ABOUT US OUR EXPERTISE WHAT IS ENERGY RECOVERY? ERV (Energy Recovery Ventilation) AHU (Air Handling Units) PAC (Package Air Conditioning Equipment)

Similar documents
The ultimate fresh air solution.

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

AHU INSTALLATION & OPERATION MANUAL

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

Pthey are comfortable. In regions with hot

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Energy Recovery Ventilation

Energy Recovery with Cooling and Heating Model ERCH

Energy Recovery with Cooling and Heating

The ultimate in air handling units: directly and indirectly fired

PRODUCT SERIES. VPR Series VPRX Series VPRE Series VPRP Series VPRC Series

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

PRODUCT RANGE: ROOFTOP PACKAGE

Why should you opt for ENTHALPY. Wheels for your. AHUs. ERVs. (Energy Recovery Ventilators) (Air Handling Units) from

Submittal Data Performance Data Electrical Data

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION

CHAPTER 4. HVAC DELIVERY SYSTEMS

The ultimate in air handling units: directly and indirectly fired

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

FACTORY INSTALLATION (CW-160) Indirect evaporative air conditioner 100% outside air

AHU ENERGY RECOVERY VENTILATORS ERV DEDICATED OUTDOOR AIR SYSTEMS DOAS HEATING, COOLING & DEHUMIDIFICATION AHU

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

DEHUMIDIFICATION: Ice Arena Application & Product Guide. Design, construct and operate to control indoor humidity in ice rinks

Pool heating, efficiently

Are uncontrollable humidity problems costing you a bundle?

Indirect Evaporative Air Conditioning

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

PoolPak MPK Series. PoolPak.com. Environmental Control Systems REDUCED FOOTPRINT & WEIGHT COMPARED TO EARLIER GENERATIONS

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Indoor Swimming Pools:

Heat pump and energy recovery systems

Multi-Denco. » Precision Climate Control. Air Conditioning & Heating. Multi-DENCO

Complete Ventilation, Heat Recovery and Dehumidification Packaged System by. Maintaining Your Climate for Indoor Pools and Waterparks

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

Product Release Summary

Munters Heat Exchangers

Indirect Evaporative Air Conditioning

The ultimate in air handling units: directly and indirectly fired

DES CHAMPS PRODUCTS 85% 4,400 CFM

Double Skin Air Handling Units

Indirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160)

The ultimate in air handling units: directly and indirectly fired

Humidity Control Systems for Civil Buildings in Hot Summer and Cold. Winter Zone in China

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

BARD MANUFACTURING COMPANY, INC. W18AA-W72AB

Air Cooled Packaged Systems AIRAH Back to Basics

INTRODUCTION. Heat Pipe Technology, Inc. The Heat Pipe Principle. Recent Heat Pipe Development

Desiccant Dehumidifier

Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

MECHANICAL SERVICES 101. Ian White

Trane Performance Climate Changer Air Handlers. An air handler for every need.

VariCool VAV. (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water. Unique Solutions for All-Indoor HVAC Projects

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

FACTORY INSTALLATION (CW-160) Indirect evaporative air conditioner 100% outside air

Update Dedicated Heat Recovery Chiller Technology. Don Frye. Gulf South

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 11/11/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

Dehumidifying with Dedicated Outdoor Air

DESCRIPTION APPLICATIONS MD800S SUPPLY MODULE

The New Sorption Rotary Heat Exchanger

Daikin Blueprint: Delivering Hot Water with a Chiller

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

Designing Energy Efficient Outdoor Air Systems

Section 4 of 6 DOAS Core Technologies

THE ULTIMATE ROOFTOP SOLUTION

Trane Performance Climate Changer Air Handlers. An air handler for every need.

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

Flexible & Innovative. Cooling Solutions

Enriching Environments

Commercial Evaporative Air Conditioning

recooler HP EQKR HEAT PUMP

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

» WITH REGASORP ROTARY HEAT EXCHANGER

product application data PERFECT HUMIDITY DEHUMIDIFICATION SYSTEM

AIR HANDLING UNITS ZHK 2000

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

EP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT

Bill McCullough. Director ERV Products. Dallas, TX

Ventilation in Humid Climates: Data from Field Experiments

100% Outdoor Air Dehumidification Methods

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001

AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM TO m3/h

Appendix 13. Categories of Cooling and Heating systems

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

CI/SfB X. DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION

AHRI Guideline W (I-P) 2014 Guideline for Selecting, Sizing, & Specifying Packaged Air-to-Air Energy Recovery Ventilation Equipment

CASE STUDY AIR-CONDITIONERS

DF-IDF air handling units

Commercial Evaporative Cooling

... DF / IDF Gas fired combined heating and ventilation ...

Advance Release September 2009

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

SPACE CONDITIONING IN COMMERCIAL BUILDINGS Overview

Transcription:

COMPANY PROFILE

ABOUT US THE LEADERS IN AIR TO AIR HEAT RECOVERY. ARMCOR AIR SOLUTIONS IS A DYNAMIC, PROFESSIONAL COMPANY RESPECTED BY THE AIR CONDITIONING INDUSTRY FOR OUR TRACK RECORD IN PROVIDING ADVICE, QUALITY EQUIPMENT, AND WELL-BALANCED SUPPORT. OUR EXPERTISE ERV (Energy Recovery Ventilation) AHU (Air Handling Units) PAC (Package Air Conditioning Equipment) We invite you to partner with Armcor, the leaders in innovative ERV, Heat recovery Equipment and AHU solutions and experience the satisfaction of personalised support from concept design through to on-time delivery. WHAT IS ENERGY RECOVERY? Every occupied building needs fresh air. Whenever fresh air is introduced there is an opportunity to recover heat from the exhaust air. This transfer process is Energy Recovery. With the spirally costs of power, reducing consumption and recovering energy is vital. The pre-treatment of fresh air has become a major consideration for building developers, owners, occupiers and HVAC consultants. Armcor Air Solutions are here to provide the solutions. 2 ARMCOR COMPANY PROFILE

OUR CONTINUOUS IMPROVEMENT PROGRAM SIMPLIFY easier to specify and select REDUCE LEAD TIMES easier to purchase IMPROVE DESIGN easier to install INCREASED EFFICIENCY environmentally responsible COMPANY VALUES INTEGRITY Transparent, honest and ethical HARD WORK Committed hard working team that achieves results INITIATIVE Solution focused, forward thinking and well planned CUSTOMER The centre of everything we do CARE Positive attitude where everyone is valued ACCOUNTABILITY Achieving the outcome correctly, thoroughly, and efficiently 2018 ABOUT US 3

PAC ENERGY RECOVERY UNITS Packaged Airconditioning ERV XEP 500 8000 The XEP series combines the efficiency of energy recovery integrated with a packaged air conditioning system to provide a total solution to temperature control for applications that require substantial or full fresh air. The unit configuration suits external rooftop or ground level applications and include energy saving EC Plug Fans and the option of enthalpy or sensible heat exchange media. Standard capacities range from 500 l/sec to 8,000 l/sec with cooling capacity up to 160kw. Equipment can be specifically designed for larger applications up to 18,000 l/sec. High Efficiency PAC ERV XEPH 500 8000 Armcor s High Efficiency range of Package Airconditioning ERV gives optimum efficiency using: Digital Compressors(s) / Variable Refrigerant Technology (VRT) / Peak Demand Control / Tri-Capacity (Three Stage Operation) Swimming Pool ERV XES 300 8000 The XES series is a packaged air conditioning system with energy recovery that is particularly suited for applications where there is the requirement to provide full fresh to indoor swimming pool areas. Designed with the specific need to overcome condensation and the corrosive nature of the chlorine laden air, the XES PAC unit includes EC Plug Fans, in-built filters and polypropylene plate heat exchange media. The cabinet and components are lined with a corrosion resistant coating. An optional economy system is easily accommodated to allow bypass for both fresh and exhaust air. PROJECT APPLICATIONS & OPTIONS APPLICATIONS INCLUDE Commercial Public Activity Venues, Sporting Complexes and Gymnasiums Public Utility Buildings, Police, Ambulance Stations Nursing Homes, Child Care, Education Large Occupancy Buildings and Retail Showrooms Professional Suites OPTIONS Economy Cycle Various control options 4 ARMCOR COMPANY PROFILE

Below: To provide the auditorium at Loreto Mendeville Hall with quality conditioned air for the performances and large gatherings of students, two Armcor packaged ERV units were selected giving a total of 5000 l/sec of air with 112 kw of cooling capacity. 2018 PAC ENERGY RECOVERY UNITS 5

ENERGY RECOVERY External Mount ERV XEM 500 8000 The XEM series is our standard heat recovery ERV solution for rooftop, ground level or plant room applications. These units utilize the Xchange plate heat exchanger to recover energy from the exhaust air and transfer it to the incoming fresh air, resulting in significant energy savings. Both enthalpy and sensible heat exchange media are available. The XEM Series is particularly suited to an optional economy bypass system. Forward curve centrifugal fans provide initial cost savings and are available in models up to 1500 L/sec. EC Plug fans provide speed control and add energy savings and are available in all models. External Mount ERV with Hot/Chilled Water Coils XEC 500 8000 The XEC series combines ERV with inbuilt chilled water and/or hot water coils to condition the air following the heat recovery process. The unit configuration suits external rooftop or plant room applications and is available with forward curved centrifugal fans or energy saving EC Plug Fans and an option of enthalpy or sensible plate heat exchange media. PROJECT APPLICATIONS & OPTIONS APPLICATIONS INCLUDE Commercial Public Activity Venues, Sporting Complexes and Gymnasiums Public Utility Buildings, Police, Ambulance Stations Nursing Homes, Child Care, Education Large Occupancy Buildings and Retail Showrooms Professional Suites OPTIONS Enthalpy or Sensible Media Hot and Chilled Water Coils Economy Cycle Various control options 6 ARMCOR COMPANY PROFILE

Top: Energy recovery equipment provides Regis Aged Care, Port Coogee with the best air treatment available in Australia. 2018 ENERGY RECOVERY 7

CEILING MOUNTED UNITS Ceiling Mount ERV XCM 80 1200 The XCM series is a compact, horizontal low-profile heat recovery unit designed for installation within a roof space. These ERV units utilize the Xchange plate heat exchanger to recover the energy from the exhaust air into the incoming fresh air, resulting in significant energy savings. Both enthalpy and sensible heat exchange media are available. The option of EC Plug Fans makes this our star achiever in energy savings and controllability. Ceiling Mount Fan Coil Unit XCC 300 1200 The XCC series is a low-profile energy recovery ventilator with the addition of an add-on-coil. Designed for installation in a roof space, these ERV units utilize the Xchange plate heat exchanger with either enthalpy or sensible media. DX coils are designed to match with standard commercially available condensers. Hot water and chilled water coils can also be used. EC Plug Fans and in-built panel filters are standard making this solution a very flexible way to incorporate heat recovery into a ceiling mounted fan coil. PROJECT APPLICATIONS Commercial Offices, Child care and Education Apartment Bathroom Exhaust Residential Damp and Mould Control Public Occupancy Buildings Professional Suites 8 ARMCOR COMPANY PROFILE

2018 CEILING MOUNTED UNITS 9

INDIRECT EVAPORATIVE COOLING INDEC Fresh Air Cooling INDEC 1000 6000 INDEC Indirect Evaporative Cooling unit provides cool and fresh air in the hottest of climates, with radically reduced energy costs. The new generation INDEC uses a patented indirect polymer heat transfer core that delivers cool, 100% fresh outside air with very low energy consumption. Incoming fresh air passes through the primary heat exchange core which has a series of wet and dry channels allowing natural evaporation to cool the air. Warm moist air is expelled, while cool air, without added moisture is delivered into the building. Through this evaporation process the outlet air temperature becomes lower than the web bulb temperature of the ambient air. A secondary direct evaporative pad further reduces the outlet air temperature to as low as 15 C. Where should Indirect Evaporative Cooling be installed? Indirect Evaporative Cooling can be used in most Australian conditions. Typically the performance of INDEC unit excels in hot, dry ambient conditions ideally where the relative humidity is less than 50%. VERY HOT, HUMID WARM, HUMID VERY HOT HOT, DRY TEMPERATE COOL, TEMPERATE PROJECT APPLICATIONS Data Centres Fast Food and Kitchen Exhaust Factory Areas and Generator Rooms Commercial Venues, Sporting Complexes and Gymnasiums Mining Public Utility Buildings, Police, Ambulance and Nursing Homes Education Facilities 10 ARMCOR COMPANY PROFILE

Right: Next DC Data Centre. 2018 INDIRECT EVAPORATIVE COOLING 11

DEHUMIDIFICATION Dehumidification Package Unit DHP 500 6000 The DHP series are packaged dehumidification units designed to provide an economical and practical solution for humidity control. Reduction in moisture content is achieved by a combination of a plate heat exchanger and a packaged air conditioning system. The solution is achieved through a 3-stage process where the air is cooled and dehumidified through the sensible heat exchanger; further cooled and dehumidified through the cooling coil; then passing back through the opposite air flow path of the sensible heat exchange media to be reheated to the required supply air set point temperature. The standard equipment configuration includes EC plug fans, sensible heat exchange media, stainless steel drain tray and associated controls. The Armcor design engineering team can assist with a solution from our range of capacities of 500 6000 L/sec with up to 200kw cooling capacity. PROJECT APPLICATIONS Hot and Humid Locations Libraries, Archive Storage, Public Buildings, Surgery and Laboratories Apartment Lobby Ventilation 12 ARMCOR COMPANY PROFILE

Right: The air-conditioning design for the Paediatrics and Pathology building at the Nauru Processing Centre called for Dehumidification equipment capable of cooling the buildings with consideration to the specific climatic conditions of the Nauru Island. Below: Royal Hobart Hospital. 2018 DEHUMIDIFICATION 13

ROTARY HEAT WHEELS Rotary Wheel ERV REM 500 8000 The REM series is the ultimate in High Efficiency Heat Recovery utilizing a rotary heat exchanger to recover the energy from the exhaust air and transfer it to the incoming fresh air. With efficiencies up to 87%, this unit configuration suits external rooftop or plant room applications and includes energy saving EC Plug Fans, in-built bag filters and an option of enthalpy or sensible rotary heat wheels. With the low resistance through the media, economy bypass is affected through stopping the rotary heat wheel. PROJECT APPLICATIONS & OPTIONS APPLICATIONS INCLUDE Commercial Venues, Sporting Complexes and Gymnasiums Public Utility Buildings, Police, Ambulance, Nursing Homes Education Facilities OPTIONS Enthalpy or Sensible Media Economy Cycle Various control options 14 ARMCOR COMPANY PROFILE

Above: Event Hospitality used Armcor Packaged EVR Unit for the Altura Airport Hotel, Adelaide. Right: Rotary heat recovery provides Ballarat Base Hospital with efficiency in operation. 2018 ROTARY HEAT WHEELS 15

AIR HANDLING UNITS AHU 500 25,000 Air handling units (AHU) are used to condition and circulate air as part of a heating, ventilating and air-conditioning (HVAC) system. The air entering an AHU passes through air filters and across the heating/cooling coil. Then the supply air fan, provides the correct volume and pressure of conditioned air to the ductwork system. AHUs can incorporate a hot water coil, a chilled water coil, a DX coil refrigerant coil or a combination of these. Condensate drains are provided with the AHUs to capture the condensation formed through the cooling process. Specific controls are needed for AHUs and these are often integrated with Building Management Systems (BMS). The Armcor AHU design suits rooftop or plant room applications and are fully factory assembled and internally wired, and fitted with large access doors allowing for service, cleaning and maintenance. OPTIONS INCLUDE Hot water, Chilled water or DX coils Air filters Economy cycle dampers 16 ARMCOR COMPANY PROFILE

Top: High indoor air quality was required for the Plaza Premium Lounge at Melbourne Airport. Left: Australia 108. 2018 AIR HANDLING UNITS 17

CUSTOMISED OPTIONS Electrical Controls Armcor can tailor controls to suit specific projects requirements. The standard low-level control system provides easy connection to a BMS or stand-alone controller. 24-volt relays with LED lights are provided for fans and compressors. Features including fan fault output, fan status, compressor fault, motor circuit breakers, fire shown down, adjustable time delays and phase failure can all be incorporated into the electrical controls. Economy Cycles Economy cycle operation is designed to take advantage of favorable ambient air conditions to enhance equipment performance and provide additional efficiencies. Economy cycle operation is sometimes referred to as free cooling. Armcor economy cycle systems use 4 opposed blade dampers controlled by modulating motors which open/close upon demand from ambient temperature sensor. In a typical summer operation, if the ambient temperature is less than the indoor set point, dampers will open to allow fresh air to bypass and enter directly into the supply air ductwork. 18 ARMCOR COMPANY PROFILE

Heat Recovery Media Armcor has a variety of media for every situation allowing the customer to get the right product for the right application. ENTHALPY MEDIA Transfers both latent and sensible heat for the optimum energy recovery performance. SENSIBLE MEDIA Partially for use when toilet exhaust air extraction or when air stream must be totally isolated. POLYPROPYLENE MEDIA For use in corrosive atmosphere and swimming pool applications. Custom Sizing Armcor can modify standard designs to suit specific plantroom configurations to match/ replace existing equipment. Modifications such as top, bottom or side inlet and outlet openings; additional capacities or specified refrigeration are all part of the Armcor Solution capacity. HEAT RECOVERY MEDIA 19

THE LEADERS IN AIR TO AIR HEAT RECOVERY. ARMCOR.COM.AU HEAD OFFICE Armcor Air Solutions 109 111 Northcorp Blvd Broadmeadows Vic 3047 T +61 (03) 8301 9200 E sales@armcor.com.au DISTRIBUTORS North Queensland Northern Air 49 Northern Link Circuit, Shaw QLD 4818 T 07 4774 3506 E sales@northernair.com.au northernairconditioning.com.au Western Australia Turner Engineering 102 Discovery Drive, Bibra Lake WA 6163 T 08 9236 3800 E info@tewa.com.au turnerengineering.com.au Northern NSW McIntosh Airconditioning 10 Broadmeadow Road, Broadmeadow NSW 2292 T 02 4962 1155 E sales@mcintoshair.com.au mcintoshair.com.au Tasmania HVAC Supplies 6/14 Broadland Drive, Newstead TAS 7250 T 03 6331 4209 E info@hvac-supplies.net hvacsupplies.com.au