A-MIP 210 Installation and user guide

Similar documents
A-MIP 200 Installation and Operating Manual

A-MIP 100 Installation and Operating Manual

User Manual YDR2108. Keep this manual safe for future reference

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

Wall Hung Boiler Room Thermostat OR30 OT Thermostat

Operating instructions Page 12

CABINET RANGES FOR AUTOMATED EXTERNAL DEFIBRILLATORS (AED)

PROTECTION CABINETS SUPERVISION CABINETS FOR AUTOMATIC EXTERNAL DEFIBRILLATORS (AEDs)

INSTRUCTION MANUAL FOR: WIRELESS SECURITY STARTER KIT MODEL NO: SWSKIT

User Manual Keep this manual safe for future reference

User Manual YDM The functions and design of this product can be changed without notice for quality improvement. Chinese manual is from 33 page.

USER MANUAL QSDL503AD Intelligent Auto-Dial Alarm System

ETSA380MF SHOWN WARNING. shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these devices to ensure compliance.

MODEL B2 INSTALLATION MANUAL

G34 AU1B (External Ultrasonic Sensor) Version 3

Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions

DIGITAL. Operation & Installation Guide. Read These Instructions Very Carefully! Home and Office Security Safes MFFS2054DF84DF18DFE0809 ENGLISH

Operator s Manual. The Quietek

TFD-1 Installation & User s Guide

Curv-infrared.com. The Smarter Way. To Heat Your Home. Installation & Operating Instructions For Cürv, Flat, Towel Rail and Mirror Infrared Heaters

MOBILE CALL GSM Alarm System User s Manual

Smart Home Outdoor Siren

FLCH4R Garage and Utility Electric Heater

Digital Programmable

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM AG100+ CONTENTS

RELEASE DEVICE CONTROLS

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

Design Manual Installation Operation Maintenance

ELIMINOSTAT DC-ESR-CL-S2

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

Towel Warmer MAKE EVERYDAY A SPA DAY

Mark 25 Ultrapure Water Conductivity Analyzer

For Android devices MYQ-G0301 MYQ-G0301C MYQ-G0301D MYQ-G0301LA

PHOTOVOLTAIC HEAT CONTROLER PVHC 2.01 USER MANUAL

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

Installation and Operation Manual. Model: STI TRIGGERED OUTPUT PLUG 12VDC, 75mA, 3 SEC. EMBOSSED PROGRAMMING

DIGITAL STEEL FIRE & SECURITY

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No &

ITEM # , , PAWTUCKET CEILING FAN MODEL #40958, 40959, 40047

For ios devices MYQ-G0301 MYQ-G0301C MYQ-G0301-D MYQ-G0301LA

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

External Wireless Sounder

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

Instruction Manual. Model AccuPlate Hotplate AccuPlate Stirrers AccuPlate Hotplate Stirrer 12/10 CLS-EQ-LHP01REV

Alarm System SECURE AS 302

MGC Dock User s Manual

PORTABLE AIR CONDITIONER (LOCAL)

Operator s Manual. The Bullet Blender 50 BB50-AU, BB50-DX. Contents. Congratulations!

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

Thermostats. Digital Programmable. GEAppliances.com

Network Camera. Quick Guide DC-T1233WHX. Powered by

DOL 31 Speed Controller Technical User Guide

Installation and ZONES: Operation Manual. Model: ON STI-34108

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

Refresh & Clean Carpet Washer

Total Connect Box. User manual

2-Port alarmcharge Hub - Manual

WIRELESS MEASUREMENT SYSTEM OF GAS BOTTLES FILLING LEVEL WITH GAS LEAK DETECTION GMS 300. User Manual

GB Operating instructions

Model Instruction Manual. Coleman Limited One-Year Warranty. 26 Quart Power Cooler. For use with 12 VDC only

DDS-SSENSOR - INSTALLATION MANUAL. Installation Manual DDS-S SENSOR

Suits all KPF849 models

Self-Setting Clock Radio

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

380 SERIES REMOTE SIREN ETSA380R

BSR Addressable Fire Detection control panel. Installation operation manual

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

1U ULTRA Compact System

Operating instructions 2-channel code lock. Item No

MST-1. Varifan USER S MANUAL MST-1 ADJUST. 9 per day HI F2. DIFF on off TIMER. reduc.

Projection Alarm Clock USER GUIDE

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires it.

Operator: Save these instructions for future use!

Alarm Tone Generator Model AG17

275HVD NON-CONTACT, HIGH VOLTAGE DETECTOR DETECTOR DE ALTA TENSIÓN SIN CONTACTO

Multi-Gas-Controller MGC2

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions

VX SERIES Wireless Thermostat with Occupancy Sensor

Table of Content LT 5165-UL

Protégé Eclipse LED Keypad User Manual PRT-KLES

Auto Dialer. Manual E-921APQ E-921GPQ

FIRERAY 5000 range USER GUIDE

52 CEILING FAN. Owner s Manual Models #50336, 50337

DLC Instruction Manual. Light Curing Machine MODEL. Table of Contents

External Wireless Sounder

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

HOME AUTOMATION, INC. Lumina and Lumina Pro Lighting and Automation System. Quick-Start Installation Guide

SPA DE USO PRIVADO SPA FOR PRIVATE USE SPA POUR UN USAGE PRIVÉ SPA FÜR PRIVATE NUTZUNG SPA PER USO PRIVATO SPA PARA USO PRIVADO SPA VOOR PRIVE-GEBRUIK

FreezeAlarm Dialer FA-700 Installation and Operations Manual

Operating instructions Page 14

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

System. For a better understanding of this product, please read this user manual thoroughly before using it.

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

Transcription:

20 A-MIP 20 Installation and user guide

General Information Important Read this manual before installation and use of the Aivia. Read this section carefully and follow the instructions. The warranty does not cover damage caused by failure to follow these instructions. AIVIA PROTECTION are wall mounted protection units that serve to house and shelter AEDs. The AIVIA PROTECTION does not ensure control of the AED, it is the sole responsibility of the DISTRIBUTOR to inform their own SUB-DISTRIBUTORS and USERS of their obligation to verify the presence and operating status of the AED by carrying out regular on site checkups. Depending on the options chosen, the AIVIA PROTECTION can trigger a visual and sound alarm. The alarm is intended as a warning signal in case of any malfunction, but no data log of malfunctions is recorded. In no event can the presence and operating status of AEDs in an AIVIA PROTECTION be controlled from a distance. The AIVIA should in no case be a substitute for the checks and inspections recommended by the manufacturer of the defibrillator. Installation must be carried out by a qualified operator or authorized by the Aivia s manufacturer Never install an AIVIA in direct exposure to sunlight. The unheated AIVIA must be installed in a temperate environment, in accordance with the manufacturer s s p e c i f i c a t i o n s f o r t h e d e f i b r i l l a t o r. The heated AIVIA must be installed in an environment that respects the operating temperatures of the AIVIA. You must monitor and follow up alerts related to temperature. The characteristics of the AIVIA are subject to changes without notice. The fixations must be adapted to the type of surface on which the AIVIA is fixed. The manufacturer cannot be held liable for improper installation or in the case of accident or injury during its installation. Warranty Do not disassemble the various elements that constitute the AIVIA. Do not insert any objects into any openings. Only qualified personnel may carry out repairs on the AIVIA. Failure to comply with this will void any warranty. Any operation or assembly procedures expressly prohibited or not recommended by this manual, will also void the warranty. Environmental information When returning the AIVIA, you should only use the original packaging. Do not dispose of the AIVIA or its packaging with normal household waste. Use the collection system in place in your area. The use of collection systems will help preserve the environment and your health. The AIVIA can contain batteries in compliance with EU Directives 2006/66/CE and 2008/03/CE. These cannot be disposed of with normal household waste. Please use the system for collecting used batteries in place in your area. The proper disposal of used batteries preserves the environment and your health. The manufacturer of the AIVIA reserves the right to change products at any time, including unlimited modifications to previously delivered products. The AIVIA brand is a registered trademark. Safety To avoid risk of fire or electric shock, the AIVIA should not be exposed to any naked flame. Leave a space of at least 3 cm around the AIVIA to assure proper ventilation. Keep the AIVIA away from radiators or any other heat source. Do not place the AIVIA near any devices that generate heat. Do not place anything under the AIVIA. To avoid damage, do not insert objects into any of the openings in the AIVIA. Maintenance CAUTION THE AIVIA CONTAINS BATTERIES. THERE IS A RISK OF EXPLOSION IF THE BATTERIES SUPPLIED FOR USE BY THE AIVIA ARE REPLACED BY INCORRECT BATTERIES. ONLY AN AUTHORIZED OPERATOR CAN CARRY OUT MAINTENANCE OPERATIONS, INCLUDING REPLACING THE BATTERIES. Never install the AIVIA in direct exposure to sunlight. Do not expose the AIVIA to any moisture when the door is open. 2

Summary Installation Important 4 Aivia presentation 4 Identification plate 4 Initial opening 4 Aivia installation 5 Connecting the power supply to the Aivia 6 Installing the AED 7 Setting up the Aivia 7 Door opening codes 7 Alert temperatures 7 Heating/Fan activation temperatures 8 Close the AIVIA door 8 Pictograms 8 Use 0 Night mode operation 0 Heating option operation 0 Alert operation 0 Using the Aivia 0 After using the defibrillator 0 Aivia maintenance 0 In case of malfunction Electrical Installation 3 Specifications Mechanical characteristics 4 Technical characteristics 4 Compliance 4 3

Installation Important Read this manual with carefully before setting up and using the Aivia. Never install Aivia Aivia in direct exposure to sunlight. You risk exposing the defibrillator to excessive temperatures. 0 Aivia presentation 0 Connector reserved for the AIVIA maintenance Connecting a cable to this connector can damage the AIVIA 3 4 2 Identification plate The identification plate is located inside the Aivia Reference Options 5 7 6 Serial number Electronic compartment. 2 Light sensor. 3 Seals support 4 Heating film *. 5 Night and alert indicators. 6 Door 7 Identification plate. * Option In the event you need to reach customer services or your distributor, please make sure you have your Aivia reference and serial number available. First opening To open the Aivia door before it is fixed on the wall, use a small screwdriver. Slip the screwdriver between the door and the chassis of the Aivia. Pull up the screwdriver, taking care to not leave marks on the Aivia. 8 9 8 Fixation holes. 9 AED holding sandow. Repeat on the other side of the Aivia. 4

300 mm 5,8 in 25 mm 8,46 in 50 mm 5,90 in Installation Aivia installation Never install an Aivia in direct exposure to sunlight. You risk exposing the defibrillator to excessive temperatures. Let a free space of 40 cm (55, in) in front of the supporting wall to allow for easy opening of the Aivia Useful area for Aivia working space Installation must be carried out by a qualified operator who adheres to the Bornavie charter or authorized by the Aivia manufacturer If the Aivia is installed in a public street or place with public access, install a fixed ground plate (abutment) or column. Fixations must be suitable for the type of surface which the Aivia is attached to. Aivia working zone must be kept free as specified above. 400 mm 55, in The exact dimensions of the Aivia are provided at the end of this document in the Specifications section. Make sure that every cable has been taken through the cable passage before affixing the Aivia to the wall. To mark fixations and cable passageway, use the drilling template provided with the packaging. Useful area for Aivia working space 220 mm 90 mm 220 mm 8,66 in 7,48 in 8,66 in 8,5 mm 0,33 in Put the template against the wall, with the arrow facing upwards and towards you. Fixation holes 24V DC Cables passage 5

Installation Fixing must be adapted to the type of support the Aivia is being fixed on. Aivia fixing must be able to carry a minimal load of 20 kg.(44lb). Fixing example: Connect the power supply to the Aivia The Aivia must be powered using 24V DC, see the «Power supply» section Slide the power supply cables through the cable passage. 2 3 4 2 Supporting wall. 2 Pin/Nylon plug. 3 Fixing screw, M6 minimum, M8 maximum. 4 Washer 4mm (0,55 in) maximum. Washer plus screw head thickness must not exceed 8mm.(0,3 in) Slide all the required cables through the hole before fixing the Aivia to the wall. Affix the Aivia using the 3 fixation holes. Connect power to the Aivia The Aivia must be supplied with 24VDC power, ensure compliance with the "Electrical Installation" section Cable passage 2 Power supply cables (24V) Connect the cables on the connector block respecting the polarity. +24V DC Red cable. 2 0V Black cable. 2 Plug the connector block onto the board. 2 Access door mounting screws. 2 Electronics access door Unscrew the fixing screw with a Philips screwdriver and pull out the hatch from the top Board power supply connector Check the power supply to the Aivia by verifying that the white indicators are illuminated. 6

Installation Put back the hatch, inserting the lower part first. Screw the hatch fixing screw using a philips screwdriver. Door opening codes Modifiying the user code : The user code allows the opening, it is by default set on 0000. Type the menu code 03, then validate : 0 3 Type the new user code on 4 digits, then validate ( e.g. 2222) : 2 2 2 2 Installing the AED Pull the holding strap and insert the AED behind the strap Modifying the maintenance code : The maintenance code allows the opening, and once opened, the Aivia set up. The default value is. Type the menu code 04, then validate : 0 4 Type the new maintenance code on 4 digits, then validate ( e.g. 3333) : 3 3 3 3 AED to be inserted vertically. 2 AED holding strap The strap allows for a simple extraction of the AED while ensuring the AED is securely held. Setting up the Aivia The Aivia is setup in maintenance mode. In order to do so, power up the Aivia with the door open, or type the maintenance code on the Keyboard. 2 Alert temperatures Low temperature alert entry (Heating option) : If this threshold is reached, The aivia will flash 4 times to indicate a temperature alert. Type the menu code 0, then validate : 0 Enter the low temperature alert threshold ( e.g. 5 C) 5 You can enter a negative temperature using the C key 2 3 4 5 6 7 8 9 0 C C 2 High temperature alert entry (Heating option) : If this threshold is matched, The aivia will blink 4 times to indicate a temperature alert. Type the menu code 02, then validate : Aivia keyboard All the entries are validated by the key. A A high pitched beep validates the entry whereas a low pitched beep signals an invalid entry. 0 2 Enter the high temperature alert threshold( e.g. 30 C) 3 0 7

Installation Heating/Fan activation temperatures Entering the heating temperature (Heating option) Heating will be triggered once this threshold is matched. It will stay activated as long as the temperature has not become warmer than the threshold. Type the menu code 03, then validate : Pictograms The signs on the door of AIVIA inform you of what to do in case of emergency. You must mark the emergency number to call in the SOS pictogram if one is not already noted there. 0 3 Enter the heating threshold ( e.g. 0 C) 0 You can enter a negative temperature using the C 2 C key Entering the fan activation temperature (Heating option): Fan activation will be triggered once this threshold is matched. It will stay activated as long as the temperature has not got colder than the threshold. Check that the instructions stay clear and unmasked. Type the menu code 04, then validate : 0 4 Enter the fan activation threshold ( e.g. 35 C) 3 5 Close the AIVIA door Completely close the Aivia door. Be sure to pull the door base toward you before shutting the door 8

Notes 9

Use Night mode operation The Aivia is equipped with a light detector. In low ambient light, blinking white lights help identify the location of the Aivia. Open the Aivia door by pulling it. Visual alert is given by the blinking ot the red indicators. Heating option operation The heating option allows to maintain the AED operating temperature within working temperatures. In extreme cold temperatures, it is worthwhile checking that the alert temperature is not signaled by the flashing of the red indicators. The fan allows the heat to be extracted from the Aivia. In hot weather, it is worthwhile checking that the alert temperature is not signaled by the flashing of the red indicators Take the AED out. Alert operation Door opening alert: When the door is opened the visual alert is given by the flashing of the red indicators. If your Aivia is equipped with the siren option (Reference : X2A20-XX00 or X2A20-XX0) It will be activated for 3 minutes. Temperature alerts: The temperature alert, signaled by 4 repeated flashings of the red indicators door close is triggered when the temperature gets below the minimum temperature defined, or over the maximum temperature defined. Using the Aivia If you witness an incident needing an AED. Contact emergency services. Speak using a clear and loud voice, describe the situation without forgetting to precise the incident location. The user code will allow you to unlock the aivia. Go to the victim. Switch on the AED. Follow the AED s instructions. After using the defibrillator Do not place the defibrillator back inside the AIVIA before reactivating it. Follow the instructions in the defibrillator s manual to reset it for use. The manufacturer may be able to help reactivate the defibrillator. Please feel free to contact them. After reactivating the defibrillator, replace it inside the AIVIA using the instructions in the section "Setting up the defibrillator." Aivia maintenance Type the user code to unlock the Aivia. Wash the Aivia surfaces using a wet cloth. Wipe the Aivia with a clean & dry cloth. Do not use washing or chemical products, they could damage it. Do not rub the Aivia with any hard object, you might damage it permanently or streak it. Do not use a high pressure cleaner. 0

In case of malfunction White indicators do not light up when the aivia is switched on.. Check the wiring polarity. 2. Check the power supply cable connection. 3. Check the voltage (24V) at the connector block. 4. Check the insertion of the connector block. 5. Contact your distributor White indicators do not blink in night operation.. Check the aivia power supply. 2. Contact your distributor Red indicators do not blink when the door is being opened.. Check the aivia power supply. 2. Contact your distributor Siren does not works when the door is opened.. Check for the siren option on the Avia identification plate. 2. Check the aivia power supply. 3. Contact your distributor I do not know my maintenance/user code.. Shut down the Aivia power supply. 2. Open the Aivia. 3. Switch on the Aivia, the white indicators will be illuminated. 4. Set the User/Maintenance code, as described in the «Setting up the Aivia» section. 5. Close the Aivia. Red indicators blink in a repeated way. Number of blinkings Cause Solution Failing memory Contact your distributor 2 Parameters lost Set-up the Aivia again 3 Temperature sensor breakdown Contact your distributor 4 Alert temperature reached Check the AED is working correctly, if needed, contact your distributor. Continuous Aivia has been opened Check AED operates correctly, and presence of all the accessories, if needed, contact your distributor. Aivia motorization doesn t work. Withdraw the cap off the aivia door, and push back the door blocking axle with a stem. Cap

Notes 2

Electrical Installation Power supply unit Mains grid 230 VAC/50Hz SELV Wiring Power supply 24VDC/3A CLASS I www.aivia.eu/doc/a-dpm.html Power Supply Unit Must be located outside the Aivia, never installed inside the Aivia. The power supply block must include: A 0A/30mA residual current device, serving both to protect and disconnect the hardware. SELV Wiring : U000R2V Type. 2 Isolated and gained conductors,,5mm² gauge, 0 meters maximum length. For the 24V wiring use a red or brown cable. For the 0V wiring use a black or grey cable. A SELV or equivalent 24VDC +-2% / 3A Class, TT Earthing system, with limited power output, and IEC 60950- conform. The cable connecting the residual current device and the power supply must be a section of,5 mm² The mains connection must include the primary phase, neutral, and earth. The maximum full load secondary voltage drop must not exceed 2%, or 23.5V at the Aivia terminal. The power block must be dust and water proof, and ventilated**. Wires must be held against themselves by a collar at the nearest of the holding terminals. The power block wiring must conform to standards in force in the country of use. * Recommended power supply: PYRESCOM C_AL/DR75-24. ** Natural or forced convection depending on the environnment and thermal characteristics at maximum load. 3

Specifications Mechanical characteristics Operating temperatures and humidity : Minimum: -20ºC.(-4 F) Maximum: 55ºC. (3 F) without battery option 40 C (04 F) with battery option Relative humidity: 95% without condensation. Temperature alerts: Low temperature alert: 5 C (4 F). High temperature alert: 40ºC (04 F) Heating option: (References: X2A220-XX00 or X2A220-XX0) Heating thresold : 0 C (50 F) by default. Fan thresold: 30 C (86 F) by default. Maximum weight capacity: 5Kg ( lb). Maximum altitude: 2000 m. Weight X2A20-XX000:2,9 Kg (6.39 lb). X2A20-XX00 (siren option): 3, Kg.(6.83 lb) X2A20-XX00 (heating option): 3 Kg..(6.6 lb) X2A20-XX0 (siren & heating option): 3,3 Kg. (7.27 lb) Compliance X2A20-XX***: EN 55022:2006 EN 55024: 998/ A : 200/ A2 : 2003 EN 60950- : 2006 Composition: Door: Polycarbonate. Chassis: ABS. Square: ABS. Hatch: ABS. Technical characteristics Power supply: 24 VDC +-2% / 3A, SELV source to limited power, complies with IEC 60950-. Current consumption: X2A20-XX000: Minimum: 55 ma. Maximum: 200 ma. X2A20-XX00 (siren option): Minimum: 55 ma. Maximum: 500 ma. Sound level: 90-05 db / meter. X2A20-XX00(heating option): Minimum: 55 ma. Maximum: 2000 ma. X2A20-XX0 (siren and heating option): Minimum: 55 ma. Maximum: 2400 ma. Sound level: 90-05 db / meter. 4

Notes 5

www.aivia.eu info@aivia.eu 203-07-03 *A-MIP20-EN-204* 6