIDEWALL (TY3331) SPRINKLERS

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

Sprinkler Identification Number. Page 1 of 6 AUGUST 2018 TFP288. Worldwide Contacts.

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response)

FIGURE 1 MODEL RFIII ECLH CONCEALED HSW SPRINKLER ASSEMBLY AND FEATURES. 5/16" (7,9 mm) MIN. 9/16" (14,3 mm) MAX.

special request FACTORY ASSEMBLED UPRIGHT WITH SCREW FIELD ASSEMBLED MODEL S2 SHIELD (SEE INSTALLATION SECTION) WRENCH FLATS *

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description

Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

O-RING UPRIGHT SHIELD WRENCH FLATS WRENCH FLATS FIGURE 1 SERIES TY-B UPRIGHT (TY3153) AND PENDENT (TY3251) SPRINKLERS

Sprinkler Identification Numbers

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Pendent Wet Pipe and Dry Pipe Systems General Description

ESCUTCHEON PLATE SEATING SURFACE. 1-11/16" (42,7 mm) CROSS SECTION

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Sprinkler Identification Number (SIN) TY4234. Page 1 of 8 APRIL 2012 TFP Technical Services

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

Series RFII 5.6 K-factor. Flush II Concealed Pendent Sprinklers

Submittal Packages Detailed with Items and Reviewers

Model/Sprinkler Identification Number JULY, 2011 WARNINGS

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Horizontal Sidewall Wet Pipe Systems

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

Model/Sprinkler Identification Numbers

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

Sprinkler Identification Number (SIN)

Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design)

Model TY-FRFS, TY-FS Special, and TY-FS 57, 80, and 115 K-factor Upright and Pendent Flat Spray Sprinklers General Description

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

Series LFII Residential Pendent Sprinklers 4.9 K-factor General Description

Data Sheet 4.24 Issue F

Series LFII Residential Sprinklers Flat-Plate Concealed Pendent 4.9 K-Factor General Description

Model ESFR K-factor Pendent Sprinkler Early Suppression, Fast Response General Description. Sprinkler Identification Number (SIN)

Model TY-FRFS, TY-FS Special, and TY-FS Flat Spray Sprinklers, Upright and Pendent 57, 80, and 115 K-factor General Description

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard)

Commercial Flat Concealed Sprinkler, Pendent, Quick Response, Extended Coverage (Light Hazard) Model: RC-QR-EC, K-Factor: 5.

Exaggerated for Clarity. Residential Pendent, Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date

Data Sheet 4.16 Issue D

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

TECHNICAL DATA. * Metric K-factor measurement shown is in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0.

SENJU SPRINKLER CO., LTD.

40.43 V38, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Low Flow Adjustable Concealed Pendent V3806 QUICK RESPONSE

SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description

Series DS-1 Dry-Type Sprinklers 5.6K Pendent, Upright, and Horizontal Sidewall Quick Response, Standard Coverage General Description

Series LFII Residential Flush Pendent Sprinklers 4.2 K-factor General Description

Residential Lead Free Flat Concealed Sprinkler, Pendent, Model: RC-RES, K-Factor: 4.9, SIN: SS8461

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK498 (K5.8) TECHNICAL DATA

mirage standard response concealed pendent sprinkler vk492 (K5.6)

freedom residential concealed pendent sprinkler vk474 (K5.8)

Series ELO-231 Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

40.50 V38, K5.6. Adjustable Concealed Standard Spray Pendent Standard and Quick Response

40.49 V27, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Horizontal Sidewall, Recessed Horizontal Sidewall V2744 QUICK RESPONSE

STANDARD/quick. Sprinkler 42o. August 8, 2011

Residential Flat Concealed Sprinkler, Pendent, Model: CN-RES, K-Factor: 4.9, SIN: SS8421

DISCONTINUED PRODUCT

standard response/qr extended coverage concealed pendent sprinklers vk614 & vk616

Model WS TM 5.6 K-factor Specific Application Window Sprinklers, Horizontal and Pendent Vertical Sidewall General Description

Commercial Flat Concealed Sprinkler, Pendent, Quick & Standard Response, Standard Coverage, Model: CN-QR, K-Factor: 5.

SENJU SPRINKLER CO., LTD.

Data Sheet 4.19 Issue C

Transcription:

CONCEALED PENDENT SPRINKLERS MODEL: BZ007 / BZ008 STANDARD SPRAY, STANDARD / QUICK RESPONSE, 5 / 3 mm BULB TYPE, K5.6, 1/2" CONNECTING THREAD GENERAL DESCRIPTION The BZ007/BZ008 Standard/Quick Response Concealed Pendent Sprinklers (Ref. Figure A) are automatic sprinklers of the frangible bulb type. They are standard/quick response standard orifice spray sprinkler intended for use in fire sprinkler systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on NFPA 13 requirements). The Concealed Pendent Sprinklers all produce a hemispherical water distribution pattern below the deflector. This model sprinkler includes a Cover Plate Assembly that conceals the sprinkler operating components above the ceiling. The Cover Plate Assembly, which installs onto the Sprinkler/ Mounting Cup Assembly, consists of a Cover Plate that is soldered to an Enclosure at three equidistant locations around their peripheries. The Ejection Spring is located between the flange of the Enclosure and the Cover Plate, to ensure separation of the two pieces when the solder melts. A Label located on the Cover Plate Assembly indicates the nominal temperature of the sprinkler and the nominal diameter of the Glass Bulb. The small Cover Plate is flat with a low profile that blends in with the ceiling for an aesthetically pleasing appearance. Standard finishes for the Cover Plate are satin chrome plated and painted white. Other factory applied painted finishes for the Cover Plate is available on special order. The separable two-piece design of the Cover Plate and Mounting Cup Assemblies allows installation of the sprinklers and pressure testing of the fire protection system prior to installation of a suspended ceiling or application of the finish coating to a fixed ceiling. The separable design also permits removal of suspended ceiling panels for access to building service equipment, without having to first shut down the fire protection system and remove sprinklers. Also, the separable twopiece design of the BZ007/ BZ008 Concealed Sprinkler provides for 1/6 inch (4.2mm) of vertical adjustment, to reduce the accuracy to which the length of fixed pipe drops to the sprinklers must be cut.

1. FRAME 2.MOUNTING CUP 3.BUTTON 4.SPRING SEAL 5.GLASS BULB 6.ENCLOSURE 7. SET SCREW 8.DEFLECTOR 9.COVER PLATE 10.EJECTION SPRING 11.LABEL FIGURE A: MODEL BZ007/BZ008 CONCEALED PENDENT SPRINKLER SPRINKLER OPERATION During a fire conditions, the sufficient ambient temperature will fuse the solder between the Cover Plate and the Enclosure. The Cover Plate will fall away from the Enclosure, to expose the Sprinkler for operation. Then the thermal-sensitive liquid in the Sprinkler s Glass Bulb expands, causing the Bulb to shatter, releasing the Button and Spring Seal Assembly. Water flowing through the sprinkler orifice strikes the Sprinkler Deflector, forming a uniform spray pattern to extinguish or control the fire. COVERAGE For coverage area and sprinkler placement, refer to NFPA13 standards. TECHNICAL SPECIFICATIONS Model & Sprinkler I.D. No. 1 BZ007 BZ008 Style Concealed Pendent Response & Bulb Nominal Dia. Standard Response, Ø5mm Quick Response, Ø3mm Thread Size [Optional] NPT1/2 or R1 2 2 Nominal Orifice Size 1/2 Inch Nominal K-Factor 1 5.6 (U.S.) 80 (metric) Max. Working Pressure 175 psig 1.2 MPa (12 bar) Factory Hydrostatic Test 100% @ 500psig (3.4 MPa) Min. Operating Pressure 7 psig 0.048 MPa (0.48 bar) Sprinkler Finish [Optional] Natural Brass or Chrome Plated Cover Plate Finish Painted White or Chrome Plated or Color Coated In Any Color Listings and Approvals 3 UL(United States) ULC(Canada) AVAILABLE TEMPERATURE RATING Temp. Classification Ordinary Ordinary Intermediate Intermediate Nominal Temp. Rating 135 F 57 C 155 F 68 C 175 F 79 C 200 F 93 C Max. Ambient Temp. Allowed 5 115 F 46 C 135 F 57 C 155 F 68 C 180 F 82 C Max. Recommended Ambient Temp. 6 100 F 38 C 100 F 38 C 150 F 65 C 150 F 65 C Glass Bulb Color 7 Orange Red Yellow Green

Footnotes: 1 Sprinkler I.D. Nos. and nominal U.S. K-factors provided in accordance with the 2002 edition of NFPA 13. 2 The pipe thread connections accord with ISO7/1. 3 This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4 UL and ULC Listed for both Light-Hazard and Ordinary-Hazard occupancies. 5 Based on National Fire Prevention and Control Administration Contract No. 7-34860. 6 Based on NFPA 13. Other limits may apply depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 7 The temperature rating is stamped on the deflector or adjacent to orifice seat on frame. SPRINKLER MATERIALS Frame Deflector Set Screw Button Glass Bulb Spring Seal Mounting Cup Enclosure Cover Plate Ejection Spring Label ACCESSORIES Installation Wrench Type T-1 Bronze Forging UNS-C87400 Brass UNS-28000 Brass UNS-28000 Brass UNS-28000 Glass with Glycerin Solution, JOB G5 for BZ007 JOB F3 for BZ008 Stainless Steel Teflon Tape Low Carbon Sheet Steel UNS-G10080 Brass UNS-C28000 Brass UNS-C28000 Stainless Steel UNS-S30452 Mylar (Sticky-back) DISCHARGE COEFFICIENT Model BZ007/BZ008 Concealed Pendent Sprinklers are rated for use at a maximum service pressure of 175 psig (12 bar). The nominal discharge curve plotted in Figure B represents the flow Q in GPM (LPM) as determined by the following formula: DISCHARGE IN U.S. GALLONS PER MINUTE (GPM) PRESSURE IN POUNDS PER SQUARE INCH (PSIG) 10 30 50 70 90 110 130 150 170 280 70 PARTIAL CURVE ONLY MAX. PRESSURE 175 PSIG 260 65 240 60 220 55 200 50 180 45 160 40 35 140 30 120 25 100 20 80 15 60 10 5 0 0.2 ü NOMINAL K=5.6 ý NOMINAL K=80 0.4 0.6 PARTIAL CURVE ONLY MAX. PRESSURE 1.2 MPA 0.8 1.0 1.2 PRESSURE IN MPA FIGURE B : NOMINAL DISCHARGE CURVE Q=K(P) 0.5 Where: Q Flow, GPM (LPM) K Discharge Coefficient, K=5.6 (80) P Discharge Pressure, psig (bar) Listing standards permit the actual value of K to vary from 5.3 to 5.8 (76,4 to 83,6); however, for hydraulic calculations, a K-factor of 5.6 (80) is to be applied. WARNING The Model BZ007/BZ008 Concealed Pendent Sprinklers described herein must be installed and maintained in compliance with this document, as well as applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the integrity of these devices. 40 20 DISCHARGE IN LITERS PER MINUTE (LPM)

The Model BZ007/BZ008 Concealed Pendent Sprinklers must not be used in applications where the air pressure above the ceiling is greater than that below. Downdrafts through the Mounting Cup could delay sprinkler operation in a fire condition. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or manufacturer should be contacted relative to any questions. INSTALLATION NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontal, a small air bubble should be present. Only use the Model T-1 Sprinkler Wrench for installation of the BZ007/BZ008 sprinkler. Do not wrench on the sprinkler other than as shown in Figure C. The Model BZ007/BZ008 Concealed Pendent Sprinklers must be installed in accordance with the following instructions. 1. Prior to installing the sprinklers, if applicable, verify that the face of the sprinkler fitting is within the proper range of distance. 2. Remove the Cover Plate Assembly and Protective Cup if there has. The Protective Cap helps prevent damage to the Sprinkler Deflector and Frame during ceiling installation and/or during application of the finish coating of the ceiling. 3. With pipe thread sealant applied to the pipe threads, over the sprinkler threads, hands tighten the sprinkler into the sprinkler fitting. 4. Refer to Figure C and select the appropriate Sprinkler Wrench, such as Model T-1 Wrench, for tightening the sprinkler into the sprinkler fitting. Carefully remove the Sprinkler Wrench by disengaging it from the sprinkler wrench flats, and then lowering it down over the sprinkler deflector. FIGURE C: SPRINKLER WRENCH SELECTION & USE NOTES A leak tight 1/2 pipe thread sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9.5 to 19.0 Nm). A maximum of 21 ft.lbs. (28.5 Nm) of torque is to be used to install the sprinkler. Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Push on the Sprinkler Wrench, while it is being turned, to ensure that the Wrench recess stays fully engaged with the sprinkler wrench flats. Do not attempt to make-up for insufficient adjustment in the Sprinkler Assembly by

under-or-over-tightening the Sprinkler/Mounting Cup Assembly. Readjust the position of the sprinkler fitting to suit. 5. Refer to Figure D and replace the Protective Cap by pushing it upwards until it bottoms out against the Mounting Cup. The Protective Cap may also be used to locate the center of the clearance hole by gently pushing the ceiling material up against the center point of the Cap. After the Ceiling has been completed with the 2-1/2 inch (64 mm) to 2-13/16 inch (72 mm) diameter clearance hole, remove and discard the Protective Cap, and verify that the Sprinkler is intact. If the BZ007/BZ008 Sprinkler has been damaged, please replace the entire Sprinkler assembly. Do not attempt to modify or repair a damaged sprinkler. 6. Install on the Cover Plate Assembly until its flange just comes in contact with the ceiling. Do not continue to install on the Cover Plate Assembly such that it lifts a ceiling panel out of its normal position. If the Cover Plate Assembly cannot be engaged with the Mounting Cup or the Cover Plate Assembly cannot be engaged sufficiently to contact the ceiling, the Sprinkler has been positioned incorrectly and must be repositioned according to Step No.1. PRO E CAP TECTIV FIGURE D: FIGURE E : MODEL BZ007/BZ008 CONCEALED PENDENT SPRINKLER TYPICAL INSTALLATION

CARE AND MAINTENANCE Automatic sprinklers must never be shipped or stored where their temperatures will exceed 100 F/38 C and they must never be painted, plated, coated or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers - both before and after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb (ref. Installation Section Note). If a sprinkler must be removed for some reason, do not reinstall it or a replacement without reinstalling the Cover Plate Assembly. If a Cover Plate Assembly becomes dislodged during service, replace it immediately. NOTES Absence of the Cover Plate Assembly may delay the time to sprinkler operation in a fire situation. When properly installed, there is a nominal 3/32 (2.4mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure E. This air gap is necessary for proper operation of the sprinkler. If the ceiling is to be repainted after the installation of the BZ007/BZ008 sprinkler, care must be exercised to ensure that the new paint does NOT seal off any of the air gap. Factory painted Cover Plates MUST NOT be repainted. They should be replaced, if necessary, by factory painted units. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Before closing a fire protection system control valve for maintenance work on the fire protection system, which it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. It is recommended that automatic sprinkler systems be inspected quarterly by a qualified Inspection Service. ORDERING PROCEDURE A Product Symbol Number (PSN) shall be specified when ordering sprinklers. And it is suggested that a color chip be provided when ordering special color coated Cover Plates. Otherwise, responsibility for duplication cannot be accepted. Contact your local distributor for availability. Sprinkler Assemblies: Specify: 1/2" orifice, (specify temperature rating), Model BZ007/BZ008 Concealed Pendent sprinklers with (specify type of finish), PSN (specify as follows). PSN 0151 53 X 1 X 2 X 3 Sprinkler Response and X 1 Nominal Temperature Rating 1 135 F 57 C Standard Response 2 135 F 57 C Quick Response 3 155 F 68 C Standard Response 4 155 F 68 C Quick Response 5 175 F 79 C Standard Response 6 175 F 79 C Quick Response 7 200 F 93 C Standard Response 8 200 F 93 C Quick Response Thread Size, Sprinkler Finish and X 2 Cover Plate Finish 1 NPT1/2, Natural Brass & Painted White 2 NPT1/2, Natural Brass & Chrome Plated 3 NPT1/2, Chrome Plated & Painted White 4 NPT1/2, Chrome Plated & Chrome Plated 5 R1 2 Natural Brass & Painted White 6 R1 2 Natural Brass & Chrome Plated 7 R1/2, Chrome Plated & Painted White 8 R1/2, Chrome Plated & Chrome Plated X 3 1 CCC Listings and Approvals 2 UL ULC Accessories:

Order the following accessories, as applicable: Type T-1 Wrench: PSN 0159 2100 WEIGHT The nominal weights are as follows. 1/2" Orifice Model BZ007/ BZ008 Concealed Pendent 6.0 ozs. (170 g) T-1 Sprinkler Wrench 18 ozs. (510 g) CONVERSION TABLE Name of Unit Unit Conversion Symbol Factor Millimeter mm 1 in.=25.4 mm Square meter m 2 1 ft 2 =0.0929 m 2 Liter L 1 gal=3.785 L Cubic decimeter dm 3 1 gal=3.785 dm 3 Cubic meter m 3 1 ft 3 =0.0283 m 3 Kilogram kg 1 lb=16 ozs.=0.4536 kg Kilograms per cubic meter Kg/m 3 1 lb/ft 3 =16.0183kg/m 3 Pascal Pa 1 psi=6895 Pa Bar bar 1 psi=0.0689 bar Newton meter N m 1 ft lbs=1.355 N m This! WARNING product must be installed by an experienced, trained installer, in accordance with the instructions provided with each valve. These instructions contain important information. Failure to follow these instructions may result in serious personal injury, property damage, or valve leakage. We reserve the right to change product specifications, designs and standard equipment without notice and without incurring obligations. If you have any questions about the safe installation and use of this device, contact Ponmani International India Private Limited., No.33,Jeenis Road, Saidapet, Chennai 600 033. INDIA