CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

Similar documents
CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

Clark County Department of Building & Fire Prevention 4701 West Russell Road, Las Vegas, NV (702) FAX (702)

HIGH-RISE RETROFIT ORDINANCES - NO and NO

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST

Fire Protection Coffee Break Training May 2016

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

TRI-LAKES MONUMENT FIRE PROTECTION DISTRICT

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

GENERAL AREAS OF INSPECTION

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC

AUTOMATIC FIRE SPRINKLER SYSTEMS

Osceola County Department of Fire Rescue and Emergency Medical Services

PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau. Permit fees shall be assessed in accordance with the Permit Fee Schedule

Fire Prevention Coffee Break Training. February 2017

Valuation: # of Plans Submitted: # of pages: Type of Work (select one): New Addition Existing System/Modification Project Name: Scope of Work:

PLAN REVIEW SUBMITTAL GUIDE

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE ALARM SYSTEM INSTALLATION

New Construction Fire Inspection Process

CHINO VALLEY INDEPENDENT FIRE DISTRICT FIRE PROTECTION STANDARD

FIRE & LIFE SAFTEY STANDARD

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

SECTION 907 FIRE ALARM AND DETECTION SYSTEMS

TABLE OF CONTENTS ADOPTED FIRE CODES... 3 AFPD SERVICE AREA... 3 SITE AND DEVELOPMENT SUBMITTAL REQUIREMENTS... 4 PLAN REVIEW FEES...

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

Fire Sprinkler Plan Submittal Form

FIRE SERVICE FEATURES

Bold items are particular to the City of Euless

September 30, Dear Fire Suppression System Contractor/Designer:

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements

FIRE SPRINKLER SYSTEMS POLICY

STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT

Fire Permit Application

El Reno Fire Department Fire Alarm Plan Review Worksheet

FIRE SPRINKLER SYSTEMS POLICY

Rocky Mountain Fire Protection District 4390 Eldorado Springs Drive Boulder, CO

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE

Fire Alarm, Water Flow Alarm & Signaling Systems

D. The work addressed in this section consists of a fire protection system, which may include coordination with one or more of the following:

Requirements for the protection of High-Piled Combustible Storage (HPCS) Effective Date: January 2011

Burnsville Fire Department 100 Civic Center Pky, Burnsville, MN Fire Marshal: FAX:

Commercial Remodel/ Add On Rules and Regulations

CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS

Full Service Central Station Fire Alarm Listing Evaluation

APPENDIX H (DESIGN SUBMISSION CRITERIA)

May 1, Dear Fire Suppression System Contractor/Designer:

System Test Report CLEAN AGENT

2012 B.C. Building Code Compliance Review (Division B Part 3)

Narrative Reports As Regulated by 780 CMR, Section 903.0

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

Health Chapter ALABAMA STATE BOARD OF HEALTH ALABAMA DEPARTMENT OF PUBLIC HEALTH ADMINISTRATIVE CODE

Residential-based Care Facility R-4 Guideline

YORK COUNTY DEPARTMENT OF FIRE SAFETY BUILDING PLAN REVIEW REQUIREMENTS

Module. Fire Protection & Life Safety. Revised: January 2013

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

Unified Fire Authority - Fire Prevention Bureau

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

Winnipeg Fire Department Fire Prevention Branch

Brighton Area Fire Authority

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

Florida Building Code 2010

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

WEST VIRGINIA UNIVERSITY

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

WHITE PLAINS SMOKE CONTROL CODE PART 1. GENERAL REQUIREMENTS

ICC CODE CORNER 2015 International Fire Code

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services 575 E. Flamingo Road, Ls Vegas, NV (702) FAX (702)

2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010)

Carrollton Fire Rescue

Plan Submittal Checklist

4/13/2015. Everything a firefighter wants to tell a design professional or building code official, in one hour.

AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations)

CITY OF PASADENA FIRE DEPARTMENT

PART II: New Construction Inspections and Acceptance Testing Procedures

California Fire Code (CFC) Part III contains requirements. Building and Equipment Design Features PART. Chapters 5 through 19

FIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

FIRE ALARM SYSTEMS INFORMATION PACKET. Des Moines Fire Department Fire Prevention Bureau

CHAPTER 7 ALTERATIONS LEVEL

FIRE PLAN CHECK CORRECTION List for Commercial Occupancies

NFPA Changes

Agency for Health Care Administration

Smoke Detector Activation of any smoke detector shall start the alarm verification mode.

APPENDIX A International Building Code Amendments

Chapter 4: Fire Protection Systems

Commercial Rules and Regulations

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE

Transcription:

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau 575 E. Flamingo Road, Las Vegas, NV 89119 (702) 455-7316 FAX (702) 455-7347 Code Sections: 105.7.18 Control Number: A.0 Effective Date: TITLE: SCOPE: FIRE PROTECTION REPORTS Clark County Fire Department requirements for submitting Fire Protection Reports for review. The guideline covers initial submittals, resubmittals, and revisions for project Fire Protection Reports, tenant improvement Fire Protection Reports, Alternate Materials and Methods narratives, and other narrative submittals that require Clark County Fire Department review. Note: There are instances where the term Life Safety Package is used in the codes and guidelines. The term Fire Protection Report and the term Life Safety Package are, for the purposes of this guideline, interchangeable. PURPOSE: To standardize plan/permit requirements of the Fire Department in accordance with Clark County Fire Code. DEFINITIONS: Assessor s Parcel Number (APN): A unique number assigned to each property by the Clark County Assessor s office. Alternate Materials and Methods: Narratives submitted in accordance with Section 104.9 of the Clark County Fire Code. Fire Protection Report: A narrative describing the life safety features that will be provided in the construction of a project. Life Safety Package: Another term for Fire Protection Report, with equal scope as Fire Protection Report. The term Fire Protection Report is preferred. Tenant Improvement (TI): A subproject within a project that itself requires a Fire Protection Report. Generally, the tenant improvement is associated with a distinct Building Department permit number. Tenant improvement fire protection reports for projects that involve building alterations, changes in boundaries for any fire protection systems, and completion shell space requiring modification to the smoke control system, require review by the Clark County Fire Department. Page 1 of 9

PERMIT FEES: Permit fees shall be assessed in accordance with the Permit Fee Schedule as adopted in the Clark County Fire Code. For applications that are expedited, additional fees shall apply. SPECIFICATIONS AND SUBMITTAL REQUIREMENTS: An application must be completed for each submittal. A minimum of three sets of reports, each with small-scale plans as required for review, shall be submitted with the permit application. In the report, indicate the project name, address, and APN (Assessor s Parcel Number). All submittals must be legible and readable or the submittal shall be issued a correction letter for cause. All high-rise, covered mall, and atrium buildings, in addition to other complex or major facilities as determined by the fire code official, shall have a Fire Protection Report submitted and approved prior to construction, demolition, or significant work stoppage. Fire protection reports shall be prepared by an architect or professional engineer working in their area of expertise. Building/Facility Fire Protection Report Submittal Requirements Building/facility fire protection reports shall describe the building uses, construction and life safety features of the entire building. The following items are required to be discussed in a fire protection report: GENERAL DESCRIPTION: Major Use(s) and Occupancy Classification Means of treating mixed use occupancies Building height in feet Height of highest walking surface above the lowest level of CCFD response Number of stories Number of subterranean levels Locations of mezzanines Building area Number of residential units (as applicable) Gross leasable area (as applicable) All locations where the ceiling height(s) exceed 25 feet above the finished floor Locations of storage of hazardous materials, including pool chemicals, cooling water treatments, oxy/acetylene welding, LP Gas and fuels Page 2 of 9

APPLICABLE CODES: Statement of the project codes and standards of record. These will include, but not be limited to the following: Clark County Fire Code Clark County Building Code SITE ACCESS: Minimum widths of Fire Department Access Roads and turning radii Major abutting public streets and roadways Points of access from public streets and roadways Locations of all Reciprocal Easement Agreement (REA s) with adjacent properties PASSIVE FIRE PROTECTION: Note that the Fire Command Center has 2-hour rating Note that the Fire Pump Room has 2-hour rating Identify locations of Horizontal Exit Walls EGRESS: When meeting rooms and ballrooms do not have sufficient exit capacity accommodate occupant loading at a factor of 7 square feet per person, the FPR or TI FPR must state that assembly events with seating in rows of chairs (only) are not permitted in the assembly occupancy, or otherwise must address the proposed uses of such meeting rooms and ballrooms. SIGNAGE: Locations of signs including, but not limited to the following: o At each FDC; stating the zones served, required pressure and flow o Fire pump room door o Fire command center (FCC) door o Emergency generator door o Main Electrical Room with service disconnect o Stairway signage o Elevator bank signage indicating to not use the elevator in case of fire o Statement requiring coordination between floor levels, stairs, elevators, and fire alarm annunciation (consistent labeling) ACTIVE FIRE SUPPRESSION: State compliance with the adopted edition of NFPA 13 Description of the design of sprinkler systems throughout State all design densities and areas of application Describe freeze protection as applicable Clearly discuss protection for areas with ceiling exceeding 25 feet in height Page 3 of 9

Describe protection of vertical systems (i.e. trash and linen chutes) and protection with separate dedicated sprinkler risers to address CCFD concerns about multiple flow alarms from a single fire area State protection methods for commercial cooking equipment; including exhaust ducts exceeding 75 linear feet (sprinklers required when exceeding 75 feet) Describe protection for elevator hoistway and machine room protection (no sprinklers at the top of the elevator hoistway or within the elevator machine room so that shunt trip is not provided) Provide an analysis of possible commodities in storage areas, and a requirement for sprinkler demand for the possible commodities for exhibition halls Casinos require OH-2 sprinkler system with QR heads Tenant spaces adjacent to assembly areas, such as casinos and malls, require separate auxiliary control valves for tenant spaces Note the seismic category for purposes of determining clearances around sprinkler penetrations through ceilings per ASCE 7 (2005) 13.5.6 STANDPIPES: State compliance with the adopted edition of NFPA 14 Automatic standpipes required for buildings higher than 55 feet from lowest level of fire access to the highest walking level The minimum outlet pressure for automatic systems is 125 psi. Class I hose valves required within the stair enclosures at every level, within the stair enclosure and not in vestibules of high-rise buildings Class I outlets required to cover all floor area with 100 feet of hose and 30 feet of spray Class I standpipe outlets required on both sides of horizontal exits State if pressure reducing valves (PRV s) are used and locations of drain valves Note that standpipe outlets will be provided at the entrance from exit passageways and at mall entrances WATER SUPPLY: State compliance with the adopted editions of NFPA 22 and NFPA 24 Describe connections to public water system Describe the secondary water supply requirements for high-rise buildings, detail volume; minimum volume is 15,000 gallons, or 30 minutes of largest sprinkler system demand (include deluge sprinkler systems) plus 100 gpm of hose for 30 minutes Describe the location of secondary water supply tank and show the location on a small-scale drawing to be included FIRE PUMPS: State compliance with the adopted edition of NFPA 20 Provided a minimum of two fire pumps where the pumping system supplies more than one building/tower. Page 4 of 9

Describe how the roof top standpipe outlet for tall buildings is supplied with the minimum demand of 125 psi when flowing standpipes per NFPA 14. Clearly indicate when the fire pump churn pressure must exceed 350 psi and address the maximum rated working pressure of fittings and pressure loss due to hydraulic friction. State that the fire pump room has direct access from the exterior. State that emergency power for electric pumps will be provided within 10 seconds of loss of normal power. The minimum duration of backup electrical supply is eight (8) hours at 100% of motor rating. FIRE DETECTION SYSTEM: State compliance with the adopted edition of NFPA 72 State all devices that will provide input into the Fire Alarm Control Panel (FACP) Provide a matrix describing inputs and outputs controlled by the FACP FIRE ALARM SYSTEM: Indicate compliance with the adopted edition of NFPA 72 Describe locations of speakers and strobes Describe the required performance criteria of the notification system Describe the alarm zones that are initiated simultaneously State if the voice alarm system is multiple channel Describe any zoning of notification that does not comply with customary floor of incident and floors above and below incident zoning FIRE DEPARTMENT COMMUNICATIONS: State methods of fire department communications State coverage areas for fire department communications Note that radio coverage systems require 95% coverage is to all floor areas and the fire pump room, FCC, stairs, service elevator staging lobbies and other critical areas require 100% coverage. SECONDARY RESPONSE POINT Note that these are required in every building requiring a fire command center. Required near at least one main entrance; preferably in a location not immediately accessible to the general public. Provide an all-call microphone at the secondary response point Provide a fire alarm annunciator at the secondary response point FIRE COMMAND CENTER: State that the floor area of the FCC in not less than 200 square feet. Additions to existing FCC s are to be a minimum 200 square feet as approved for the existing area, plus a 0.015% ratio on new building area added to the original FCC square footage above the 200 square feet. The FCC shall have direct access to the building s exterior. Page 5 of 9

The controls, equipment and documents to be provided within the FCC shall include, but not be limited to: o Emergency voice/alarm communication unit o The fire department communication system o Fire alarm system control panel o Fire Alarm LED Annunciator o Elevator location annunciator o Elevator fire recall switch o Elevator emergency or standby power selector switch(es), where emergency or standby power is provided. o Firefighter smoke control panel o Firefighter smoke removal control panel o Control to unlock stair doors (where stair doors are normally locked) o Emergency and standby power status annunciator o Generator Manual control panels; shunt and start controls o Generator supervision panel o Shunt trip switches for all power feeds o Fire pump status annunciator panels from fire pump controller manufacturer o Direct dial telephone for CCFD use o For proprietary monitoring stations, an autodial phone to Fire Dispatch o A work table with minimum dimensions of 3 feet by 7 feet. o A white board with minimum dimensions of 3 feet by 4 feet that is capable of erasure, with a marking device and an eraser attached. o Approved Building Plans o Approved Master Egress Diagram o Smoke Control System mechanical plans and response matrix o Mechanical Quality Assurance Agency (MQAA) Final Smoke Control Report o Approved Fire Protection System Plans o Approved Fire Protection Report(s) o Manufacturers manuals for all fire and life safety systems SMOKE CONTROL/SMOKE REMOVAL: Description of method of smoke control/removal used in each zone State emergency power provisions for equipment including continuously running exhaust fans Note the source of makeup air and evaluation of air velocities Describe the design and operation of the smoke control/smoke removal graphics panel State that a single switch is provided for each zone, whether exhaust, pressurization, mop-up, removal or passive Specific color-coded indicator lights on graphics panels according to CCFD colorcoding requirements as follows: o RED: indicates positive status of function o GREEN: indicates normal status Page 6 of 9

o YELLOW: trouble/fault status o BLUE: used for ancillary function, as applicable Indicate the sequencing of lights from green, to yellow and red, to red Provide the Smoke Control/Smoke Removal input/output matrix. Describe interaction between commercial cooking extinguishing system activations and the smoke control/removal systems (i.e. do kitchen systems shut down on activation of smoke control). Also discuss whether the extinguishing system activates the smoke control system. Ensure that the activation of the kitchen suppression system does not result in shutdown of the kitchen exhaust system. State that the required weekly preprogrammed testing for smoke control systems is designed into the smoke control system(s) ELEVATORS: State initiation mechanisms for all recall functions State if a shunt trip is provided State if fire/smoke dampers are anticipated over hoist way vents If provided, hoist way dampers are to have automatic operation by elevator lobby smoke detectors. The damper status and manual controls must be provided on the smoke control graphics panel State the location of the elevator car(s) that are sized to accommodate an ambulance stretcher. State that the number of elevator cars sized to accommodate an ambulance stretcher complies with code according to the number of stories in the building. DRAWINGS: FPR drawings are to be legible and not include color-coding that will not be discernable when the drawings are scanned for CCFD archives. The 11 x 17 inch paper size format in a Z-fold configuration is preferred. The drawings are to show at least the following information for CCFD use: o Conceptual access plan from major public streets or roadways o Fire access lane (shaded or hatched) with respect to the building(s), o FCC, with direct exterior access o Fire Pump Room, with direct exterior access o Site FDC(s) o Hydrant(s) corresponding to each FDC o Hydrant spacing o Secondary Response Point(s) o Emergency Generators o Main Electric Room(s) o Hazardous materials storage locations o Fuel (for diesel engine driven fire pumps, generators etc) Page 7 of 9

Tenant Improvement/Remodel Fire Protection Report Submittal Requirements A Fire Protection Report shall be submitted when any one of the following occurs within a building that would normally require or has a previously approved Fire Protection Report. 1. The area of remodel occurs over a floor area exceeding 20,000 square feet. 2. The area of remodel is an assembly occupancy with an occupant load that exceeds 1,000 persons. 3. The area of remodel occurs within spaces dedicated to or affecting emergency personnel response areas, such as exit enclosures, elevators, elevator lobbies, fire command centers, secondary response points, fire riser rooms, and the fire pump room. 4. The remodel area requires specific engineered fire suppression and/or alarm systems that will require an alternate means of system design that is not supported by adopted NFPA codes. 5. The remodel area includes clean agent suppression systems, new or existing. 6. The remodel includes kitchen exhaust systems that are used for smoke control and thereby requiring coordination of exhaust fan functioning. 7. The remodel area contains hazardous materials storage and/or use areas. 8. The remodel area includes high-piled storage. 9. The remodel area includes delayed egress systems that require interconnection with fire protection systems. 10. The remodel area modifies an existing smoke control system. Alternate Materials and Methods Report An Alternate Materials and Methods Request shall be submitted when any of the following items are involved. 1. All instances where active fire protection features are offered as a mitigation in support of an alternative solution. 2. All requests relating to or referencing the International Fire Code or NFPA codes adopted within the Clark County Fire Code. 3. All requests that involve alternate installation requirements of any active fire protection system governed by the Clark County Fire Code, such as: automatic sprinkler systems, alternative automatic fire extinguishing systems, standpipe systems, fire alarm and detection systems, emergency alarm systems, fire department connections and smoke control graphic annunciator panels. Additionally, requests involving the modification of the following items shall be submitted to the fire code official: smoke and heat vents, fire command centers, thin combustible ceilings, hazardous materials, and alternate hardware when it may affect entry into a building by emergency responders. Page 8 of 9

Temporary Certificate of Occupancy (TCO) Fire Protection Report. When a temporary certificate of occupancy (TCO) is requested in a building that required a fire protection report prior to construction, the fire code official is authorized to require a fire protection report describing the uses to be occupied, the completed construction features, and the status of life safety systems, be submitted and approved prior to approval of the TCO request. The TCO is granted by Clark County Development Services Building Division. PERMIT REVISIONS AND RESUBMITTALS: Revisions to approved plans are required to be submitted and approved. Revisions will be assessed additional plan review fees. A copy of the previously approved plan shall accompany the revised submittal to facilitate the review. Clearly indicate all changes to the revised plans by clouding the change with a delta number to signify the date of plan change. When several changes have been made, a detailed list of changes is required. Re-submittals to address a Letter of Correction will require a full submittal. These plans require a copy of the red lined plan from the previous submittal to facilitate the review. Clearly indicate all changes by clouding the change with the delta number to signify the date of plan change. PLANS CHECK STATUS INSTRUCTIONS: The status of the review can be checked by logging on to: www.clarkcountynv.gov/depts/fire The Clark County Fire Department s Fire Prevention Bureau (FPB) may witness and accept inspection, testing and maintenance of fire and life safety systems conducted by approved individuals as required by and within the scope and authority of the Clark County Fire Code. This Guideline does not take the place of the Fire Code and does not take precedence over any Fire Code requirement or position taken by the Fire Chief. When a conflict exists between the requirements of this Guideline and the Fire Code or the opinion of the Fire Chief, the Fire Code or opinion of the Fire Chief prevails. Technical Assistance may be required and when it is it will require a Technical Opinion and Report prepared by a State of Nevada licensed: qualified engineer, specialist, laboratory, or fire safety specialty organization acceptable to the Fire Chief and the owner. The Fire Chief is authorized to require design submittals to bear the Wet Stamp and Signature of a professional engineer. Acceptance of Alternative Materials and Methods requires a Technical Opinion and Report prepared by a State of Nevada licensed: qualified engineer, specialist, laboratory, or fire safety specialty organization acceptable to the Fire Chief and the owner. The Fire Chief is authorized to require design submittals to bear the Wet Stamp and Signature of a professional engineer. Page 9 of 9