Power Supply, Built-In DC/DC. XP POWER L L C SUITE E DYER RD SANTA ANA, CA United States

Similar documents
DC/DC Converter. ERICSSON AB FAROGATAN 6 STOCKHOLM, SE Sweden. ERICSSON AB FAROGATAN 6 STOCKHOLM, SE Sweden

EU Declaration of Conformity

Component Switching Power Supply. XP POWER L L C Suite E DYER RD Santa Ana, CA USA

Switching power supply. Additional Information on page 2 Input rating: Vac, 50-60Hz, 2.5A Output rating: 24Vdc, 8.33A max., 200W max.

Laptop Computer (OLPC)

Certificate of Compliance

CB TEST CERTIFICATE. Personal Computer. Acer Computer (Shanghai) Limited 3F, No. 168 Xizang Medium Road Huangpu District, Shanghai CHINA

CERTIFICATE. No. P Order No Page 1/2

File E Vol. 1 Sec. 93 Page 1 Issued: and Report Revised:

Certificate of Compliance

Independent controlgears

Certificate of Compliance

EU Declaration of Conformity

Power Supply for building-in TH-10280, THAILAND. See page 2. 0 Additional Information on page 2

EU Declaration of Conformity

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

DIN Rail Power Supply. Refer to page 2. [8] Additional Information on page 2. Input: Vac; 12 A; 50-60Hz Output: 24 V de; 40 A

Test Report issued under the responsibility of:

UL TEST REPORT AND PROCEDURE

TEST REPORT IEC Safety of household and similar electrical appliances Part 2: Particular requirements for massage appliance

Amendment to Test Report

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

CERTIFICATE. No. P Order No Page 1/2

IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME. Additional Information on page 2.

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address...:

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

Test Report issued under the responsibility of:

Provläsningsexemplar / Preview TECHNICAL REPORT. Part 3-1: Conformity verification report for IEC :2001 General requirements

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements. TÜV Rheinland Shanghai Co., Ltd.

TEST REPORT IEC , 2 nd Edition Part 1: Equipment classification and requirements

LED CONVERTER. Korea, Republic of SOLUM CO., LTD. Korea, Republic of. Additional information on page 2 OLU750P701U1U; OLU750P701U1A

File E Project 05ME Issued: November 1, 2005 Revised: February 27, 2009 REPORT

K-SQ13, KA-SQ13, K-SQ14, KA-SQ14, KO-SQ13, KOA-SQ13, KO-SQ14, KOA-SQ14, K-SQ13C, KA-SQ13C, K-SQ14C, KA- SQ14C, KO-SQ13C, KOA-SQ13C, KO-SQ14C,

This is a preview - click here to buy the full publication COMMISSION ELECTROTECHNIQUE INTERNATIONALE INTERNATIONAL ELECTROTECHNICAL COMMISSION

Installation and converting instructions to another gas type T4530, T4650

File E Project 97SC January 21, 1998 REPORT

Consumer Products Services Germany GmbH Türkheim Germany

EN50438 TEST REPORT SUMMARY. Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks

UL TEST REPORT AND PROCEDURE

Provläsningsexemplar / Preview TECHNICAL REPORT

LED CONVERTER. Korea, Republic of SOLUM CO., LTD. Korea, Republic of. Additional information on page 2 OLU700P142U1A; OLU700P142U1U

UL TEST REPORT AND PROCEDURE

ENEC NO2187. Nemko hereby grants the following manufacturer as licensee the right to affix this ENEC mark on the product(s) specified below.

IECEE OPERATIONAL DOCUMENT

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

File E90165 Vol. 2 Index Page 1 Issued: Revised: Construction United States Type Canadian Type Section

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Test Report Iec En Household And Similar

Concerning the use of GP4000 Series Graphic Operator Interface for applications in potentially explosive atmospheres (Zones 2/22)

Certificate of Compliance

AS/NZS :2016

COVER PAGE FOR TEST REPORT

Datasheet - AZM 161SK-12/12RK-024

Report reference No...: 10TH0052_AS4777_+_ISR_3 Tested by (printed name and signature)...: Urs Seifert. Approved by (printed name and signature)...

No. KM First Issued: 23/03/1998 Latest Issue: 11/08/2010 Page 5 of 9

Model SWH-3000 Proximity Multi-Frequency 125KHz & 13.56MHz (Fixed) Reader Installation Guide. Version A0 Part Number UM-102 September 2005

AB Parts. ControlNet Coax Tap. Installation Instructions. (Cat. Nos TPR, -TPS, -TPYR, -TPYS) What s in This Document

INTERNATIONAL STANDARD

TEST REPORT IEC60529 Edition TD990426C02

TEST REPORT IEC and/or EN Photobiological safety of lamps and lamp systems

REVISION HISTORY Rev Description Author. Approved by Date A Initial release per ECO Dean King Dean King November 16, 2012

AS/NZS :2009

Datasheet - AZM 161SK-12/12RK-024

EU Declaration of Conformity

DRAFT COMBINED POSTAL BALLOT/ AUSTRALIAN / NEW ZEALAND STANDARD FOR COMMENT

BS EN : A2:2015 used in conjunction with BS EN : A11:2014 and BS EN 62233:2008

1 BUSINESS ENVIRONMENT OF THE CEN/TC

Circuit Breakers JANUARY The electronic pdf version of this document found through is the officially binding version

Certificate of Compliance

Datasheet - MZM 100 ST2-1P2PWREM-A

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Declaration of Conformity

SOUTH AFRICAN NATIONAL STANDARD

Model SWH-4000 Multi-Technology Mullion 125 KHz and MHz (Flex) Reader Installation Guide. Version A0 Part Number UM-104 September 2005

Certificate of Compliance

For the user / for the installer. Instructions for Use and Installation. time SWITCH hour time clock

Test Report. Appliance EMF Testing

UL TEST REPORT AND PROCEDURE

TA-SCOPE. Balancing instrument ENGINEERING ADVANTAGE

Australian Standard. Degrees of protection provided by enclosures (IP Code) AS IEC Ed 2.1:2001 AS 60529

MW Pince courant de fuite Leakage current Clampmeter. Notice d utilisation User s Manual M3950M00

Report No.: SQE Page 2 of 11 Issued: Test Report No. : EMC -- T E S T R E P O R T SQE Equipment under Test : 24Bit Barometer

Medical devices and electromagnetic compatibility. Addressing the requirements of IEC , 4 th Edition

Original operating instructions Safety switch with guard locking AC901S AC902S

approach to assess the status of NSDIs

This document is a preview generated by EVS

Annubar Flowmeter Series

Technical Assessment Guideline Applicable for the Kiwa KQ Certification Scheme:

GUANGDONG XINYU TECHNOLOGY INDUSTRIAL CO., LTD

AS/NZS IEC :2013

EU DECLARATION OF CONFORMITY. 3. This declaration of conformity is issued under the sole responsibility of the manufacturer.

Illuminated Stopper Station Push Button

Household and similar electrical appliances Safety

Certificate of Compliance

Installation Instructions

Datasheet - MZM 100 B ST2-SD2PREM-A

ISO 3999 INTERNATIONAL STANDARD. Radiation protection Apparatus for industrial gamma radiography Specifications for performance, design and tests

Transcription:

Ref. Certif. No. US-19829-UL IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME SYSTEME CEI D'ACCEPTATION MUTUELLE DE CERTIFICATS D'ESSAIS DES EQUIPEMENTS ELECTRIQUES (IECEE) METHODE OC CB TEST CERTIFICATE Product Produit Name and address of the applicant Nom et adresse du demandeur Name and address of the manufacturer Nom et adresse du fabricant Name and address of the factory Nom et adresse de l'usine Note: When more than one factory, please report on page 2 Note: Lorsque il y plus d'une usine, veuillez utiliser la 2 ème page Ratings and principal characteristics Valeurs nominales et caractéristiques principales Trademark (if any) Marque de fabrique (si elle existe) CERTIFICAT D'ESSAI OC Power Supply, Built-In DC/DC XP POWER L L C SUITE 150 1241 E DYER RD SANTA ANA, CA 92705 United States XP POWER LTD 401 COMMONWEALTH DR HAW PAR TECHNOCENTRE LOBBY B, #02-02 149598 Singapore CINCON ELECTRONICS CO LTD 8-1 FU KUNG RD FU HSING PARK FU HSING HSIANG CHANGHUA HSIEN, 506 Taiwan Additional Information on page 2 See Page 2 XP Type of Manufacturer's Testing Laboratories used Type de programme du laboratoire d'essais constructeur Model / Type Ref. Ref. De type JCA02XXYZZ Series, JCA03XXYZZ Series See Page 2 Additional information (if necessary may also be reported on page 2) Les informations complémentaires (si nécessaire,, peuvent être indiqués sur la 2 ème page A sample of the product was tested and found to be in conformity with Un échantillon de ce produit a été essayé et a été considéré conforme à la As shown in the Test Report Ref. No. which forms part of this Certificate Comme indiqué dans le Rapport d'essais numéro de référence qui constitue partie de ce Certificat For building-in. Additionally evaluated to EN 60950-1:2006/A11:2009/A1:2010/A12:2011. National Differences specified in the CB Test Report. Additional Information on page 2 IEC 60950-1(ed.2), IEC 60950-1(ed.2);am1 E317867-A29-CB-2 issued on 2012-09-28 This CB Test Certificate is issued by the National Certification Body Ce Certificat d'essai OC est établi par l'organisme National de Certification Date: 2012-09-28 Signature: UL (US), 333 Pfingsten Rd IL 60062, Northbrook, USA UL (Demko), Borupvang 5A DK-2750 Ballerup, DENMARK UL (JP), Marunouchi Trust Tower Main Building 6F, 1-8-3 Marunouchi, Chiyoda-ku, Tokyo 100-0005, JAPAN UL (CA), 7 Underwriters Road, Toronto, M1R 3B4 Ontario, CANADA For full legal entity names see www.ul.com/ncbnames Jolanta M. Wroblewska 1/2

Ref. Certif. No. US-19829-UL Model Details: JCA02XXYZZ Series,JCA03XXYZZ Series (where XX = 05, 12, 24, or 48, Y = S or D, ZZ = can be any two digit number 01-15) Factories: DONGGUAN DONGCHENG ZHUSHAN CINCON ELECTRONICS FACTORY 1 JING XIANG RD DONGCHENG FOREIGN TRADE INDUSTRIAL PARK ZHUSHAN DONGCHENG DISTRICT DONGGUAN, 523128 GUANGDONG China Ratings: Input voltage: JCA02 Series 5Vdc (4.5-9.0Vdc), 700mA 12Vdc (9-18Vdc), 350mA 24Vdc (18-36Vdc), 175mA 48Vdc (36-75Vdc), 100mA JCA03 Series 5Vdc (4.5-9.0Vdc), 1000mA 12Vdc (9-18Vdc), 500mA 24Vdc (18-36Vdc), 250mA 48Vdc (36-75Vdc), 125mA Output: See Model Differences in the test report for details. Additional information (if necessary) Information complémentaire (si nécessaire) UL (US), 333 Pfingsten Rd IL 60062, Northbrook, USA UL (Demko), Borupvang 5A DK-2750 Ballerup, DENMARK UL (JP), Marunouchi Trust Tower Main Building 6F, 1-8-3 Marunouchi, Chiyoda-ku, Tokyo 100-0005, JAPAN UL (CA), 7 Underwriters Road, Toronto, M1R 3B4 Ontario, CANADA For full legal entity names see www.ul.com/ncbnames Date: 2012-09-28 Signature: Jolanta M. Wroblewska 2/2

Issue Date: 2012-09-28 Page 1 of 54 Report Reference # E317867-A29-CB-2 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment - Safety - Part 1: General requirements E317867-A29-CB-2 Date of issue... : 2012-09-28 Total number of pages... : 54 CB Testing Laboratory... : Address... : Applicant's name... : Address... : Test specification: UL San Jose 455 E. Trimble Rd., San Jose, CA, 95131-1230, USA XP POWER LLC SUITE 150 1241 E DYER RD SANTA ANA CA 92705 UNITED STATES Standard... : IEC 60950-1:2005 (2nd Edition); Am 1:2009 Test procedure... : Non-standard test method... : Test Report Form No.... : Test Report Form originator... : CB Scheme N/A IEC60950_1B SGS Fimko Ltd Master TRF... : 2010-04 Copyright 2010 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this test Report is used by non-iecee members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.

Issue Date: 2012-09-28 Page 2 of 54 Report Reference # E317867-A29-CB-2 Test item description... : Trade Mark... : Power Supply, Built-In DC/DC XP Manufacturer... : Model/Type reference... : Ratings... : XP POWER LTD 401 COMMONWEALTH DR HAW PAR TECHNOCENTRE LOBBY B, #02-02 SINGAPORE 149598 SINGAPORE JCA02XXYZZ and JCA03XXYZZ Series (where XX = 05, 12, 24, or 48, Y = S or D, ZZ = can be any two digit number 01-15) Input voltage: JCA02 Series 5Vdc (4.5-9.0Vdc), 700mA 12Vdc (9-18Vdc), 350mA 24Vdc (18-36Vdc), 175mA 48Vdc (36-75Vdc), 100mA JCA03 Series 5Vdc (4.5-9.0Vdc), 1000mA 12Vdc (9-18Vdc), 500mA 24Vdc (18-36Vdc), 250mA 48Vdc (36-75Vdc), 125mA Output: See model differences for details.

Issue Date: 2012-09-28 Page 3 of 54 Report Reference # E317867-A29-CB-2 Testing procedure and testing location: [ ] CB Testing Laboratory [x] Associated CB Test Laboratory Tested by (name + signature)... : UL Brea 2929 Imperial Hwy, Ste 100, Brea, CA, 92821, USA Karl Bier Approved by (name + signature)... : Linus Park [ ] Testing Procedure: TMP Tested by (name + signature)... : Approved by (+ signature)... : [ ] Testing Procedure: WMT Tested by (name + signature)... : Witnessed by (+ signature)... : Approved by (+ signature)... : [ ] Testing Procedure: SMT Tested by (name + signature)... : Approved by (+ signature)... : Supervised by (+ signature)... : [ ] Testing Procedure: RMT Tested by (name + signature)... : Approved by (+ signature)... : Supervised by (+ signature)... : List of Attachments National Differences (41 pages) Enclosures (132 pages) Summary Of Testing Unless otherwise indicated, all tests were conducted at UL Brea 2929 Imperial Hwy, Ste 100, Brea, CA, 92821, USA. Tests performed (name of test and test clause) Guide Information Page - Maximum Output Voltage, Current, and Volt Ampere Measurement (1.2.2.1) Testing location / Comments

Issue Date: 2012-09-28 Page 4 of 54 Report Reference # E317867-A29-CB-2 Input: Single-Phase (1.6.2) SELV Reliability Test Including Hazardous Voltage Measurements (2.2.2, 2.2.3, 2.2.4, Part 22 6.1) Determination of Working Voltage; Working Voltage Measurement (2.10.2) Heating (4.5.1, 1.4.12, 1.4.13) Electric Strength (5.2.2) Component Failure (5.3.1, 5.3.4, 5.3.7) Power Supply Output Short-Circuit/Overload (5.3.7) Summary of Compliance with National Differences: Countries outside the CB Scheme membership may also accept this report. List of countries addressed: AT, BE, BG, CA, CH, CN, CZ, DE, DK, ES, EU, FI, FR, GB, GR, HU, IE, IL, IT, JP, KR, NL, NO, PL, PT, RO, SE, SG, SI, SK, UA, US The product fulfills the requirements of: CSA C22.2 No. 60950-1-07 + A1:2011, EN 60950-1:2006 + A1:2010 + A11:2009 + A12:2011, UL 60950-1 2nd Ed. Revised 2011-12-19

Issue Date: 2012-09-28 Page 5 of 54 Report Reference # E317867-A29-CB-2 Copy of Marking Plate The artwork below may be only a draft. The use of certification marks on a product must be authorized by the respective NCBs that own these marks.

Issue Date: 2012-09-28 Page 6 of 54 Report Reference # E317867-A29-CB-2 Test item particulars : Equipment mobility...: Connection to the mains...: Operating condition...: Access location...: Over voltage category (OVC)...: Mains supply tolerance (%) or absolute mains supply values...: Tested for IT power systems...: IT testing, phase-phase voltage (V)...: Class of equipment...: Considered current rating of protective device as part of the building installation (A)...: - Pollution degree (PD)...: 2 IP protection class...: for building-in N/A continuous for building-in N/A No direct connection No N/A Special Application - TNV-2 IP X0 Altitude of operation (m)...: 3048 Altitude of test laboratory (m)...: Mass of equipment (kg)...: 0.02 Possible test case verdicts: - test case does not apply to the test object... : N / A - test object does meet the requirement... : P(Pass) - test object does not meet the requirement... : F(Fail) Testing: less than 2000 meters Date(s) of receipt of test item...: 2006-12-11 Date(s) of Performance of tests...: 2006-12-12 General remarks: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the testing laboratory. "(see Enclosure #)" refers to additional information appended to the report. "(see appended table)" refers to a table appended to the report. Throughout this report a point is used as the decimal separator. Manufacturer's Declaration per Sub Clause 6.25 of IECEE 02: The application for obtaining a CB Test Certificate includes more than one factory and a declaration form the Manufacturer stating that the sample(s) submitted for evaluation is (are) representative of the products from each factory has been provided... Yes When differences exist, they shall be identified in the General Product Information section. Name and address of Factory(ies): CINCON ELECTRONICS CO LTD

Issue Date: 2012-09-28 Page 7 of 54 Report Reference # E317867-A29-CB-2 8-1 FU KUNG RD FU HSING PARK FU HSING HSIANG CHANGHUA HSIEN 506 TAIWAN DONGGUAN DONGCHENG ZHUSHAN CINCON ELECTRONICS FACTORY 1 JING XIANG RD DONGCHENG FOREIGN TRADE INDUSTRIAL PARK ZHUSHAN DONGCHENG DISTRICT DONGGUAN 523128 GUANGDONG CHINA GENERAL PRODUCT INFORMATION: Report Summary All applicable tests according to the referenced standard(s) have been carried out. Product Description The products covered by this report are single and dual output, dc/dc converters. They are provided with input and output connectors (pins) for connection to a source of supply and to the load. All components are mounted on a printed wiring board. Model Differences All models within the JCA02 and JCA03 Series were identical with exception to Transformer Winding Ratio and Number of Windings and minor secondary differences to accommodate different output voltages. Model V1 Rated V2 Rated JCA02XXS03 +3.3V 0.6A JCA02XXS05 +5V 0.4A JCA02XXS12 +12V 0.17A JCA02XXS15 +15V 0.14A JCA02XXD01 +5V 0.2A - 5V 0.2A JCA02XXD02 +12V 0.085A -12V 0.085A JCA02XXD03 +15V 0.07A -15V 0.07A JCA03XXS03 +3.3V 0.91A JCA03XXS05 +5V 0.6A JCA03XXS12 +12V 0.26A JCA03XXS15 +15V 0.20A JCA03XXD01 +5V 0.3A - 5V 0.3A JCA03XXD02 +12V 0.13A -12V 0.13A JCA03XXD03 +15V 0.1A -15V 0.1A Input: XX indicates input voltage: 05 for 5V(4.5-9.0Vdc), 12 for 12V(9-18Vdc), 24 for 24V(18-36Vdc) and 48 for 48V(36-75Vdc). Suffix "S" = Indicates Single Output Suffix "D" = Indicates Dual Output

Issue Date: 2012-09-28 Page 8 of 54 Report Reference # E317867-A29-CB-2 Additional Information This Test Report is a reissue of CBTR Ref. No. E317867-A29-CB-1, CB Test Certificate Ref. No. DK-19033- A1. Based on previously conducted testing and the review of product technical documentation it was determined that the product complies with the upgrade of the Second Edition of the standard to Amendment 1. Label provided represents all models. The label is a draft of an artwork for marking plate pending approval by National Certification Bodies and it shall not be affixed to products prior to such an approval. Technical Considerations The product was submitted and evaluated for use at the maximum ambient temperature (Tma) permitted by the manufacturer s specification of: 75 C The product is intended for use on the following power systems: Regulated DC source. The product was investigated to the following additional standards: EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 (which includes all European national differences, including those specified in this test report).,, Engineering Conditions of Acceptability When installed in an end-product, consideration must be given to the following: The following Production-Line tests are conducted for this product: Electric Strength The following secondary output circuits are SELV: All outputs The following secondary output circuits are at non-hazardous energy levels: All Outputs The power supply terminals and/or connectors are: Not investigated for field wiring The investigated Pollution Degree is: 2 The following end-product enclosures are required: Mechanical, Fire, Electrical The source to these dc/dc converters are intended to be supplied from an isolated source, such as a battery, or a source which meets the requirements for basic (ELV) or reinforced (SELV) insulation from primary (mains) or TNV-2 circuitry, depending on output type required.,, If the input meets all the requirements for ELV, the outputs may be considered ELV.,, If the input meets all the requirements for SELV or TNV-2, then the outputs may be considered SELV. Output voltages remain within SELV limits, even with internally generated non-selv voltages, if any. -- The input and output connectors (pins) have not been evaluated for field connections and are only

Issue Date: 2012-09-28 Page 9 of 54 Report Reference # E317867-A29-CB-2 intended for connection to mating connectors of internal wiring inside the end-use machine. The acceptability of these and the mating connectors relative to secureness, insulating materials and temperature shall be considered. -- The units shall be installed in compliance with the enclosure, mounting, spacing, casualty, and segregation requirements of the end-use application. -- The need for humidity testing to be considered as part of the end product. -- Abbreviations used in the report: - normal condition...n.c. - single fault condition...s.f.c - operational insulation...op - basic insulation...bi - basic insulation between parts of opposite polarity: BOP - supplementary insulation...si - double insulation...di - reinforced insulation...ri Indicate used abbreviations (if any)