FHS-A9020S01. Application: (Intel Corei7-Per) Picture:

Similar documents
FHS-A9025S20. Picture:

Delta Electronics Corp. APPROVAL SHEET PLEASE SEND ONE COPY OF THIS SPECIFICATION BACK AFTER YOU SIGNED APPROVAL FOR PRODUCTION PRE-ARRANGMENT.

Model Name: FHS-A6025B01. Application: Intel Nehalem Socket U Xeon (45nm) W5500/X5500/E5500/L5500 CPU sequence. Pictures

Delta Electronics Corp. APPROVAL SHEET LGA1156

TEMPORARY SPECIFICATION FOR REFERENCE

SPECIFICATION FOR APPROVAL

SPECIFICATION FOR APPROVAL

SPECIFICATION FOR APPROVAL

客戶承認書 SPECIFICATION FOR APPROVAL CUSTOMER P/N: DELTA MODEL: ASB02512VHA-A76N REV: 01 SAMPLE ISSUE DATE: 12/08/2016 QUANTITY:

SPECIFICATION FOR APPROVAL PLEASE SEND ONE COPY OF THIS SPECIFICATION BACK AFTER YOU SIGNED APPROVAL FOR PRODUCTION PRE- ARRANGMENT.

STANDARD. Customer : DC FAN. Description : Customer P/N : rev. : N/A X01. Sample issue date : DEC Quantity :




SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 120X120X25 mm M O D E L : KD1212PTS1-6A

HEX200PB Heat Exchanger Instruction Manual

HEX050QA Heat Exchanger Instruction Manual

SPECIFICATION FOR APPROVAL

AD0412HB-C71GP (P) P.S. REV. DC FAN (RoHS)

SPECIFICATION FOR APPROVAL. Customer Description Part No.. Model No. JDD VBBA51(0A24) Sample Issue No. Sample Issue Date

(P) AD0612VB-A7BGP P.S. REV. DC FAN (RoHS)

Thermalright. Macho 120 Rev.A

Thermalright. Archon IB-E X2

Thermalright. Macho Direct

Thermalright. TRUE Spirit 140 BW Rev.A

Revised Record 研發處發行章 Rev. Revision Description Change page Date A00 Preliminary

Thermalright. Le GRAND MACHO

研發處 研發處 研發處 研發處 簡文榮 林茂盛 AD0612LB-A73GL P.S. REV. DC FAN (RoHS) 研發處

Thermalright. Silver Arrow ITX

Thermalright. TRUE Spirit 120I

+ A B V B NO NC V COM PV PV

Thermalright. Macho Zero

Thermalright AXP-100

Dimension drawing. Main feature. Dimension (H x W x D) Cooling capacity *Note. Standalone temperature control. Rated voltage.

SUNON SPECIFICATION FOR APPROVAL. ISSUE DATE Apple 12/28 REVISION DATE

SUNON SPECIFICATION FOR APPROVAL : SUNON INC : SPEC.NO D G-00 ISSUE DATE Dolphin 7/19 REVISION DATE

FIS30XXseries Gas sensor module SPECIFICATIONS

SPECIFICATION AND PERFORMANCE MDP CONNECTOR SERIES

Specification and Manual

1. SPECIFICATIONS. Dimensions. Tolerance is omitted Unit (mm)

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

PARTS CATALOG MSZ-FH25VE MSZ-FH35VE MSZ-FH50VE INDOOR UNIT. No. OBB623. Models. Revision A: MSZ-FH50VE- E1 has been added. Please void OBB623.

Compact Ultra Low Temperature Chamber

M5800 Pressure Transducer with Rotatable Display

Instruction manual. Please keep safe for future reference

SPECIFICATION FOR APPROVAL

Control Panel Basics Volume 1

SUNON SPECIFICATION FOR APPROVAL. ISSUE DATE Alice

Installation and Operation Guide for the UPS-64C Power Supply with CometFlash

HEB Series. Peltier-Type Thermoelectric Bath

1.0mm PITCH I/O CABLE SHELL CRIMP TOOL

Chemical Thermo-con. How to Order. Communication A RS-485 B RS-232C. Power supply 2 Single-phase: 180 to 242 VAC 50/60 Hz.

SPECIFICATION FOR APPROVAL

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

Thermoelectric Bath. Series HEB

Installation and Operation Guide

Installation Instructions

User s Manual. Model VJRK IM 77J01R21-01E 1. CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT 4. MODEL AND SUFFIX CODES 5.

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

M5800 Pressure Transducer with Rotatable Display

EN , EN , DALI 102/207, SELV Output, KS C 7655 Safety Certification Approved RoHS Compliant. Dim. Method

Submittal Packages Detailed with Items and Reviewers

370, boulevard de Balmont LYON Tel Fax Web:

CO2 Carbon Dioxide Sensor

SUNON SPECIFICATION FOR APPROVAL

10. Circuit Descriptions

SUNON SPECIFICATION FOR APPROVAL

Ceiling Mount Temperature Sensor

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

DESIGN & TECHNICAL MANUAL

Thermoelectric Bath. Series HEB

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

General Specifications

No.THD51E To prevent accidents arising from the use of this product, please ensure the operator using it receives this manual.

THERMAL SYSTEMS, INC. Installation and Operation Manual

Installation Manual. SiCOMS. Oil mist Concentration monitoring Diesel- and `-Version. Part No.: Release: (revision )

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

ES2-HB-N. Ordering Information. Specifications. Temperature/Humidity Sensor ES2-THB-N. Humidity Sensor

B. Section Identification for Fire Suppression Piping and Equipment.

SINGLE SPEED SYRINGE PUMP

Operation and Maintenance Manual Chamber Conditioning Unit, CCU 06. Document Number: EC OM 6847 Revision: 3

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

Draft ES V1.1.1 ( )

OPERATION MANUAL. THE JENCO MODEL 6230 MICROCOMPUTER BASED ph/mv/temp PORTABLE METER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

FULL AUTOMATIC EXTINGUISHING SYSTEM FOR INDUSTRIAL MACHINERY YAC-3A. Table of Contents

UL TEST REPORT AND PROCEDURE

Product Data Sheet 4114 N/17HH-218. The engineer's choice

TEMPERATURE CONTROLLER

1. Description INSTRUCTION FOR AIR BLAST COOLER TYPE COOL 450

ETSI TS V1.2.1 ( )

Thermal Electronics Corp. Service & Parts Manual. Rev.1 07

Series Temperature Controller Instruction Sheet

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Evolution Electric Heat Modulator CONTROLS INC. EVO/ EHM-S3

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

INSTALLATION & OPERATION MANUAL

AC Backward Curved Motorized Impellers

Transcription:

DELTA ELECTRONICS, INC. FHS-A9020S01 2009New LGA1366 Application: (Intel Corei7-Per) Extreme edition sequence Intel LGA1366 Bloomfield(45nm) CPU Core i7 940/920/950 Picture: Thermal & Mechanical Spec.: Thermal performance for 130W CPU HSK Assembly Weight: 540 g (ref.) Clipping Force: 16 Kgf (ref.) Component Specification: 1. Heat Sink Type: Thermal Shrink with Cu core Material: Aluminum A6063 & Cu C1100 or Equivalent. Dimension: 100*100*40 mm 2. Thermal interface material Material: Dow-Corning TC-1996 or Equivalent. 3. Fan (90x20mm with Thermistor & PWM Control) Rated Voltage: 12 V Life Time: Superflo bearing 50000 hrs Connector: a. Lead wire: UL 1430 AWG#26 pin 1: black wire--------(-) pin 2: yellow wire----------(+) pin 3: green wire---------(f00) pin 4: blue wire------------(pwm) b. Housing: Molex 47054-1000 or equivalent c. Terminal: Molex 2759T 08-50-0113 or equivalent * All readings are typical values at rated voltage. * Specifications are subject to change without notice DELTA ELECTRONICS, INC. 252, Shang Ying Road, Kuei San TAOYUAN SHIEN 333, TAIWAN,R.O.C. TEL: 886-3-3591968 EXT 2073 FAX: 886-3-3591991 DELTA PRODUCTS CORPORATION 4405 CUSHING PARKWAY FREMONT, CA 94538, U.S.A. TEL: 1-510-668-5100 FAX: 1-510-668-0680 DELTA ELECTRONICS(JAPAN), INC. DELTA SHIBADAIMON BLDG. 2-1-14 SHIBADAIMON, MINATO-KU, TOKYO, 105-0012, JAPAN TEL: 81-3-5733-1111 FAX: 81-3-5733-1211 DELTA ELECTRONICS EUROPE LTD. WEGALAAN 16, 2132 JC HOOFDDORP, THE NETHERLANDS TEL: 31-23-566-8989 FAX: 31-23-5668910 Date: July-2009

Delta Electronics Corp. APPROVAL SHEET Customer Name.: Model Name.: Model Name.: COOLER FHS-A9020S01 Customer Part No.: Spec Issue Date.: 11/03/2009 Spec Revision : 00 PLEASE SEND ONE COPY OF THIS SPECIFICATION BACK AFTER YOU SIGNED APPROVAL FOR PRODUCTION PRE-ARRANGMENT. Approved By: Date: Approval Check Designer REEK.LI Form No... tmp D029 Form Rev... 00

Delta Electronics Corp. REV. Description Drawn Checked Approved Issue Date 00 ISSUE SPEC REEK.LI 11/3 09 11/3 09 11/3 09 Description: Part No. DELTA MODEL : SAMPLE REVISION CODE LIST REV FHS-A9020S01 TOTAL 25 PAGE 00 Form No... tmp D029 Form Rev... 00

Delta Electronics Corp. CONTENTS Item Element Description Page Note 1 Specification 5 2 Print 6 3 Packing Plan 11 4 Fan 14 Form No... tmp D029 Form Rev... 00

Delta Electronics Corp. 1. SPECIFICATION Characters Item Scope Application Specification a: Thermal Resistance 0.25 ( /W) (REF.) b: total weight 540 g (REF.) c: clip force 16 kgf (REF.) Description THIS SPECIFICATION DEFINES THE ELECTRICAL AND MECHANICAL CHARACTERISTICS OF THE FAN HEATSINK INTEL CPU COOLER BOM Item Part Name Material Part NO. Q TY Remark 1 FAN PBT 3622918011 1 2 HEATSINK AL6063-T5 & Cu1100 3345115400 1 3 FASTENER CAP PC 3470089500 4 4 FASTENER BASE PC 3470415500 4 5 LABEL PE 3266708400 1 6 TIM DOW TC-1996 4021101500 0.14g Form No... tmp D029 Form Rev... 00

2. PRINT Assembly Drawing Delta Electronics Corp. Parts Drawing Form No... tmp D029 Form Rev... 00

Delta Electronics Corp. 3. PACKING PLAN Packing Specification Form No... tmp D029 Form Rev... 00

4. FAN Fan Specification Delta Electronics Corp. Form No... tmp D029 Form Rev... 00

SPECIFICATION FOR APPROVAL Customer TMPBU Description DC FAN Part No. 3622918011 REV. Delta Model No. AUC0912D-9B37 REV. 01 Sample Issue No. Sample Issue Date NOV.03.2009 PLEASE SEND ONE COPY OF THIS SPECIFICAITON BACK AFTER YOU SIGNED APPROVAL FOR PRODUCTION PRE-ARRANGMENT. APPROVED BY: DATE : DELTA ELECTRONICS, INC. TAOYUAN PLANT 252, SHANG YING ROAD, KUEI SAN INDUSTRIAL ZONE TAOYUAN SHIEN, TAIWAN, R.O.C. TEL:886-(0)3-3591968 FAX:886-(0)3-3591991

Application Notice 1. Delta will not guarantee the performance of the products if the application condition falls outside the parameters set forth in the specification. 2. A written request should be submitted to Delta prior to approval if deviation from this specification is required. 3. Please exercise caution when handling fans. Damage may be caused when pressure is applied to the impeller, if the fans are handled by the lead wires, or if the fan was hard-dropped to the production floor. 4. Except as pertains to some special designs, there is no guarantee that the products will be free from any such safety problems or failures as caused by the introduction of powder, droplets of water or encroachment of insect into the hub. 5. The above-mentioned conditions are representative of some unique examples and viewed as the first point of reference prior to all other information. 6. It is very important to establish the correct polarity before connecting the fan to the power source. Positive (+) and Negative (-). Damage may be caused to the fans if connection is with reverse polarity, if there is no foolproof method to protect against such error specifically mentioned in this spec. 7. Delta fans without special protection are not suitable where any corrosive fluids are introduced to their environment. 8. Please ensure all fans are stored according to the storage temperature limits specified. Do not store fans in a high humidity environment. We highly recommend performance testing is conducted before shipping, if the fans have been stored over 6 months. 9. Not all fans are provided with the Lock Rotor Protection feature. If you impair the rotation of the impeller for the fans that do not have this function, the performance of those fans will lead to failure. 10. Please be cautious when mounting the fan. Incorrect mounting of fans may cause excess resonance, vibration and subsequent noise. 11. It is important to consider safety when testing the fans. A suitable fan guard should be fitted to the fan to guard against any potential for personal injury. 12. Except where specifically stated, all tests are carried out at room (ambient) temperature and relative humidity conditions of 25 o C, 65% RH. The test value is only for fan performance itself. 13. Be certain to connect an 4.7µF or greater capacitor to the fan externally when the application calls for using multiple fans in parallel, to avoid any unstable power. Doc. No: FMBG-ES Form 001 Rev. 0001 Date: June 24, 2009