Features The Classix Lensed Wall Wash shines new light on your bigger jobs. With a unique Amerlux blend of architectural form and function, Classix performs perfectly in large retail and commercial spaces. Designed for higher ceilings, this wall washer features high output and a commercial grade lens providing for an even wash of light on vertical wall surface. Remodeler version is ideal for existing application as this fixture installs from-below into ceilings. Product Overview Type: Recessed Round Wall Wash Wattage: 5, 4,, 5 Lumen Output:,79 max; Lm/W (5W data) CBCP:,479 max (5W data) Color Temp: 700K, 000K, 500K, 4000K, CRISP CRI: 8 typ. (700K, 000K, 500K, 4000K) + typ. (700K, 000K) Crisp LED available : TRIAC & ELV (0V/77V) - 5% Dim Lutron A Series (0V/77V), -wire/eco Hi-lume - % dim 0-0V (0V/77V) - % Dim DALI dimming Fixture Type Round New Construction Remodeler Trim Yes Yes Yes Yes Performance Chart Watts Delivered Lumens LPW CBCP Color Temp 5,97 80.4 780 000K-8 4,648 77.9,050 000K-8,56 74.6, 000K-8 5,79 7.,479 000K-8 Data is based on 5W 000K-8 IES files available on website See page 5 for other beam spreads 5 Title 4 Compliant Electrical Data 5W 4W W 5W 0V 5 0. 4 0.8 0.8 5 0.4 77V 5 0.09 4 0. 0.6 5 0.9 Electronic constant current LED driver LIT-08 0/08/8 Page of 7
Housing/Frame Ordering Information 4 Model For New Construction CLX-R6-NC-A7 (New Construction) For Existing Ceilings CLX-R6-REM-A7 (Remodeler) 4 (for non-dimming, select LE/TE option) LE/TE - TRIAC/ELV dimming HILUME-A - Lutron Hi-lume A Series, -wire/eco, Hi-lume, % dim (5W & 4W only) 0-0V - 0-0V dimming; % dim DALI - DALI dimming, % dim (5W, 4W & 46W only) Wattage 5 4 5 Voltage 0 77 Trim Ordering Information CLX-RLW6-A7 Model CLX-RLW6-A7 Finish SDW - semi-diffuse, white flange SDC - semi-diffuse, clear flange (flange finish matches cone finish) Color Temp 8 CRI + CRI 7-700K-8 79-700K-+ CRISP - Crisp 0-000K-8 09-000K-+ 5-500K-8 40-4000K-8 The "A" refers to the sequential revision in a year and "XX" refers to the year of update. Updates coincide with improved performance while not changing the overall fixture aesthetic and are reflected in the published performance data. Please contact your Amerlux representative for explanations of changes. LIT-08 0/08/8 Page of 7
Specifications Application Retail, commercial and hospitality wall wash lighting Construction 0 ga. galvanized steel frame 8 ga. galvanized steel splice housing and hanger brackets (not for Remodeler version) Passive cooling Extruded aluminum heat sink Optical Engineered nano technology lens provides transmission while concealing LED image Spun aluminum semi-diffuse aperture cone Wall wash beam distribution LED Color Temp Options: 700K, 000K, 500K, 4000K CRI: 8 typ. (700K, 000K, 500K, 4000K + typ. (700K, 000K) Crisp* LED available (seee description below) R9 Values: (8 CRI), 55 (9 CRI) Binning: MacAdam (SDCM) Life: 50,000+ hrs, > 70% of initial lumens at 50,000 hrs *Crisp: Crisp Technology delivers the warmth of colors expected from a high CRI solution but also creates the natural crisp white color that is pleasing to the eye. It creates the most impactful lighting ever available, by revealing the richest whites and vibrant colors that pop. Electrical Wattage: 5, 4,, 5 Electronic constant current LED driver, 0V or 77V input This product complies with IEEE C6.4 for surge endurance up to.5kv. Amerlux recommends using additional surge protection with this unit (supplied by others), surge and over voltage damage is not covered under warranty. s LE/TE - Leading Edge, TRIAC, forward phase/trailing Edge, ELV, reverse phase (standard) 0-0V, Lutron and DALI systems also available See pages 6-7 for more dimming information Finish (Trim) Wet paint Mounting For use in T-grid or sheetrock ceilings Adjustable hanger bars included (4 ½ - 5 std.) ( -48 Adjustable hanger bars available, consult factory) Certifications CSA damp as tested to UL 598 standards Damp location Warranty 5 year limited warranty LIT-08 0/08/8 Page of 7
Classix Round Lens Wall Wash: New Construction 5 /8 0 5 /6 4 /8 7 /6 4 /4 4 / min - 6 max 6 7 7 /6 Ceiling cut out: 7 dia. Remodeler Ceiling 7 /8 9 /6 7 /6 4 5 /6 0 /6 5/8 6 7 7 /6 Ceiling cut out: 7 dia. LIT-08 0/08/8 Page 4 of 7
FIXTURE DATA: (Complete photometric data (.ies format) available upon request) MULTIPLYING FACTORS: (Multiplying Factor is based on 000K-8 0V IES file on website) Wattage: 4W W 5W Factor: 0.7 0..0 CCT: 700K-8 000K-8 500K-8 4000K-8 700K-+ 000K-+ CRISP Factor: 0.96.0.0.04 0.80 0.8 0.65 5W LED (000K) LTL #047 Lumens:,97 5W LED (000K) LTL #0469 Lumens:,79 05 0 5 50 80 50 5 0 05 05 0 5 50 80 50 5 0 05 50 00 500 400 0 000 0 50 800 500 0 5 0 5 0 0 5 0 5 0 80 Deg. Plane 70 Deg. Plane 0 Deg. Plane Deg. Plane 80 Deg. Plane 70 Deg. Plane 0 Deg. Plane Deg. Plane ZONAL LUMEN SUMMARY Zone Lumens %Fixt 0-40 940 47.7 0-64 8. 0-97 00.0-80 0 0.0 Luminaire Efficacy: 80.4 lumens/watt ZONAL LUMEN SUMMARY Zone Lumens %Fixt 0-40 79 47.7 0-068 8. 0-79 00.0-80 0 0.0 Luminaire Efficacy: 7. lumens/watt Application Data: Feet From Wall Footcandles on Wall 5W LED (000K) Footcandles are average and rounded off. Data for multiple units are based on a minimum of five units. Distance from ceiling 0.5 8 9 0 9 8 9 0 9 8 9 0 9 8.5 5 7 0 7 5 7 0 7 5 7 0 7 5.5 4 6 5 5 6 5 5 6 4.5 9 0 4.5 4 5 6 6 6 7 7 7 6 6 6 6 5 5.5 0 0 0 0 6.5 6 7 7 8 8 8 8 8 8 8 7 7 6 7.5 4 4 5 5 5 5 5 5 5 4 4 Feet From Wall 5W LED (000K) Distance from ceiling 0.5 5 7 0 7 5 7 0 7 5 7 0 7 5.5 47 5 58 5 48 5 58 5 48 5 58 5 47.5 64 68 66 6 66 69 66 6 66 68 65 6.5 56 59 6 59 6 59 6 59 56 4.5 46 48 50 50 49 5 5 5 49 50 50 48 47 5.5 7 9 40 40 4 4 4 4 4 40 40 9 7 6.5 0 4 4 4 4 0 7.5 5 6 7 8 8 8 8 8 8 8 7 6 5 LIT-08 0/08/8 Page 5 of 7
DIMMING COMPATIBILITY: Amerlux Classix fixtures are compatible with all major dimming protocols prevalent in the United States. Please see below for general compatibilities and wiring diagrams. Amerlux recommends testing your unique dimming configuration as the exact full configuration (Dimmer, Fixture Quantity, Voltage, etc) may affect dimming performance. TRIAC (Forward Phase) DIMMING (Standard) Utilizes Standard incandescent dimmers that are in wide use in installations across the US. Best for retrofit applications where TRIAC dimmers are installed. 0V or 77V* Dims down to less than 5% light output (most cases) Consult manufacturer for installation Must meet dimmer Minimum Load Requirements per dimming manufacturer Wall Box (Incandescent Style, Wattage as required) Lutron Diva Lutron Vareo Lutron Nova-T Lutron Skylark Lutron Maestro TRIAC Wiring Diagram TRIAC ETC SR Rack w/d0 Module Lutron GP Panel ETC DRD Rack w/d0 Module Lutron Grafik Eye QS ELV - Electronic Low Voltage (Reverse Phase) DIMMING (Standard) Utilizes specialized ELV dimmers. Best for New Construction applications ELV Wiring Diagram 0V or 77V* Dims down to less than 5% light output (most cases) ELV Consult manufacturer for installation Must meet dimmer Minimum Load Requirements Wall Box (ELV Style) Lutron Diva Lutron Nova-T Lutron Maestro Leviton Surslide Lutron Vareo Lutron Skylark Leviton Vizio ETC SR Rack w/elv0 Module Lutron GP Panel with PHPM-PA Interface ETC DRD Rack w/elv0 Module Lutron Grafik Eye QS with PHPM-PA Interface 0-0V - DIMMING (-0-0V Option) Integrates into a variety of building management and daylighting controls 0-0V Wiring Diagram 0V or 77V* Dims down to % light output Requires interface to turn off power to driver Consult manufacturer for installation 0-0V Gray Purple 0-0V (-) 0-0V (+) Switched Hot Wall Box Lutron Diva - DVTV with PP- 0H Interface Leviton Renoir II 0-0v Lutron Grafik Eye with GRX-TVI Interface * is 77V dimmable with appropriate dimmer (by others). All provided wiring diagrams show 0V wiring colors and method. Please refer to 77V dimming installation instructions for 77V wiring diagrams. LIT-08 0/08/8 Page 6 of 7
DIMMING COMPATIBILITY: Amerlux Classix fixtures are compatible with all major dimming protocols prevalent in the United States. Please see below for general compatibilities and wiring diagrams. Amerlux recommends testing your unique dimming configuration as the exact full configuration (Dimmer, Fixture Quantity, Voltage, etc) may affect dimming performance. LUTRON A-SERIES HI-LUME / ECOSYSTEM (-DIM-HILUME Option) Integrates into Lutron Eco building management -Wire Wiring Diagram 0V or 77V* Dims down to less than 5% light output May use -Wire or Eco Consult manufacturer for installation Cap unused ECOSYS wires -Wire Phase Purple Stripe Purple Orange E E Dimmed Hot Switched Hot Wall Box (-Wire Fluorescent) DIVA Maestro Nova T Vareo Lutron Eco compatible controls ETC SR Rack w/d0f Module ETC DRD Rack w/d0f Module Eco Digital Wiring Diagram E E ECOSYS Bus Eco Purple Stripe E Purple E (Cap off Orange wire) Orange Dimmed Hot Switched Hot DALI DIMMING (-DALI OPTION) Digital control protocol allows individual fixture control DALI Wiring Diagram 0V - 77V* Dims down to % light output in most cases Wall Box (-Wire Fluorescent) Leviton CD50 ler DALI DALI Bus Purple Purple/WT Dynalite Fifth Light * is 77V dimmable with appropriate dimmer (by others). All provided wiring diagrams show 0V wiring colors and method. Please refer to 77V dimming installation instructions for 77V wiring diagrams. LIT-08 0/08/8 Page 7 of 7