Unico Presentation. Introducing

Similar documents
Unico Presentation. Abridged iseries

Unico Training. Welcome to Unico!

Welcome to Unico! The Small Duct High Velocity (SDHV) System

The Benefits Really Add Up

December 2014 Pints with Pete

Training Manual UNICOSYSTEM.COM (800) Outlets are available in styles and finishes to match any décor.

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems

RCS Residential Control Systems Inc.

Troubleshooting the Indoor AHU as a Standard Product

Ductless Split Systems Concealed Duct Heat Pumps

Vertical Air Handler Unit

EnviroZone-4 & EnviroZone-2 Quick-Start Guide

Unico Training. Class for R E Michel Salesmen

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

Instructors: Contact information. Don Reynolds Doug McGee Factory Tech Support

Installation & Operation Instructions

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

OPERATION INSTRUCTIONS DEMAND DEFROST CONTROL BOARD MODEL FOR USE WITH MODELS: AFFINITY, ECHELON, ACCLIMATE HEAT PUMP SERIES

INSTALLATION INSTRUCTIONS

Ductless Split Air Conditioner

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

Installation & Operation Instructions

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

TECHNICAL NOTICE: Supplemental External Heat Control/Reduce Fan Operation Indoor Unit Firmware Version: (14/06/13) or newer

190 PINT MANUAL # Pint 86 F 80%RH 115Pint 80 F 60%RH

Safety and Installation Instructions Model 1700

SECTION VARIABLE REFRIGERANT VOLUME (VRV) HVAC SYSTEM

ATTACHMENT D #1 - HVAC (OIL) - SINGLE FAMILY DWELLINGS Category C: OIL

TECHNICAL SPECIFICATIONS

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

CAH SERIES INSTALLATION & MAINTENANCE MODELS CAH CAH

Ductless Split Air Conditioner

Advance Split

Installation, Safety & Maintenance Manual Model 1750A/1770A

Specifications and Performance

2 shp 13 lc 1 36 t - 1 a

TECHNICAL SPECIFICATIONS

-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair.

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

Lennox Mini-Split Systems Year-Round Comfort and Performance

START UP FORM PACKET

Technical Manual Binair Monobloc Heat Pump

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Condensing Unit Installation and Operating Instructions

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Your safety and the safety of others are very important.

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

TECHNICAL SPECIFICATIONS

Installation Instructions Read and become familiar with these instructions before beginning installation.

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Model 1750A/ 1770A Dehumidifier Installation Instructions

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

MINI-SPLIT STANDARD CONDITIONERS SINGLE ZONE. Available styles

Installation Instructions

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Variable Speed Convertible Air Handler 2 1/2 Ton

HYDRO-AIR ZONING CONTROLS ARH-1, ARH-2, ARH-3

Daikin ENVi Thermostat installation overview

T2CG/T2HG, T3CG/T3HG, T4CG/T4HG Multi-Zone

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil

Unit Controller (UC8) Quick Reference Operation and Fault Diagnosis

Variable Speed Convertible Air Handler 5 Ton

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

INSTALLATION & OPERATING INSTRUCTIONS FOR CEILING MOUNT AIR HANDLERS AC SERIES

READ ONLY. American Standard Ductless Systems Product Catalog. A Comfortable, Convenient Solution Built To A Higher Standard.

R21C Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort R21C. Straight Cooling Nominal Capacities

TB-200 CD-TB PRODUCT OVERVIEW. Product. Description. Specifications SKU: TB-200. Wiring. Battery Powered Thermostat

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

Condensing Unit Installation and Operating Instructions

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

R22C/H Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort

Otherwise, you can continue reading the file on the following pages.

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

TECHNICAL SPECIFICATIONS B6VMMX

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

SLIDE-IN HEATING COIL INSTALLATION MANUAL BULLETIN

HEATING & COOLING SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

Modular Multi-position Air Handler

Ductless Split Systems Ceiling Cassette Heat Pumps

SSIC INSTALLATION, OPERATION & MAINTENANCE MANUAL

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Variable Speed Convertible Air Handler 4 Ton

Indicates incorrect room temperature. No second stage or AUX heating. Emergency heat does not turn on

LRP14HP. Residential - R-410A L RP 14 HP 36 P A MODEL NUMBER IDENTIFICATION. Bulletin No November 2016 Supersedes October 2016

Service Step by Step Trouble-Shooting Check-List

Multi zone Two, Three, Four and Five Zones

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

L CONNECTION NETWORK Commercial Controls

AG Series Electric Heaters

Installation Instructions

Transcription:

Introducing

Combines all the efficiencies and performance of inverter technology with all the features and benefits of The Unico System

Made in conjunction with Argoclima Group is a European leader in HVAC technology and applications. The headquarters and the main factory of the Argoclima Group, is located in the north of Italy, near Milan.

What is iseries? An Inverter Heat Pump Can be used for Air Conditioning, Heating, and Domestic Hot Water (DHW) through use of an optional de-superheater Outdoor and Indoor units can be matched to the desired configuration + =

4 Zone Dampers in Plenum

What is iseries? SINGLE SPLIT: One Outdoor Unit and One Indoor Unit MULTISPLIT: One Outdoor Unit and up to Four Indoor Units SINGLE SPLIT One outdoor unit can be both single split and multi-split MULTISPLIT

FEATURES Unico Presentation AND BENEFITS

Features Unico Presentation that the market leaders in ductless air conditioning and heating do NOT have: Auxiliary Heat Lower Temperatures for Heating Operation Better defrost system, can heat when the system is in defrost mode Same outdoor unit can be used for both one to one and multi-split applications Both SDHV and High Wall Mount on one outdoor unit

Features that the market leaders in ductless air conditioning and heating do NOT have: Ability to do zoning with dampers A variety of third party thermostats Ability to cool or heat multiple rooms (Central Air- Conditioning vs. Room Air Conditioning)

Unico SPECIFICATIONS Presentation

Higher SEER IS30G80 with non-ducted inside units : 20.00 SEER IS36G110 with non-ducted inside units: 18.00 SEER IS30G80 with Unico and non-ducted 16.25 SEER IS36G110 with Unico and non-ducted 15.50 SEER iseries with Unico only 14.00 SEER (from AHRI directory of Variable Speed Mini Duct Heat Pumps)

OPERATION

Inverter Technology Uses 230V 1 Phase Power Converts to DC power Uses a SVPWM technology to convert DC power to 3 Phase DC Speeds up or down condensing unit and fans to meet load

SVPWM 180 Inverter Using a Pure Sine Wave. Takes care of electrical Noise in a system

Wide modulation range Larger modulation means less electric consumption and more efficiency

OPERATING LIMITS

SDHV RATINGS

New Cooling Only Guidelines We have 100% capacity at 5F outdoor temperature We have at least 65% of capacity at -15F outdoor temperature These tests involved NO wind baffles Same performance in 5 mph wind tests

UNIT SELECTION

Indoor units range IS12MPA IS24MPA U1218L-EA2TX M2430BL1-EA2 & M2430CL1-A M3036BL1-EA2 & M3036CL1-A

A

iseries and the Unico System Unico Presentation These Unico SDHV systems can be used in conjunction with the ISeries. U1218, M2430, M3036 Different Control Box and Coil Module SDHV

New Unico Units Unico Units U1218-1EA2AX M2430BL1-EA2 M2430CL1-A M3036BL1-EA2 M3036CL1-A Description FCU, 230V for iseries with Heat Pump Coil 2430 Module, Blower with iseries Inverter Control Board, EC Motor, 220V 2430 Module, Heat Pump Coil, iseries Inverter 3036 Module, Blower with iseries Inverter Control Board, EC Motor 220V 3036 Module Heat Pump Coil, iseries Inverter

* * Item 17 supplied with Outdoor Unit

MP SERIES INDOOR UNIT

Sizes IS12MPA Up to 12,000 btu s Size A IS24MPB Up to 24,000 btu s Size B

Drains Usually No Trap Mini-Condensate Pump (common)

REFRIGERANT CIRCUIT SETTINGS FOR HIGH WALL MOUNT UNITS

COMMUNICATION CHANNEL SETTINGS FOR HIGH WALL MOUNT UNITS Third and fourth settings of SW1 as shown

Wiring connection MPA Series IF USING THE WALL MOUNT UNIT THE ELECTRIAL SUPPLY COMES FROM THE OUTDOOR UNIT

Less than one amp current, no breaker

Remote Control Only way to control the High Wall Mount Unit Optional for use with SDHV (Unico) Air Handler

REFRIGERANT LINES

Refrigerant Line Circuits Refrigerant Line Circuits Labeled from 1 to 4 Hook up the first indoor unit to 1, second to 2, etc. Outdoor units have up to four circuits

Line Set Sizes For Size A : ¼ X 3/8 For Size B and Size C : ¼ X ½ For Size D : 3/8 X 5/8 Use flare nuts included with outdoor unit to attach

For One Indoor Unit Hook Up the Circuit Line Numbered 1

Two Indoor Units Refrigerant Line Connections

Unico Size Presentation M3036 Detail Suction Line Adapter Must Be Used

Unico Outdoor Presentation units IS36G110 emix LINE Circuit 3 Circuit 2 Circuit 1

Torque Wrench Yellow Jacket Model #60650

Torque Settings (US) Size Tightening Torque ¼ 15-20 ft./lb. 3/8 25-29 ft./lb. ½ 36-40 ft. lb. 5/8 45-60 Ft. LB

LINE SET LIMITATIONS

Four Line Set Lengths Total Line Set length Longest Single Line Set Height Difference Between Indoor and Outdoor Unit Height Difference Between Indoor Units

Distance limits Two type of limits are to be considered: distance limits between indoor and outdoor units (Ln) and height difference limits (Hn).

Adding Refrigerant ¼ x 3/8 Line =.16 oz. per additional foot ¼ x ½ Line =.22 oz. per additional foot 3/8 x 5/8 Line =.49 oz. per additional foot

ELECTRICAL

Electrical Power to Unico Air Handler If you are using a Unico System (SDHV), the power is supplied to the control board on the Unico Blower Module Must be 230v single phase power DO NOT POWER THROUGH OUTDOOR UNIT!

Communication Wire Must be RF shielded (A foil shield with drain wire) Ground ONE end (does not matter which end) 18/2 with shield and drain wire is very common All iseries Units will require a communication wire connection to the outside unit

Dip Switches 1 and 2

Setting the Switches

The IndoorB Board Includes two Fuses F1 and F2 F1 is 3.15A 250V (Unico P/N A01971-001) F2 is 100mA 250V (Unico P/N A01971-002)

The IndoorB Board (See installation manual) provides for: Alarm Condensate Pump Float Switch

Two Stage Heat Pump Thermostat

Components of the Thermostat Board: Terminal Block: R: 24V power C: Power, Common B: Reversing Valve (energize on heat) Y1: Stage One Heating/Cooling Y2: Stage Two Heating/Cooling

Note: Operation of fan only in heating mode can be overridden by call for heating

LED s

Components of Thermostat Adapter Board Outputs C: Common S1: Stage 1 Supplemental Heat S2: Stage 2 Supplemental Heat S3: Stage 3 Supplemental Heat AUX : 24V output (for hot water coil)

Sequence of Operation For Electric Backup: In heating mode for 20 minutes and thermostat not satisfied, S1 turns on After 20 minutes, then S2 is energized After another 20 minutes then S3 is energized

For Boiler Changeover (SDHV) Install jumper plug on the J5 (Humidity Sensor) connector

Hot Water Operation By default: Shuts off heat pump at 32F outside temperature Keeps fan running at High airflow Re-starts heat pump when temperature reaches 37F Can be adjusted

To Adjust Boiler Changeover Temperature Please refer to the earlier section on the remote control

MMI BOARD

PREPARING FOR INSTALLATION

Refrigerant circuit GAS LINE

I Series Defrost

Intelligent Defrost and Dynamic Cold Draft Unico Presentation No Cold Blow = No Cycle Losses More Efficient, You never stop heating in the Defrost Mode A trickle of hot gas directly from the compressor is used to prevent ice from forming

Cold Climate Heating I Series include two electric heaters in the outdoor unit 1. A condensate drain pan heater to prevent freezing 2. A crankcase heater to boil off refrigerant from the compressor to prevent liquid slugging

System Setup Both indoor and outdoor unit are powered off Disconnect the communication wires C1 and C2 Connect the USB-Serial Adapter to C1 and C2 Disconnect the USB-Serial Adapter from the laptop The updater program is closed

Attaching Communication Cable

Outside Unit LED Detail All Five LED s Should Light

MMI BOARD (In Unico Control Box) Both Blue and Green Should be solidly Lit (If programming inside unit)

Diagnostics

Run Service Loggers IS30 outside Unit

Launch the Logger This screen will appear

Set Proper COM port

Assign A File Name Be sure the file is easy to remember for future reference Use today s date and the job address for example

Click Start Run for 15 Minutes

End Diagnostics Click Stop File will save as a.zip file Keep a copy for your records and send an email to service@unicosystem.com Resume normal operations

To Find Firmware Version

Find Indoor Firmware Version

Indoor Version

High Wall Mount

Outdoor Units

Troubleshooting Points to remember: 1. Respect the line lengths 2. Check the matchup matrix 3. Check the dip switches and cables -

Troubleshooting Unico Presentation RAT=Room Air Temp 12V ICT=Indoor Coil Temperature NOTES - The troubles are showed according to a priority list that is, in case of more than one trouble present, is always showed, at first, the one with the highest priority (1 2 3 etc.). - Sensor damaged means a situation where sensor is short-circuited or opened. - In case of damaged sensors, the system (CM, FMO, FMI etc.), if in OFF state, does not start.