Dave Rule, President Eric Smith, Vice President and Technical Director

Similar documents
Process Safety Management

ACKNOWLEDGEMENT. IIAR expresses its deepest appreciation to these authors for their contributions for the betterment of the industry.

Ammonia Refrigeration RAGAGEP

Supermarkets. In the U.S. supermarket industry, the fear of ammonia. Application of. Introduction. Safety

ICC CODE CORNER 2015 International Fire Code

Understanding Recognized and Generally Accepted Good Engineering Practices (RAGAGEP) for the Ammonia Industry

RAGAGEP: Codes, Standards, and Good Engineering Practice PETER THOMAS, P.E. PRESIDENT AND ENGINEER RESOURCE COMPLIANCE

Providing Solutions. Simplifying Regulation. IIAR Standards. Peter Thomas, P.E., CSP Resource Compliance, Inc.

Laboratories and Hazardous Materials. Company Overview

Ammonia Refrigeration RAGAGEP

PACKAGED REFRIGERATION EQUIPMENT

Conducting a NFPA 652 Dust Hazard Analysis (DHA): Practical Tips & Approaches

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

Fire Prevention Plan Program

YOUR BASIC REFRIGERAION SYSTEM SVASD MAY 26, 2011

Aluminum Dust Management in a Metallizing Facility

RAGAGEP UPDATE. Douglas Reindl, Director, IRC 2016 IRC R&T Forum

Safety Standard for Refrigeration Systems

Understanding. Combustible Dust Hazards: Basic Measures to Ensure the Safety of Combustible Dust Handling Operations

ASHRAE WILL GIVE YOU THE WORLD. This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee

1. PURPOSE This standard specifies safe design, construction, installation, and operation of refrigeration systems.

Ammonia Refrigeration RAGAGEP

FEASIBILITY OF AMMONIA IN U.S. SUPERMARKETS

IMC Significant Changes Summary Tier I

ICC Update - Laboratory Issues Code Changes / Proposals / Trends of Interest 10/2005

ASHRAE WILL GIVE YOU THE WORLD

Packaged Ammonia Chillers with Variable Frequency Drives powerpac

Safe Handling of Ammonia & Reporting Leaks. Andrew Keeley, Senior Project Professional

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

GASEOUS HYDROGEN SYSTEMS

Compliance Guidance for non-technical managers

STATE OF RHODE ISLAND AND PROVIDENCE PLANTATIONS

The element is closed at one end and open at the other, and it s bolted onto the explosion vent opening on the equipment so that its open end overlaps

AMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER

Safety standard developments within ASHRAE 15 and ISO UNEP workshop on safety standards, Bangkok

BSR/IIAR 5-201x IIAR 5

Ammonia Supply Systems for SCR

Chillers and Refrigerants. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc. APPA Institute Session 322 EU

Hazard Communication Self Inspection Checklist

CARBON DIOXIDE SYSTEMS FOR BEVERAGE DISPENSING PERMIT REQUIREMENTS

REFRIGERATION CHAPTER 11

Carbon monoxide (CO) is a colorless, odorless gas that is the product of incomplete combustion of carbon-based fuels.

2015 & 2012 International Mechanical Code Significant Changes and the PA Uniform Construction Code

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

PERFORMANCE METRICS FOR SAFE LASER OPERATIONS AT SLAC NATIONAL ACCELERATOR LABORATORY 1 Paper # 203

Application Bulletin. LNG / LPG Facilities FLAME AND GAS DETECTION FOR LNG FACILITIES

investment in R&D, the commitment to - name.

JAMES MOODY IM FLASH LIFE SAFETY AHJ

General Guidance. The easiest way to establish the amount of refrigerant in the system is to use data supplied by the manufacturer:

1998 Expedition/Navigator Workshop Manual

Ammonia. Background on ammonia as a refrigerant

Section 5.0: HAZARDOUS MATEIRAL STORAGE TABLE OF CONTENTS. A. Regulations, Standards and References 2. B. Scope 3. C. Approvals and Listings 3

General Safety Training

Flammable Liquid Storage

R-407A R-448A R-449A

Electrical Hazards and NFPA-70E: Protecting Your Employees

The Cannabis Industry: Fire Department Requirements

CALIFORNIA MECHANICAL CODE OVERVIEW OF 2016 UPDATES CHANGES AND RAMIFICATIONS

MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS

Preventing False Alarms in Ammonia Gas Detection Systems

Become familiar with the subject areas in the table of contents for OSHA standards through and

Climate Control System

REFRIGERATION CHAPTER 11

STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT

ALARM SYSTEMS AND EVACUATION PLANS SELF INSPECTION CHECKLIST

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Flammable Materials SC-127

ALARM SYSTEMS AND EVACUATION PLANS SELF INSPECTION CHECKLIST

INSPECTOR I SKILLS ADMINISTRATION

Fire Prevention Plan

Flammable Liquid: A liquid whose flashpoint is greaterless than 100 F when tested by closed-cup test methods.

PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE

Facility Safety Rules Hazard Communication Emergency Procedures Fire Safety. Safety Orientation

analysis ASHRAE : Implications for Mechanical Room Design

A2L Refrigerants. Objectives 14/09/2017

Alternative refrigerants or HFCs: an obvious choice? Safety first when choosing a refrigerant!

COMBUSTIBLE DUST HAZARD RECOGNITION

Today, we re going to talk about emergency action and fire prevention. We hope we never have to face an emergency situation like a fire in our

Narrative Reports As Regulated by 780 CMR, Section 903.0

TAHOE DOUGLAS FIRE PROTECTION DISTRICT JOB DESCRIPTION Fire Inspector Fire Prevention

ENERSAVE Hydrocarbon Scroll Water Cooled Chiller

Campbell Soup Company Extends Use of CO2 Systems Into Their Operations

DENVER AMENDMENT PROPOSAL 2015 INTERNATIONAL CODES

Fire Prevention Plan

Todd Jekel, Assistant Director, IRC Feb. 8, Standard Definition. What is a machinery room?

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 6

BUILDING/FIRE CODE REFERENCES 2006 EDITION

Fixed Ammonia Gas Detection. Why it's needed and what it can do for you.

Energy Use in Refrigeration Systems

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

BSR/ASHRAE Addendum b to ANSI/ASHRAE Standard FORWORD

Guide - Basic Information

Ammonia Refrigeration: What should you keep in mind?

March 10, 2016 San Joaquin Valley RETA Meeting

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

Applying the Frick Low Charge Central System to a New Freezer/Cooler Facility

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009


SEF Presents: Common Questions for a Chemical Safety Program. Wednesday September 20, 2017

Hazard Zone Locations: HAZARD ZONE CHECKLIST

Transcription:

Dave Rule, President Eric Smith, Vice President and Technical Director

Technical Society for Industrial Refrigeration ANSI Accredited Standards Writer Advocacy for Natural Refrigerants Educational Resource Work with ASHRAE, RETA, WFLO, IARW, IACSC, etc. 40 Year Anniversary

IIAR is an organization providing advocacy, education, standards and information for the benefit of the ammonia refrigeration industry worldwide

42nd Anniversary!

2,300+ Members Members in 80 countries 1,300+ members at Annual Conference and Heavy Equipment Show IIAR Membership By Category Contractor End User Manufacturer Other

An era of cooperation A focus on education (training) for everyone The IIAR and OSHA Alliance with the GCCA OSHA Institute The IIAR and EPA Green Chill Program E 3 Program SNAP approved refrigerant Designing Engineered Solutions

Process Safety and Risk Management Programs IIAR promotion as Excellent Training Tools Updated IIAR Compliance Library Meeting expectations for today s session Showing up is the first step A safer workplace and community is the objective Understanding what makes an industrial refrigeration system safe - dialogue Focus on ammonia releases prevention Flammability Toxicity

Releases keeping ammonia in the system Operator training System Design Personal Protective Equipment Compliance Codes and Regulations Releases When over pressure, maintenance activities Why Equipment failure or Human Interface Where Piping, System Components

The concept of refrigeration went unchanged for 2000+ years until mechanical refrigeration was invented 150+ years ago 9

10

Since its invention, the process of mechanical refrigeration has remained relatively unchanged 11

Refrigeration systems do not add cold they remove and relocate heat Think of a train on a circular track with two stations. Heat passengers are loaded at one station and unloaded at the other 12

4. Compressor 5. Condenser 3. Evaporator 2 Expansion Valve 1. Receiver 13

By removing heat, evaporation is a cooling process Low Pressure Gas Evaporator Low Pressure Liquid Expansion Valve Receiver High Pressure Liquid The Refrigeration Process 14

Low Pressure Gas High Pressure Gas Compressor Condenser Evaporator Low Pressure Liquid Expansion Valve Receiver High Pressure Liquid The Refrigeration Process 15

Low Side High Side Low Pressure Gas High Pressure Gas Compressor Condenser Evaporator Low Pressure Liquid Expansion Valve Receiver The Refrigeration Process High Pressure Liquid 16

Gas Low Pressure Gas High Pressure Gas Compressor Condenser Evaporator Low Pressure Liquid Expansion Valve Receiver The Refrigeration Process High Pressure Liquid Liquid 17

Receiver - A reservoir for high-pressure liquid refrigerant 19

Expansion Valve A device used to reduce refrigerant pressure and the control flow rate 20

Ammonia Recirculator Package

Evaporator Allows refrigerant to absorb heat 22

Evaporator Allows refrigerant to absorb heat Rooftop Air Unit for Cooling and Make-up Air Food Production Room Air Unit During Clean-up Operations

Evaporator Allows refrigerant to absorb heat Liquid Chiller Shell & Tube 24

Evaporator Allows refrigerant to absorb heat Liquid Chiller Plate & Frame 25

Compressor - Increases system pressure and pushes refrigerant through the circuit 26

Screw Compressor 27

28

Reciprocating (piston) Compressor 29

Condenser - allows refrigerant to reject heat 30

Liquid or gas used to absorb and reject heat Ammonia A gas that is quite easily changed to a liquid at a low temperature with a favorable latent heat of vaporization Naturally occurring and biodegradable Freon gases Manufactured Many have damaging side effects on the environment Others 31

You ll smell ammonia well below a dangerous concentration Odor threshold (ANSI K61.1) 5ppm (.0005% in air) PEL (OSHA) 50 ppm Household ammonia (1-4% aqueous solution, ½ inch from top ~200+ ppm) IDLH (NIOSH 95) 300 ppm Ammonia smelling capsule (600 ppm) Immediate throat irritation (ANSI K61.1) 400 ppm Serious eye irritation (ANSI K61.1) 700 ppm Acute toxicity 1,000 ppm Rapidly fatal 5,000 ppm A 1-pound leak yields 22.4 cubic feet of gas 22.4/0.000005 (odor threshold) yields 4,480,000 cf smelly air 32

Ammonia STINKS! Refrigeration is a complex subject A history of releases Ammonia releases don t set well with the public dangerous or not 33

Largely because of odor and noxious effects, ammonia has an image problem Freon gases were regarded as the safe refrigerants for years until environmental issues of global warming and ozone depletion took the forefront Fatality rates of ammonia and Freon are equal by law, ammonia is reported, thus adding to the image problem 34

From 860 chemicals evaluated for refrigeration in the space program, ammonia scored highest It s as natural as water simple molecule of nitrogen and hydrogen Superior physical properties Stability Relative toxicity Relative flammability Compatibility with materials, gaskets, etc. Price 35

Fatalities (average per year during the past 12 years for air conditioning and refrigeration applications only) Halocarbons ~ 2 per year Ammonia ~ 2 per year Nitrogen is used for industrial pressure testing and inerting processes with a fatality rate of 8 per year. (ref. Chemical Safety Board)

A relatively short time ago, many believed natural gas was too dangerous for widespread use They added odorant to natural gas! 37

Nevertheless, natural gas continues to have safety issues And don t forget propane 38

2% 18% Fertilizer Industrial (pollution control, waste treatment, textile manufacturing and plastics) Refrigerant 80% 39

Cooling or Heating Source Air or Substance to be Cooled or Heated A system having the evaporator or condenser in direct contact with the air or other substances to be heated or cooled 41

Cooling or Heating Source Air or Substance to be Cooled or Heated A system having a secondary coolant which passes through a closed circuit that is in direct contact with the air or other substance to be cooled or heated 42

Refrigerating systems are assigned probability ratings to indicate the degree of probability that leakage of refrigerant will enter an occupancy-classified area High probability less safe Low probability more safe 43

Cooling or Heating Source Air or Substance to be Cooled or Heated High Probability 44

Cooling or Heating Source Air or Substance to be Cooled or Heated Low Probability 45

1. The IMC permits refrigerants in any safety group to be used In low-probability systems In high-probability system equipment located within refrigeration machinery rooms 2. Use of refrigerants in high-probability systems outside of refrigeration machinery rooms is limited based on The occupancy classification of the space The safety group of the selected refrigerant The quantity of refrigerant Except for certain refrigerated storage or processing areas 46

ASHRAE 34 Safety Groups Safety Groups Higher Flammability (3) A3 B3 Increasing Flammability Lower Flammability (2) A2 (A 2L) B2 (B 2L) No Flame Propagation (1) A1 B1 Lower Higher Toxicity (A) Toxicity (B) Increasing Toxicity 47

Personal injury and property damage Release of refrigerant from a fracture, leaking seal or incorrect operation can damage property and cause injures Fire or deflagration hazard associated with escaping lubricant or refrigerant can damage property and cause injures 48

ASHRAE IIAR Standards Code Developmen t Bodies: NFPA, ICC, IAPMO State Legislatures Provide Authority State, Local Codes, Building Departments Local Fire Departments or Emergency Response Insurance Company Requirements End Users OSHA Environmental Protection Agency Department of Homeland Security

50

In the case of ammonia discharge, the fire code has traditionally had two concerns of interest Discharge of overpressure relief vents, which operate automatically if needed to maintain a limit on system pressure Manual discharge to diffusion systems, which must be operated by someone who is knowledgeable regarding system design pressures and safe operating limits 51

IFC Regulations For Refrigeration Systems Fire Codes IFC Section 606 is the primary IFC section regulating ammonia refrigeration systems Provisions in the fire code primarily focus on issues involving emergency control and alarm systems and emergency response 52

Mechanical Codes Chapter 11 of the IMC regulates the design and installation of mechanical refrigeration systems The IMC focuses on protecting occupants, the environment and the local community 53

IMC Regulations For Refrigeration Systems The IMC and ASHRAE 15 are generally coordinated 54

ASHRAE Regulations For Refrigeration Systems ASHRAE 15 ASHRAE - American Society of Heating, Refrigerating and Air Conditioning Engineers ASHRAE 15 - Safety Code for Mechanical Refrigeration, is an American National Standards Institute (ANSI) accredited standard Regulations in ASHRAE 15 are generally consistent with the IMC and IFC, but are more detailed 55

ASHRAE Regulations For Refrigeration Systems ASHRAE 15 Specifies safe design, construction, installation and operation of refrigerating systems Establishes safeguards for life, health and property and prescribes safety standards Applies to new installations and modifications of existing installations 56

IIAR Regulations For Refrigeration Systems IIAR 2 IIAR - International Institute of Ammonia Refrigeration IIAR 2, Equipment, Design and Installation of Ammonia Mechanical Refrigerating Systems, is an American National Standards Institute (ANSI) accredited standard This document is specific to ammonia systems and provides detailed design and installation information not typically referenced during inspection 57

Codes specify two levels of machinery room protection for refrigeration equipment Basic machinery room (Section 1105) Special machinery room (Section 1106) Except for small installations, such as listed, factory assembled units, ammonia refrigeration systems will require a special machinery room 59

Exterior Make-up Air Authorized Personnel Only Swing To Egress And 2-exits >1,000 sqft Emergency Ventilation ON S Refrigerant Vapor Alarm S Emergency Machinery OFF Open-flame, Fuel-burning and Hot Surface Equipment Restricted Ordinary Ventilation And Emergency Exhaust Openings sealed (rated?) Seal Penetrations 1-hour Construction Per ASHRAE (IBC waives if sprinklered) 60

Like any liquefied compressed gas, the release of liquefied ammonia to atmosphere causes the remaining liquid to cool Once the system pressure has been released and the liquid cools to its boiling point temperature, evaporation slows dramatically, and the liquid essentially sits there 61

We ll demonstrate...

System will sit at -28 F and 0 psi Initial fill After 2-hours plus manually draining 2 cups

IIAR has been successful with proposed changes to model fire codes that deal with ammonia discharge to promote design flexibility. 64

New Alternatives to Water Tanks Water diffusion tanks, pros/cons: Do you really want your last line of defense before an release from the system to be located 30 feet under water? 2003 IFC: Systems containing ammonia refrigerant shall discharge vapor to the atmosphere through an approved treatment system, a flaring system, an approved ammonia diffusion system or by other approved means. Exception When the fire code official determines, on review of an engineering analysis, that a fire, health or environmental hazard would not result from discharging ammonia directly to the atmosphere. 65

2003 International Fire Code 2003 IMC defers to ASHRAE 15, which permits atmospheric discharge 66

Automatic Emergency Pressure Control Systems are now required in lieu of emergency control boxes. Automatic hi-low crossover valve Redundant overpressure cutouts 67

High Side Pressure 300 250 200 150 100 50 Process Control Limit Compressor Cutout EPCS Cutout & Bypass Relief Vent 0 Release Prevention Steps 68

IIAR-2 is considered the benchmark for industrial refrigeration systems using ammonia However. Bulletins are used as guidance documents and industry best practice by inspectors The informative sections of IIAR Standards are also used as best practice guidance by inspectors

What is IIAR doing? Creating Standards intended for Codes Creating Handbooks intended for guidance Eliminating Bulletins Re-writing existing Standards based upon the new understanding that inspectors will use the entire document as the basis for inspections

Official Alliance created July 31, 2010 First Alliance program under the Obama Administration Committee of End Users, Contractors, Manufactures and our Government Affairs Director, Lowell Randel

The Alliance is the centerpiece of the new IIAR program to create cooperation between OSHA and the Industrial Refrigeration community Improve worker safety Increase compliance Improve communications Provide Education for OSHA Help reduce citations and fines

Desire for Engineered Solutions Employee involvement during inspections Promoting exterior piping and valve stations Resolving requirements associated with roof access, body and eye wash stations

Higher pressure rated vessels 300psig Smaller Ammonia charges (direct expansion, electric defrost, penthouse location for cold storage and process evaporators) Over pressure relief to lower pressure side (EPCS) Secondary coolants in process and storage areas CO2, Glycol, Brine

Personnel Training Emergency Responder Training Regulatory Enforcement Training Engineered Solutions are certainly a part of the solution

January Meeting Between OSHA and the SRC: Best for the industry to develop RAGAGEP or else OSHA will apply other standards Two systems, each under 10k lbs, on one property. Total over 10k. This is a case by case analysis. If a situation can reasonably affect both systems, PSM required. Repetitive SOPs for like equipment and applications good or bad? Are we ensuring that a whole system approach is being emphasized? Technical Operating Specifications: Good, but not required in SOPs must be readily available to personnel

Penthouses with air units should not be considered machinery rooms. Problems and effectiveness of machinery room provisions will not provide the protection that is assumed. Companies are encouraged to take a strong stance. Compromises can be made, such as personal wash units.

Industrial Refrigeration systems are thought to be overly inspected by comparison to other industries Systems are simplistic, easier chore for inspectors likely not to see much change in this any time soon. IIAR is encouraging the concept of OSHA looking for safety issues, but not administrative needling. Documentation is the common ground, but the real goal of safety should be at the forefront. Good players are not the problem they are the ones who realize the benefits of safety, energy efficiency, reduced costs and higher production. We don t want OSHA to alienate them.

In 1992 OSHA published its PSM Standard The IIAR published Guide to the Implementation of Process Safety Management for Ammonia Refrigeration in 1994 to provide comprehensive advice for compliance

One chapter for each of the 14 PSM elements The first part of each chapter contained the relevant text of the PSM Standard and a description of the employer s compliance obligations The second part consisted of a general series of work practices that may assist the employer in developing a PSM Program

In 1996 EPA published its Risk Management (RM) Program Rule The IIAR updated the Process Safety Management Guidelines in 1998

Included lessons learned from the first five years of PSM implementation and enforcement Added new material related to the RM Program Rule in a companion Risk Management Guidelines

Work practices have been an excellent source of relevant information Guidelines and related training have attracted end-users to the IIAR Implementation practices have changed over the last 10+ years

IIAR established a Task Force in 2010 to update the IIAR Process Safety Management Guidelines and the Risk Management Program Guidelines New Guidelines were completed in 2012

Put Guidelines in user friendly format Update the Guidelines to reflect OSHA and EPA clarifications Update the Guidelines to reflect current PSM and RM Program practices Update the Guidelines to reflect OSHA s NEP

Additional information added: How to prepare for and participate in an OSHA/EPA inspection Summary of recent OSHA/EPA citations How to respond to an OSHA/EPA citation

All OSHA and EPA interpretations are listed If Task Force agrees with the interpretation guidance includes steps to comply If Task Force disagrees with the interpretation (e.g., hydrostatic relief valves) information has been provided to address the interpretation If Task Force feels OSHA or EPA interpretation can not be enforced but agrees with their suggestions, TIPS are given to help each facility to decide what is best for their operation

Task force wrote a management system guide to help companies keep up with their program documentation. Revised guidelines have simpler format Organizational chart List of PSM and RM Program activities with space to assign responsibilities Provisions for a document plan

Increased emphasis on EPA Guidance Description of how to use engine room as a containment device Current population programs to be references Plan to be in Report Format

Guidance is provided on the changes in the regulation including use of RMP*eSubmit Guidance is provided on the difference between: Accidents which should be investigated as part of PSM/RM Program Accidents which need to be reported to the NRC Accidents to include on five-year accident history

Additional TIPS provided on how to encourage participation References to the EPA RM Program added

Several OSHA clarifications addressed Additional options provided for Estimating ammonia inventory Documenting relief system design basis

Ensure questions reflect current industry standards and guidelines Ensure all operations addressed (e.g. oil draining) Reflect OSHA citations Address facility siting, human factor and site security issues Consistent with the ARM Program

Ensure guidelines are consistent with IIAR-7 Ensure sample operating procedures are still relevant and accurate

Document updated to reflect current training options available: IIAR videos Publications Outside training resources

Updated, stream-lined forms provided Recent OSHA clarifications are addressed

Guidelines were updated to ensure they reflect current industry standards and guidelines, especially IIAR-5 and IIAR-6 References to non-applicable standards were deleted

Forms were updated Odor compliant procedures added

Procedures were streamlined Updated checklist has been provided

Additional clarification was provided on response options Guidelines have beenupdated to reflect current suggested response procedures