Owner s Manual. Filterless UV Air Purifier. This Manual Includes:

Similar documents
by Owner s Manual For use with model: AA250 For safety and to ensure proper use carefully read the contents of this manual before operating the unit.

Air Purifier. User s Guide. Important! Oreck Air Purifier with HEPA Filtration. Read this manual carefully, and keep for future reference.

AirInstinct Air Purifier

For use with models: BP , BP , BP

Cordless Electric Broom

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

UV100E Ultraviolet Air Treatment System

OWNER S MANUAL. Important: Read carefully before assembly and use. PORTABLE CANISTER U #961A00007 ID111867

Pressurized Filter Up to 1250 gallons

DUST FREE CARBON Whole House Air Purifier

Grab-It & Steam-It. User s Guide. Powerful, Lightweight & Durable Power Broom & Steam Mop. Important!

Air Pump Up to 800 gallons

Family size Glasstop warming tray WITH TEMPERATURE CONTROL

20 INCH ELECTRIC GRIDDLE

Ozone + UV Sanitation

CORDLESS GLASS ELECTRIC KETTLE WITH BONUS TEA INFUSER

TOWER AIR PURIFIER FOR THE FOLLOWING MODEL : EE-5068

UVIOOAUltravioletSystem

Towel Warmer. Luxurious warmth for towels, robes and blankets

RJ11-17-TI CORDLESS GLASS ELECTRIC KETTLE. CUSTOMER SERVICE:

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Projection Alarm Clock USER GUIDE

IMPORTANT SAFETY INFORMATION:

OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS WHOLE ROOM RADIATOR HEATER. Model: HO-0221 THERMOSTAT

ELECTRIC FIREPLACE OWNER S MANUAL

UV100A Ultraviolet System

FRESHAIR USER S MANUAL. CAUTION: Read manual carefully for proper procedures and operation.

IMPORTANT SAFETY INFORMATION:

IMPORTANT SAFETY INFORMATION:

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

Instruction Leaflet. Read instructions before operating. Retain for future reference.

BioZone Scientific International contact information

BLT-999W-2 Item # 60757

IMPORTANT SAFETY INFORMATION:

OWNER S MANUAL ADVENTURER SERIES. Electric Grill A10-603E

ARMITAGE CEILING FAN ITEM # MODEL #CC52WW5L. Español p. 17 ATTACH YOUR RECEIPT HERE. Purchase Date

MODEL: DFH-IQH-62-01, DFH-IQH-62-02, DFH-IQH-62-03, DFH-IQH-62-04, DFH-IQH-62-05,DFH-IQH-06

Indoor/Outdoor Electric Patio Heater Model No: HP Operating Instructions HP Soleus Air International

IMPORTANT SAFETY INFORMATION:

FAN-FORCED UTILITY HEATER

6 Sheet Strip-Cut Shredder for Home/Office

Retro Flip Alarm Clock MODEL: CH1200/1/2

ITEM # BUILDER S SERIES CEILING FAN MODEL #41391

IMPORTANT SAFETY INFORMATION:

Instruction Leaflet. Read instructions before operating. Retain for future reference.

MINI ELECTRIC CONVECTION HEATER

HAND BLENDER USER GUIDE READ ALL INSTRUCTIONS BEFORE USE AFTER SALES SUPPORT

VersaBrew SINGLE SERVE COFFEE MAKER USER GUIDE

User s Manual & Operating Instructions

9.5 OSCILLATING AIR CIRCULATOR FAN Instruction Manual

Model CWA200 Owner s Manual

RECHARGEABLE CYCLONIC VACUUM CLEANER WITH POWER BRUSH

RJ07-M-SS DEEP FRYER FRY GUY. CUSTOMER SERVICE: RJ07-M-SS

Earn BISSELL Rewards! Register your

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4-5. Replacement Element Installation 5. Replacement Parts 5-6

ADORABLE Air Purifiers

SSF1610B-CN TRUSTED FOR OVER 100 YEARS. 16 inch (40cm) Oscillating. Stand Fan. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

23-IN Electric Logset

PCO/UV N-Duct Model. Owner s Guide

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE

RJ17-V2 Series. Hand Mixer. CUSTOMER SERVICE:

FIREPLACE HEATER FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R

OPERATION & INSTALLATION MANUAL AIR PURIFICATION SYSTEM (APS300)

The Fry Guy Deep Fryer

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

75 Sheet Micro-Cut Shredder With CD/DVD Slot

Instruction Leaflet. Read instructions before operating. Retain for future reference.

IMPORTANT SAFETY INFORMATION:

ELECTRIC STOVE MODEL CGESS SAFETY INFORMATION AND OPERATION MANUAL

CERAMIC FAN HEATER MODEL # EE If you have any questions about the operation of your ceramic heater, please contact Crane Customer Care.

Dayton Electric Infrared Fireplace User Manual

Operator s Manual. The Quietek

YOUR PORTABLE AIR PURIFIER

YOUR AROMATHERAPY DIFFUSER

ITEM # , , PAWTUCKET CEILING FAN MODEL #40958, 40959, 40047

OWNER S MANUAL CARTER FIREPLACE. Product code: UPC code: Date of purchase: / /

gamma pond Ultraviolet Sterilizers

Rainsoft Division of Aquion, Inc East Lunt Avenue Elk Grove Village, Illinois or

Murano Shower Cabin Installation Instruction

Sound Soother 20 Soothing Sounds

PERSONAL CERAMIC HEATER

6-Quart Backpack Vacuum

Rechargeable UV-A LED/Emergency Light

IMPORTANT SAFEGUARDS

Owner s Manual PUH1500. Electric Umbrella Heater. Model Number: Model Number Part Number. Quality checked by: R00

Juna Ceiling Fan JU54. Installation Instructions Instrucciones de instalación Instructions d installation

ARUBA SUN SERIES - LIGHTING SYSTEM USER MANUAL

SFH136-CN TRUSTED FOR OVER 100 YEARS. Sunbeam Heater. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

INTELLICRISP WAFFLE MAKER INSTRUCTION MANUAL MODEL: CKCLWF1. Calphalon_WaffleMaker_IB_SPEC_DarkGrey_CKCLWF1_19EM1.indd 1 1/25/19 09:30

Installation and Operation Instructions Luxury Towel Warmer Free Standing or Wall Mounted

TOUCHDOWN 48 CEILING FAN

Thanks for shopping with Improvements! Solar Pool Heater XF Item #

SUPER NOVA SERIES UV STERILIZER HIGH INTENSITY ULTRAVIOLET STERILIZATION

TECHNOLOGY CORP. Taking a bite out of energy costs. Instruction Manual for the ORKA Remote Thermostat/Humidity Controller.

TPP440. owner s guide. air purifier with uv light. air purifier with uv light TP

1500 Watt OIL FILLER RADIATOR INSTRUCTION MANUAL. pure indoor living MODEL BOF2001-CN

ELECTRIC CONVECTION HEATER WITH FAN AND TIMER

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

OWNER S MANUAL

BLOWER ACCESSORY MODEL #FIB100 Español p. 17

Transcription:

Filterless UV Air Purifier Item No. 203758 Owner s Manual This Manual Includes: Warranty Safety Warnings Operating Instructions Replacement Directions Troubleshooting Tips Cleaning and Maintenance Tips Before operating this unit, carefully read the contents of this manual.

Read all instructions carefully before operating your air purifier. Table of Contents Table of Contents 1 Safety Instructions and Cautions 2 Warranty 3 Maintenance and Customer Service 4 Placement and Operation 4 Cleaning 4 AHPCO Cell Replacement 5-6 Troubleshooting Guide 7 1

Important Safety Instructions When operating electrical appliances, basic precautions should always be followed. WARNING To reduce the risk of fire, electric shock or injury: Do not use outdoors or on wet surfaces. Use only as described in this manual. Do not use with a damaged cord or plug. If appliance is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, call Customer Service at 1-877-210-3449. Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord. Do not handle plug or appliance with wet hands. Do not put any object into openings. Turn off all controls before unplugging. Replacement Date Reminder The AHPCO Cell should be replaced at least every three years. Replacement Date: Hg lamp contains mercury. Manage in accord with disposal laws. Find disposal centers at www.earth911.org. CAUTION AHPCO Cell contains Hg (Mercury) and should be disposed of according to disposal laws. Find disposal centers at www.earth911.org. If the UV lamp is broken do not touch the cell or glass with your hands. UV lamp may be hot and could cause serious burns if not handled properly. Please wait until the AHPCO Cell has cooled to room temperature to remove from unit. WARNING: UV Light Hazard. Harmful to skin and eyes. Can cause temporary or permanent loss of vision. Never look at the lamp while illuminated. To prevent exposure to ultraviolet light, be sure the power is disconnected before servicing. WARNING: RISK OF ELECTRICAL SHOCK. CAN CAUSE INJU- RY OR DEATH: UNPLUG OR DISCONNECT UNIT FROM POWER SUPPLY BEFORE SERVICING. 2

Warranty Sharper Image gives you the following limited warranty for this product only if it was originally purchased directly from Sharper Image. Sharper Image will repair or replace, free of charge, to the original purchaser, any part that is found to be defective in material or workmanship within one (1) year of the date of purchase. This limited warranty covers the replacement of expendable or consumable parts such as the AHPCO Cell for one (1) year. This limited warranty does not apply to any part subjected to accident, abuse, industrial use, alteration, misuse, damage caused by act of God, the use of voltages other than indicated on the label displayed on this product or service of this product by anyone other than Sharper Image. Sharper Image does not authorize any person or representative to assume or grant any other warranty obligation with the sale of this product. Sharper Image s limited warranty is valid only if you retain proof of purchase from Sharper Image or a Sharper Image Authorized Retail Dealer for this product. If you purchase this product from any other source, your purchase is AS IS, which means Sharper Image grants you no warranty, and that you, not Sharper Image, assume the entire risk of the quality and performance of this product, including the entire cost of any necessary servicing or repairs of any defects. Sharper Image s liability for damages to you for any costs whatsoever arising out of this statement of limited warranty shall be limited to the amount paid for this product at the time of original purchase, and Sharper Image shall not be liable for any direct, indirect, consequential or incidental damages arising out of the use or inability to use this product. ALL EXPRESS AND IMPLIED WARRANTIES FOR THIS PRODUCT, INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE WARRANTY PERIOD, AND NO WARRANTIES, WHETHER EXPRESS OR IMPLIED, WILL APPLY AFTER THIS PERIOD. Some states do not allow limitations on the duration of implied warranties, so the above limitation may not apply to you. This warranty gives you speci ic legal rights, and you may also have other rights which vary from state to state. For return authorization and a prepaid return label, call 1-877-714-7444. 3

Maintenance and Customer Service If you require any additional information or have problems with your Sharper Image appliance, you may call Customer Service at: 1-877-714-7444. Please have your serial and model numbers, found on bottom of unit, handy when calling. Save your sales receipt to show if your Sharper Image appliance should ever need any warranty service. Placement and Operation For best results the unit should be placed in a central location, and three feet or higher from the ground. Operation is very simple. Remove the device from the packaging. Place it in the desired location, plug it in and rock the switch to the on position. The unit can remain in the on position 24/7. Off / On Switch Optional Cleaning Make sure that the power cord is unplugged prior to cleaning. Base and Honeycomb - We recommend wiping with a dry towel to remove dust and build up. Aluminum Shell - We recommend using stainless steel/aluminum spray on polish or multi-surface cleaners. Make sure the polish or cleaner is recommended for use on aluminum. Internal - Take a dry cloth and wipe inside the shell and around the aluminum brackets and the ballast or spray with compressed air. NOTE: Use compressed air only to clean the AHPCO Cell. Any removal of catalyst coating will decrease the effectiveness of your unit and void the warranty. 4

AHPCO Cell Replacement Step 1 CAUTION: Before attempting to service the Sharper Image unit, be sure the power is off and unplugged. DANGER - NEVER LOOK DIRECTLY AT ILLUMINATED AHPCO CELL WARNING OPTICAL RADIATION EXPOSURE HAZARD DO NOT ATTEMPT TO OPERATE UNIT WITHOUT ALLUMINUM SHELL COVERING AHPCO CELL. DO NOT ATTEMPT TO REPLACE AHPCO CELL WITHOUT DISCONNECTING POWER. PERMANENT EYE AND SKIN DAMAGE MAY RESULT. 1. Remove two (2) screws at the bottom sides holding outer shell in place. Then slide the shell up and off of the internal base. 2. Use a 5/16 inch socket to remove the nuts from the AHPCO Cell. Step 2 3. Grasp the AHPCO Cell and pull upward to release from bracket then remove the lamp connector. Step 3 CAUTION UV lamp may be hot and could cause serious burns if not handled properly. Please wait until AHPCO Cell has cooled to room temperature to remove from unit. 5

Step 4 4. Connect the lamp connector securely onto the AHPCO Cell. 5. Use a 5/16 inch socket to tighten nuts to secure the AHPCO Cell. Step 5 6. Slide shell down onto base and replace screws. (Cord and switch are to the back.) Step 6 6

Troubleshooting Guide Problem Reason Solution Unit does not turn on. There is a beeping sound. 1. Power Supply 2. Switch 3. AHPCO Cell 1. Defective AHPCO Cell or the AHPCO Cell is unplugged 1. Check to make sure power supply is plugged in. 2. Check to make sure switch is in the on position. 3. Check to make sure UV lamp within AHPCO Cell in plugged in completely. 1. Check to make sure the AHPCO Cell s four pins are plugged in completely and the cell has a blue glow. If you see no glow, contact Sharper Image Customer Service. Customer Service number: 1-877-210-3449 (TOLL FREE) Monday - Friday, 9:00 a.m. to 6:00 p.m. EST Email customerservice@sharperimageonline.com. Please include where the product was purchased from, as well as the date that the product was purchased. Sharper Image name and logo are registered trademarks. Manufactured and Marketed by Camelot SI, LLC under license. Sharper Image. All Rights Reserved.