Industrial Applications of pneumatic Systems

Similar documents
Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

II. METHODS AND MATERIALS

KELLOGG COMMUNITY COLLEGE INDUSTRIAL ELECTRICITY AND ELECTRONICS SPRING 2018

Photoelectric laser sensors E3C-LDA SERIES. l o n g - d i s t a n c e, a d j u s t a b l e l a s e r b e a m. Advanced Industrial Automation

SpeedStile FP. Full-Panel Speed Gate with Sliding Glass Barrier

COMPLETE PACKAGING SOLUTION

EDW500 / EDW503. Electronic Controls for Dishwashers

AUTOMATION & ROBOTICS

Operating Instructions

For more information, please visit or call toll free at

Bringing IoT innovation to the plant floor IO-Link series

Small diffuse reflective and convergent reflective type BYD50-DDT BYD50-DDT-U 1 BYD100-DDT BYD3M-TDT BYD3M-TDT-P

Safety Design EN ISO and Safety Performance Levels

Motor Condition Monitoring Devices K6CM series

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

5.0. Photoelectric Sensors. Technical Reference. Introduction

Catalog Number E57 product family or iprox. Description Tubular inductive proximity sensor

PHOTOELECTRIC AMPLIFIER SERIES

BL 53 Security Barrier ENGINEERING SPECIFICATIONS

Operating Instructions

SOCH AUTOMATION AND POWER SOLUTION

RFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance.

Operator Safety. Hierarchy of Safety. Hierarchy of Safety #5. Hierarchy of Safety #4. Hierarchy of Safety #1. Nip Points. Operator Safety 44.

Engineering Specifications

PLC-1700 Series PLC-1710, , 1760, , 1760L

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

Single Source for Machine & Process Safeguarding Solutions

CHECK NEW PRODUCTS SECTION FOR NEW INNOVATIVE SOLUTIONS

Revision date Section Change page(s) Description

Soft Start Series MP700 Solid State, Reduced Voltage

Automation at first hand. years

Operating Instructions

/ / 2018

Eclipse MC240. Double & Single Gate Controller with Eclipse Operating System (EOS) 3rd Edition. MC240 for Double and Single Gates.

Description of the application programme for KNX occupancy detectors version 3.1

AUTOMATIC ROOM LIGHT AND FAN CONTROLLER WITH BI- DIRECTIONAL VISITOR COUNTER

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

Product. PVI Corporate Mission PVI History Customer First. Short description. All Machine Type XT & XTX. Thermo-Dry-Ovens Service & Support

PLC Based Washing Machine

Proximity sensors. PRD Series. Long distance sensing proximity sensor. PR Series. Cylindrical type proximity sensor. PRA Series

General Specifications

Section 1 General Description

Machine Safety Sensing Control Products Automation Solutions

Sensing for standard and special applications

CM Series. Safety, Technology & Innovation. Description. Approvals. Operation. Applications. Certificate of Conformity

DSD-080 SEISMIC SECURITY PANEL DESCRIPTION FEATURES. DSD-080 User Manual

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

BLG77 Rising Fenced Barrier

Machine Safety Sensing Control Products Automation Solutions

LZR -WIDESCAN. Motion, Presence, and Safety Sensor for Industrial Doors (US version) DESCRIPTION ENGLISH

Transfer Switch Features

D-TEK -MS Vehicle Loop Detector. Operating Instructions

KwêBeams Effective wire free outdoor early warning system

Packaging Machine Library offers solution!

Series PHOTOSWITCH Photoelectric Sensors. Standard and Timing. Description. Supplied Accessories

WIRING DIAGRAM AND INSTRUCTIONS

DTA. Motor thermistor relay. Benefits. Description

Covidien Articulating Absorba Tack Foil Pouch Leak Tester Owner s Manual IPE SN Rev 1

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

Reflective Optical Beam Smoke Detector User Guide

BL41 Extra-long Barrier

Transfer Switch Features

Across-the-Line SERIES MP300 Combined Manual and Automatic

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

Devices for Special Applications

LS-CM Series. Overview. Applications. Features & Benefits. Datasheet. Ceiling mount occupancy sensors

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

MA Series. Safety, Technology & Innovation MA 12 MA 13. Description. Approvals. Operation. Applications. Declaration Conformity

DTA04. Motor thermistor relay. Benefits. Description

INSTRUCTION GUIDE DIGITAL CONTROLLER

SHR3D IT. Version 1.0 November English user guide

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

Ceiling PIR HS presence detector. Product Guide. Overview. Features

ZERTI ~CERTIFICAJE. Certificate holder. Product tested. Manufacturer. Type designation. Codes and standards forming the basis of testing

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

Rotodynamic Pumps INTRODUCTION:

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

D-TEK O P E R A T I N G I N S T R U C T I O N S V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

INSTRUCTION MANUAL. AlarmGard Chain Operator (Model FCA) AlarmGard Crank Operator (Model FKA)

F3SJ Overview. Three Versions available to meet your exact safety needs. Safety Light Curtains NEW! Introducing the F3SJ Series

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

ENGINEER S MANUAL No.01

User manual. ABB i-bus EIB. Zone Terminal MT/S Intelligent Installation System ABB STOTZ-KONTAKT

RELEASE DEVICE CONTROLS

DS160/161 Request To Exit PIR sensors Installation Instructions

ENGINEERED PARKING SYSTEMS MODEL 3416D

The rotary type compressor consists of an integrally formed rotor and shaft, five vanes, and a cylinder.

Ultrasonic Wall Switch Occupancy Sensor Single Circuit

SECURITRON MODEL XMS EXIT MOTION SENSOR INSTALLATION AND OPERATING INSTRUCTIONS

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

Control solutions Biofloor

Design of Electronic Control System for Robot Cleaning Machine Based on Profibus-DP. Wei GUAN

FLAKER/DCM SEQUENCE OF OPERATION

MANUAL RESET ALARM RELEASE

Switch Mode Power Supplies

Model B-350Touch Control Panel Operating Instructions

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

Transcription:

Islamic University of Gaza Faculty of Engineering Electrical Engineering Department Programmable Logic Controller Lab Eng. Mohammed S. Jouda Experiment 6 Industrial Applications of pneumatic Systems Objectives: After successfully completing this laboratory, you will be able to: Construct and operate industrial type pneumatic system that are electrically controlled Introduce speed control of pneumatic motor. Learn about electrical decoration of cylinders. Describe the operation of a photoelectric switch. Describe the operation of an electrical counter. Overview: Many industrial machine tools involve a cylinder that extends up to a workpiece at a high speed before it performs a work on it. As the rod of a fast-moving cylinder reaches a workpiece, however, it impacts against it with a great force. This impact can cause serious damage to either the cylinder or the workpiece. Impact damages can be minimized by decelerating the cylinder rod just before it contacts the workpiece. By using Flow control valves as shown in a figure 6.1, we can control it. Fig. 6.1: Flow Control Valve The Flow Control Valve consists of a needle valve and a reverse free-flow check valve connected in parallel. It restricts the flow rate in one direction, while allowing the air to flow freely in the other direction. 1

Bidirectional Motor : The Bidirectional Motor is a vane-type pneumatic motor that provides rotary motion in either direction. A white sticker affixed onto the motor shaft allows counting of the motor revolutions, using the Diffuse Reflective Photoelectric Switch. As shown in a figure 6.2 Speed control of a pneumatic Motor: Fig. 6.2: Bidirectional Motor The speed of a pneumatic motor depends on the flow rate. The flow rate and therefore the motor speed is usually controlled through the use of Flow Control Valves to control the speed of a bi-directional pneumatic motor as shown in a figure 6.3. Time-Delay Relay / Counter: Fig. 6.3: Speed control of bi-directional Motor The Time-Delay Relay / Counter consist in a programmable relay that can be programmed for either timing or counting function. The relay has two sets of normally open and normally closed contacts as shown in figure 6.4. 2

Photoelectricric Switches: Fig. 6.4: Time-Delay Relay / Counter A photoelectric switch is a sensing element that uses a light beam to sense the presence or motion of an object. Unlike a mechanical limit switch, it can perform these function without physical contact. Photoelectric switches have several useful applications, including cylinder position sensing, level sensing, product detection and counting, and speed monitoring. The photoelectric switch consist of a light source, a receiver, and one or more sets of NO and NC contacts, the light source may be visiable or infrared. Figure 6.5 shows the diffuse Reflective photoelectric switch, this switch is of the proximity type. It consists of a visiable light source and a reciver comined in the same casing. The light source project a beam of red light. When no object is within the dedction zone of the switch, the reciver sees dark and keeps the switch contacts deactivated. When a reflective object such as a cylinder rod enters the dedection zone. Light reflects off the object back to the reciver. This causes the receiver to activate the switch contacts and keep them activated until the object is removed from the detection zone. The diffuse Reflective photoelectric switch has a detection range of 10.2cm, which mean that it is able to detect objects located with in 10.2 cm. In this part, you will test the operation of a photoelectric switch.as shown in figure 3

Fig. 6.5: photoelectric Switch Procedure: Part 1: 1. Connect the pneumatic circuit shown in Figure 6.6. Use a Bidirectional Motor and Flow Control Valve. Fig. 6.6 Pneumatic Circuit 2. Connect the Electrical Circuit as shown in Figure 6.7. 3. On the time delay / counter, make sure the thumbwheel switches are set to A007 CO 4

Part 2: 1. By using PLC, complete a ladder diagram, The program should satisfy the following conditions: - After counter finish, the pneumatic motor stop and the cylinder move to right. - And if you press on Reset Pushbutton (PB5) the cylinder move to left. Hint : you can use Limit Switches. 5