False Ceiling HF Sensors

Similar documents
Tri-level Control HF Sensor

Tri-level Control HF Sensor

Built-in HF Sensor for High Bay

Tri-level Control Sensor

Tri-level Control HF Sensor

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

Premium Version Tri-level Dimming Control

IP65 High Bay Dual Sense Sensor

Daylight harvest function to regulate light output for maintaining required lux level

Loop out. Ambient daylight threshold

IP65 High Bay Dual Sense Sensor

North America Version / Dimming Function. Introduction

Integrated SensorDIM LED Driver Daylight Monitoring Version

HF Motion Sensor Introduction

FSTR- Series Microwave Motion Sensor (MSSD) Dimming Function/Detachable Version for LED Tri-proof Light & LED Batten. Introduction

MSSD- microwave sensor, Factory Set standard 3 minute delay 50% step dimming. (additional options 20% / 50%, delay from 1 to 20 minutes)

The two type sensors are innovative and active motion dimmable LED drivers or ballasts.

Introduction. Dimming Function MC003V (Standard Version) MC003V R (Reinforced Version)

LED HIGH BAY LINEAR ECO SERIES

Microwave Sensor. Basic Microwave Sensor. Energy Saving Motion Sensor. Introduction Features Technical Specification. 3 Dimensions

BIANCO SENSOR FLUSH MOUNT 15W MODEL # GBCL400HFSR

Lighting Control. Sensor Daylight 2. Daylight+Motion 3. Daylight+Motion+Control 4. Daylight+Motion+Control IP67 5

HIGH POWER LED RETROFIT MODULE

HIGH LUMINOUS EFFICIENCY

Programmable multi-functional energy saving lighting control. Easy to install and commission

LED High Bay. 150W LED High Bay GLC-ANHB-150W-1. PERFORMANCE LED Chip Lumen Output (IES) Power Consumption Efficacy (IES) Beam Angle

11,1 30. Ordering data

Data sheet. Function description. Benefits

0118M Series. Vision For Future LED SURFACE MOUNTED PANEL LIGHT WITH SENSOR OPTION. High light efficiency Energy saving Long life

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

Product Specifications

, ,

Product Specifications

DHL-LP-LED Low Profile LED Linear High/Low Bay

LPCMPIRM65 & LPCMPIRDSI65

Maxim3 TM Series IP66. LED Vapor Tight - Waterproof Key Features

Sensors Explained AUTOMATION

LPC3BSP65 & LPC3BDP65

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

User Manual 120/240/300 Outdoor Motion Detector

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

PIR movement and presence detectors 10 A

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

KingShield. - Occupancy Detectors NEW. For complete Lighting Control... ORION RANGE. P High performance for optimum switching of all types

LIVMODERN LIVMODERN RPT. Elegant linear LED fixture PART NUMBER BUILDER 10VDIM 0-10VDIMMABLE 3000K 4000K 24IN 36IN 48IN 1800LM* 3000LM** 3500LM***

Emergency Lighting Control Gear Combo Economy Version (2 in 1)

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-SS.

Integrated PIR detectors

PIR OnOff Page 2-3 PIR & Radar MinMaxOff Page 3-8. Sensor Manual LedgeCircle

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

LED T8 Tube Standard T8 LED TUBE (L05G-H)

The Power To Supply... All Your Electrical Products

XEON. High impact resistant body and PC cover. Double layer coating. through wiring. Build-in microwave sensor.

DALI MSensor 02 Multi-sensor for DALI system

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

600 Watt Dimmer Install Guide

µdim Microwave Sensors User Manual

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Analogue Dimming Microwave Presence/Absence Detector

MWS3 Ceiling Mount Microwave Occupancy Detector

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1

MWS6-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

luxcontrol lighting control system SWITCH sensors smartswitch HF 5DP f Automatic switching based on motion and light level

Direct Dim Microwave Presence/Absence Detector

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Light Control guide for Soundlight Comfort Ceiling OccuSwitch DALI Control Guide

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

SENSA MRE DDM MR

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

SWITCHLITE MRE DDM ADJ

F series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC

Devices for Special Applications

An-10 Wireless lighting control technology

An-10 Wireless lighting control technology

1. Basic safety information 3 2. Proper use 3

Movement-based energy control

MWS3A-PRM Product Guide

The Power To Supply... All Your Electrical Products

Detector switch - Dual Tech

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

Secure connection system

F series. echoflex. Slim Line Dimming Controller. Product Overview ER1S-FC

2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) LTG-1-A

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications

LEDHB LINEAR HIGH-BAY LED LUMINAIRE PART NUMBER BUILDER 140L** 200L** 170L*** 230L*** 300L*** 400L*** 840* IN 48IN

EBMHS (standard & slim-line PSU)

Eco-sensors - PIR. Catalogue number(s): / / Use. 1. Use Technical characteristics (continued)

DALI MSensor 02 Multi-sensor for DALI system

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

Transcription:

False Ceiling HF Sensors HC009S/EXT HC018V/EXT HC019V/EXT Applications Ideally suited to retrofit projects where the luminaire is too small to accomodate the sensor internally, this motion sensor can be completely hidden from view thanks to the penetration properties of microwave sensors. Only a small hole is required to position the daylight sensor. Concrete ceiling False ceiling False ceiling sensor Total 4 sensors are provided for different applications: HC009S/EXT: on/off control version HC018V/EXT: tri-level control version HC019V/EXT: synchronised control version 150 53.5 30.5 Features Zero crossing detection circuit reduces in-rush current and prolongs relay life oop-in and loop-out terminal for efficient installation Synchronised control with multiple sensor circuits (HC009S/EXT, HC019V/EXT) Tri-level dimming control based upon occupancy (HC018V/EXT, HC019V/EXT) dimming control method (HC018V/EXT, HC019V/EXT) 5 Year, 50,000hr Warranty Technical Data Input Characteristics Sensor Data Model o. HC009S/EXT Model o. Mains voltage 220240VAC 50/60Hz Sensor principle High Frequency (microwave) Stand-by power <0.5W Operation frequency 5.8GHz +/- 75MHz Switched power: Transmission power <0.2mW Capacitive 400W Detection range Max. ( O x H) 12m x 3m Resistive 1200W Detection angle 30 O ~ 150 O Model o. HC018V/EXT HC019V/EXT Mains voltage 220240VAC 50/60Hz Stand-by power Switched power <1W 800W(capacitive) 2000W(resistive) RED IP20 Environment Operation temperature Case temperature (Max.) IP rating Warming-up Ta: -20 O C ~ +60 O C Tc: +80 O C IP20 20s 165 Hytronik Microwave motion sensor

Detection area Hold-time HC009S /EXT Photocell (black) Photocell (red) Functions and Features (HC009S/EXT) 1 On/off Control This sensor is a motion switch, which turns on the light upon detection of motion, and turns off after a pre-selected hold-time when there is no movement. A daylight sensor is also built in to prevent the light from switching on when there is sufficient natural light. With sufficient natural light, the light does not switch on when presence is detected. With insufficient natural light, the sensor switches on the light automatically when presence is detected. The sensor switches off the light automatically after the hold-time when there is no motion detected. 2 Synchronisation Control In many cases, several sensors are connected together to control the same fixture, or to trigger each other, the sudden on/off of the lamp tube or the ballast/driver causes huge magnetic pulse, which may mis-trigger the sensor. This sensor has a very advanced software to ignore that interference. By connecting terminal with on another sensor, if any of the master fixture (containing sensor) is triggered, all luminaries (including s and other master unit in the group) will also light up. 3 Zero-cross Relay Operation zero-cross point Designed in the software, sensor switches on/off the load right at the zero-cross point, to ensure that the in-rush current is minimised, enabling the maximum lifetime of the relay. Alternating current 4 oop-in and oop-out Terminal Double terminal makes it easy for wire loop-in and loop-out, and saves the cost of terminal block and assembly time. Hytronik Microwave motion sensor 166

Wiring Diagram Black Red Black Red Control gear Control gear DIP Switch Settings (HC009S/EXT) 1 Detection Range Sensor sensitivity can be adjusted by selecting the combination on the DIP switches to fit precisely for each specific application. 1 2 3 100% 75% 50% 25% 10% I 100% II 75% III 50% IV 25% V 10% 2 Hold Time Select the DIP switch configuration for the light on-time after presence detection. This function is disabled when natural light is sufficient. 4 5 6 7 I 5s II 30s III 1min IV 5min V 15min VI 30min 3 Daylight Threshold Set the level according to the fixture and environment. The light will not turn on if ambient lux level exceeds the daylight threshold preset. Please note that the ambient lux level refers to internal light reaching the sensor. Disabling the daylight sensor will put the sensor into occupancy detection only mode. 8 9 10 1112 2ux 5ux 10ux 30ux 50ux Disable I 2ux II 5 ux III 10 ux IV 30 ux V 50 ux VI Disabled Detection area Hold-time Stand-by period Stand-by dimming level HC018V /EXT Push + Photocell (black) Photocell (red) 167 Hytronik Microwave motion sensor

Functions and Features (HC018V/EXT) 1 Tri-level Control (Corridor Function) Hytronik builds this function inside the motion sensor to achieve tri-level control, for some areas which require a light change notice before switch-off. The sensor offers 3 levels of light: 100%-->dimmed light -->off; and 2 periods of selectable waiting time: motion hold-time and stand-by period; Selectable daylight threshold and freedom of detection area. With sufficient natural light, the light does not switch on when presence is detected. With insufficient natural light, the sensor switches on the light automatically when presence is detected. After hold-time, the light dims to stand-by level or switch off if the stand-by period is pre-set to 0s. ight switches off automatically after the stand-by period elapses. 2 Zero-cross Relay Operation zero-cross point Designed in the software, sensor switches on/off the load right at the zero-cross point, to ensure that the in-rush current is minimised, enabling the maximum lifetime of the relay. Alternating current 3 oop-in and oop-out Terminal Double terminal makes it easy for wire loop-in and loop-out, and saves the cost of terminal block and assembly time. 4 Manual Override This sensor reserves the access of manual override function for end-user to switch on/off, or adjust the brightness by push-switch, which makes the product more user-friendly and offers more options to fit some extra-ordinary demands: * Short Push (<1s): on/off function; On Off: the light turns off immediately and cannot be triggered O by motion until the expiration of pre-set hold-time. After this period, the sensor goes back to normal sensor mode. Off On: the light turns on and goes to sensor mode, no matter if ambient ux level exceeds the daylight threshold or not. * ong Push (>1s): adjust the hold-time brightness level between10% and 100%. ote: if end-user do not want this manual override function, just leave the push terminal unconnected to any wire. 5 Semi-auto Mode (Absence Detection) It is easy to forget to switch off the light, in office, corridor, even at home. And in many other cases, people do not want to have a sensor to switch on the light automatically, for example, when people just quickly pass-by, there is no need to have the light on. The solution is to apply this absence detector : motion sensor is employed, but only activated on the maunal press of the push switch, the light keeps being O in the presence, and dims down in the absence, and eventually switches off in the long absence. This is a good combination of sensor automation and maunal override control, to have the maximum energy saving, and at the same time, to keep efficient and comfortable lighting. ote: end-user can choose either function 4 or function 5 for application. Default function is manual override. Hytronik Microwave motion sensor 168

Wiring Diagram HC018V /EXT PUSH BACK ED ED Driver DIP Switch Settings (HC018V/EXT) 1 Detection Range Sensor sensitivity can be adjusted by selecting the combination on the DIP switches to fit precisely for each specific application. 1 2 100% 75% 50% 10% I 100% II 75% III 50% IV 10% 2 Hold Time Select the dip switch configuration for the full brightness on-time after presense detection. This function is disabled when natural light is sufficient. 3 4 5 5s 30s 1min 5min 10min 20min 30min I 5s II 30s III 1min IV 5min V 10min VI 20min VII 30min 3 Daylight Threshold Set the level according to the fixture and environment. The light will not turn on if ambient lux level exceeds the daylight threshold preset. Please note that the ambient lux level refers to internal light reaching the sensor. Disabling the daylight sensor will put the sensor into occupancy detection only mode. 6 7 Disable 50ux 10ux 2ux I Disable II 50ux III 10ux IV 2ux 4 Stand-by period (corridor function) This is the time period you would like to keep at the low light output level before it is completely switched off in the long absence of people. ote: 0s means on/off control; + means the stand-by time is infinite and the fixture never switches off. 8 910 0s 10s 1min 5min 10min 30min 1H + I 0s II 10s III 1min IV 5min V 10min VI 30min VII 1H VIII + 5 Stand-by dimming level The setting is used to select the desired dimmed light level used in periods of absence for enhanced comfort and safety. 11 12 10% 20% 30% 50% I 10% II 20% III 30% IV 50% 169 Hytronik Microwave motion sensor

Detection area Hold-time Stand-by period Stand-by dimming level HC019V /EXT SYC + Photocell (black) Photocell (red) Functions and Features (HC019V/EXT) 1 Tri-level Control (Corridor Function) Hytronik builds this function inside the motion sensor to achieve tri-level control, for some areas which require a light change notice before switch-off. The sensor offers 3 levels of light: 100%-->dimmed light-->off; and 2 periods of selectable waiting time: motion hold-time and stand-by period; Selectable daylight threshold and freedom of detection area. 2 Synchronisation Function By connecting all the - and SYC terminals in parallel (see wiring diagram next page), no matter which master sensor detects motion, all luminaires in the group will turn on at the same time. With sufficient natural light, the lights does not switch on when presence detected. sensor sensor sensor With insufficient natural light, the person comes from any direction, the whole group of lights switch on. sensor sensor sensor The lights dim to stand-by level after hold-time, or turn off completely if surrounding natural light is sufficient. sensor sensor sensor The lights switch off automatically after the stand-by period. sensor sensor sensor Hytronik Microwave motion sensor 170

3 Zero-cross Relay Operation zero-cross point Designed in the software, sensor switches on/off the load right at the zero-cross point, to ensure that the in-rush current is minimised, enabling the maximum lifetime of the relay. Alternating current 4 oop-in and oop-out Terminal Double terminal makes it easy for wire loop-in and loop-out, and saves the cost of terminal block and assembly time. 1 sensor controls a group of ballast /ED driver Wiring Diagram HC019V/EXT SYC BACK ED ED Driver ED ED Driver ED ED Driver Multiple sensors control the same group of ballast /driver HC019V/EXT SYC BACK HC019V/EXT SYC BACK ED ED ED Driver ED Driver DIP Switch Settings (HC019V/EXT) Same as HC018V/EXT. 171 Hytronik Microwave motion sensor