High Performance Hose High Performance Hose

Similar documents
AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

OPERATION MANUAL. LED Coupling OM-TR355E. Please read this operation manual carefully and file for future reference.

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

Chapter 5 Checks and Maintenance

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3B54VA MXZ-4B71VA. English

Specification Document. Color-changing Recovery Type Water Leakage Sensor AD-RS

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

Audi-Larm Audible Alarm

HEATING AND AIR CONDITIONING

CEILING FAN OWNER'S MANUAL

HEATING AND AIR CONDITIONING

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

TC100N. Fixed Gas Detector Operation Manual

Replacing a Gun Thermostat

INSTRUCTION- AND MAINTENANCE MANUAL FOR ELECTROMAGNETIC AIR PUMP JDK-60, JDK-80, JDK-100, JDK-120

UV Lamp and Quartz Sleeve Replacement/Maintenance

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

Air Conditioner. user installation & manual manual. imagine the possibilities

Split-type Air-Conditioner

Dyna-Star HP or HF Pump 35# Pail Kit and Follower Plate

c=) MODEL: NSD10037 PACKING DIAGRAM UMP AND (3) SHIMS ' IGHTS AND TRANSFORMER. LOWER COLUMN ESERVOIR BASE CASTING POLYFOA

DEHUMIDIFIER. User Manual 50BT, 70BT

Installation and Operation Manual. CMA12SB-0 Series. Horizontal/Side Discharge Condensing Units

CEILING FAN OWNER'S MANUAL

ESD Safe UL Approved INSTRUCTIONAL MANUAL EX V EX V TEMPERATURE CONTROLLED SOLDERING STATION

Filter for Drain and Dust (Filtering Accuracy: 5µm) Optional Selection of Direct Mount Pressure Gauge (Compact size).

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO )

No.THD51E To prevent accidents arising from the use of this product, please ensure the operator using it receives this manual.

SimplyClear Pressurized Filter Product Manual

Instructions. Certifications Brass w/built-in Stop Valve. Pressure Balance Shower Valve. Tools Required. Important Points.

Spare parts list ( ) Spare parts list Priza

Dyna-Star HP, HF, 10:1 Pumps: 120# and 400# Drum Cover and Follower Plate

13-1. Temperature Regulator

952SX-230. LONER Temperature Controlled Soldering Station

Installation & Maintenance Manual

DEHUMIDIFIER OWNER S MANUAL. Read this manual carefully before operating the appliance and retain it for future reference.

Technology for Vacuum Systems. Instructions for use

Daily maintenance and checks

F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual

DAIKIN AIR CONDITIONER

EL400 OPERATION MANUAL

READ AND SAVE THESE INSTRUCTIONS

BASIC SYSTEM LOCATION INDEX

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

Model: Series. PumpAgents.com - buy pumps and parts online. DESIGNER STYLED MARINE TOILET With Integral Bowl Rinse Water/Waste Evacuation Pump

I-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

DISTRIBUTION > HOUSING, HVAC > INSTALLATION > AIR INLET HOUSING

Table of Contents. English

951SX-230 LONER Temperature Controlled Soldering Station

Installation and Care Instructions

Reducing Valve Direct Mount Type with Pressure Gauge. Direct Mount Type (Compact size) Pressure Gauge is selectable.

RAS-10JKVP-E RAS-10JAVP-E RAS-13JKVP-E RAS-13JAVP-E

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

MODEL: NSD10020 PACKING DIAGRAM \ _\ CARDBOARD (2) CORD COVERS AND PART--+- i----1 :ASTING POLYFOAM UMP. c=j-transformer AND L_J LIGHT

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Bench-Top Vacuum Oven with 28 segments programmable controller

Two Tier Illumifalls Patio Pond

DAGNY LK. Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 110V~60Hz

OPERATION MANUAL.

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

LC Series - Light Commercial Pump Station Installation and Operation Manual

INSTRUCTION MANUAL EPH-121 CONTENTS

Desoldering Tool. Instruction Manual

Spare parts list ( ) Spare parts list PUZZI 100 *USA

5HP CYCLONE DUST COLLECTOR MANUAL

[FLARE CONNECTION TYPE] ATTENTION

WARNING. Flexible Hose AH2 With AB6 With AB6. AH2-CC With AB6 With AB6

Trooper Portable Carpet Extractor. Operator and Parts Manual. Model No.: Can Rev. 00 (09-99)

NMR SAMPLING ACCESSORIES CLEANING NMR SAMPLE TUBES

Spare parts list ( ) Spare parts list PUZZI 100

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

CONTENTS CONTROLS 3-STAGE AIR PURIFICATION. X This product is suitable for 120V only. User Manual. Odor sensor. ➌ PlasmaWave

Split-type Air-Conditioner

Installation Guide BUILT-IN SXS REFRIGERATOR UPSXB2627**

55-Gallon Dispenser Package

Pocket Hardmount. Preventative Maintenance.

SUPRA 44 WITH LIGHT KIT BY INSTRUCTION MANUAL WARRANTY CERTIFICATE

2HP MOBILE CYCLONE DUST COLLECTOR MANUAL

SUNSEEKER BY INSTRUCTION MANUAL WARRANTY CERTIFICATE

MNEFDD54 & MNBCDD54 GALVANIZED WALL FANS Installation, Operation, and Maintenance Instructions

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

Vacuum Pump V-100 Technical data sheet

7165 Dust Collector Owner s Manual

Model: AC-108. Instruction Manual

Specification Document. Heat-resisting Type Water Leakage Sensor FR-AD

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

SAN RAPHAEL PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET

Page 1 of 18. Part# /5/2013

AQVA ULTRA Faucet Purifier AQ003-1 User s Guide

USE and MAINTENANCE INSTRUCTION MANUAL GRAVITY. WS-400 EVO LS-400 Entech. SPRAY GUN Series. en it fr es pt de se

MC-UG Vacuum Cleaner. Specifications are subject to change without notice for further improvement. Order Number MAC CE

SPARE PARTS AND CONSUMABLES CATALOG US SECOND QUARTER 2015 BLUEWATER PRO WATER PURIFIER

G45 FastTrack. Page 1 of 8

Installation Instructions

Table of Contents. Notice: Any maintenance should be returned to the dealer or factory! Attention: Please read this instruction carefully before use.

Operation and Maintenance Manual BLIZZARD50 CS6-50-VD 120V/60HZ

Transcription:

Warning Counterfeit goods that violate our rights will be severely punished under the law. Our products have been either registered / applied for the ownership of patent, design, utility model and trademark in Japan, China and Asia. For inquiries : world@toyox.co.jp High Performance Hose Customer Service Centre ISO 14001/ISO 9001 certified High Performance Hose

Reuse Reuse Dimension ( mm ) Weight Package unit Piece Screw spec Dimension ( mm ) Weight Package unit Piece Spare inner fitting Spare rubber caps for TCP Package Dimension ( mm ) Weight Replacement Screw unit TCSB sleeve set spec Piece Screw spec Spare rubber caps Warning Twisted Warning

Connectors designed especially for the use of TOYOSILICONE Hoses and TOYOSILICONE-S Hoses Fits perfectly. Reuse Figure 1 Figure 2 Figure 3 Reuse Names of parts ( materials ) Nut ( SUS304 ) PVDF screw ( PVDF ) Sleeve ( PTFE ) Retaining ring Nipple ( SUS316L ) ( SUS304 ) Notice TOYOCONNECTOR-F Warning... Potentially hazardous situation which could result in death or serious injury. Notes for installation When cutting the hose, make sure that the end of the hose is perpendicular. Make certain that the hose has been fully inserted into the connector. Warning:Tighten the nut fully so there will be no gap in between in order to prevent the hose from being pulled out, and fluids being leaked. If TOYOCONNECTOR-F are used with a gap in between, trouble will occur due to hoses being pulled out. Do not damage the surface of nipples with blades and other items. After installing TOYOCONNECOTR-F, confirm that fluids do not leak from the connectors before use. For fastening, use a motor wench. Do not use a pipe wrench because it will damage the components. Notes for use TOYOCONNECTOR-F are designed especially for use of our TOYOSILICONE Hose and TOYOSILICONE-S Hose. Do not use TOYOCONNECTOR-F with other TOYOX Hoses, or other companies' hoses. No guarantee will be provided for TOYOCONNECTOR-F that are connected with other companies' hoses because the performance of such TOYOCONNECTOR-F may not be fully performed or maintained. Use TOYOCONNECTOR-F within their working temperature and working pressure ranges. Do not use TOYOSILICONE Hoses under negative pressure. For use under negative pressure, please use TOYOSILICONE-S Hoses. TOYOCONNECTOR-F may not be applicable for use under a negative pressure depending on the use and conditions ( such as temperature and movement ). Take caution when using for electric discharge/plasma, evaporation because additives may be discharged from our hoses.refer to the "Vacuum Pressure Reference Range" for a guide of the negative pressure working range. ( P31 Fig. 1 ) When inserting TOYOCONNECTOR-F into hoses, never put grease on the surface of the nipples. It would be a cause of hose being pulled out. When using TOYOCONNETOR-F, do not bend hoses sharply near the connectors because the inner tube may rupture. Warning:Do not assemble or disassemble the connector while fluid is in the hose because the hose may become loose and the liquid will leak. When using TOYOCONNECTOR-F for drinking water or food, place the hoses and the connectors so that they will not submerge in drinking water or food fluids in the tanks because the fluids may stay inside the connectors, and bacteria may propagate ( attach to the parts ). Warning:Never use TOYOCONNECTOR-F for the below applications. Hoses may rupture or become loose. For piping such as electromagnetic valve piping, which would put impact pressure on the piping. Where vibration or impact will be applied to the connector Where the maximum temperature may exceed 140 C Where constant tensile stress may be applied to the hoses In a way that may cause static buildup Before using TOYOCONNECTOR-F, make certain to sterilize and disinfect inside the hoses. ( The hoses do not go through sterilization procedures before shipping. ) When cleaning TOYOCONNECTOR-F, do not rub their surfaces with a hard brush or other things because doing so may damage the surfaces, and bacteria may propagate ( attach to the parts ). Notes for storage Please store TOYOCONNECTOR-F at low temperature and humidity. Make certain that foreign matter will not get into the connectors when stored. Notes for the replacement of hoses and connectors Make certain to use new TOYOSILICONE Hoses or TOYOSILICONE-S Hoses. Adjust the length of hoses so the hoses will not be pulled too tightly. When replacing hoses, do not damage nipples with a cutter or other items because doing so will be a cause of fluid leakage. When sleeves or PVDF screws are cracked, broken, deformed, or discolored, replace them immediately with new ones. Otherwise their performance may be impaired, e.g. they may not be able to withstand their working pressure. Notes for disposal To dispose of the metal parts of the connector, please follow local regulations for separate disposal. The resin parts ( sleeves and PVDF screws ) of the connector will emit toxic gas when burned, so never burn the resin parts, and handle them as industrial waste.

( pcs ) ( pcs ) ( pcs ) ( pcs ) ( pcs ) Conducting sleeves Fluoroplastic ( ETFE ) Repellence angle Droplet ( pure water ) PU Barbed section ( large ) Barbed section ( small ) ( pcs )