M E M O R A N D U M. NFPA Technical Committee on Fire Safety and Emergency Symbols. NFPA 170 Second Draft TC FINAL Ballot Results (F2014)

Similar documents
Symbols for Control Panels

MEMORANDUM. Technical Committee on Protected Premises Fire Alarm and Signaling Systems

First Draft Meeting (F2017) Agenda Friday, March 11 th, :30 AM 4:00 PM ET

MEMORANDUM. Technical Committee on Fundamentals of Fire Alarm and Signaling Systems

MEMORANDUM. Technical Committee on Notification Appliances for Fire Alarm and Signaling Systems

MEMORANDUM. NFPA Technical Committee on Solvent Extraction Plants. NFPA 36 First Draft TC FINAL Ballot Results (F2016)

26 of 128 9/23/2014 9:25 AM

MEMORANDUM. Technical Committee on Emergency Power Supplies. NFPA 111 First Draft Technical Committee FINAL Ballot Results (A2018)

Unified Fire Authority - Fire Prevention Bureau


National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

M E M O R A N D U M. Technical Committee on Supervising Station Fire Alarm and Signaling Systems

MEMORANDUM. Technical Committee on Board and Care Facilities. NFPA 101 Second Draft Technical Committee FINAL Ballot Results (A2017)

Second Revision No. 2-NFPA [ Section No ]

M E M O R A N D U M. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

Correlating Committee on Automatic Sprinkler Systems

MEMORANDUM. Technical Committee on Initiating Devices for Fire Alarm and Signaling Systems

Committee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM

Second Revision No. 104-NFPA [ Section No ] Submitter Information Verification. Committee Statement

M EM O RA N D UM. NFPA 652 First Draft Correlating Committee FINAL Ballot Results (A2018)

Alarm. A warning of danger. An indication of the existence of a condition that requires immediate action. (SIG-FUN)


First Revision No. 49-NFPA 17A-2015 [ Detail ] Submitter Information Verification. Committee Statement 7/30/2015 1:35 PM

MEMORANDUM. NFPA 51 First Draft Technical Committee FINAL Ballot Results (A2017 Cycle)

Second Revision No. 1-NFPA [ Section No. 2.2 ] Submitter Information Verification. Committee Statement

M E M O R A N D U M. NFPA 1911 Second Draft Technical Committee FINAL Ballot Results (F2016 Cycle)

Fire Alarm System Fundamentals

M E M O R A N D U M. NFPA Technical Committee on Water Additives for Fire Control and Vapor Mitigation

First Revision No. 158-NFPA [ Global Input ] Submitter Information Verification. Committee Statement

National Fire Protection Association M E M O R A N D U M. NFPA Technical Committee on Construction and Demolition

Second Revision No. 1-NFPA 17A-2016 [ Section No ] Submitter Information Verification. Committee Statement. 1 of 14 6/22/2016 3:15 PM

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

M E M O R A N D U M. NFPA Technical Committee on Telecommunications. Elena Carroll, Administrator, Technical Projects. Date: July 8, 2014

9/20/2016 2:53 PM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification

12/21/2015 National Fire Protection Association Report

First Revision No. 82-NFPA [ Section No ] Submitter Information Verification. Committee Statement. 2 of /21/2013 1:03 PM

MEMORANDUM. NFPA Technical Committee on Fundamentals of Fire Alarm and Signaling Systems (SIG- FUN)

2. HVAC and smoke control systems; fire, smoke, and combination fire/smoke dampers. 5. Central control and monitoring system.

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

SECTION : FIRE ALARM & DETECTION SYSTEMS

Lake County / Multi-Department Storage Facility / Project / December 12, 2016 SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Second Revision No. 11-NFPA [ Section No. 2.4 ] Submitter Information Verification. Committee Statement

M E M O R A N D U M. NFPA Technical Committee on Fire Department Apparatus. Yvonne Smith, Project Administrator. Date: June 4, 2014

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association M E M O R A N D U M. Technical Committee on Testing and Maintenance of Fire Alarm and Signaling Systems

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing.

Second Revision No. 1 NFPA [ Chapter 2 ]

M E M O R A N D U M. NFPA Technical Committee on Wood and Cellulosic Materials Processing

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

MEMORANDUM. Technical Committee on Alternative Approaches to Life Safety. NFPA 101A First Draft Technical Committee FINAL Ballot Results (A2018)

First Revision No. 3-NFPA 51B-2016 [ New Section after 1.5 ] Submitter Information Verification. Committee Statement 11/18/2016 2:25 PM

INSPECTION AND TESTING FORM

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement 10/20/ :03 AM

First Revision No. 339-NFPA [ Section No. 2.2 ]

M E M O R A N D U M. NFPA Technical Committee on Alternative Approaches to Life Safety. SUBJECT: NFPA 101A ROP TC Letter Ballot (A2012 Cycle)

Committee Input No. 60-NFPA [ Sections , ]

M E M O R A N D U M. Technical Committee on Fire Fighter Professional Qualifications

PROTECTED PROPERTY. City: State: Zip Code: ALARM SERVICE COMPANY. City: State: Zip Code: COMMENTS AND CLARIFICATIONS ALARM SYSTEM DESCRIPTION

Agenda Technical Committee on Initiating Devices for Fire Alarm and Signaling Systems June 24-25, 2013 Saint Louis, MO

MEMORANDUM. NFPA Technical Committee on Hazard and Risk of Contents and Furnishings. NFPA 556 First Draft TC FINAL Ballot Results (A2015)

First Revision No. 88-NFPA [ Section No. 2.4 ] Submitter Information Verification. Committee Statement. 3 of /21/2013 1:03 PM

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

Circulation Report for SIG-TMS Comments Document # 72

Public Comment No. 2-NFPA [ Section No ]

M E M O R A N D U M. NFPA 1 First Draft Technical Committee FINAL Ballot Results (A2017)

SUBJECT: NFPA 302 Second Draft TC Final Ballot Results (A2014)


National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

9/23/ :20 AM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification

MEMORANDUM. Technical Committee on Mercantile and Business Occupancies. NFPA 101 Second Draft Technical Committee FINAL Ballot Results (A2017)

SAF-BCF SECOND REVISIONS WITH STATEMENTS

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

SECTION ADDRESSABLE FIRE ALARM SYSTEM

NFPA Siemens Industry, Inc. All rights reserved. usa.siemens.com/infrastructure-cities

M E M O R A N D U M. NFPA Technical Committee on Water Spray Fixed Systems

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

First Revision No. 6-NFPA [ Section No. 2.2 ]

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

Standard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics.

First Revision No. 1-NFPA [ Chapter 2 ]

National Fire Protection Association

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association M E M O R A N D U M. NFPA Technical Committee on Residential Sprinkler Systems

MEMORANDUM. Technical Committee on Fundamentals of Combustible Dusts. NFPA 652 First Draft Technical Committee FINAL Ballot Results (A2018)

M E M O R A N D U M. NFPA Technical Committee on Water Additives for Fire Control and Vapor Mitigation

Hinesville First United Methodist Church SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 4/15/ :08 AM

TECHNICAL COMMITTEE ON FIRE CODE

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

M E M O R A N D U M. NFPA 76 Second Draft TC FINAL Ballot Results (F2015 Cycle)

First Revision No. 2-NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of 11 1/18/2016 5:43 PM

FIRE & LIFE SAFTEY STANDARD

NFPA 72 Code Changes vs 2013

16721 FIRE ALARM AND DETECTION SYSTEMS

MEMORANDUM. SUBJ: NFPA 72 Proposed TIA No FINAL CC BALLOT RESULTS

Transcription:

National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M To: From: NFPA Technical Committee on Fire Safety and Emergency Symbols Colleen Kelly, Administrator, Technical Projects Date: May 27, 2014 Subject: NFPA 170 Second Draft TC FINAL Ballot Results (F2014) According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot. 10 Members Eligible to Vote 1 Not Returned (Cox) 9 Members voted Affirmative on All Revisions 0 Members voted Negative on one or more Revision 0 Members voted to Abstain on one or more Revision The attached report shows the number of affirmative, negative, and abstaining votes as well as the explanation of the vote for each second revision. There are two criteria necessary for each second revision to pass ballot: (1) simple majority and (2) Affirmative 2 / 3 vote. The mock examples below show how the calculations are determined. (1) Example for Simple Majority: Assuming there are 20 vote eligible committee members, 11 affirmative votes are required to pass ballot. (Sample calculation: 20 members eligible to vote 2 = 10 + 1 = 11) (2) Example for Affirmative 2 / 3 : Assuming there are 20 vote eligible committee members and 1 member did not return their ballot and 2 members abstained, the number of affirmative votes required would be 12. (Sample calculation: 20 members eligible to vote 1 not returned 2 abstentions = 17 x 0.66 = 11.22 = 12) As always please feel free to contact me if you have any question

of 33 5/27/2014 12:28 PM Second Revision No. 1-NFPA 170-2014 [ Global Comment ] Throughout the document add "or photoluminescent" whenever self-luminous appears except for chapter 3 definitions. Submitter Information Verification Submitter Full Name: [ Not Specified ] Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Wed Jan 22 16:36:36 EST 2014 Committee Statement Committee Statement: The criteria for self-luminous also applies to photoluminescent. Response Message: Ballot Results This item has passed ballot 10 Eligible Voters 1 Not Returned 9 Affirmative All 0 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Cox, David C. Affirmative All Bailey, Scott Brown, Phillip A. Dhillon, Lily Heebner, Thomas E. Johnson, David F. Mundy, Jr., James M. Schiffer, Brad Willms, Christopher Wood, Thomas R.

of 33 5/27/2014 12:28 PM Second Revision No. 3-NFPA 170-2014 [ Global Input ] Replace the wisp of smoke with the letter "S" in Table 8.3, 8.5, 8.6 and Figure A.6.1.2.4(b). Submitter Information Verification Submitter Full Name: [ Not Specified ] Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Wed Jan 22 16:52:07 EST 2014 Committee Statement Committee Statement: Due to the evolution of design measures the smoke wisp is difficult to create. Response Message: Public Comment No. 5-NFPA 170-2013 [Global Input] Public Comment No. 6-NFPA 170-2013 [Global Input] Ballot Results This item has passed ballot 10 Eligible Voters 1 Not Returned 9 Affirmative All 0 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Cox, David C. Affirmative All Bailey, Scott Brown, Phillip A. Dhillon, Lily Heebner, Thomas E. Johnson, David F. Mundy, Jr., James M. Schiffer, Brad Willms, Christopher Wood, Thomas R.

of 33 5/27/2014 12:28 PM Second Revision No. 7-NFPA 170-2014 [ Section No. 2.4 ] 2.4 References for Extracts in Mandatory Sections. NFPA 10, Standard for Portable Fire Extinguishers, 2013 edition. NFPA 101, Life Safety Code, 2015 edition. Submitter Information Verification Submitter Full Name: Ellen Cosgrove Organization: NFPA Street Address: City: State: Zip: Submittal Date: Mon Feb 03 14:03:48 EST 2014 Committee Statement Committee Statement: Added NFPA 101 because it's being extracted. Response Message: Ballot Results This item has passed ballot 10 Eligible Voters 1 Not Returned 9 Affirmative All 0 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Cox, David C. Affirmative All Bailey, Scott Brown, Phillip A. Dhillon, Lily Heebner, Thomas E. Johnson, David F. Mundy, Jr., James M. Schiffer, Brad Willms, Christopher Wood, Thomas R.

of 33 5/27/2014 12:28 PM Second Revision No. 5-NFPA 170-2014 [ New Section after 3.3.1 ] 3.3.1 Photoluminescent. Having the ability to store incident electromagnetic radiation typically from ambient light sources, and release it in the form of visible light. [ 101, 2015] Submitter Information Verification Submitter Full Name: Chad Duffy Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Tue Jan 28 14:53:30 EST 2014 Committee Statement Committee Statement: Extract definition from 101 as shown in the glossary of terms for "Photoluminescent". Response Message: Public Comment No. 1-NFPA 170-2013 [Section No. 3.3.3] Ballot Results This item has passed ballot 10 Eligible Voters 1 Not Returned 9 Affirmative All 0 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Cox, David C. Affirmative All Bailey, Scott Brown, Phillip A. Dhillon, Lily Heebner, Thomas E. Johnson, David F. Mundy, Jr., James M. Schiffer, Brad Willms, Christopher Wood, Thomas R.

Second Revision No. 4-NFPA 170-2014 [ Section No. 6.3.3 ] 6.3.3* Symbols for Walls and Parapets. Symbols for walls and parapets shall be as given in Table 6.3.3. Table 6.3.3 Symbols for Walls and Parapets Symbol Wall basic shape Smoke barrier wall 1 2-hour fire barrier wall 1 2-hour fire/smoke barrier wall 3 4-hour fire barrier wall 3 4-hour fire/smoke barrier wall 1-hour fire barrier wall 1-hour fire/smoke barrier wall 2-hour fire barrier wall 2-hour fire wall 2-hour fire/smoke barrier wall 3-hour fire barrier wall 3-hour fire wall 3-hour fire/smoke barrier wall 4-hour fire barrier wall 4-hour fire wall 4-hour fire/smoke barrier wall Parapet One cross for each 150 mm (6 in.) parapet that extends above roof (Shown shown is plan view of symbol).) Supplemental Information File Name Table_6.3.3_Revisions_SR-4_.pdf Submitter Information Verification Submitter Full Name: [ Not Specified ] Organization: [ Not Specified ] Street Address: City: State: Zip: of 33 5/27/2014 12:28 PM

of 33 5/27/2014 12:28 PM Submittal Date: Wed Jan 22 17:20:06 EST 2014 Committee Statement Committee Statement: Response Message: Add symbols back to table 6.3.3 for "Fire Barriers" as shown in first revision report. Clarify text as follows: "S" on the symbol represents "Fire/Smoke Barrier", "F" on the symbol represents "Fire Wall", and no letter on the symbol represents "Fire Barrier". See attached mark-up. Ballot Results This item has passed ballot 10 Eligible Voters 1 Not Returned 9 Affirmative All 0 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Cox, David C. Affirmative All Bailey, Scott Brown, Phillip A. Dhillon, Lily Heebner, Thomas E. Johnson, David F. Mundy, Jr., James M. Schiffer, Brad Willms, Christopher Wood, Thomas R.

of 33 5/27/2014 12:28 PM Second Revision No. 9-NFPA 170-2014 [ Section No. 8.2 ]

of 33 5/27/2014 12:28 PM 8.2 Symbols for Control Panels.

of 33 5/27/2014 12:28 PM Symbols for control panels shall be as given in Table 8.2. Table 8.2 Symbols for Control Units (Panels) Symbol Basic shape Amplifier rack Area of refuge emergency communication system master unit Area of refuge emergency communication system remote unit Autonomous control unit Battery cabinet Cathode ray tube Control panel for heating (H), ventilation (V),, air conditioning (AC), exhaust (E), stairwell pressurization (P) Dedicated function fire alarm control unit Digital alarm communicator receiver Digital alarm communicator transmitter Elevator status/recall Emergency communications control unit Fire alarm annunciator Fire alarm communicator Fire alarm control panel Fire alarm control unit (dedicated) Fire alarm terminal cabinet Fire alarm transponder n = transponder number Fire fighter interface Fire suppression control panel xx denotes suppression type Fire suppression control unit xx denotes suppression type Graphic annunciator panel LCD annunciator/display Master fire alarm control unit Notification circuit power booster, extender panel n = unit number

0 of 33 5/27/2014 12:28 PM Symbol Power panel Pre-action system/control unit Printer Protected premises control unit (local) Purge panel Relay panel Releasing service fire alarm control unit Remote voice evacuation microphone Remotely located evacuation amplifier cabiner Sprinkler alarm panel Uninterruptible power supply Voice evacuation control unit Wireless control unit Fire Suppression/Releasing Service Control Unit Types: Aerosol Carbon dioxide Clean agent Deluge fire sprinkler Dry chemical Fire alarm control interface Fire pump controller Foam Halon Mass notification system interface Operating control unit Water mist

1 of 33 5/27/2014 12:28 PM Symbol Wet chemical Supplemental Information File Name NFPA_170_2014F_Table_8.2.pdf G170-802.jpg G170-803.jpg G170-804.jpg 8.2_39 RSFACU_A symbol 8.2_44 MNS symbol 8.2_49 OCU symbol Submitter Information Verification Submitter Full Name: Audrey Goldstein Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Wed Apr 02 14:03:05 EDT 2014 Committee Statement Committee Statement: Response Message: The symbols have been revised to align the tables with what is being practiced in the industry today. Ballot Results This item has passed ballot 10 Eligible Voters 1 Not Returned 9 Affirmative All 0 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Cox, David C. Affirmative All Bailey, Scott Brown, Phillip A. Dhillon, Lily Heebner, Thomas E. Johnson, David F. Mundy, Jr., James M. Schiffer, Brad Willms, Christopher

2 of 33 5/27/2014 12:28 PM Wood, Thomas R.

3 of 33 5/27/2014 12:28 PM Second Revision No. 10-NFPA 170-2014 [ Section No. 8.3 ] Global SR-3 Hide Deleted

4 of 33 5/27/2014 12:28 PM 8.3* Symbols for Fire Alarms, Detection, and Related Equipment Signal Initiating Devices and Activation Switches. Global SR-3 Hide Deleted

5 of 33 5/27/2014 12:28 PM Symbols for signal initiating devices and activation switches shall be as given in Table 8.3. Table 8.3 Symbols for Signal Initiating Devices and Activation Switches Symbol Abort Switch Types: Abort switch basic shape Abort switch Aerosol release abort station Carbon dioxide Clean agent Deluge fire sprinkler Dry chemical Foam Halon Manual releasing station Preaction Water mist Wet chemical Addressable Modules: Addressable input monitor module Addressable input/output module; # denotes number of inputs and outputs Addressable output control module

6 of 33 5/27/2014 12:28 PM Symbol Automatic Detection Type: Isolation module Automatic detection and supervisory devices basic shape Flame Detection Types: Flame detector basic shape XX = detection type Combination ultraviolet/infrared Infrared detector Ultraviolet detector Visible radiation detector Gas Detection Types: Gas detector/sensor basic shape XX = gas type Carbon dioxide detector Carbon monoxide detector Hydrogen chloride detector Methane detector Heat Detection Types: Heat detector/sensor XX = type basic shape Combination rate of rise/fixed temperature Fixed temperature Heat detector line type

7 of 33 5/27/2014 12:28 PM Symbol Heat detector/sensor (thermal detection) orientation not to be changed Rate compensation Rate of rise only Interface and Supervisory Devices: End of line device capacitor End of line device diode End of line device relay End of line device resistor Flow detector/switch High temperature switch Level detector/switch Low temperature switch Main/Reserve Maintenance/Disconnect switch Non-addressable output relay Pressure detector/switch Solenoid valve Surge suppressor Temperature supervisory switch Transfer switch automatic with handle Transfer switch manual with handle Valve supervisory switch

8 of 33 5/27/2014 12:28 PM Symbol Valve with integral supervisory switch Manual Fire Alarm Box Types: Water detector Manual station basic shape Aerosol Carbon dioxide Clean agent Deluge fire sprinkler Drill key Dry chemical Fire alarm master box Foam Halon Preaction Pull station/fire alarm box Water mist Smoke Detection/Sensor Types: Wet chemical Smoke detector/sensor basic shape orientation not to be changed Air sampling In duct

9 of 33 5/27/2014 12:28 PM Symbol Ionization Photoelectric Relay base Single station Smoke/heat detector/carbon monoxide detector Smoke/heat detector/sensor combination Smoke alarm (single station) Smoke detector/sensor beam receiver Smoke detector/sensor beam transmitter Smoke detector/sensor XX = type

0 of 33 5/27/2014 12:28 PM Symbol Smoke detector/sensor for duct Sounder base Supplemental Information File Name NFPA_170_2014F_Table_8.3.pdf G170-805.jpg G170-806.jpg G170-807.jpg G170-808.jpg G170-386r1.jpg G170-809.jpg G170-449r1.jpg G170-810.jpg G170-731r2.jpg 8.3_3 AR symbol 8.3_16 IM symbol 8.3_43 MR symbol 8.3_44 MD symbol 8.3_45 RL symbol revised 8.3_48 SS symbol 8.3_50 ATS symbol revised 8.3_56 A symbol 8.3_77 SS (hex) symbol revised Submitter Information Verification Submitter Full Name: Audrey Goldstein Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Wed Apr 02 14:21:44 EDT 2014 Committee Statement Committee Statement: Response Message: The symbols have been revised to align the tables with what is being practiced in the industry today. Ballot Results This item has passed ballot

1 of 33 5/27/2014 12:28 PM 10 Eligible Voters 1 Not Returned 9 Affirmative All 0 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Cox, David C. Affirmative All Bailey, Scott Brown, Phillip A. Dhillon, Lily Heebner, Thomas E. Johnson, David F. Mundy, Jr., James M. Schiffer, Brad Willms, Christopher Wood, Thomas R.

Second Revision No. 11-NFPA 170-2014 [ Section No. 8.4.1 ] 8.4.1 Notification appliance subscripts shall be applied to symbols as required for clarification (see Table 8.4.1). Table 8.4.1 Notification Appliance Subscripts Subscript Meaning C H L MNS P RI SL nw WP WG Ceiling mount High audible setting Low audible setting Mass notification system Pendent Remote indicator Signal light Wattage setting (n = speaker tap) Weatherproof Wire guard Supplemental Information File Name NFPA_170_2014F_Table_8.4.1_-_SR_11.pdf Submitter Information Verification Submitter Full Name: Audrey Goldstein Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Wed Apr 02 14:32:47 EDT 2014 Committee Statement Committee Statement: Clarified the meaning of the subscript MNS Mass Notification System. Response Message: Ballot Results This item has passed ballot 10 Eligible Voters 1 Not Returned 9 Affirmative All 0 Affirmative with Comments 0 Negative with Comments 0 Abstention 2 of 33 5/27/2014 12:28 PM

Not Returned Cox, David C. Affirmative All Bailey, Scott Brown, Phillip A. Dhillon, Lily Heebner, Thomas E. Johnson, David F. Mundy, Jr., James M. Schiffer, Brad Willms, Christopher Wood, Thomas R. 3 of 33 5/27/2014 12:28 PM

4 of 33 5/27/2014 12:28 PM Second Revision No. 12-NFPA 170-2014 [ Section No. 8.4.2 ]

5 of 33 5/27/2014 12:28 PM 8.4.2 Notification Appliances.

6 of 33 5/27/2014 12:28 PM Symbols for notification appliances shall be as given in Table 8.4.2. Table 8.4.2 Symbols for Notification Appliances Symbol Audible appliance basic shape Bell single stroke Bell trouble Bell vibrating Ceiling mount indicator Chime Chime electronic Combination horn/visible CD = candela rating/setting Combination speaker/visible W = wattage CD = candela rating/setting Gong

7 of 33 5/27/2014 12:28 PM Symbol Horn only Mini-horn Remote alarm indicating and test switch Remote indicator Rotating beacon Speaker only, ceiling mount denote wattage tap Speaker only, wall mount denote wattage tap Visible only (strobe) ceiling mount CD = candela rating/setting Visible only (strobe) wall mount CD = candela rating/setting Supplemental Information File Name NFPA_170_2014F_Table_8.4.2_-_SR_12.pdf G170-755r1.jpg G170-756r1.jpg G170-754r1.jpg G170-758r1.jpg G170-751r1.jpg G170-757r1.jpg G170-749r1.jpg G170-750r1.jpg 8.4.2_2 F_SS symbol revised 8.4.2_3 F_T symbol revised 8.4.2_4 F_V symbol revised 8.4.2_6 F_C symbol revised 8.4.2_7 F_C (triangle) symbol revised 8.4.2_10 F_G symbol revised 8.4.2_11 F_H symbol revised 8.2.4_12 F_M symbol revised

8 of 33 5/27/2014 12:28 PM Submitter Information Verification Submitter Full Name: Audrey Goldstein Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Wed Apr 02 14:34:51 EDT 2014 Committee Statement Committee Statement: Response Message: The symbols have been revised to align the tables with what is being practiced in the industry today. Ballot Results This item has passed ballot 10 Eligible Voters 1 Not Returned 9 Affirmative All 0 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Cox, David C. Affirmative All Bailey, Scott Brown, Phillip A. Dhillon, Lily Heebner, Thomas E. Johnson, David F. Mundy, Jr., James M. Schiffer, Brad Willms, Christopher Wood, Thomas R.

9 of 33 5/27/2014 12:28 PM Second Revision No. 13-NFPA 170-2014 [ Section No. 8.5 ] 8.5 Related Equipment. Symbols for related equipment shall be as given in Table 8.5. Table 8.5 Symbols for Related Equipment Global SR-3 Hide Deleted Global SR-3 Hide Deleted Symbol Air sampling detector piping Door closer Door holder End of line resistor Fire service or emergency phone station accessible Fire service or emergency phone station basic shape Fire service or emergency phone station handset Fire service or emergency phone station jack Floor Warden Station Integrated smoke sensor and door closer Isolator module (Style 6 or 7 fault protection) Junction box Mass notification system Sync adapter module (strobe synchronization) Watchman's tour station Supplemental Information File Name

0 of 33 5/27/2014 12:28 PM NFPA_170_2014F_Table_8.5_-_SR_13.pdf Submitter Information Verification Submitter Full Name: Audrey Goldstein Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Wed Apr 02 14:36:44 EDT 2014 Committee Statement Committee Statement: The sybol for ISO and MNS have been removed as they are located in other tables. Response Message: Ballot Results This item has passed ballot 10 Eligible Voters 1 Not Returned 9 Affirmative All 0 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Cox, David C. Affirmative All Bailey, Scott Brown, Phillip A. Dhillon, Lily Heebner, Thomas E. Johnson, David F. Mundy, Jr., James M. Schiffer, Brad Willms, Christopher Wood, Thomas R.

1 of 33 5/27/2014 12:28 PM Second Revision No. 8-NFPA 170-2014 [ Section No. A.6.1.2.4 ] A.6.1.2.4 See Figure A.6.1.2.4(a) and Figure A.6.1.2.4(b) for examples of symbol orientation. Figure A.6.1.2.4(a) Symbol Orientation Example 1. Global SR-3 Hide Deleted Global SR-3 Hide Deleted Figure A.6.1.2.4(b) Symbol Orientation Example 2. Supplemental Information File Name NFPA_170_2014F_Figure_A.6.1.2.4_b_.pdf G170-33r2.jpg Figure A.6.1.2.4(b) revised Submitter Information Verification Submitter Full Name: Audrey Goldstein Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Wed Apr 02 13:30:00 EDT 2014

2 of 33 5/27/2014 12:28 PM Committee Statement Committee Statement: Response Message: The symbols used in annex figures need to match those used in the tables located within the body of the standard. Ballot Results This item has passed ballot 10 Eligible Voters 1 Not Returned 9 Affirmative All 0 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Cox, David C. Affirmative All Bailey, Scott Brown, Phillip A. Dhillon, Lily Heebner, Thomas E. Johnson, David F. Mundy, Jr., James M. Schiffer, Brad Willms, Christopher Wood, Thomas R.

3 of 33 5/27/2014 12:28 PM Second Revision No. 6-NFPA 170-2014 [ Section No. D.1.2.1 ] D.1.2.1 ANSI Publications. American National Standards Institute, Inc., 25 West 43rd Street, 4th floor, New York, NY 10036. ANSI A117.1, Accessible and Usable Buildings and Facilities,2003 2009. Submitter Information Verification Submitter Full Name: Chad Duffy Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Fri Jan 31 08:57:14 EST 2014 Committee Statement Committee Statement: Editorial. Response Message: Ballot Results This item has passed ballot 10 Eligible Voters 1 Not Returned 9 Affirmative All 0 Affirmative with Comments 0 Negative with Comments 0 Abstention Not Returned Cox, David C. Affirmative All Bailey, Scott Brown, Phillip A. Dhillon, Lily Heebner, Thomas E. Johnson, David F. Mundy, Jr., James M. Schiffer, Brad Willms, Christopher Wood, Thomas R.