INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR LOW PROFILE-UNIT COOLERS AND DUAL FLOW UNIT COOLER

Similar documents
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR INDUSTRIAL COOLERS

REFRIGERATION KOOL-AIR INC. DIRECT DRIVE AIR COOLED CONDENSERS AND HEAT RECOVERY UNITS

Installation, Operation, and Maintenance Information

High Profile Evaporator

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS WALK-IN COOLERS SERIES LS-LP-LA-LV

PRODUCT. TWB Two-Way Air Defrost Unit Coolers PRODUCT DATA & INSTALLATION. High Temperature (35 o F / 1.7 o C or Higher) Applications

Condensing Unit Installation and Operating Instructions

LOW PROFILE UNIT COOLER

Super-Flo Low Profile Unit Cooler

KTL Two-Way Low Profile Evaporators

LOW PROFILE UNIT COOLER

KR Electrical Defrost Unit Coolers (PN E108318_E)

Condensing Unit Installation and Operating Instructions

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

KR Series Air Defrost Unit Coolers Operating and Installation Manual

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

SM/SV-Space Master Unit Coolers (E R.0)

SECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories.

T-Series Air Conditioner T15 Model

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

Half Round Evaporators

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

ThermoSaver TM Hot Gas Defrost System

T-Series Air Conditioner T20 Model

MS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions.

LOW PROFILE UNIT COOLER. Technical Guide. Models RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost. CH-LOPTB May,

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Unit Dimension. Unit Nomenclature DEHUMIDIFIER NOMENCLATURE UNIT VOLTAGE: 2: 240/1/60 5: /3/60 9: 480/3/60 8: 600/3/60

& MAINTENANCE INSTRUCTIONS INSTALLATION, OPERATION INDUSTRIAL COOLERS & FREEZERS WALK-IN COOLERS SERIES: EK, EM, EH, EI, EB, EF

Refrigeration / Air Conditioning Systems Circuit Drawings. Student Resource Package No: NR 24

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_001_ Products that provide lasting solutions.

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_005_ Products that provide lasting solutions.

Low Profile Unit Coolers

Reach-In Unit Coolers. Technical Guide. Models TA TL C VA BBM BBL KMK RAMK BTO U. LK-RITB June

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Low Profile Unit Cooler. ECM Motors. All-Temp²B. Small to Medium Walk - Ins. Coolers & Freezer Applications. Now available with optional

T-Series Air Conditioner T53 Model

RPI Industries, Inc.

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

Low Profile Unit Coolers

SM/SV Series PRODUCT COOLERS. Technical Bulletin. Products that provide lasting solutions.

INSTALLATION and OPERATION INSTRUCTIONS

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

QUICK SHIP Walk-In Coolers & Freezers With Matching Refrigeration Systems SEE INSIDE

ThermoSaver TM Hot Gas Defrost System

COMMERCIAL AIR COOLERS AIR AND ELECTRIC DEFROST

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

TLV Low Velocity Evaporators

Low Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost.

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

Chef Base Refrigerators

Sandwich/Salad Table Under-counter Refrigerator Worktop Refrigerator

STC Series Twin Unit Coolers (E329630_A)

Center Mount Unit Coolers

KTL Two-Way Low Profile Unit Coolers

Solid Door Top Mount Reach-In Freezer

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Air Cooled Condenser Installation and Operating Instructions

RPI Industries, Inc.

Drop-In Refrigeration System

Sunny Hills. HVAC Maintenance Checklist Template. conducted for. Conducted on 31 Oct :40 PM. Prepared by Jon Nieve

INSTALLATION and OPERATING. INSTRUCTIONS for. SMZP26 Series. elf-contained Freezers

WineZone Ceiling Mount Ductless Split 15

COMMERCIAL AIR COOLERS AIR AND ELECTRIC DEFROST

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

Horizontal Bottle Cooler Installation and Operation Manual

Spare Parts Catalogue MV1006

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

COMMERCIAL AIR COOLERS AIR, ELECTRIC AND HOTGAS DEFROST

38ASB/CCARS240~600 (036~060) AIR-COOLED CONDENSING UNIT

MACH N-407 Heat Pump Air-Cooled Chiller

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions

Instructors: Contact information. Don Reynolds Doug McGee Factory Tech Support

Glass Door Merchandiser Refrigerator and Freezer

MODELS B1PA024, 030 AND 036

LH and GH/GL Series UNIT COOLERS. Technical Bulletin. Products that provide lasting solutions.

IMPORTANT PLEASE RETAIN FOR YOUR RECORDS

INSTALLATION and OPERATION INSTRUCTIONS

Evaporator Coils. Back Mount Coils ( Back Bar ) Top Mount Thin Profile Coils. High Performance Mullion Coils

Service Step by Step Trouble-Shooting Check-List

INSTRUCTIONS! DO NOT DISCARD!

LK-TSSTB July 2009 FPO HP Two Stage Condensing Units and Systems Technical Guide. with Bitzer Compressors.

ICC COOLING STORAGE UNIT ICC/ICU SYSTEM

Warm Case Troubleshooting Guide 9/18/2014

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER

Upright Chiller & Freezer Service, Installation and Care Manual

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

BTL Two-Way Low Profile Evaporators

Installation and Operation Guide For

PACKAGE AIR CONDITIONER

DT/DTX Series Unit Coolers (R0 E316013)

RPI Industries, Inc.

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

Transcription:

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR LOW PROFILE-UNIT COOLERS AND DUAL FLOW UNIT COOLER SERIES LPA SERIES LPE SERIES LPG SERIES LPH AIR DEFROST APPLICATION ELECTRIC DEFROST APPLICATION REVERSE CYCLE HOT GAS DEFROST THREE PIPES HOT GAS DEFROST SERIES MVA & BVA SERIES MVE & BVE SERIES MVG & BVG SERIES MVH & BVH AIR DEFROST APPLICATION ELECTRIC DEFROST APPLICATION REVERSE CYCLE HOT GAS DEFROST THREE PIPES HOT GAS DEFROST

WARNING: ELECTRICAL POWER MUST BE SWITCHED OFF/DISCONNECTED BEFORE STARTING ANY SERVICE WORK ON UNITS. RECEIVING & INSPECTION You have purchased one of the best units available today in the market with unique features. Congratulations and thank you for using Kool-Air. Upon receipt of shipment, please inspect the unit immediately and notify and file a claim with the transport if there is any damage. Our shipment is thoroughly inspected before it is handed over to the transport driver. Location & Installation The unit can be flush mounted against the ceiling or suspended from the ceiling depending upon the height of the room. To ensure uniform air distribution throughout the cooler a location should be chosen so that the air flow from the unit (both entering and leaving) is unrestricted. LP SERIE: To create air curtain effect, blow cold air towards the door of the cooler. This unit draws air in from the coil and discharge cold air through the fan. The horizontal throw of this unit is 20 to 30 feets. The unit must have at least an 8 inch space between the coil and the wall for air movement. MV & BV SERIE: These units draw air in from the fan and discharge cold air through the coils. The horizontal air throw of these units is 12 to 18 feet for MV series and 10 to 15 feet for BV series. Unit spacing between two units should never exceed twice the air 2

throw. These units must have at least a 36 inch space between the coil and the wall for proper air movement. For LPE, MVE & BVE models, heaters are embedded into die-formed fin slots in the face of the coil and therefore no space on the side is necessary for heater removal. (the air throw shown is for optimum conditions, it can be affected by the room height and the products loading.) Wiring All wiring must be done in accordance with national and local electrical codes. All internal wiring of the unit is done at our factory and all wiring connections terminate at the terminal block. The power supply must match with the name plate requirement. The unit cabinet must be grounded. On applications where total heater amperage exceeds 40 amps the heaters must be wired through a separate contactor, which should be located outside the cooler. Refer to the wiring diagram which is supplied with the unit for full details. Drain Line LP SERIE: The ¾ inch MPT drain connection is factory mounted on the right side of the unit when facing fans but can be easily moved to the left to accommodate field requirements. 3

MV & BV SERIE: These units has a ¾ inch MPT drain connection The drain line should be pitched sharply and exit the cooler/freezer on the shortest run as possible. The drain line should be insulated and if the cooler temperature is below 32 degrees F drain line heaters (approx. 15 watts per foot of drain line) may be required. Do not overlap the drain heaters. Provide drain trap outside the cooler/freezer in a warm area. Refrigerant Connections / Piping All refrigerant piping and connections must be installed in accordance with local and national codes. Lines should be sized in accordance with the latest A.S.H.R.A.E. Standards. Suction line trap(s) should be provided and suction line should be pitched downward toward the compressor to prevent slugging and to ensure oil return to compressor. Make sure the system is completely clean and dry. Evacuate the entire system after it has been purged and leak tested, before charging it with refrigerant. Expansion Valve All units use externally equalized TX valves and are provided with an equalizer line connection. All units liquid line/tx valve connections are sweat connections. Selection of expansion valve is very important to get peak performance from the evaporator and to have a balanced system. Check superheat reading and adjust it to obtain full evaporator performance. Refer to expansion valve manufacturer s catalogue for full details. 4

OPERATION LPA, MVA & BVA models are for Air-Defrost applications, where cooler temperature is +34 deg. F. or above. The coil can be defrosted by switching the compressor off and just running the unit cooler fans. LPE, LPG and LPH models are for freezer applications down to -20 deg. F. BVE, MVE, BVG, MVG, BVH and MVH models are for freezer applications down to 26 deg. F. LPE, MVE & BVE units are provided with high density stainless steel electric heaters, factory set sealed fan delay/defrost termination thermostat. Adjust defrost timer (maximum 45 minutes to match the application and to ensure that the coil is completely defrosted after each defrost cycle. Defrost thermostat must terminate defrost cycle and fan delay thermostat must prevent moisture from being blown from the wet coil to the freezer at the termination of the defrost cycle. Time initiated temperature terminated defrost cycle is preferred to ensure clean coils at all times. Fan motor starts from the defrost thermostat. All fan motors are permanently lubricated and thermally protected. Fan motors may cycle due to thermal protection if the coil is blocked or iced up. LPG, LPH, MVG, MVH, BVG and BVH units are defrosted by the hot gas from the compressor discharge line. See piping diagram. A crankcase pressure regulating valve is recommended on low temperature applications. Also a suction accumulator with boil out coil or suction/liquid heat exchanger is recommended to avoid liquid slugging at compressor. 5

MAINTENANCE Periodically check the unit for any vibrations and dirt accumulation. Grease and dirt should be removed from the fans, fan guards and drain pan. The drain line should be checked and all foreign material removed. The finned surface may be cleaned using a whisk or fin brush. These are relatively maintenance free units as the motors are permanently lubricated and thermally protected. REPLACEMENT PARTS Use only manufacturer approved replacement parts. When ordering parts, please make sure you have the complete model number, serial number and voltage information. 6

UNIT MOTOR FAN DRAIN PAN GUARD BOARD HARNESS LPA-18-0380-1 M0010 F0010 F0204 E-0001 E-0030 1303D01 LPA-18-0520-1 M0010 F0010 F0204 E-0001 E-0030 1303D01 LPA-18-0610-1 M0010 F0010 F0204 E-0001 E-0030 1303D01 LPA-28-0860-1 M0010 F0010 F0204 E-0001 E-0030 1303D02 LPA-28-1000-1 M0010 F0010 F0204 E-0001 E-0030 1303D03 LPA-28-1160-1 M0010 F0010 F0204 E-0001 E-0030 1303D03 LPA-38-1570-1 M0010 F0010 F0204 E-0001 E-0030 0303D04 LPA-38-1860-1 M0010 F0010 F0204 E-0001 E-0030 0303D04 LPA-48-2140-1 M0010 F0010 F0204 E-0001 E-0030 1303D05 LPA-58-2630-1 M0010 F0010 F0204 E-0001 E-0030 1303D07 LPA-58-3130-1 M0010 F0010 F0204 E-0001 E-0030 1303D07 LPA-68-3500-1 M0010 F0010 F0204 E-0001 E-0030 1303D07 FAN UNIT MOTOR FAN DRAIN PAN HEATERS GUARD BOARD HARNESS DELAY LPE-16-0480-2 M0015 F0010 F0204 E-0003 E-0030 1303D01 H-0010 E0004 LPE-16-0550-2 M0015 F0010 F0204 E-0003 E-0030 1303D01 H-0010 E0004 LPE-26-0780-2 M0015 F0010 F0204 E-0003 E-0030 1303D02 H-0015 E0004 LPE-26-0860-2 M0015 F0010 F0204 E-0003 E-0030 1303D03 H-0020 E0004 LPE-26-1080-2 M0015 F0010 F0204 E-0003 E-0030 1303D03 H-0020 E0004 LPE-36-1300-2 M0015 F0010 F0204 E-0003 E-0030 1303D04 H-0025 E0004 LPE-36-1660-2 M0015 F0010 F0204 E-0003 E-0030 1303D04 H-0025 E0004 LPE-46-2260-2 M0015 F0010 F0204 E-0003 E-0030 1303D05 H-0030 E0004 LPE-56-2890-2 M0015 F0010 F0204 E-0003 E-0030 1303D07 H-0035 E0004 LPE-66-3220-2 M0015 F0010 F0204 E-0003 E-0030 1303D07 H-0035 E0004 NOTE: THERE ARE 6 HEATERS PER UNIT 2 IN THE DRAIN PAN AND 4 IN THE COIL SLAB. UNIT MOTOR FAN DRAIN PAN GUARD BOARD HARNESS LP(G)(H)-16-0480-1 M0010 F0010 F0204 E-0001 E-0030 1303D01 LP(G)(H)-16-0550-1 M0010 F0010 F0204 E-0001 E-0030 1303D01 LP(G)(H)-26-0780-1 M0010 F0010 F0204 E-0001 E-0030 1303D02 LP(G)(H)-26-0860-1 M0010 F0010 F0204 E-0001 E-0030 1303D03 LP(G)(H)-26-1080-1 M0010 F0010 F0204 E-0001 E-0030 1303D03 LP(G)(H)-36-1300-1 M0010 F0010 F0204 E-0001 E-0030 1303D04 LP(G)(H)-36-1660-1 M0010 F0010 F0204 E-0001 E-0030 1303D04 LP(G)(H)-46-2260-1 M0010 F0010 F0204 E-0001 E-0030 1303D05 LP(G)(H)-56-2890-1 M0010 F0010 F0204 E-0001 E-0030 1303D07 LP(G)(H)-66-3220-1 M0010 F0010 F0204 E-0001 E-0030 1303D07 DRAIN FITTING KIT P0002 7

UNIT MOTOR FAN DRAIN PAN GUARD BOARD HARNESS MVA-16-0600-1 M0010 F0012 F0204 E-0001 E-0030 1505D01 MVA-26-0850-1 M0010 F0012 F0204 E-0001 E-0030 1505D02 MVA-26-1200-1 M0010 F0012 F0204 E-0001 E-0030 1505D02 MVA-26-1350-1 M0010 F0012 F0204 E-0001 E-0030 1505D03 MVA-36-1800-1 M0010 F0012 F0204 E-0001 E-0030 1505D04 MVA-36-2000-1 M0010 F0012 F0204 E-0001 E-0030 1505D04 MVA-46-2800-1 M0010 F0012 F0204 E-0001 E-0030 1505D05 MVA-56-3600-1 M0010 F0012 F0204 E-0001 E-0030 1505D13 MVA-66-4500-1 M0010 F0012 F0204 E-0001 E-0030 1505D15 FAN UNIT MOTOR FAN DRAIN PAN HEATERS GUARD BOARD HARNESS DELAY MVE-16-0600-2 M0015 F0012 F0204 E-0003 E-0030 1505D01 H-0010 E0004 MVE-26-0850-2 M0015 F0012 F0204 E-0003 E-0030 1505D02 H-0015 E0004 MVE-26-1200-2 M0015 F0012 F0204 E-0003 E-0030 1505D02 H-0015 E0004 MVE-26-1350-2 M0015 F0012 F0204 E-0003 E-0030 1505D03 H-0020 E0004 MVE-36-1800-2 M0015 F0012 F0204 E-0003 E-0030 1505D04 H-0025 E0004 MVE-36-2000-2 M0015 F0012 F0204 E-0003 E-0030 1505D04 H-0025 E0004 MVE-46-2800-2 M0015 F0012 F0204 E-0003 E-0030 1505D05 H-0030 E0004 MVE-56-3600-2 M0015 F0012 F0204 E-0003 E-0030 1505D13 H-0035 E0004 MVE-66-4500-2 M0015 F0012 F0204 E-0003 E-0030 1505D15 H-0035 E0004 NOTE: THERE ARE 6 HEATERS PER UNIT 2 IN THE DRAIN PAN AND 4 IN THE COIL SLAB. FAN UNIT MOTOR FAN DRAIN PAN HEATERS GUARD BOARD HARNESS DELAY MV(G)(H)-16-0600-1 M0010 F0012 F0204 E-0001 E-0030 1505D01 H-0010 E0004 MV(G)(H)-26-0850-1 M0010 F0012 F0204 E-0001 E-0030 1505D02 H-0015 E0004 MV(G)(H)-26-1200-1 M0010 F0012 F0204 E-0001 E-0030 1505D02 H-0015 E0004 MV(G)(H)-26-1350-1 M0010 F0012 F0204 E-0001 E-0030 1505D03 H-0020 E0004 MV(G)(H)-36-1800-1 M0010 F0012 F0204 E-0001 E-0030 1505D04 H-0025 E0004 MV(G)(H)-36-2000-1 M0010 F0012 F0204 E-0001 E-0030 1505D04 H-0025 E0004 MV(G)(H)-46-2800-1 M0010 F0012 F0204 E-0001 E-0030 1505D05 H-0030 E0004 MV(G)(H)-56-3600-1 M0010 F0012 F0204 E-0001 E-0030 1505D13 H-0035 E0004 MV(G)(H)-66-4500-1 M0010 F0012 F0204 E-0001 E-0030 1505D15 H-0035 E0004 NOTE: THERE ARE 2 HEATERS PER UNIT IN THE DRAIN PAN DRAIN FITTING KIT P0002 8

UNIT MOTOR FAN DRAIN PAN GUARD BOARD HARNESS BVA-16-0650-1 M0010 F0012 F0204 E-0001 E-0030 1505D21 BVA-16-0750-1 M0010 F0012 F0204 E-0001 E-0030 1505D21 BVA-26-0900-1 M0010 F0012 F0204 E-0001 E-0030 1505D09 BVA-26-1200-1 M0010 F0012 F0204 E-0001 E-0030 1505D09 BVA-26-1500-1 M0010 F0012 F0204 E-0001 E-0030 1505D09 BVA-26-1800-1 M0010 F0012 F0204 E-0001 E-0030 1505D11 BVA-36-2700-1 M0010 F0012 F0204 E-0001 E-0030 1505D10 BVA-46-3000-1 M0010 F0012 F0204 E-0001 E-0030 1505D12 BVA-56-3600-1 M0010 F0012 F0204 E-0001 E-0030 1505D13 FAN UNIT MOTOR FAN DRAIN PAN HEATERS GUARD BOARD HARNESS DELAY BVE-16-0650-2 M0015 F0012 F0204 E-0003 E-0030 1505D21 H-0015 E0004 BVE-16-0750-2 M0015 F0012 F0204 E-0003 E-0030 1505D21 H-0015 E0004 BVE-26-0900-2 M0015 F0012 F0204 E-0003 E-0030 1505D09 H-0025 E0004 BVE-26-1200-2 M0015 F0012 F0204 E-0003 E-0030 1505D09 H-0025 E0004 BVE-26-1500-2 M0015 F0012 F0204 E-0003 E-0030 1505D09 H-0025 E0004 BVE-26-1800-2 M0015 F0012 F0204 E-0003 E-0030 1505D11 H-0030 E0004 BVE-36-2700-2 M0015 F0012 F0204 E-0003 E-0030 1505D10 H-0035 E0004 BVE-46-3000-2 M0015 F0012 F0204 E-0003 E-0030 1505D12 H-0035 E0004 BVE-56-3600-2 M0015 F0012 F0204 E-0003 E-0030 1505D13 H-0035 E0004 NOTE: THERE ARE 6 HEATERS PER UNIT 2 IN THE DRAIN PAN AND 4 IN THE COIL SLAB. UNIT MOTOR FAN GUARD BOARD HARNESS DAIN PAN HEATERS FAN DELAY BV(G) (H)-16-0650-1 M0010 F0012 F0204 E-0001 E-0030 1505D21 H-0015 E0004 BV(G) (H)-16-0750-1 M0010 F0012 F0204 E-0001 E-0030 1505D21 H-0015 E0004 BV(G) (H)-26-0900-1 M0010 F0012 F0204 E-0001 E-0030 1505D09 H-0025 E0004 BV(G) (H)-26-1200-1 M0010 F0012 F0204 E-0001 E-0030 1505D09 H-0025 E0004 BV(G) (H)-26-1500-1 M0010 F0012 F0204 E-0001 E-0030 1505D09 H-0025 E0004 BV(G) (H)-26-1800-1 M0010 F0012 F0204 E-0001 E-0030 1505D11 H-0030 E0004 BV(G) (H)-36-2700-1 M0010 F0012 F0204 E-0001 E-0030 1505D10 H-0035 E0004 BV(G) (H)-46-3000-1 M0010 F0012 F0204 E-0001 E-0030 1505D12 H-0035 E0004 BV(G) (H)-56-3600-1 M0010 F0012 F0204 E-0001 E-0030 1505D13 H-0035 E0004 NOTE: THERE ARE 2 HEATERS PER UNIT IN THE DRAIN PAN DRAIN FITTING KIT P0002 9

ELECTRICALS (Wiring Diagrams) LPA, MVA & BVA Air Defrost LPE, MVE & BVE Electric Defrost 10

LP (G, H) Reverse cycle hot gas defrost & 3 pipes defrost MV (G, H) & BV (G, H) Reverse cycle hot gas defrost & 3 pipes defrost 11

PIPING LAYOUT (Piping Diagrams) LPG Reverse cycle hot gas defrost LPH Three pipes hot gas defrost 12

PIPING LAYOUT (Piping Diagrams) MVG & BVG Reverse cycle hot gas defrost MVH & BVH Three pipes hot gas defrost 13

HEAD OFFICE: ONTARIO SALES OFFICE: REFRIGERATION KOOL-AIR INC. REFRIGERATION KOOL-AIR INC. 100 Conrad Gosselin 237 Valleymede Drive Iberville, Québec Canada Richmond Hill, Ontario Canada J2X 5L6 L4B 2A3 Tel: (450) 346-5007 Tel: (905) 771-8972 Toll free: (1-866-346-5007 Fax: (905) 771-8908 Fax: (450) 346-7631 Due to Kool-Air policies to continuously improve the quality of its products, specifications are subject to change without notice. 14