High Ceiling Protection

Similar documents
FIRE PROTECTION FOR NON-STORAGE OCCUPANCIES WITH HIGH CEILING CLEARANCES

Significant Advancements in Water Based Fire Suppression for Storage Occupancies

E x t E N d e d Co v e r ag e S p r i n k l e r s. Office Buildings Hotels Hospitals Libraries. High-Piled Storage Big-Box Retailing

The Effect of Large Orifice Sprinklers on High-Challenge Fires

Storage Sprinkler U.S. Quick Reference Guide

Storage Protection Using Horizontal Barriers and Large K-Factor, Extended Coverage In-Rack Sprinklers

TECHNICAL DATA OBSOLETE

TECHNICAL DATA. * Refer the Approval Chart on page 120c and Design Criteria on page 120d for culus and FM approval requirements that must be followed.

ESFR PENDENT SPRINKLER VK500 (K14.0) TECHNICAL DATA

Model ESFR K-factor Pendent Sprinkler Early Suppression, Fast Response General Description. Sprinkler Identification Number (SIN)

STORAGE FIRE PROTECTION SPRINKLERS

Box-in-Box Cold Storage Fire Protection Options

standard response elo upright and pendent sprinklers (storage-density/area)

TECHNICAL DATA. * Refer the Approval Charts and Design Criteria on pages 3-5 for culus Listing and FM Approval requirements that must be followed.

TECHNICAL DATA NOTICE

TECHNICAL DATA OBSOLETE. * Refer the Approval Chart on page 121c and Design Criteria on page 121d for FM approval requirements that must be followed.

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

SPRINKLER TECHNOLOGY:

esfr pendent sprinkler vk510 (k25.2)

Model JL-14 (SIN RA1812) K14.0 (200 metric) Early Suppression Fast Response Sprinkler

Sprinkler Identification Numbers

A sprinkler operates automatically when the heat-actuated element is heated to, or above, its thermal rating.

ESCUTCHEON PLATE SEATING SURFACE. 1-11/16" (42,7 mm) CROSS SECTION

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA

Model MBEC-14. Extended Coverage Ordinary & Extra Hazard Horizontal Sidewall Sprinklers for Metal Building Applications. Model MBEC-14 (SIN R6932)

ESFR PENDENT SPRINKLER VK510 (K25.2) TECHNICAL DATA

Non-Storage / Special Protection / Storage Sprinklers

esfr pendent sprinkler vk510 (k25.2)

esfr dry pendent sprinkler Vk502 (k14.0)

standard/quick response extended coverage light and ordinary hazard elo sprinklers

Factors Affecting Efficiency of Water Mist Suppression of Solid Combustible Fires in Open Environment

Series ELO K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage General Description

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

FIRE EXTINGUISHER SPACING & INSTALLATION GUIDELINES

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

Sprinkler Identification Numbers

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

Sprinkler Identification Number. Page 1 of 6 AUGUST 2018 TFP288. Worldwide Contacts.

Fire Protection in High-rise Buildings

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for UL and FM Listing/Approval requirements that must be followed.

Sprinkler Solutions for Storage Applications

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

Watermist Applications and Approvals

Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Today's Topics & Sustainability Themes

Model/Sprinkler Identification Number JULY, 2011 WARNINGS

WRENCH FLATS NPT 1/2" 7/16" (11,1 mm) NOMINAL MAKE-IN. 1-1/2" (38,1 mm) 2-3/16" (55,6 mm) WRENCH NPT. (12,7 mm) NOMINAL MAKE-IN.

SCHULTE & ASSOCIATES Building Code Consultants 880D Forest Avenue Evanston, IL /

TECHNICAL DATA. Cover Plate Assembly must be ordered separately:

esfr dry pendent sprinkler Vk501 (k14.0)

The Science Behind Water Mist Protection of Typical Building Hazards

Developing a Fire Test Strategy for Storage Protection Under Sloped Ceilings

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

standard response elo upright sprinkler

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage

Model ESFR-25 Early Suppression, Fast Response Pendent Sprinklers 25.2 K-factor General Description

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

ESCUTCHEON PLATE SEATING 3/4" NPT SURFACE. 1-1/2" (38,1 mm) CROSS SECTION PENDENT RECESSED PENDENT

STANDARD/quick. Sprinkler 42o. August 8, 2011

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

HORIZON MIRAGE QUICK RESPONSE LARGE ORIFICE CONCEALED PENDENT SPRINKLER VK406 TECHNICAL DATA

STANDARD/QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK352-D (K8.0) TECHNICAL DATA

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

TECHNICAL DATA. Page 1 of 5

Storage Sprinkler. Model LP-46 (SIN) V4603, K25, Standard Response Storage Upright Sprinkler, Patent Pending

NFPA 30 FLC-SWC Public Comment Report

Model G5 Series Sprinkler Summary. Listings and Approvals. G4/G5 QR Gasket culus QR G4/G5 SR Gasket culus, FM SR G4/G5

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Model ESFR-17 Early Suppression, Fast Response Upright Sprinklers 16.8 K-factor General Description

mirage Quick response concealed pendent sprinkler vk465 (K4.2)

TECHNICAL DATA. * Metric K-factor measurement shown is in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0.

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

TECHNICAL DATA. Viking Technical Data may be found on UNS-C84400 for Sprinkler VK202.

TECHNICAL DATA. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2009 NYC Approved: MEA E, Volume 3

Page 1 of 8 DECEMBER 2018 TFP408. Worldwide Contacts.

HORIZON QUICK RESPONSE FLUSH PENDENT SPRINKLERS TECHNICAL DATA

RESEARCH TECHNICAL REPORT. SMART Sprinkler Protection for Highly Challenging Fires - Phase 2: Full-Scale Fire Tests in Rack Storage

MIRAGE EC/QREC OH-ELO CONCEALED PENDENT SPRINKLER VK538 (K11.2) TECHNICAL DATA

The Loss prevention Council. Phase 1 report

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

standard/quick response sprinklers (vk302 & vk352) 3. technical data Specifications: Available since Sprinkler 41g May 1, 2009

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK534 (K11.2)

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

standard response/ quick response extended coverage

freedom residential concealed pendent sprinkler vk474 (K5.8)

Series TY-FRB 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description

MICROFAST AND MicrofastHP QUICK RESPONSE PENDENT SPRINKLERS TECHNICAL DATA

IMO. 4 June 1999 GUIDELINES FOR THE APPROVAL OF ALTERNATIVE FIXED WATER-BASED FIRE-FIGHTING SYSTEMS FOR SPECIAL CATEGORY SPACES

S p e c i a l P u r p o s e S p r i n k l e r s. Attic Spaces Retail Windows High Security Institutions Minimal Water Damage Conditions

Sprinkler Identification Numbers

microfast and microfasthp quick conventional sprinklers

RESIDENTIAL SPRINKLER INSTALLATION GUIDE

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Flat-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Domed-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

mirage Quick response concealed pendent sprinkler vk464 (K8.0)

TECHNICAL DATA OBSOLETE

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040

Transcription:

High Ceiling Protection

High Ceiling Protection An Investigation of Automatic Sprinkler Protection of Buildings with Non-Storage Occupancies and High Clearances Company Confidential 2

Background New architectural designs create real fire protection challenges to fire engineers. The Taller seems to be The Better Sprinkler performance and effectiveness in buildings with high roofs and nonstorage occupancies such as atria, convention centers, casinos auditoriums, theaters, exposition halls and others, is not well understood. Project conducted by FMG Research at the 18.3 m high ceiling FM test site in Rhode Island, USA 3

A Series of Tests to answer Questions related to Sprinkler Performance Need to investigate the adequacy of the different approaches for protection in FM Global Data Sheet 3-26 prior to Jan. 2005 Tests results to answer: Will automatic sprinklers ever operate? What would be the ceiling temp.? What type of sprinkler and design criteria to use and will sprinklers be effective in controlling the fire? Will skipping be a factor in the performance of the sprinkler (sprinkler in the fire area being cooled by adjacent activated sprinklers preventing it from operating) 4

FM Global Property Loss Prevention Data Sheets 3-26 - 2005 5

FM Global Property Loss Prevention Data Sheets 3-26 - 2005 6

Goals of the FM Test Program Conduct 5 full scale fire tests at the Factory Mutual facility to investigate sprinkler performance in Ordinary Hazard, non-storage buildings with high clearances, up to 60 ft. (18.3 m). building height containing potential fuel stacks lower than 10 ft (3 m high). 7

Description of Full Scale Fire Test 1 Fuel Arrangement: FMRC Class 2 commodity Fuel Height: 2.26 m Clearance to ceiling: 15.4 m Arrangement of fuel package: 8 by 8, solid pile, 2 tiers Density: 12 mm/min Sprinklers: K115, RTI 140 (m-s) 1/2 Standard Response, Upright Spacing: 3.0 m x 3.0 m 8

FMRC CLASS II Commodity-Fuel Package Metal lined double tri wall corrugated carton on a wood pallet 9

Side View of Fuel Array Class II Group A Plastics 10

Plan View of Fuel Array Test 1 11

Plan View of Sprinkler Operation Test 1 12

Temperature Measurements in Test 1 13

Results Test 1 Number of Sprinklers Operated: 15 Ceiling temperature: Within acceptable limits Fire Damage: Fire well confined to ignition array Skipping of sprinklers: Considerable Key Take Away: According to the criteria given, very favorable results were achieved for the moderately loaded hazard. In view of the good results, the same level of protection can be extended to Class III commodity 14

Description of Full Scale Fire Test 2 Fuel Arrangement: FMRC Class 2 commodity Fuel Height: 2.26 m Clearance to ceiling: 15.4 m Arrangement: 8 by 8, solid pile, 2 tiers Density: 6 mm/min Sprinklers: K= 80, RTI 140 (m-s) 1/2 Standard Response, Upright Spacing: 3.0 m x 3.0 m 15

Plan View of Sprinkler Operation Test 2 16

Results Test 2 Number of sprinklers Operated: 17 Ceiling temperature: Within acceptable levels Fire damage: Fire well confined to ignition array Skipping of sprinklers: Observed. Key Take Away: According to the criteria given, reasonable performance was achieved for the moderately loaded hazard. 17

FMRC Cartoned Unexpanded Group A Plastics 16 oz Polystyrene Plastic Jars in compartmented cardboard cartons 18

Side View of Fuel Array Class II Group A Plastics 19

Plan View of Fuel Array Test 3 & 4 20

Description of Full Scale Fire Test 3 Fuel Arrangement: FMRC Group A Plastics Fuel Height: 1.73 m Clearance to ceiling: 15.9 m Arrangement: 2 by 8, solid pile, 1 tier Density: 12 mm/min Sprinklers: K115, RTI 140 (m-s) 1/2 Standard Response element, Upright Spacing: 3.0 m x 3.0 m 21

Plan View of Sprinkler Operation Test 3 22

Results Test 3 Number of Sprinklers Operated: 26! Skipping of Sprinklers: extreme Test terminated at 9 minutes before it yielded conclusive results Key Take Away: Test failed 23

Description of Full Scale Fire Test 4 Fuel Arrangement: FMRC Group A Plastics Fuel Height: 1.73 m Clearance to ceiling: 16.6 m Arrangement: 2 by 8, solid pile, 1 tier Density: 18 mm/min Sprinklers: QR/ELO, K= 160, RTI 28 (m-s) 1/2 Response element, Upright Spacing: 3.0 m x 3.0 m Fast 24

Plan View of Sprinkler Operation Test 4 25

Temperature Measurements in Test 4 26

Results Test 4 Number of sprinklers operated: 16 Ceiling temperature: Within acceptable levels Fire damage: Fire well confined to ignition array Skipping of sprinklers: Severe Key Take Away: in Heavily Loaded areas, ELO sprinklers with 12mm/min over an operating area of 230 sqm is effective against the fire hazard equivalent to the limited amount of FMRC Standard Plastic Commodity 27

Description of Full Scale Fire Test 5 intended to provide a reference point for future work Fuel Arrangement: FMRC Group A Plastics identical to test4 Fuel Height: 1.73 m Clearance to ceiling: 16.6 m Clearance to deflector: 16.4 m Arrangement: 2 by 8, solid pile, 1 tier Density: 18 mm/min Sprinklers: K= 360 (EC-25), RTI 28 (m-s) 1/2 Fast Response element, Upright Spacing: 6.1 m x 6.1 m 28

EC-25 (Extended Coverage Extra Hazard Sprinkler) Control Mode (Density/Area) Extended Coverage K-factor 360 LPM/bar 1/2 RTI: 28 (m-s)1/2 Fast Response element Temperature Ratings 74 C or 101 C Position: Upright Finish: Natural Brass Pipe Thread Connection: 1 NPT or ISO 7-R1 29

Plan View of Sprinkler Operation Test 5 30

Results Test 5 1 Number of Sprinklers Operated: Ceiling temperature: Within acceptable levels Fire damage: Fire well confined to ignition array No Skipping of sprinklers since only one operated Key Take Away: Favorable results, fire losing intensity at 2 min. 10s., one head operating, fire well confined but additional test needed to verify protection scheme 31

Test Summary Test 1 Test 2 Test 3 Test 4 Exploratory Test 5 EC 25 Commodity (as per NFPA) Class II & III Class II Group A Plastic Group A Plastic Group A Plastic Fuel Height 2.26 2.26 1.73 1.73 1.73 Ceiling 15.4 15.4 15.9 16.6 16.6 Deflector 15.2 15.2 15.7 16.4 16.4 Arrangement 8X8,solid, 2 tiers 8X8,solid, 2 tiers 2X8, solid, 1 tier 2X8, solid, 1 tier 2X8, solid, 1 tier density 12 mm/min 6 mm/min 12 mm/min 18 mm/min. 18 mm/min. K-factor K115, RTI 140 K 80, RTI 140 K115, RTI 140 K 160, RTI 28 K 360, RTI 28 Spacing 3.0 X 3.0 3.0 X 3.0 3.0 X 3.0 3.0 X 3.0 6.1 X 6.1 Conclusion Passed Passed Failed Passed 1 head operating 15 heads operating 17 heads operating 26 heads operating 16 heads operating No skipping Skipping Adequate Skipping Adequate Skipping Skipping Adequate Needs further research 32

Conclusion #1: Results validated but more Research needed 1. For the test conditions, automatic sprinkler design criteria of 6 mm/min over 232 m 2 was validated for moderately loaded areas equivalent to Class II, 12 mm/min was validated for moderately loaded areas equivalent to Class III 18 mm/min over 232 m 2 criteria was validated for heavily loaded areas 2. However, high clearances induce temporary or permanent skipping of automatic sprinklers and more work is needed to evaluate its effect on fire control 33

Conclusion #2: Even more Research needed! 3. Preliminary results seem to demonstrate that: Large Orifice : A K-factor of 360 at 18mm/min discharge density ensures large droplet sizes sufficient to penetrate the fire plume, Extended Coverage: Spacing of up to 6X6 m. reduces skipping, Fast Response element is required at larger spacing to guarantee early operation, From the tests, the EC25 offers an efficient protection scheme for high ceiling clearances of up to 18.3 m 34

DS 3 26 Table 2, 2a and EB 04 12. Standard Coverage, EC and K25.2 Sprinkler Design Demands for Hazard Categories Hazard Category DS 3 26 Table 2, 2a and EB 04 12. Standard Coverage, EC and K25.2 Sprinkler Design Demands for Hazard Categories Standard Coverage Sprinkler Design Demand (gpm/ft2)/ft2 (mm/min)/m2 Sprinkler Type Standard Coverage Sprinkler Design Demand (gpm/ft2)/ft2 (mm/min)/m2 Ceiling Height up to 30 ft (9 m) Ceiling Height 30 45 Ceiling Height 45 60 ft (9 13.5 m) ft (13.5 18 m) Ceiling Height 60 100 ft (18 30 m) Wet Dry Wet Dry Wet Dry Wet Dry 0.1/1500 (4/140) 0.1/1500 (4/140) 0.2/2500 (8/230) 0.2/3500 (8/330) 0.2/2500 (8/230) 0.2/3500 (8/330) See Table 2a EC Pendent Sprinklers 160 F (70 C) K11.2EC (K160EC) 0.1/1500 (4/140) EC Pendent Sprinklers 160 F (70 C) K14.0EC (K200EC) 0.1/1500 (4/140) HC 1 EC Pendent Sprinklers 160 F (70 C) K25.2EC (K360EC) 6 @ 7 psi (0.5) 6 @ 7 psi (0.5) 6 @ 7 psi (0.5) 6 @ 7 psi (0.5) Pendent Sprinklers QR 160 F (70 C) K25.2 (K360) 12 @ 7 psi (0.5) 12 @ 7 psi (0.5) 12 @ 7 psi (0.5) 12 @ 7 psi (0.5) EC Upright Sprinklers 160 F (70 C) K11.2EC (K160EC) 0.1/1500 (4/140) 0.2/2500 (8/230) EC Upright Sprinklers 160 F (70 C) K14.0EC (K200EC) 0.1/1500 (4/140) 0.2/2500 (8/230) Company Confidential 35

DS 3 26 Table 2, 2a and EB 04 12. Standard Coverage, EC and K25.2 Sprinkler Design Demands for Hazard Categories Hazard Category DS 3 26 Table 2, 2a and EB 04 12. Standard Coverage, EC and K25.2 Sprinkler Design Demands for Hazard Categories Sprinkler Type Standard Coverage Sprinkler Design Demand (gpm/ft2)/ft2 (mm/min)/m2 Standard Coverage Sprinkler Design Demand (gpm/ft2)/ft2 (mm/min)/m2 Ceiling Height up to 30 ft (9 m) Ceiling Height 30 45 Ceiling Height 45 60 ft (9 13.5 m) ft (13.5 18 m) Ceiling Height 60 100 ft (18 30 m) Wet Dry Wet Dry Wet Dry Wet Dry 0.2/2500 (8/230) 0.2/3500 (8/330) 0.2/2500 (8/230) 0.2/3500 (8/330) 0.2/2500 (8/230) 0.2/3500 (8/330) See Table 2a EC Pendent Sprinklers 160 F (70 C) K11.2EC (K160EC) EC Pendent Sprinklers 160 F (70 C) K14.0EC (K200EC) 0.2/2500 (8/230) HC 2 EC Pendent Sprinklers 160 F (70 C) K25.2EC (K360EC) 6 @ 7 psi (0.5) 6 @ 7 psi (0.5) 6 @ 7 psi (0.5) 6 @ 7 psi (0.5) Pendent Sprinklers QR 160 F (70 C) K25.2 (K360) 12 @ 7 psi (0.5) 12 @ 7 psi (0.5) 12 @ 7 psi (0.5) 12 @ 7 psi (0.5) EC Upright Sprinklers 160 F (70 C) K11.2EC (K160EC) 0.3/1500 (12/140) 0.2/2500 (8/230) EC Upright Sprinklers 160 F (70 C) K14.0EC (K200EC) 0.3/1000 (12/90) 0.2/2500 (8/230) Company Confidential 36

DS 3 26 Table 2, 2a and EB 04 12. Standard Coverage, EC and K25.2 Sprinkler Design Demands for Hazard Categories Hazard Category DS 3 26 Table 2, 2a and EB 04 12. Standard Coverage, EC and K25.2 Sprinkler Design Demands for Hazard Categories Sprinkler Type Standard Coverage Sprinkler Design Demand (gpm/ft2)/ft2 (mm/min)/m2 Standard Coverage Sprinkler Design Demand (gpm/ft2)/ft2 (mm/min)/m2 Ceiling Height up to 30 ft (9 m) Ceiling Height 30 45 Ceiling Height 45 60 ft (9 13.5 m) ft (13.5 18 m) Ceiling Height 60 100 ft (18 30 m) Wet Dry Wet Dry Wet Dry Wet Dry 0.3/2500 (12/230) 0.3/3500 (12/330) 0.3/3600 (12/340) 0.3/4600 (12/430) 0.5/3000 (20/280) 0.5/4000 (20/370) See Table 2a EC Pendent Sprinklers 160 F (70 C) K11.2EC (K160EC) EC Pendent Sprinklers 160 F (70 C) K14.0EC (K200EC) 0.3/2500 (12/230) HC 3 EC Pendent Sprinklers 160 F (70 C) K25.2EC (K360EC) 6 @ 7 psi (0.5) 6 @ 7 psi (0.5) 6 @ 7 psi (0.5) 6 @ 7 psi (0.5) Pendent Sprinklers QR 160 F (70 C) K25.2 (K360) 12 @ 7 psi (0.5) 12 @ 7 psi (0.5) 12 @ 7 psi (0.5) 12 @ 7 psi (0.5) EC Upright Sprinklers 160 F (70 C) K11.2EC (K160EC) 0.3/1500 (12/140) 0.3/2500 (12/230) EC Upright Sprinklers 160 F (70 C) K14.0EC (K200EC) 0.3/1000 (12/90) 0.3/2500 (12/230) Company Confidential 37

FM 3-26 July 2011 Updated EB 04-12 FM 3 26 July 2011 Table 1. Hazard Categories Based on Occupancy Occupancy Description of Occupancy Exceptions HazardCategory Apartments Atriums Churches Concealed spaces Gymnasiums Hospitals and hospital laboratories Hotel rooms Ins tu ons Kitchens Libraries Mee ng rooms in conven on centers and hotels Metalworking shops with nonhydraulic cu ng opera ons Mineral processing such as: glass, cement, ore treating, gypsum processing, etc. Museums Nursing or convalescent homes Offices Restaurant sea ng areas Schools and universities classrooms Unused a cs Lightly loaded nonstorage and nonmanufacturing areas with ordinary combustibles. Expect fires with relatively low rates of heat release in these occupancies. Libraries with stack rooms larger in size than defined in Appendix A; Facilities with storage of electronic and plastic media (see DS 8 9 ). Hospital laboratories where exposed storage and processing of flammable liquids is considered excessive (see the applicable flammable liquids data sheet). Facilities with operations involving hydraulic fluid or flammable liquid, see DS7 32, DS 7 29, and DS 7 98; and for storage, see DS 7 32, DS 7 29, and DS 7 98. HC 1 Company Confidential 38

FM 3-26 July 2011 Updated EB 04-12 FM 3 26 July 2011 Table 1. Hazard Categories Based on Occupancy Occupancy Description of Occupancy Exceptions HazardCategory Auto parking garages Back stage of theaters and auditoriums Boat mfg. and assembly Boiler buildings Casinos Clubs Conven on centers Display halls Electronicelectrical mfg. and assembly Food processing Leather tanning and working Mercan le areas Metalworking shops with hydraulic opera ons Movie and TV Studios Paper processing Retail areas Rubber processing Sports Arenas Theater & auditoriums* U lity and equipment rooms Lightly and moderately loaded nonstorage, nonmanufacturing, and manufacturing areas with ordinary combustibles. Occupancies with fire hazards equivalent to in process Class 2 commodities no more than 6 ft (1.8 m) high, or lesser hazard (e.g., mostly wood, cardboard products and small amounts of plastic, including foam plastic found in the seat cushion of a chair or plastic trim in an exhibit display booth). Manufacturing occupancies with movable picking racks not higher than 6 ft (1.8 m) containing rigid plastic open top containers. Do not allow expanded plastic inside the containers. Additionally, if the racks/carts are not separated by at least a distance equal to the least dimension of the rack/cart, treat as storage per DS 8 9. Operations involving hydraulic fluid or flammable liquid (see DS 7 32, DS 7 29, and DS 7 98); aluminum rolling mills (see DS 7 64/13 28); paper machine areas that involve inks with flashpoints below 110 F (42 C) (see DS 7 4 and DS 7 96); aircraft hangars (see DS 7 93N). Oil cookers and distilling operations (see the applicable flammable liquid data sheet). Bulk retailers where merchandise is displayed on racks typically found in warehouses (see DS 8 9 and DS 8 3). Telephone switchgear rooms and generator rooms (see DS 5 12, DS 5 14, or DS 5 23). HC 2 Company Confidential 39

FM 3-26 July 2011 Updated EB 04-12 FM 3 26 July 2011 Table 1. Hazard Categories Based on Occupancy Occupancy Description of Occupancy Exceptions Hazard Category Cable manufacturing Carsized vehicle repair garages and assembly operations where vehicles are repaired, tested, or assembled with relatively small amounts of fuel in tanks Interior loading docks Modular building subassembly Plas cs processing and molding Highway trailers, trucks, boxcars, some mobile homes or similar metal vehicles with combustible interiors with the potential for shielded fire Heavily loaded areas with or without plastics. Manufacturing and nonmanufacturing facilities with higher concentrations of combustibles or shielding of combustibles where the fire hazard could approach the equivalent of nominal 5 ft (1.5 m) high in process storage of cartoned unexpanded plastic commodities. Facilities that use hydraulic and flammable liquids (see DS 7 98). For electronic media storage see DS 8 9. For haultruck repair shops or manufacturing facilities housing vehicles that may contain several hundred gallons of flammable liquid, see DS 7 12 or DS7 32, as applicable. HC 3 Company Confidential 40

Questions 4 1

Thank You Company Confidential 42