Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

Similar documents
OPERATING AND INSTALLATION

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

YO3 - YO4 / YL4 - YO5 / YL5

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

INSTRUCTION & SERVICE MANUAL

Sounder AX03, AX05. Loud signalling device with 32 different signals. Application. Design. Signalling devices with good directivity

DB5 Intrinsically Safe Sounder Type DB-5

Explosion Proof Combination Signal db (A) / 5 Joule

WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS

MANUAL CALL POINT Intrinsically Safe (EExia), Weatherproof BG3 Range ATEX

your dust explosion protection experts

INSTRUCTION & SERVICE MANUAL

5 yr. Vitalite Rotating Warning Light. Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT

Industrial Signalling

Contents. Security. Page

Industrial Signalling. Signalling Solutions

Hazardous Area Signalling

Nexus 120 DC Sounder Nexus 120 DC Sounder with 5J Xenon Beacon Nexus 120 DC Sounder with LED Beacon

Fire Signalling. Signalling Solutions

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

FlexSQUARE Square shaped beacons

Fire Signalling. Signalling Solutions

Security - Warning Devices Audible & Visual

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

Class 1 Division 2 Hazardous Location Stack Light - Signal Traffic Light - Multiple Lamp Colors

CONTENTS NBM-06 Bell (6") Page 1

standards: standards:

Smarter Signaling AUDIBLE/VISUAL SIGNALS

Safe & hazardous area. Industrial products catalogue

The Signal Is Clear TM

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Fire Signalling. Signalling Solutions

ATEX. IECEx. culs GOST-R. VdS

Series M22 Signaling Beacons and Alarms

Half-Dome. the Design-Tower. Compact

DETCON MODEL AV1/AV2-C1D2M Hazardous Duty Class I. Div 2, Multitone Alarm Station

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

Beacons, Lights & Strobes

AUDIBLE SIGNALIZATION

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

Fire & Industrial Signalling

Conventional Audible Visual Range

Celebrating YEARS Manufacturers of Visual & Audible Signalling Devices. NEW Exd

signaling solutions from auer signal

MODEL AV2-C1D1M Hazardous Duty Class I. Div 1, Multitone Alarm Station

INSTRUCTION MANUAL (ATEX / IECEx)

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

About Tomar Audible Alarms 1000 & 1100 Power Alarm WEP Explosion Proof Power Alarm Siren

Conventional Fire Detection

Our product range. Fire: Explosion proof Hazardous location and Industrial signals

SOUNDERS Up to 113 db(a) EExd, Weatherproof DB1 Range

Xenex Conventional Fire Detection & Alarm System

Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67

AUTOMAX devices for the automation industry

SAFE AREA AUDIBLE & VISUAL SIGNALLING PRODUCTS

DETCON MODEL AV2-C1D2C Hazardous Duty Class I. Div 2, Continuous Tone Alarm Station

FIRE AND SAFETY. Manual Call Points p15-1 Magnetic Door Holders p15-3 Detection Cables p15-4 Portable Signals p15-7 Solar Powered Signals p

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

Web: LGM Products Ltd.

Pilot devices Stacklights Signal beacons

Star Headlight & Lantern Co., Inc. Company Presentation. Leader in Warning, Emergency Lighting and Signaling Products

Universal Tank Alarm Type Installation, Operation & Maintenance

SELECT-A-HORN/STROBE SERIES

POWER SUPPLIES, LOUDSPEAKERS, SIGNAL UNITS, CABINETS

INSTRUCTION MANUAL (ATEX / IECEx)

TrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions

Industrial Horn & LED Strobe Warning System - 12V DC - Weatherproof - NEMA 4X - Class 1 Beacon

Signaling Solutions for Alarm, Warning, and Indication

120W Explosion Proof Signal Light w/ Audible Alarm - C1D1 - (2) Colored LED Lamps - 55 Horn Tones

Intellia Sounder Bases and Sounder Beacon Bases

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5

SIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics

Sonos Sounder Beacon (DC)

L-Series, Emergency Communication Devices

Code Master Factory Sealed Strobe Luminaires Explosionproof, Dust-Ignitionproof

EN54-23 Beacons & Sounder Beacons

LEAKSTOPPER RANGE Multizone water leak detection systems

Global Series. Installation and Maintenance Instructions. Model G-STR Strobe Beacon. For Use in Hazardous Locations

Opal TM AV Devices. Data Sheet. Benefits

NEVER ACTIVATE THE STROBE WITH THE PCB OUT OF ITS PROTECTIVE CASE. EXTREME CARE IS ADVISED TO REMOVE THE RISK OF ELECTRIC SHOCK.

Vehicle Safety & Warning. Product Catalogue (0)

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS

Opal TM AV Devices. Data Sheet. Benefits

POINT FLASHING BEACON PFB EX LED HAZARDOUS AREA CLASS I, DIVISION 2

Dräger PointGard 2100 Detection of toxic gases and vapours

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Vibratone Horns. Models 350 and 450

NEMA-4X Series. Certified for Harsh Environment Applications

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

New Beacon Series T & U

Integrated Solutions Low Voltage Systems

Control and Annunciator Panels. Compact systems of signalling and control

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

Transcription:

Sounders Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon Pg 185 186 187 188 189 190 191

Y03 1YA030207 1YA030203 1YA030205 YL030/24 A1:2002 YL030110/230 UL464 C22.2 No. M1983 BS EN54-3:2001 incorporates amendment DIMENSIONS: (mm): Dim A 118(4.7") Dim B 102(4.0") Dim C 89(3.5") Dim D 85(3.4") Dim E 18(0.7") Two fixing holes FØ The Y03 series alarm should be mounted to a reasonably flat wall or bulkhead of suitable material using the lugs projecting from the side of the case. The lugs are bored 6mm clearance on 102mm centres. The minimum recommended length of fixing screws is 25mm. To maintain the integrity of the weather seal, the cable must be fitted using a suitable sealed gland. Line monitoring (DC only) excludes additional voltage options - 3-wire 2-stage or 2-wire single-stage, monitor via reverse polarity - 2-wire 2-stage i.e. bi-polar inputs, monitor via threshold (applied voltage<1v) End of line resistor Minimum 3K3 ohm 0.5 watts, wire-wound or metal film type. - Operating temperature: -25 to + 55 C - Operating voltage: 24Vdc, 48Vdc, 115Vac, 230Vac - Relative humidity: 90% @ 40 C - Sound output: 100dB(A) @ 1 meter - IP54 rated standard - Volume control allowing 18dB(A) adjustment - Minimum current consumption 20mA - Optional independent 2nd stage via second DIL switch - IP65 available on request - 2-stage alarm - 3-wire polarised DC (Not additional voltage option) & AC, or 2-wire bi-polar for DC only - 3-wire AC second stage control - Flame retardant ABS plastic enclosure - Stainless steel fixings - Sound selection via 5 way DIL switch Industrial Electrical Distributor 185 POWER PRODUCTS

Y04/YL4 1YA040217 UL1638, UL464 YL040/24 C22.2 NO. 205-M1983 CAN/ULC-5526-M87 BS EN54-3:2001 incorporates amendment A1:2002 The Y04/YL4 series alarm should be mounted to a reasonably flat wall or bulkhead of suitable material using the internal fixing holes. The recommended fixing screws are 4.5mm ( dia) max x 20mm long. To maintain the integrity of the weather seal, the cable must be fitted using a suitable sealed gland. Line monitoring (DC only) excludes additional voltage options - 3-wire 2-stage or 2-wire single-stage, monitor via reverse polarity - 2-wire 2-stage i.e. bi-polar inputs, monitor via threshold (applied voltage<1v) End of line resistor Minimum 3K3 ohm 0.5 watts, wire-wound or metal film type - Operating temperature: -25 to + 55 C - Operating voltage: 24Vdc, 48Vdc,115Vac, 230Vac - Additional voltage options (Sounders only): 24Vdc & 48Vdc (BT), 110Vdc (Vdc versions will produce approx. 6dB less output) - Relative humidity: 90% @ 40 C - Sound output: 106dB(A) @ 1 meter - IP54 rated standard - Volume control allowing 18dB(A) adjustment - Minimum current consumption 20mA. - Optional independent 2nd stage via second DIL switch (DC only) - IP65 available on request - 2-stage alarm - High sound output - 3-wire polarised DC (Not additional voltage option) & AC, or 2-wire bi-polar for DC only - 3-wire AC second stage control - Strobe 2.5 and 5 joule - Choice of 6 lens colours: Amber (A), Red ( R),Green (G), Opal (O), Blue (B) and Clear (C) made from flame retardant polycarbonate plastic - Red/white flame retardant ABS plastic enclosure - Flush mounting base available - Sound selection via 5 way DIL switch Industrial Electrical Distributor 186 POWER PRODUCTS

Y05/YL5 1YA050207 UL1638, UL484 1YA050203 C22.2 No. 205-M1983 CAN/ULC-5526-M87 1YA050205 BS EN54-3:2001 incorporate amendment YL050/24 A1:2002 YL050110/230 DIMENSIONS: (mm): Dim A 169(6.7") Dim B 153(6.0") Dim C 134(5.3") Dim D 8(5.0") Dim E 23(0.9") Dim F 8(0.3") Two fixing holes FØ The Y05/YL5 series alarm units should be mounted to a reasonably flat wall or bulkhead of suitable material using the lugs projecting from the side of the case. The lugs are bored 8mm on 153mm centers. The minimum recommended length of fixing screws is 25mm. To maintain the integrity of the weather seal, the cable entry must be fitted using a suitable sealed gland. Line monitoring (DC only) excludes additional voltage options - 3-wire 2-stage or 2-wire single-stage, monitor via reverse polarity - 2-wire 2-stage i.e. bi-polar inputs, monitor via threshold (applied voltage<1v) End of line resistor. Minimum 3K3 ohm 0.5 watts, wire-wound or metal film type - Operating temperature: -25 to + 55 C - Operating voltage: 24Vdc, 48Vdc, 115Vac, (Vdc versions will produce approx. 6dB less output) - Relative humidity: 90% @ 40 C - Sound output: 110dB(A) @ 1 meter - IP54 rated standard - Volume control allowing 18dB(A) adjustment - Minimum current consumption 20mA - Optional independent 2nd stage via second DIL switch (DC only) - IP65 available on request - 2-stage alarm - 3-wire polarised DC (Not additional voltage option) & AC, or 2-wire bi-polar for DC only - Choice of 6 lens colours: Amber (A), Red ( R),Green (G), Opal (O), Blue (B) and Clear (C) made from flame retardant polycarbonate plastic - High sound output - Low current consumption - Robust, reliable and simple to install - Flame retardant ABS plastic enclosure - Strobe 2.5 and 5.0 joule - Sound selection via 5 way DIL switch - Stainless steel fixings Industrial Electrical Distributor 187 POWER PRODUCTS

Y08/YL8 & Y08 SUPER/YL8 SUPER 1YA080207 UL1638, UL484 1YA080203 C22.2 No. 205-M1983 CAN/ULC-5526-M87 1YA080205 BS EN54-3:2001 incorporate amendment 1YA080217 A1:2002 1YA080213 YL08024 YL080110/230 YL08S0/024 YL08S110/230 DIMENSIONS: Dim A 269(10.6") Dim B 250(9.8") Dim C 216(8.5") Dim D 153(6.0") Dim E 24(0.9") Two fixing holes FØ The YL8/YL8 SUPER series alarm units should be mounted to a reasonably flat wall or bulkhead of suitable material using the lugs projecting from the side of the case. The lugs are bored 10mm on 250mm centres. The minimum recommended length of fixing screws is 30mm. To maintain the integrity of the weather seal, the cable entry must be fitted using a suitable sealed gland. Line monitoring (DC only) - 3-wire 2-stage or 2-wire single stage, monitor via reverse polarity - 2-wire 2-stage i.e. bi-polar inputs, monitor via threshold (applied voltage<1v) End of line resistor. Minimum 3K3 ohm 0.5 watts, wire-wound or metal film type. - Operating temperature: -25 to + 55 C - Operating voltage: 24Vdc, 48Vdc, 115Vac,230Vac +- 10% - DC second stage alarm signal is via polarised or 2-wire bi-polar connection - IP54 rated as standard - Seperate input and output terminals on Y08, optional on YL8 - Relative humidity: 90% @ 40 C - Sound output: 116dB(A) @ 1 meter - Sound output: 0dB(A) @ 1 meter (SUPER units) - Minimum current consumption 300mA - IP65 available on request - 2-stage alarm - 3-wire polarised DC and AC, or 2-wire bi-polar for DC only - Independently selectable second stage - Choice of 6 lens colours: Amber (A), Red (R), Green (G), Opal (O), Blue (B) and Clear (C) made from flame retardant polycarbonate plastic - Flame retardant ABS plastic enclosure - Strobe 2.5 and 5.0 joule - Sound selection via DIL switch - Stainless steel fixings Industrial Electrical Distributor 188 POWER PRODUCTS

Xenon Flashers V4 V4 1FL040195 1FL040422 1FL040421 ATEX DIRECTIVE -9/94/EC EN50014:1997 + Amendments 1& 2 EN50020:2002 & EN50284:1999 BASEEFA Certificate No. BAS05ATEX0075 All units are supplied seperate from the back box for ease of installation. The back box must be mounted with the two cable entries at the top or bottom. The back box should be mounted to a reasonably flat surface or to a standard wiring box using any of the internal mounting holes. A gasket is supplied, should the surface be uneven, or if the unit is to be installed in wet conditions. The installation is completed by fitting the beacon onto the back box by means of the supplied screws. Line monitoring Monitoring via reverse polarity End of line resistor minimum 3K3 ohms 0.5 watts wire-wound or metal film type Ordering information Base colours: RF=Red Flame WN=White - Operating temperature range: -25 to +40 deg C - Storage temperature range: -40 to +70 deg C - Relative humidity: 90% @ 40 deg C - IP65 Rated - Weight: DC types 0.24kg - Weight: AC types 0.22kg - Operating Voltage: Vdc or 24Vdc or 48Vdc 115Vac or 230Vac - Flash rate 1 per second - Strobe 2.5 and 5 joule - High flash intensity - 360 visibility - Reliable and simple to install - Complements audible alarm system - Flush mounting base available - Red/white flame retardant ABS plastic enclosure - Lens colours, Red (R), Amber (A), Green (G), Opal (O), Blue (B) and Clear (C) made from flame retardant polycarbonate plastic - Steady lamp version available upon request Industrial Electrical Distributor 189 POWER PRODUCTS

Explosion Proof Sounders V6 / Y06 / YL6 V4 UL STANDARDS: UL464, UL03, UL1638. Control No. 8N30 (Sounder Y06 and combined unit YL6) Control No. 13JM (Strobe only V6) UL CLASSIFICATIONS: Class I division 1 & 2, Gas group BCD. Class II division 1 & 2, Gas group EFG (Strobe only V6). CUL CANADA: CSA C22.2 No. 25-M1966, CSA C22.2 No. 30-M1986. EUROPEAN STANDARDS: EN.50014:1997 + Amendments 1 & 2 EN.50018:2000 EN50281-1-1:1998 BASEEFA 02ATEX 02X (IIB). BASEEFA 02ATEX 2222X (IIB+H2) ATEX Directive 94/9/EC. Mounting bracket provided. Holes 9mm (dia). Pitch 75mm. - IP66 NEMA 4X - Sounder: 24Vdc (Y06) 110dB @1 meter 350mA - Strobe: 24Vdc (V6) 5 Joule 220mA - Sounder/Strobe: 24Vdc (YL 6) 570mA - Operating temperature: - 35 C to + 60 C - 20 C to + 60 C - Omni directional high output sounder - 2-Stage alarm - Independently selectable 2nd stage - All units share a common explosion proof housing - Reduced installation costs - Meets universal approval - Low current consumption - Dual cable entry, cable in-cable out - LM 6 aluminium enclosure - Stainless steel fasteners - Borosilicate glass dome for strength and protection - Lens guard provided as standard - Weather proof flame retardant ABS horn - 7 Lens colours in flame retardant poly-carbonate, Clear, Opal, Yellow, Red, Amber, Blue, Green - 32 Selectable tones meeting international regulations Industrial Electrical Distributor 190 POWER PRODUCTS

CARILLON - Electronic Sounder BS EN 54-3 : 2001 incorporates amendment A1 : 2002 The Carillon alarm units should be mounted to a reasonably flat wall or bulkhead of suitable material using the internal fixing holes (mounting gasket supplied). The recommended fixing screws are dia. 4.5max x 20m long. To maintain the integrity of the weather seal, the cable must be fitted using a suitable sealed gland. - Operating temperature range: -25 to +40 deg C - Storage temperature range: -40 to +70 deg C - Relative humidity: 95% @ 40 deg C - IP65 Rated - Cable gland entry must be suitably sealed - Weight: 0.25kg - Operating Voltage: 24Vdc +/- 10% - Volume control giving 18dB(A) adjustment - Minimum current consumption 20mA - Versatile compact sounder - Low current consumption - High sound output - 2 stage alarm by 2 wire bi-polar and 3 wire polarised control - Easy installation - For 3 wire alarm system, line integrity may be monitored via reverse polarity - Sound selection via 5 way DIL switch - Red flame retardant ABS plastic enclosures Industrial Electrical Distributor 191 POWER PRODUCTS