SC Installation, Operation & Application Guide

Similar documents
SC Installation, Operation & Application Guide

SC Installation, Operation & Application Guide

SC Installation, Operation & Application Guide

SC Installation, Operation & Application Guide

SC Installation, Operation & Application Guide

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

SC Installation, Operation & Application Guide

Programmable Thermostat

Thermostats. Digital Programmable. GEAppliances.com

Thermostats. Digital Non-Programmable. GEAppliances.com. Owner s Manual & Installation Instructions RAK148D2 RAK164D2

Digital Non-Programmable

RC-101 Heat Pump Real Time Pricing System 2 Stage Heat / 1 Stage Cool

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat

Digital Programmable

Interrupted Ignition Series Oil Primary Control

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION. Premier Series

Installer Guide. WARNING Important Safety Information. 1 Specifications

USER MANUAL 2000NC MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. Builder Series 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat

WARNING Important Safety Information

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

Smart Temp. Model

Owner s Manual. Digital Thermostat

WARNING Important Safety Information

Installer Guide. WARNING Important Safety Information. 1 Specifications

Owner s Manual. Digital. Heat Pump. 5+2 Day Programmable. Model S1-THEH21P5S HVAC SERVICE PARTS TM

Owner s Manual. 5+2 Day Programmable Digital Thermostat

WARNING Important Safety Information

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

ICM 275. Replacement Description

WARNING Important Safety Information

WARNING Important Safety Information

USER MANUAL WARNING! CONTENTS MODEL SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING

AMANA PHWT-A200 THERMOSTAT

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

T-32-TS Touchscreen Thermostat. Installation Manual

7-Day. Digital Thermostat. residential. & 2-cool

INSTALLATION MANUAL. Need Help? This manual covers the following models: T915. Power Type. Thermostat Applications Guide. Page.

ICM Simple Systems. CC750 Comfort Control Center CC and CC Application Guide

Programmable Thermostat

Programmable 5-2 Day Digital Thermostat

Installation, Start-Up, and Operating Instructions

7-DAY or 5/2-DAY PROGRAMMABLE, OR NON-PROGRAMMABLE THERMOSTAT INSTALLATION AND OPERATING INSTRUCTIONS

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

Installation, Programming and Operating Guide for Digital, Programmable Thermostat with Smart Fan Technology. with SFT (Smart Fan Technology )

5+2 Day. up to HEAT COOL

INSTALLATION MANUAL. Need Help? This manual covers the following models: T755. Power Type. Thermostat Applications Guide. Page.

DAY/TIME Button: Selects hour, minute and day setting.

WARNING Important Safety Information

INSTALLER S & OWNER S MANUAL

6 Setting Your Program Schedule 7 Operating Your Thermostat 8 Additional Operation Features 9 Thermostat Maintenance

5+2 DAY PROGRAMMABLE DIGITAL THERMOSTAT

6 Setting Your Program Schedule 7 Operating Your Thermostat 8 Additional Operation Features 9 Thermostat Maintenance

INSTALLER S & OWNER S MANUAL

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

WARNING Important Safety Information

ELECTRONIC COMMUNICATING THERMOSTAT

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

DAY/TIME Button: Selects hour, minute and day setting.

Comfort System T-21-P Touchscreen Thermostat Installation Manual

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEM22P7S COMMERCIAL. Model HVAC SERVICE PARTS

Installation and Programming Instructions for. Deluxe Programmable Thermostats

Installation, Start-Up, and Operating Instructions

Emerson Blue Easy Set 1H/1C

CT500 Electronic Thermostat

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

9901i 9915i 9920i. User's Manual. Menu Driven Display. Fresh Air Control DELUXE PROGRAMMABLE THERMOSTATS

RC-90 / RC-90B Single Stage Heat/Cool Thermostat for Zone Control Systems Installation Instructions

Safety & Installation Instructions

Programmable Thermostat

CommStat 4 Controller

2. All connections are 24 volt AC. Verify all planned connections at TT thermostat connections, before turning on power

Owner s Manual. Part Number 33CSSP2-FC BACK LIT LIQUID CRYSTAL DISPLAY MODE BUTTON

CT2700 An Electronic Round Programmable Thermostat

1 For All Programmable Digital Thermostat

9901i 9915i 9920i. User's Manual. Menu Driven Display. Fresh Air Control DELUXE PROGRAMMABLE THERMOSTATS

Isolation Relay: If Needed. # 9. NO relay for TT To Thermostat NO relay. MZ308 Exquisite Heat Controller

INSTALLATION & OPERATION MANUAL

Small Digital Thermostat Controller Temperature Control

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Commercial Touchscreen Thermostat

Operator: Save these instructions for future use!

1 For All Programmable or Non-Programmable. Digital Thermostat. Meets Residential California Title 24

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

Product Manual SZ1009

RC-2000 Thermostat Installation Instructions

For Quick Set-Up go to Page 14

INSTALLATION MANUAL. Need Help? This manual covers the following models: T725. Power Type. Thermostat Applications Guide. Page.

Programmable Digital Thermostat

I2:00 Mo MODEL TSTATBBPB501 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

OWNER S MANUAL Venstar Inc. 08/07

User s Manual

INSTALLATION MANUAL. This manual covers TopTech models: TT-S-755H. Need Help? Thermostat Applications Guide. Power Type. Table of Contents.

RTH8500 Series. Quick Installation Guide. Included in your box. Programmable Thermostat. Quick Install Guide Screws and anchors. RTH8500 Thermostat

ACONT600AF11MA Programmable Comfort Control

User's Manual. Menu Driven Display DELUXE PROGRAMMABLE THERMOSTATS

INSTALLATION MANUAL. This manual covers TopTech models: TT-N-851. Need Help? Power Type. Thermostat Applications Guide. Page.

Transcription:

SC 3801 2 Heat/2 Cool 7-Day Programmable Hardwired Programmable Electronic Thermostat Programmable and Configurable Single/Dual Stage Heat Pump Systems Single/Dual Stage Heat/Cool Systems Backlit Display Auto Changeover Simpleset 7 Day Programming Compatible with Gas, Oil, or Electric Title 24 Compliant/No Batteries Required Relay Outputs (minimum voltage drop in thermostat) Ideally Suited for: Residential (New Construction/Replacement), Light Commercial Installation, Operation & Application Guide For more information on our complete range of American-made products plus wiring diagrams, troubleshooting tips and more, visit us at www.icmcontrols.com

Table of Contents Specifications...1 Important Safety Information...1 Package Contents/Tools Required...1 To Remove Existing Thermostat...2 To Install Thermostat...2 Remote Sensor Installation (Optional)...4 Wiring Diagrams... 5-6 Wiring Diagram Conversions... 7-18 Configuration Mode... 19-22 Testing the Thermostat...23 Mode of Operation...24 Operating Modes...25 Setting the Time and Day of the Week...26 Programming...27 Simpleset Programming...29 Lockout Function...29 Factory Preprogramming...30 Personal Program Schedule...30 Troubleshooting...33

Specifications Electrical rating: 24 VAC (18-30 VAC) 1 amp maximum per terminal 4 amp maximum total load Temperature control range: 45 F to 90 F (7 C to 32 C) Accuracy: ± 1 F (± 0.5 C) System configurations: 2-stage heat, 2-stage cool, heat pump, gas, oil, electric Terminations: R, C, W1/O/B, Y1, W2, Y2, G, S1, S2 Important Safety Information WARNING!: Always turn off power at the main power supply before installing, cleaning, or removing thermostat. This thermostat is for 24 VAC applications only; do not use on voltages over 30 VAC Do not short across terminals of gas valve or system control to test operation; this will damage your thermostat and void your warranty All wiring must conform to local and national electrical and building codes Do not use air conditioning when the outdoor temperature is below 50 degrees; this can damage your A/C system and cause personal injuries Use this thermostat only as described in this manual Package Contents/Tools Required Package includes: SimpleComfort 3801 programmable thermostat on base, labeled thermostat cover, wiring labels, screws and wall anchors, Owner s Manual, Installation, Operation and Application Guide. Tools required for installation: Drill with 3/16 bit, hammer, screwdriver.

ELECTRICAL SHOCK HAZARD Turn off power at the main service panel by removing the fuse or switching the appropriate circuit breaker to the OFF position before removing the existing thermostat. 1. Turn off power to the heating and cooling system by removing the fuse or switching the appropriate circuit breaker off. 2. Remove cover of old thermostat. This should expose the wires. 3. Label the existing wires with the enclosed wire labels before removing wires. 4. After labeling wires, remove wires from wire terminals. 5. Remove existing thermostat base from wall. To Remove Existing Thermostat 6. Refer to the following section for instructions on how to install this thermostat. To Install Thermostat ELECTRICAL SHOCK HAZARD Turn off power at the main service panel by removing the fuse or switching the appropriate circuit breaker to the OFF position before removing the existing thermostat. IMPORTANT: Thermostat installation must conform to local and national building and electrical codes and ordinances. Note: Mount the thermostat about five feet above the floor. Do not mount the thermostat on an outside wall, in direct sunlight, behind a door, or in an area affected by a vent or duct. 1. Turn off power to the heating and cooling system by removing the fuse or switching the appropriate circuit breaker off.

To Install Thermostat (continued) 2. To remove cover, insert and twist a coin or screwdriver in the slots on the sides of the thermostat. 3. Put thermostat base against the wall where you plan to mount it (Be sure wires will feed through the wire opening in the base of the thermostat). 4. Mark the placement of the mounting holes. 5. Set thermostat base and cover away from working area. 6. Using a 3/16 drill bit, drill holes in the places you have marked for mounting. 7. Use a hammer to tap supplied anchors in mounting holes. 8. Align thermostat base with mounting holes and feed the control wires through wire opening. 9. Use supplied screws to mount thermostat base to wall. 10. Insert stripped, labeled wires in matching wire terminals. See Wiring Diagrams section of this manual (Pages 5 to 18). If using optional remote sensor, see Remote Sensor Installation (Page 4). CAUTION!: Be sure exposed portion of wires does not touch other wires. 11. Tighten screws on terminal block. Gently tug wire to be sure of proper connection. Double check that each wire is connected to the proper terminal. 12. Seal hole for wires behind thermostat with non-flammable insulation or putty. 13. Replace cover on thermostat by snapping it in place. 14. Turn on power to the system at the main service panel. 15. Test thermostat operation as described in Testing the Thermostat (Page 23).

Remote Sensor Installation (Optional) 1. Remove cover from remote sensor housing. 2. Select an appropriate location for mounting the remote sensor. 3. Mount remote sensor unit using hardware provided. 4. Install two strand shielded wire between remote sensor and thermostat. Shielded wire must be used. Do not run remote sensor wire in conduit with other wires. Wire 1 should run between the S1 terminal on the thermostat and the S1 terminal on the remote sensor Wire 2 should run between the S2 terminal on the thermostat and the S2 terminal on the remote sensor Connect the shielding of the wire to the S2 terminal on the thermostat 5. Select correct option for monitoring temperature. To monitor temperature with remote sensor only, cut R12 from thermostat circuit board To average the temperatures of the remote sensor and the sensor of the SC3801, do not remove R12 Cut R12 from circuit board for remote sensor use only. Leave R12 as is for averaging operation.

Wiring Diagrams First Heating Control First Cooling Control First Cooling Control Second Heating Control Second Cooling Control Fan Control Second Cooling Control Fan Control

Wiring Diagram (continued) First Heating Control First Heating Control Second Heating Control Second Heating Control Fan Control

Wiring Diagram Conversions SimpleComfort 3801 Electronic Thermostat Conversion to: Carrier Split Stream Condensers and Heat Pump Systems SC 3801 Electronic Thermostat Carrier Split Stream

SimpleComfort 3801 Electronic Thermostat Conversion to: Coleman 3000 Series Heat Pump Systems SC 3801 Electronic Thermostat

SimpleComfort 3801 Electronic Thermostat Conversion to: Comfortmaker CYC Series Heat Pump Systems SC 3801 Electronic Thermostat

SimpleComfort 3801 Electronic Thermostat Conversion to: Heil-Quaker 867.814 Series and PH50 Series Heat Pump Systems SC 3801 Electronic Thermostat 10

SimpleComfort 3801 Electronic Thermostat Conversion to: Payne Reliant and Endura Model Heat Pump Systems SC 3801 Electronic Thermostat 11

SimpleComfort 3801 Electronic Thermostat Conversion to: Rheem/Ruud: -PGB, -PFA, -PCB, -PLA, and -PKA Series Heat Pump Systems SC 3801 Electronic Thermostat 12

SimpleComfort 3801 Electronic Thermostat Conversion to: Goodman, Janitrol, Trane/American Standard Heat Pumps Note 1: X2 terminal on Goodman PCD capped Note 2: T terminal on Goodman PCD capped SC 3801 Electronic Thermostat 13

SimpleComfort 3801 Electronic Thermostat Conversion to: York E1CS, E1FB, E1FH Heat Pump Systems SC 3801 Electronic Thermostat 14

SimpleComfort 3801 Electronic Thermostat Conversion to: Lennox CB19 Heat Pump Systems Note 1: E terminal on Lennox PCD capped Note 2: L terminal on Lennox PCD capped SC 3801 Electronic Thermostat 15

SimpleComfort 3801 Electronic Thermostat Conversion to: Lennox HP19 and HP20 Heat Pump Systems SC 3801 Electronic Thermostat 16

SimpleComfort 3801 Electronic Thermostat Conversion to: Lennox HP21 With CB21 PCB Heat Pump Systems Note 1: E terminal on Lennox PCD capped Note 2: L terminal on Lennox PCD capped SC 3801 Electronic Thermostat 17

SimpleComfort 3801 Electronic Thermostat Conversion to: Lennox HP22 With CB19 PCB Heat Pump Systems Note 1: E terminal on Lennox PCD capped Note 2: L terminal on Lennox PCD capped SC 3801 Electronic Thermostat 18

The configuration mode is used to set the SC3801 to match your heating/cooling system. The SC3801 functions with heat pump, air conditioning, gas, oil, or electric heat systems. 1. To enter the configuration mode, simultaneously hold down the and buttons while the SC3801 is in OFF mode. 2. Press the or button to change settings within each screen. 3. Press the button to advance to the next screen. Note: The button will return you to the previous screen. 4. To exit configuration mode, hold in the button for 6 seconds. Configuration Mode Settings Configuration Mode The setup screens for configuration mode are as follows: 1. Heat pump Press the or button to configure as heat pump or non-heat pump system. ON = Heat pump system OFF = Non-heat pump system Press the button to advance to the next screen. 2. Reversing valve appears only if heat pump is set to ON. Press the or button to set reversing valve. If your reversing valve is energized in heat mode, set to b. If the reversing valve is energized in cool mode, set to o. Press the button to advance to the next screen. 3. HEAT, ELECTRIC, or GAS/OIL appears only if heat pump setting is OFF. Press the or button to set heat type. For electric heat (interlocked), set ELC ON For gas or oil heat (non-interlocked), toggle ELC OFF Press the button to advance to the next screen. 19

Configuration Mode Settings (continued) 4. Temperature scale (F or C) Choose Fahrenheit or Celsius. Press the or button to select. Press the button to advance to the next screen. 5. Stage 1 Differential (1 F to 3 F) (1 C to 2 C) Set the number of degrees between your turn on temperature and your setpoint temperature. Press the or button to set differential value. Press the button to advance to the next screen. 6. Stage 2 Differential (1 F to 6 F) (1 C to 3 C) Set the number of degress between when Stage 1 turns on and when Stage 2 turns on. Press the or button to set differential value. Press the button to advance to the next screen. 7. Deadband (1 F to 9 F) (1 C to 5 C) Set the minimum number of degrees between your heating system activation and your cooling system activation. Press the or button to set deadband value. Press the button to advance to the next screen. 8. Staged off outputs Select whether the outputs for heating and cooling are staged off independently or are satisfied simultaneously. 1 = Economy Mode Outputs are staged on and off in accordance with setpoint and differential. 0 = Comfort Mode Outputs are staged on and all stages cycle off simultaneously when set point is satisfied. Press the or button to select. Press the button to advance to the next screen. 9. Fan ON Delay HEAT cycle (0-120 seconds) Time fan is delayed turning ON at start of heat cycle. For no delay, set to 0:00 (appears only for heat pump or electric heat systems). 20 Press the or button to set delay. CAUTION!: Changing from the default of 0:00 may permanently damage your system. Press the button to advance to the next screen.

Configuration Mode Settings (continued) 10. Fan OFF Delay HEAT cycle (0-240 seconds) Time fan is delayed turning OFF after heat cycle. For no delay, set to 0:00. Note: This appears only for heat pump or electric heat systems. Press the or button to set delay. CAUTION!: Changing from the default of 0:00 may permanently damage your system. Press the button to advance to the next screen. 11. Fan ON Delay COOL cycle (0-120 seconds) Time fan is delayed turning ON at start of cool cycle. For no delay, set to 0:00. Press the or button to set delay. CAUTION!: Changing from the default of 0:00 may permanently damage your system. Press the button to advance to the next screen. 12. Fan OFF Delay COOL cycle (0-240 seconds) Time fan is delayed turning OFF after cool cycle. For no delay, set to 0:00. Press the or button to set delay. CAUTION!: Changing from the default of 0:00 may permanently damage your system. Press the button to advance to the next screen. 13. Maximum run cycles allowed per hour (d, 2-6). d = as many as needed, 2-6 = maximum cycles/hour Press the or button to select. Press the button to advance to the next screen. 14. Auxiliary Delay ON (0-30 minutes) For heat pump systems only. Set the delay time in minutes for auxiliary heat to be locked out after a call for second stage. Press the or button to select. Press the button to advance to the next screen. 21

Configuration Mode Settings (continued) 15. Status indicator (0, 1, 2) Choose when status indicator LED (green, red) illuminates. 0 = Status indicator never on 1 = Status indicator on with first stage 2 = Status indicator on with second stage Press the or button to select. Press the button to advance to the next screen. 16. Lockout (0 F to 8 F, NITE, COOL-HEAT) Select the number of degrees set temperature can be changed during keypad lockout or select to lockout during NITE period only. COOL-HEAT lockout allows adjustment of the set temperatures to the maximum heat set temperature selected in Step 17 and minimum cool set temperature selected in Step 18. Note: The mode cannot be changed when the thermostat is locked. Press the or button to select. Press the button to advance to the next screen. 17. Maximum Heat Setpoint (45 F to 90 F) (7 C to 32 C) Adjust to control the maximum Heat set temperature allowed. Press the or button to select. Press the button to advance to the next screen. 18. Minimum Cool Setpoint (45 F to 90 F) (7 C to 32 C) Adjust to control the minimum Cool set temperature allowed. Press the or button to select. Press the button to advance to the next screen. 19. Room Temperature Offset (+9 F to -9 F) (+5 C to -5 C) Adjust to calibrate displayed room temperature to match actual room temperature. Press the or button to select. To exit Configuration Mode, hold in the button for 6 seconds. 22

Testing the Thermostat Once the thermostat is installed, it should be thoroughly tested. CAUTION!: Do not energize the air conditioning system when the outdoor temperature is below 50 degrees. It can result in equipment damage or personal injury. Cool Test 1. Press mode button until cool mode screen is displayed. 2. Adjust set temperature so it is 5 degrees below room temperature. 3. Air conditioning should come on within a few seconds. 4. Adjust the set temperature 2 degrees above the room temperature and the A/C should turn off. There may be a fan delay on your system. Note: There is a four minute time delay to protect the compressor. after it turns off. To temporarily bypass the four minute delay, press the button four times. Heat Test 1. Press mode button until heat mode screen is displayed. 2. Adjust the set temperature so it is 5 degrees above the room temperature. 3. Heat should come on within a few seconds. 4. Adjust the set temperature so it is 2 degrees below the room. temperature and the heat should turn off. There may be a fan delay on your system. Note: For heat pumps, there is a four minute time delay to protect the compressor after it turns off. To temporarily bypass the four minute delay, press the button four times. 23

Mode of Operation The SC3801 is a programmable, auto changeover, two stage heat, two stage cool thermostat. It functions with air conditioning, heat pumps, gas, oil, or electric heat. The thermostat activates a heating appliance when the room temperature is below the set heat temperature (by the differential temperature). The red status indicator may come on with first or second stage, depending on configuration. When the room temperature drops further, the second stage (auxiliary) heat is activated. The heating is staged off when the room temperature increases. With heat pumps, the thermostat will not let the compressor come on for four minutes after it turns off. This protects your compressor. Emergency heat mode can be used to bypass heat pump operation, making auxiliary heat first stage. When the room temperature is greater than the set cool temperature (by the differential temperature), the first stage cooling device is activated. The green status indicator may come on with first or second stage, depending on configuration. If the room temperature increases, the second stage cooling device will be activated. The cooling is staged off when the room temperature decreases. The thermostat will not let the compressor come on for four minutes after it turns off. This protects your compressor. The SC3801 has the following operating modes: OFF, Heat, Emergency Heat, Cool, Cool and Heat, and Program mode. In OFF mode, the thermostat will not turn on heating or cooling devices. The indoor fan can be turned on in all operating modes using the fan switch. In the Heat mode, the thermostat controls the heating system. Emergency Heat mode can be utilized if a heat pump malfunction occurs. In the Cool mode, the thermostat controls the cooling system. In the Cool and Heat mode, the thermostat controls both the cooling and heating systems. In Program mode, the thermostat will automatically be controlled by the set program. Program mode can function with Heat mode, Cool mode, Cool and Heat mode or OFF mode (for Programmable fan option only). The clock display alternates with the set temperature display for Cool and Heat mode. The program schedule can be overridden by changing the set temperature ( or ). This puts the SC3801 thermostat into a 2-hour temporary hold. After 2 hours, it will automatically return to the program schedule. The SC3801 also has a button lockout feature. This enables the thermostat to be set to the proper mode and temperature and locked so it cannot be tampered with. 24

Operating Modes Program Overview These are the possible operating modes for the SC3801 OFF Mode In this mode, the thermostat will not turn on the heating or cooling devices. Note 1: The indoor fan can be turned on manually in every operating mode by sliding the Auto/On switch to ON. Note 2: To enter Programming Fan Only Mode, press the button once. Only the indoor fan will operate during that period if it is activated in the program setup. Cool Mode In this mode, the thermostat controls the cooling system. Note: There is a four-minute delay for your compressor to restart after it has turned off. Heat Mode In this mode, the thermostat controls the heating system. Note: For heat pumps, there is a four-minute delay for your compressor to restart after it has turned off. Emergency Heat Mode (Heat pump systems only) In this mode, heat pump system will be bypassed and auxiliary heat becomes first stage heat. Note: Enter Emergency Heat from non-program heat mode by pressing the button for 10 seconds. Note: Exit Emergency Heat by pressing the button for 10 seconds. Cool and Heat Mode The thermostat controls the heating and cooling systems, automatically changing over from one to the other as required. Operating modes continued on Page 26 25

Operating Mode (continued) Program Mode In this mode, the program function is on (PROG displays), and the thermostat will automatically be controlled by the set program. Program mode can function with Heat mode, Cool mode, Cool and Heat mode, or OFF mode (for Programmable fan option only). Press the button to enter and exit program mode. Program Mode Hold The program schedule can be overridden by changing the set temperature ( or ). After 2 hours, the program schedule will automatically be resumed. To return to the program schedule manually, press the button twice. Setting the Time and Day of the Week The time and day of the week must be set for your program schedule to operate correctly. 1. Verify thermostat is in non-programmable mode (use the button to exit prog mode). 2. Press and release button until OFF mode displays. 3. Press the button in for 6 seconds. 4. Press the or button to adjust the time. 5. Press the button while the time is displayed. The display shows the day. currently set on the thermostat (1=Monday, 2=Tuesday, etc). 6. Press the or button to set the correct day of the week that today is. Note: Press the button in for 5 seconds to lock values into memory or press the button once to enter programming. 26

Program Overview Programming The SC3801 programmable thermostat has four periods (MORN, DAY, EVE, NITE) that are customizable for each day of the week. Each period will have a start time, heat temperature, cool temperature, and programmable fan. The SC3801 monitors the day and time, while maintaining the specific conditions you have chosen for each period in your program. 1. Verify thermostat is in non-programmable mode. (use the button to exit prog mode). 2. Press and release the button until OFF mode displays. 3. Press the button for 6 seconds. 4. Press the button twice. Day is displayed (1-7) 5. Press the or button to change the day you want to program (1=Monday, 2=Tuesday, etc). 6. Press the button to advance to the next screen. Note: You can always press the button to return to the previous screen. Period is displayed (MORN, DAY, EVE, NITE) 7. Press the or button to change period of day. 8. Press the button to advance to the next screen. 27

Programming (continued) Set time is displayed 9. Press the or button to change set time. 10. Press the button to advance to the next screen. Note: Transitions required after 11:59 PM must be programmed in the next day s MORN period. Heat temperature is displayed (50 F to 90 F) 11. Press the or button to adjust heat set temperature. 12. Press the button to advance to the next screen. Cool temperature is displayed (45 F to 85 F) 13. Press the or button to adjust cool set temperature. 14. Press the button to advance to the next screen. Programmable fan is displayed 15. Press the or button to turn ON/OFF continuous indoor fan for that period. 16. Press the button to advance to the next screen. Repeat steps 1-16 to program each day of the week individually or use the Simpleset feature (see Page 29) to program every day the same as Monday. Press the Press the Press the button for 5 seconds to exit programming and return to the OFF mode. button to select the correct operating mode. button to enter and exit program mode. PROG displays when in program mode. 28

Simpleset Programming Simpleset programming is a convenient method of programming the thermostat. Once the entire Monday (Day 1) schedule is set, Simpleset programming will copy the Monday schedule to every day of the week. After the complete Monday schedule is set (see Programming on Page 27), you are at the Day 2 screen: 1. Press the button once. Day 1 screen displays. 2. Press the button for 2 seconds. The days of the week will count down from 7 to 1 and this will lock the. settings into memory Once the schedule is locked in, you can go through each day and make. any changes you require; This feature speeds up the programming of. the standard weekday/weekend schedule 3. Press button for 5 seconds to exit Program mode and return to the OFF mode. The SC3801 has a button lockout feature so the mode cannot be changed and the temperature adjustment is limited. Select the appropriate lockout from Configuration Mode Settings, Step 16, Page 22 of this guide. To activate the LOC feature: Lockout Feature 1. Press the button and hold it in. 2. Also press button and keep both depressed for 10 seconds. 3. LOC will display and the Lockout Function will be enabled. To deactivate the LOC feature, repeat steps 1 & 2 above (in this section). 29

Factory Preprogramming The SC3801 comes preprogrammed with the following schedule: MONDAY thru SUNDAY MORN 6:00 AM DAY 8:00 AM EVE 6:00 PM NITE 10:00 PM HEAT 70 F HEAT 62 F HEAT 70 F HEAT 62 F COOL 78 F COOL 85 F COOL 78 F COOL 82 F FAN* ON/OFF FAN* ON/OFF FAN* ON/OFF FAN* ON/OFF * = Programmable fan option Personal Program Schedule Use the following personal program schedule to record your settings: MONDAY 1 MORN DAY EVE NITE HEAT HEAT HEAT HEAT COOL COOL COOL COOL FAN* ON/OFF FAN* ON/OFF FAN* ON/OFF FAN* ON/OFF * = Programmable fan option 30

Personal Program Schedule (continued) TUESDAY 2 MORN DAY EVE NITE HEAT HEAT HEAT HEAT COOL COOL COOL COOL FAN* ON/OFF FAN* ON/OFF FAN* ON/OFF FAN* ON/OFF WEDNESDAY 3 MORN DAY EVE NITE HEAT HEAT HEAT HEAT COOL COOL COOL COOL FAN* ON/OFF FAN* ON/OFF FAN* ON/OFF FAN* ON/OFF THURSDAY 4 MORN DAY EVE NITE HEAT HEAT HEAT HEAT COOL COOL COOL COOL FAN* ON/OFF FAN* ON/OFF FAN* ON/OFF FAN* ON/OFF 31

Personal Program Schedule (continued) FRIDAY 5 MORN DAY EVE NITE HEAT HEAT HEAT HEAT COOL COOL COOL COOL FAN* ON/OFF FAN* ON/OFF FAN* ON/OFF FAN* ON/OFF SATURDAY 6 MORN DAY EVE NITE HEAT HEAT HEAT HEAT COOL COOL COOL COOL FAN* ON/OFF FAN* ON/OFF FAN* ON/OFF FAN* ON/OFF SUNDAY 7 MORN DAY EVE NITE HEAT HEAT HEAT HEAT COOL COOL COOL COOL FAN* ON/OFF FAN* ON/OFF FAN* ON/OFF FAN* ON/OFF 32

No display Symptom System fan does not come on properly Program schedule activates at the wrong time Thermostat turns on and off too frequently Thermostat does not follow program Fan runs continuously Room temperature is not correct LOC displays when any button is pressed or thermostat buttons are inoperative Remedy Check for 24 VAC at thermostat; display is blank when 24 VAC is not present Verify wiring is correct, check electric heat setup in configuration (see Configuration Mode, Step 3, Page 19) Check time (AM/PM) set on thermostat (see Setting the Time, Page 26) Adjust temperature differential (see Differential, Steps 5 and 6, Page 20) Verify it is operating in Program mode (PROG displays); check time (AM/PM) Check fan On/Auto switch; check programmable fan setting in program; check fan settings in configuration (see Configuration Mode, Page 19) Verify wall hole is plugged with putty or insulation; check wiring and location for remote sensor if used Thermostat has the button lockout function activated (see Lockout Feature, Page 29) EH shows on display Thermostat is in Emergency Heat Mode (see Operating Modes, Page 25) Very limited setpoint adjustment Problem not listed above Troubleshooting Thermostat has the button lockout function activated (see Lockout Feature, Page 29) Check configuration mode settings 17 and 18, Page 22 Press Reset button once* * Reset Button Function Time, day and mode changed to last saved settings (saved after power loss or when exiting program setup), configuration and program settings are unchanged. 33

ONE-YEAR LIMITED WARRANTY The Seller warrants its products against defects in material or workmanship for a period of one (1) year from the date of manufacture. The liability of the Seller is limited, at its option, to repair, replace or issue a non-case credit for the purchase prices of the goods which are provided to be defective. The warranty and remedies set forth herein do not apply to any goods or parts thereof which have been subjected to misuse including any use or application in violation of the Seller s instructions, neglect, tampering, improper storage, incorrect installation or servicing not performed by the Seller. In order to permit the Seller to properly administer the warranty, the Buyer shall: 1) Notify the Seller promptly of any claim, submitting date code information or any other pertinent data as requested by the Seller. 2) Permit the Seller to inspect and test the product claimed to be defective. Items claimed to be defective and are determined by Seller to be non-defective are subject to a $30.00 per hour inspection fee. This warranty constitutes the Seller s sole liability hereunder and is in lieu of any other warranty expressed, implied or statutory. Unless otherwise stated in writing, Seller makes no warranty that the goods depicted or described herein are fit for any particular purpose. Patent No. 424,953 6333 Daedalus Drive, Cicero, NY 13039 (Toll Free) 800-365-5525 (Phone) 315-233-5266 (Fax) 315-233-5276 www.icmcontrols.com LIA216