For Heavy Duty Commercial and Industrial Environments

Similar documents
HDL106 LED LUMINAIRES. For Harsh & Hazardous Environments.

WELCOME TO HAWKE INTERNATIONAL INTERACTIVE CATALOGUE

A QUALITY COMPANY ALWAYS DEMANDS THE BEST

IECEx Certificate of Conformity

Total Fire Solutions. Includes BS 8519 and the updated BS :

THE TRUE FIRE SURVIVAL CABLE

INNOVATIVE THINKING HAS MADE US AN INDUSTRY LEADER.

High Performance LSZH Fire Resistant Cable

Fire Resistant Cables

North American Cable Glands

FIRE RESISTANT CABLES FP300

Fixing points M6 (1/4 )

STANDARDS INSTALLATION. Certificate No 077m

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.

Introduction.

DB4 Range - SPEAKERS - Up to 25 Watts

GUARDIANTM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED MECHANICALLY PROTECTED CABLES

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

Tel: +44(0) Fax: +44(0) /17 LGM Products Ltd. Web: ISO 9001:2015 certified

CABLE & HOSE PROTECTION PRODUCT OVERVIEW

FIRE RESISTANT CABLES FP200 GOLD

CCTV quick connect Harsh and Hazardous area connectors for camera stations

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data

Connecta System THE FIRE PERFORMANCE TUNNEL LIGHTING AND POWER SYSTEM

All Prysmian FP400 cables are manufactured under an ISO 9001 Quality System certified by BASEC and LPCB.

Earth-Rite II PLUS Static Earthing System

FIRE RESISTANT CABLES FP PLUS. New Generation. Now with enhanced Insudite TM insulation

STT700 Temperature Transmitter Lightning Protection Device Specifications 34-TT-03-20, June 2017

HWT-P HWAT POWER CONNECTION KIT WITH END SEAL INSTALLATION INSTRUCTIONS

Fibre Solutions for Harsh Environments

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

ENERGY /// TE S RAYCHEM CABLE CLAMPS TE CONNECTIVITY S (TE) RAYCHEM CABLE CLAMPS

Flameproof Manual Call Points Series MCP

Energy Saving Band Heaters

TE S RAYCHEM PLUG-IN TERMINATIONS (RPIT) INNER CONE SYSTEMS FOR SWITCHGEARS AND TRANSFORMERS UP TO 52 kv

Titan Optima &Titan Optima plus Swimming Pool Heater with Ultra Efficient Titanium Heating Elements

BS /1000V XLPE Insulation LSZH Sheath Cables

TUNNELS BOXES AND CONNECTORS

TUNNELS BOXES AND CONNECTORS

MaxGard. Interconnection Systems. Durability. Performance. Safety

Fire protection in tunnels and public buildings

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

flexible conduit solutions for rail THE POWER IN CABLE MANAGEMENT

zonex enclosures hazardous locations

Industrial & Hazardous Area Electrical Equipment

Hubbell Harsh & Hazardous. Our Brands. Corporate Information

Hubbell Harsh & Hazardous. Our Brands. Corporate Information

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

FIRE RESISTANT CABLES FP200 GOLD

An introduction to... Sigma

ST E /ST E / ST E / ST E ST E / ST E / ST E

Heavy Industrial/Marine MaxGard

Photovoltaic Cables EN H1Z2Z2-K

The Quality Connection. BETAflam Fire Resistant Safety Cables

FIRE RESISTANT CABLES FP400

UNIVERSAL SOLVENT HEATER

Technical Manual for the Alarm Pull Station PH1

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

AFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

Components List THERMAL / MANUAL GENERATORS. 30 T Stat-X Thermal Generator. 60 T Stat-X Thermal Generator. 60 T Long Stat-X Thermal Generator

V3 Intelligent Damper Control and Monitoring System

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

COMPONENT SOLUTIONS for the lighting industry

DB5 Intrinsically Safe Sounder Type DB-5

JBS-100-ECP-A COMBINATION POWER CONNECTION BOX AND DIGITAL ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

INSTALLATION & OPERATION MANUAL

Hazardous Area Portable Fan Heater The Bulldog

Factory and Field Installed Splices

QUANTURA DISHWASH DOSING SYSTEMS. revolutionary dispensing solutions

Flame Retardant Overall Screened Instrumentation Cables (multicore)

Overmoulded Cable Assembly Selector Guide

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Integrated redundant fieldbus power for FBM228 Foundation fieldbus modules High-density, compact design Fully isolated

LINEAR HEAT DETECTION SENSOR CABLE ACCESSORIES

SOLUZIONI PER ATMOSFERA ESPLOSIVA

Havells Fire Survival Cables

24 & 30 Drum Fan. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Condensate Drain Valves

Section 4: Medium Voltage Terminations - up to 42kV

Operating Instructions

fire resistant cables

Dräger QuadGard Control System

M7100 Pressure Transducer

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

Electronic Control Systems Sensors

EX-TECH SIGNALLING SAS SD100-1 WEATHERPROOF SOUNDER/HORN TECHNICAL MANUAL

ORDER GUIDE Authorised Reseller

ATEX Enclosures. Safety in an explosive atmosphere

10 & 12 Ventilator. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

INSTALLATION, OPERATION AND SERVICE MANUAL AERATION SYSTEMS FEATURING AIR COMPRESSOR AND AIR ELIMINATOR TANK

Fuel Manager Diesel Fuel Filtration. FM1, FM10, FM100 and FM1000 Complete Systems, Elements and Service Parts

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

ELECTRICAL EX EQUIPMENT

BS-1015BSW. WARNING Indicates a potentially hazardous situation which, if mishandled, could result in death or serious personal injury.

Safegard V4 Bespoke Intelligent Damper Control and Monitoring System

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Section 8: Switchgear Connections (Straight & Elbows)

Transcription:

T O U G H M AT E F I R E M AT E For Heavy Duty Commercial and Industrial Environments www.ehawke.com

Connecting you through innovation Experienced With over 60 years experience protecting people and assets in the world s most demanding environments, Hawke is the obvious choice for reliability, quality and safety. Worldwide Our global network of distributors can support you wherever you are. Quality-Driven All Hawke products are designed to not only comply with ISO 9001 standards but to exceed all the latest standards. Rigorous in-house and third party testing ensures that all our products exceed expectations. Complete Solution With an extensive range of Cable Glands, Enclosures, Connectors, Accessories, Control Stations and more Hawke International can provide you with a complete solution, no matter what your project is.

HAWKE INTERNATIONAL Safety, when you need it most CONTENTS When you need to get people out, you need a system that can take the pressure. The Hawke ToughMate and FireMate range are designed specifically to provide unparalleled strength in evacuation and rescue situations. Tested to the latest industrial and fire standards (BS EN 61984, voltage directive LVD 2014/35/EU, BSEN50200:2006 and BS8434-2:2003 + A2 2009) the range will maintain its structural integrity in the world s most severe environments. The ranges are ideal for underground and overground rail networks, marine safety and commercial and public building applications. Wherever safety is the highest priority, choose FireMate and ToughMate. TOUGHMATE 5 Overview 6 TM Connector 8 TM EJB Enclosures 9 TM CW Cable Gland 10 TM E1W Cable Gland 11 TM A2 Cable Gland FIREMATE 13 Overview 14 FM Connector 16 FM EJB Enclosure 17 FM CW Cable Gland 18 FM E1W Cable Gland 19 FM A2 Cable Gland 3

TOUGHMATE PRODUCTS Built for the Harshest Environments Harsh Environments demand unparalleled strength. That s why we created the Hawke ToughMate range. Tested to the latest industrial standards (BS EN 61984 and LVD 2014/35/EU), the range has been developed to maintain its structural integrity in the world s most severe environments. Ideal for underground and overground rail networks and commercial and public building applications the ToughMate is necessary wherever safety is imperative. The Range The ToughMate range of Connectors, Enclosures and Cable Glands provides a complete solution for use in emergency lighting circuits, fire alarms, voice alarms, shutdown systems and fire detection. The ToughMate Connector Designed for strength and easy installation, the ToughMate connector is ideal for use in rail, commercial and public applications. Its innovative fuse pin design gives circuit protection without the need for Enclosures and the custom peg design ensures the correct mating locations, every time. The ToughMate EJB Enclosure The EJB just got tougher. The Zinc Plated Mild Steel ToughMate Enclosure range combines all the incredible strength and corrosion resistance of our best-selling EJB range with unparalleled industrial strength. For simple installation and superior strength the TM EJB is the ideal choice. The ToughMate Cable Gland Range The ToughMate range combines the Hawke s market-leading Cable Gland technology with rigorous in-house third party industrial testing to ensure exceptional performance, even in the most severe conditions. Ideal for heavy industrial or critical safety environments which are exposed to dust or extreme weather conditions the ToughMate Cable Gland range combines easy assembly with exceptional strength to increase productivity and give you peace of mind when you need it most. 5

CONNECTOR TOUGHMATE MADE IN BRITAIN TOUGHMATE CONNECTOR The ToughMate connector has been developed to be used on underground and overground rail networks, commercial and public buildings where equipment needs to withstand the harshest of environments. Tested to the latest Industrial BS EN 61984 and LVD 2014/35/ EU our connector will maintain its electrical and structural integrity during the toughest conditions. The product is designed to be used in emergency lighting circuits; fire alarms; voice alarms; shutdown systems and fire detection. Technical Data Construction and Test Standards: BS EN 61984, GPSD (2001/95/EC) Ingress Protection: IP66 Material: Nickel Plated Brass or Stainless Steel 316 Operating Temperature: Range: -25 C to +70 C Clamping Arrangement: Single compression seal Earth: Electrical continuty using earth pin and body connection Cable Type: Unarmoured cable Number of Cores: 4 + Earth Dali ready Core Size: Up to 6mm² Current range: 5, 10 & 15 Amps with Fuse, 16 Amps without Voltage range: 250 V Assembly Instructions: AI 504 Max No. of make & break operations (EN61984): on and off load 500 Ordering Options Manufacture Hawke H Type ToughMate TM Material Nickel Plated Brass N Stainless Steel S Connector Style The CP is always supplied with pin contacts FUSE pin Connector Plug CP Connector Receptacle CR Bulkhead Receptacle BR Besa Box Receptacle BB 3 Amp F3 5 Amp F5 10 Amp F10 15 Amp F15 Not Required or N/A for receptacle X * For best practice please ensure that the socket side is energised only Sample Order Code Manufacture/Type/Material etc H/TM/S/CP/F5 = Hawke, ToughMate, Stainless Steel, Connector Plug, with 5Amp Fuse. 6

TOUGHMATE CONNECTOR ToughMate Features 1 2 3 1. Unique fuse pin design available to give circuit protection without the need for enclosures. 2. Quick Connect via a 4 start thread Earth and Key location Screw 3. Custom peg design to ensure correct mating locations every time. Besa Box Receptacle to Connector Plug For Besa Box Mounting 49.5 65 75 70 35 23 Bulkhead Receptacle to Connector Plug For Enclosure/Equipment Mounting 49.5 46 75 70 23 45 M40 x 1.5 Connector Receptacle to Connector Plug For Inline Connections 49.5 44 75 70 23 17 66 61 Connector plugs and connector receptacles accept a cable OD of 10mm to 14mm. For any cable OD outside of these sizes, please contact Hawke Sales for more details. All bulkhead receptacles are supplied with an M40 entry. 7

ENCLOSURE TOUGHMATE MADE IN BRITAIN TM EJB FACE A Z Y Diameter 10mm T V FACE D W FACE B S INT / EXT EARTH V X FACE C M6 Int/Ext Earth 178 EJB1 EJB2 Dimension Size (mm) Size (mm) S 120 150 T 2 2 V 80.5 90.5 W 96 126 X 126 156 Y 96 126 Z 148 178 Terminal Type Conductor Size (mm2) Min. Maximum Quantity of Entries Per Face Thread Size M16 M20 M25 M32 M40 M50 Box Type TM TM TM TM TM TM TM TM TM TM TM TM EJB1 EJB2 EJB1 EJB2 EJB1 EJB2 EJB1 EJB2 EJB1 EJB2 EJB1 EJB2 Face A/C 6 8 5 6 3 3 2 2 1 2 0 1 Face B 4 7 3 5 2 3 1 2 1 1 0 1 Face D 6 7 4 6 3 3 2 2 1 2 0 1 Max. Terminal Capacity Max. Volts Max. Physical Terminal Content Terminal Qty Amps TM EJB1 TM EJB2 TM EJB1 TM EJB2 WDU 2.5N 0.5 2.5 420 12 18 15 13 WDU 2.5 0.5 2.5 550 12 18 15 13 WDU 4 0.5 4 690 10 15 20 18 WDU 6 0.5 6 550 7 11 11 24 WDU 10 1.5 10 550 6 9 9 34 WDU 16 1.5 16 550-7 - 47 BK 6 1 4 275 1 1 21 21 MK 6/6 1 6 420 1 1 26 26 Features ToughMate enclosures have been developed to be used on underground and over ground rail networks, commercial and public buildings, where equipment needs to withstand the toughest of environments. Technical Data Ingress Protection IP66 to IEC/EN 60529 Material Zinc Plated Mild Steel Operating Temperature Range: -60 C to +80 C Assembly Instructions AI 298 Ordering information - please state the following; Box size, Terminal quantity/size, Gland entry quantity, Size/position For any further help with enclosure configuration please contact Hawke International 8

TOUGHMATE CABLE GLAND 'L' Entry 'G' Approx (Fully Compressed Length) Armour 'C' TM CW MADE IN BRITAIN 'T' Entry Thread Ø 'A' Ø 'B' A robust and simple design for applications using SWA or AWA cable in a heavy industrial environment which is exposed to dust or extreme weather conditions. All cable glands can be supplied with a shroud, lock nut, serrated washer and an earth tag. Size Ref. Entry Thread Size 'T' NPT* Standard or Option Length of Thread (mm) L Cable Gland Selection Table Inner Sheath A Cable Acceptance Details Outer Sheath 'B' Min Max Armour 'C' G Hexagon Dimensions Across Flats Across Corners Os M202 ½" 10 8.0 6.5 16.0 0.8/1.25 49.0 24.0 26.5 O M202 ½" 10 11.9 6.5 16.0 0.8/1.25 49.0 24.0 26.5 A M20 ¾" or ½" 10 14.3 11.5 20.9 0.8/1.25 49.0 30.0 32.5 B M25 1" or ¾" 10 20.2 17.0 27.2 1.25/1.6 52.0 36.0 39.5 C M32 1¼" or 1" 10 26.5 23.5 33.6 1.6/2.0 60.0 46.0 50.5 C2 M40 1½" or 1¼" 15 32.5 31.0 43.0 1.6/2.0 63.0 55.0 60.6 D M50 2" or 1½" 15 44.4/42.3¹ 36.0 52.6 2.0/2.5 70.0 65.0 70.8 E M63 2½" or 2" 15 56.3/54.3¹ 52.0 65.3 2.0/2.5 76.0 80.0 88.0 F M75 3" or 2½" 15 68.2/65.3¹ 64.0 78.0 2.0/2.5 76.0 95.0 104.0 'T' - metric entry threads are 1.5mm pitch as standard. All dimensions in millimetres (except * where dimensions are in inches). 1 Smaller value is applicable when selecting reduced NPT entry option 2 Sizes Os and O are available with an M16 thread size. For O size with M16 thread, the maximum cable inner sheath diameter is 10.9mm Technical Data Construction and Test Standards BS EN 62444:2013 BS6121: Part 1 type CW Ingress Protection IP66 IEC/EN 60529 Material Operating Temperature Clamping Arrangement Earth Cable Type HICW Brass (standard), Nickel Plated Brass, 316L Stainless Steel with Neoprene Seal Range: -60 C to +100 C Two part armour clamp, single compression seal Electrical continuty using the armour wire termination (SWA, AWA) Single Wire Armour SWA and AWA Cable Type H1CX Braid Wire Armour, Pliable Wire Armour (PWA), Steel Tape Armour (STA) Kit Information Stand kit also available with a low smoke option. Use STD for Standard kit or LSF for low smoke Assembly Instructions AI 506 Features Simple robust 4 piece single compression cable gland Simple mechanical clamping arrangement for all SWA and AWA cable Ease of assembly High quality materials with exceptional anti corrosion properties UV stable seal Tested to the latest industrial standards Excellent sealing range EMC tested All hexagon parts are the same size Provides cable retention seal onto the cables Outer Sheath Note: Displacement or Compression seals do not prevent cold flow. IP seal required to maintain IP66. 9

CABLE GLAND TOUGHMATE MADE IN BRITAIN TM E1W 'L' Entry 'G' Approx (Fully Compressed Length) Armour/Braid 'C' 'T' Entry Thread Ø 'A' Ø 'B' A robust and simple dual compression cable gland for applications using SWA or AWA cable in a heavy industrial environment which is exposed to dust or extreme weather conditions. All cable glands can be supplied with a shroud, lock nut, serrated washer and an earth tag. Cable Gland Selection Table Cable Acceptance Details Entry Thread Size 'T' Inner Sheath A Outer Sheath 'B' Hexagon Dims. Standard Size Length of Steel Wire G Ref. NPT* Standard Standard Seal Alternative Seal (S) Across Across Thread (mm) Min Max or Option 'W' Flats Corners L Min Max Min Max Os M202 ½" 10 3.2 8.0 - - 6.5 16.0 0.8/1.25 50.0 24.0 26.5 O M202 ½" 10 6.5 11.9 - - 6.5 16.0 0.8/1.25 50.0 24.0 26.5 A M20 ¾" or ½" 10 10.0 14.3 9.0 13.4 11.5 20.9 0.8/1.25 51.0 30.0 32.5 B M25 1" or ¾" 10 13.0 20.2 9.5 15.4 17.0 27.2 1.25/1.6 55.0 36.0 39.5 C M32 1¼" or 1" 10 19.5 26.5 15.5 21.2 23.5 33.6 1.6/2.0 57.0 46.0 50.5 C2 M40 1½" or 1¼" 15 25.0 32.5 22.0 28.0 31.0 43.0 1.6/2.0 65.0 55.0 60.6 D M50 2" or 1½" 15 31.5 44.4/42.31 27.5 34.8 36.0 52.6 2.0/2.5 80.0 65.0 70.8 E M63 2½" or 2" 15 42.5 56.3/54.31 39.0 46.5 52.0 65.3 2.0/2.5 80.0 80.0 88.0 F M75 3" or 2½" 15 54.5 68.2/65.31 49.5 58.3 64.0 78.0 2.0/2.5 80.0 95.0 104.0 'T' - entry threads are 1.5mm pitch as standard. All dimensions in millimetres (except * where dimensions are in inches). 1 Smaller value is applicable when selecting reduced NPT entry option 2 Sizes Os and O are available with an M16 thread size. For O size with M16 thread, the maximum cable inner sheath diameter is 10.9mm Features Simple robust 5 piece dual compression cable gland Simple mechanical clamping arrangement for all SWA and AWA cable Ease of assembly High quality materials with exceptional anti corrosion properties Tested to the latest industrial standards Excellent sealing range EMC tested All hexagon parts are the same size Provides cable retention seal onto the cables Outer and Inner Sheath Low smoke and fume, zero halogen seals and shroud available Technical Data Construction and Test Standards BS EN 62444:2013 BS6121: Part 1 type E1W Ingress Protection IP66 IEC/EN 60529 Material Brass (standard), Nickel Plated Brass, 316L Stainless Steel with Neoprene Seal Operating Temperature Range: -60 C to +100 C Clamping Arrangement Two part armour clamp, dual compression seal inner and outer sheath Earth Electrical continuty using the armour wire termination (SWA, AWA) Cable Type Single Wire Armour SWA and AWA Kit Information Stand kit also available with a low smoke option. Use STD for Standard kit or LSF for low smoke Assembly Instructions AI 510 Note: Displacement or Compression seals do not prevent cold flow. IP seal required to maintain IP66. 10

TOUGHMATE CABLE GLAND 'L' Entry 'G' Approx (Fully Compressed Length) TM A2 MADE IN BRITAIN 'T' Entry Thread Ø 'A' A robust and simple design for applications using non armoured cable in a heavy industrial environment which is exposed to dust or extreme weather conditions. All cable glands can be supplied with a shroud, lock nut, serrated washer and an earth tag. Cable Gland Selection Table Cable Acceptance Details Entry Thread Size T Outer Sheath A Hexagon Dimensions Size Ref. Length of Thread Standard Seal G (mm) Across Flats Across Corners L Min Max 2K M16 10 3.2 8.0 23.5 19.0 21.2 Os M201 10 3.2 8.0 23.5 19.0 21.2 O M201 10 6.5 11.9 23.5 24.0 26.5 A M20 10 10.0 14.3 23.5 24.0 26.5 B M25 10 13.0 20.2 28.0 32.0 36.0 C M32 10 19.5 26.5 29.0 41.0 44.0 C2 M40 15 25.0 32.5 32.0 50.0 54.0 D M50 15 31.5 44.4 38.0 60.0 66.0 E M63 15 42.5 56.3 42.0 80.0 86.0 F M75 15 54.5 68.2 42.0 95.0 102.0 All dimensions in millimetres. T - metric entry threads are 1.5mm pitch as standard. 1 Sizes Os and O are available with an M16 thread size For O size with M16 thread, the maximum cable outer sheath diameter is 10.9mm Technical Data Construction and Test Standards BS EN 62444:2013 BS6121: Part 1 type A2 Ingress Protection IP66 IEC/EN 60529 Material Operating Temperature Clamping Arrangement Cable Type Brass (standard), Nickel Plated Brass, 316L Stainless Steel with Neoprene Seal Range: -60 C to +100 C Single compression seal Non armoured Kit Information Stand kit also available with a low smoke option. Use STD for Standard kit or LSF for low smoke Assembly Instructions AI 508 Note: Displacement or Compression seals do not prevent cold flow. IP seal required to maintain IP66. Features Provides a cable retention seal onto the cables outer sheath Simple robust single compression cable gland Ease of assembly High quality materials with exceptional anti corrosion properties UV stable seal Tested to the latest industrial standards Excellent sealing range Provides cable retention seal onto the cables Outer Sheath Low smoke and fume, zero halogen seals and shroud available 11

FIREMATE PRODUCTS 12

FIREMATE PRODUCTS Fight Fire With FireMate When you need to get people out safely, you need a system that can take the heat. The FireMate has been created to offer a complete connection and termination solution that will maintain its structural integrity, even in the harshest fire conditions. Tested to the latest fire standards including: BSEN50200:2006, BS8434-2:2003 + A2 2009, the range is ideal for overground and underground rail networks, commercial and public buildings. The Range The FireMate range of fireproof Connectors, Enclosures and Cable Glands provides a complete solution for use in escape route safety equipment, emergency lighting circuits, fire alarms, voice alarms, shutdown systems and fire detection. Wherever safety is imperative, choose FireMate. The FireMate Connector The original FireMate product has been developed with the rail industry to provide unparalleled strength in evacuation and rescue situations. Its unique fireproof rear intrumescent seal and high temperature pin and socket insert, ensure that it will maintain its structural integrity under the most severe conditions. Whether for underground or overground rail, marine safety or commercial and public building the FireMate is necessary wherever safety is critical. The FireMate EJB Enclosure Our toughest Enclosure range just got tougher. The Zinc Plated Mild Steel FireMate Enclosure range combines all the incredible strength and corrosion resistance of our best-selling EJB range with incredible fire-proof technology. For simple installation and superior strength the FM EJB is the ideal choice. The FireMate Cable Gland Range The FireMate range combines the Hawke s market-leading Cable Gland technology with rigorous in-house third party fire testing to ensure exceptional performance, even in the most severe conditions. Ideal for heavy industrial or critical safety environments which are exposed to harsh chemical, dust or extreme weather conditions the FireMate Gland range combines easy assembly with unparalleled strength to increase productivity and give you peace of mind when you need it most. 13

CONNECTOR FIREMATE MADE IN BRITAIN FIREMATE CONNECTOR The FireMate safety critical connector has been developed to be used on underground and overground rail networks, commercial and public buildings where it is critical for equipment to work during an evacuation and rescue situation. Tested to the latest fire standards BS EN50200:2006 and BS8434-2:2003 + A2 2009 our connector will maintain its electrical and structural integrity during the harshest of fire conditions. The product is designed to be used in escape route safety equipment; emergency lighting circuits; fire alarms; voice alarms; shutdown systems; fire detection. Technical Data Construction and Test Standards: BS5839-1 2013 section 26.2 e), BS EN50200:2006, BS8434-2:2003 + A2 2009, BS EN61984, BS5266-2016 -8.2.2 b d, GPSD (2001/95/EC) Ingress Protection: IP66 (Pending) Material: Nickel Plated Brass or Stainless Steel 316 Operating Temperature: Range: -25 C to +70 C Clamping Arrangement: Single compression seal Earth: Electrical continuty using earth pin and body connection Cable Type: Unarmoured fire rated cable Number of Cores: 4 + Earth Dali ready Core Size: Up to 6mm² Current range: 16 Amps Voltage range: 250 V Assembly Instructions AI 503 Max No. of make & break operations (EN61984): on and off load 500 Fire Test In accordance with BS EN50200:2006 (Resistance to fire with mechanical shock) Fire test: In accordance with BS 8434-2:2003 +A2 2009 (Resistance to fire with mechanical shock and water spray) 120mins at 830 (+40-0) C with mechanical shock and a rated voltage of 240v rms. 120mins at 930 (+40-0) C with mechanical shock and a rated voltage of 240v rms. (60 mins fire and shock and 60 mins fire, shock and water) Ordering Options Manufacture Hawke H Type FireMate FM Material Nickel Plated Brass N Stainless Steel S Connector Style The CP is always supplied with pin contacts FUSE pin Connector Plug CP Connector Receptacle CR Bulkhead Receptacle BR Besa Box Receptacle BB 3 Amp F3 5 Amp F5 10 Amp F10 15 Amp F15 Not Required or N/A for receptacle X Fuse pins are used as part of the standard wiring operation and will not meet the increased fire rating of this connector. Sample Order Code Manufacture/Type/Material etc H/FM/S/CP = Hawke, Firemate, Stainless Steel, Connector Plug. 14

FIREMATE CONNECTOR 2 3 FireMate Features 1 1. Unique fireproof rear intumescent seal to accommodate a wide range of cables. 2. Quick Connect via a 4 start thread Earth and Key location Screw. 3. Unique high temperature pin and socket insert. Integral moulded keyway to ensure fool proof assembly. Besa Box Receptacle to Connector Plug For Besa Box Mounting 49.5 65 75 70 35 23 Bulkhead Receptacle to Connector Plug For Enclosure/Equipment Mounting 49.5 46 75 70 23 45 M40 x 1.5 Connector Receptacle to Connector Plug For Inline Connections 49.5 44 75 70 23 17 66 61 Connector plugs and connector receptacles accept a cable OD of 11mm to 14.3mm. For any cable OD outside of these sizes, please contact Hawke Sales for more details. All bulkhead receptacles are supplied with an M40 entry. 15

ENCLOSURE FIREMATE MADE IN BRITAIN FM EJB FACE A Z Y Diameter 10mm T V FACE D W FACE B S INT / EXT EARTH V X FACE C M6 Int/Ext Earth 178 FM EJB1 FM EJB2 Dimension Size (mm) Size (mm) S 120 150 T 2 2 V 80.5 90.5 W 96 126 X 126 156 Y 96 126 Z 148 178 Terminal Type Conductor Size (mm2) Min. Maximum Quantity of Entries Per Face Thread Size M16 M20 M25 M32 M40 M50 Box Type FM FM FM FM FM FM FM FM FM FM FM FM EJB1 EJB2 EJB1 EJB2 EJB1 EJB2 EJB1 EJB2 EJB1 EJB2 EJB1 EJB2 Face A/C 6 10 6 8 3 3 2 2 2 2 0 1 Face B 4 8 4 6 2 2 1 2 1 2 0 1 Face D 6 10 6 8 3 3 2 3 2 2 0 1 Max. Terminal Capacity Max. Volts Max. Physical Terminal Content Terminal Qty Amps FM EJB1 FM EJB2 FM EJB1 FM EJB2 SAKK 4 0.5 6 275 5 9 20 20 Fire Test In accordance with BS EN50200:2006 (Resistance to fire with mechanical shock) Fire test: In accordance with BS 8434-2:2003 +A2 2009 (Resistance to fire with mechanical shock and water spray) 120mins at 830 (+40-0) C with mechanical shock and a rated voltage of 240v rms. 120mins at 930 (+40-0) C with mechanical shock and a rated voltage of 240v rms. (60 mins fire and shock and 60 mins fire, shock and water) Features Technical Data FireMate safety critical enclosures have been developed to be used on underground and over ground rail networks, and commercial and public buildings, where it is critical for equipment to work during an evacuation and rescue situation. Tested to the latest fire standards BS EN50200:2006 and BS8434-2: 2003 + A2: 2009 our enclosure will maintain its electrical and structural integrity during the harshest of fire conditions. The product is designed to be used in escape route safety equipment: emergency lighting circuits; fire alarms; voice alarms; shutdown systems; fire detection. Construction and Test Standards BS EN50200:2006, BS8434-2:2003 + A2 2009, GPSD (2001/95/EC) Ingress Protection IP66 to IEC/EN 60529 Material Zinc Plated Mild Steel Operating Temperature Range: -60 C to +80 C Assembly Instructions AI 297 Ordering information - please state the following; Box size, Terminal quantity/size, Gland entry quantity, Size/position For any further help with enclosure configuration please contact Hawke International 16

FIREMATE CABLE GLAND 'L' Entry 'G' Approx (Fully Compressed Length) Armour 'C' FM CW MADE IN BRITAIN 'T' Entry Thread Ø 'A' Ø 'B' A fire resistant, robust and simple design for applications using SWA or AWA cable in a heavy industrial, critical safety environment which is exposed to dust or extreme weather conditions. All cable glands can be supplied with a shroud, lock nut, serrated washer and an earth tag. Size Ref. Entry Thread Size 'T' NPT* Standard or Option Length of Thread (mm) L Cable Gland Selection Table Inner Sheath A Cable Acceptance Details Outer Sheath 'B' Min Max Armour 'C' G Hexagon Dimensions Across Flats Across Corners Os M202 ½" 10 8.0 6.5 16.0 0.8/1.25 49.0 24.0 26.5 O M202 ½" 10 11.9 6.5 16.0 0.8/1.25 49.0 24.0 26.5 A M20 ¾" or ½" 10 14.3 11.5 20.9 0.8/1.25 49.0 30.0 32.5 B M25 1" or ¾" 10 20.2 17.0 27.2 1.25/1.6 52.0 36.0 39.5 C M32 1¼" or 1" 10 26.5 23.5 33.6 1.6/2.0 60.0 46.0 50.5 'T' - metric entry threads are 1.5mm pitch as standard. All dimensions in millimetres (except * where dimensions are in inches). 2 Sizes Os and O are available with an M16 thread size. For O size with M16 thread, the maximum cable inner sheath diameter is 10.9mm Fire Test In accordance with BS EN50200:2006 (Resistance to fire with mechanical shock) Fire test: In accordance with BS 8434-2:2003 +A2 2009 (Resistance to fire with mechanical shock and water spray) 120mins at 830 (+40-0) C with mechanical shock and a rated voltage of 240v rms. 120mins at 930 (+40-0) C with mechanical shock and a rated voltage of 240v rms. (60 mins fire and shock and 60 mins fire, shock and water) Technical Data Construction and Test Standards BS EN 62444:2013 BS6121: Part 1 type CW Ingress Protection IP66 IEC/EN 60529 Material Operating Temperature Clamping Arrangement Earth Cable Type HICW Nickel Plated Brass with Intumescent Rubber Seal Range: -20 C to +70 C Two part armour clamp, single compression seal Electrical continuty using the armour wire termination (SWA, AWA) Single Wire Armour SWA and AWA Cable Type H1CX Braid Wire Armour, Pliable Wire Armour (PWA), Steel Tape Armour (STA) Kit Information Intumescent sealing material used for FireMate versions Assembly Instructions AI 505 Features Simple robust 4 piece single compression cable gland Simple mechanical clamping arrangement for all SWA and AWA cable Ease of assembly High quality materials with exceptional anti corrosion properties UV stable seal Tested to the latest industrial standards Excellent sealing range EMC tested All hexagon parts are the same size Provides cable retention seal onto the cables Outer Sheath 17

CABLE GLAND FIREMATE MADE IN BRITAIN FM E1W 'L' Entry 'G' Approx (Fully Compressed Length) Armour/Braid 'C' 'T' Entry Thread Ø 'A' Ø 'B' A fire resistant, robust and simple dual compression gland for applications using SWA or AWA cable in a heavy industrial, critical safety environment which is exposed to dust or extreme weather conditions. All cable glands can be supplied with a shroud, lock nut, serrated washer and an earth tag. Cable Gland Selection Table Cable Acceptance Details Entry Thread Size 'T' Inner Sheath A Outer Sheath 'B' Hexagon Dims. Standard Size Length of Steel Wire G Ref. NPT* Standard Standard Seal Alternative Seal (S) Across Across Thread (mm) Min Max or Option 'W' Flats Corners L Min Max Min Max Os M202 ½" 10 3.2 8.0 - - 6.5 16.0 0.8/1.25 50.0 24.0 26.5 O M202 ½" 10 6.5 11.9 - - 6.5 16.0 0.8/1.25 50.0 24.0 26.5 A M20 ¾" or ½" 10 10.0 14.3 9.0 13.4 11.5 20.9 0.8/1.25 51.0 30.0 32.5 B M25 1" or ¾" 10 13.0 20.2 9.5 15.4 17.0 27.2 1.25/1.6 55.0 36.0 39.5 C M32 1¼" or 1" 10 19.5 26.5 15.5 21.2 23.5 33.6 1.6/2.0 57.0 46.0 50.5 'T' - entry threads are 1.5mm pitch as standard. All dimensions in millimetres (except * where dimensions are in inches). Sizes Os and O are available with an M16 thread size. For O size with M16 thread, the maximum cable inner sheath diameter is 10.9mm Fire Test In accordance with BS EN50200:2006 (Resistance to fire with mechanical shock) Fire test: In accordance with BS 8434-2:2003 +A2 2009 (Resistance to fire with mechanical shock and water spray) 120mins at 830 (+40-0) C with mechanical shock and a rated voltage of 240v rms. 120mins at 930 (+40-0) C with mechanical shock and a rated voltage of 240v rms. (60 mins fire and shock and 60 mins fire, shock and water) Features Simple robust 5 piece dual compression cable gland Simple mechanical clamping arrangement for all SWA and AWA cable Ease of assembly High quality materials with exceptional anti corrosion properties UV stable seal Tested to the latest industrial standards Excellent sealing range EMC tested All hexagon parts are the same size Provides cable retention seal onto the cables Outer and Inner Sheath Technical Data Construction and Test Standards BS EN 62444:2013 BS6121: Part 1 type E1W Ingress Protection IP66 IEC/EN 60529 Material Nickel Plated Brass with Intumescent Rubber Seal Operating Temperature Range: -20 C to +70 C Clamping Arrangement Two part armour clamp, dual compression seal inner and outer sheath Earth Electrical continuty using the armour wire termination (SWA, AWA) Cable Type Single Wire Armour SWA and AWA Kit Information Intumescent sealing material used for FireMate versions Assembly Instructions AI 509 Note: Displacement or Compression seals do not prevent cold flow. IP seal required to maintain IP66. 18

FIREMATE CABLE GLAND 'L' Entry 'G' Approx (Fully Compressed Length) FM A2 MADE IN BRITAIN 'T' Entry Thread Ø 'A' A fire resistant, robust and simple design for applications using non armoured cable in a heavy industrial, critical safety environment which is exposed to dust or extreme weather conditions. All cable glands can be supplied with a shroud, lock nut, serrated washer and an earth tag. Entry Thread Size T Cable Gland Selection Table Cable Acceptance Details Outer Sheath A Hexagon Dimensions Size Ref. Length of Thread Standard Seal G (mm) Across Flats Across Corners L Min Max 2K M16 10 3.2 8.0 23.5 19.0 21.2 Os M201 10 3.7 8.0 23.5 19.0 21.2 O M201 10 6.5 11.9 23.5 24.0 26.5 A M20 10 10.0 14.3 23.5 24.0 26.5 B M25 10 13.0 20.2 28.0 32.0 36.0 C M32 10 19.5 26.5 29.0 41.0 44.0 All dimensions in millimetres. T - metric entry threads are 1.5mm pitch as standard. 1 Sizes Os and O are available with an M16 thread size For O size with M16 thread, the maximum cable outer sheath diameter is 10.9mm Fire Test In accordance with BS EN50200:2006 (Resistance to fire with mechanical shock) Fire test: In accordance with BS 8434-2:2003 +A2 2009 (Resistance to fire with mechanical shock and water spray) 120mins at 830 (+40-0) C with mechanical shock and a rated voltage of 240v rms. 120mins at 930 (+40-0) C with mechanical shock and a rated voltage of 240v rms. (60 mins fire and shock and 60 mins fire, shock and water) Technical Data Construction and Test Standards BS EN 62444:2013 BS6121: Part 1 type A2 Ingress Protection IP66 IEC/EN 60529 Material Operating Temperature Clamping Arrangement Cable Type Nickel Plated Brass with Intumescent Rubber Seal Range: -20 C to +70 C Single compression seal Non armoured Kit Information Intumescent sealing material used for FireMate versions Assembly Instructions AI 507 Features Provides a cable retention seal onto the cables outer sheath Simple robust single compression cable gland Ease of assembly High quality materials with exceptional anti corrosion properties UV stable seal Tested to the latest industrial standards Excellent sealing range Provides cable retention seal onto the cables Outer Sheath Note: Displacement or Compression seals do not prevent cold flow. IP seal required to maintain IP66. 19

Contact Details United Kingdom Hawke International Oxford Street West Ashton-under-Lyne Lancashire OL7 0NA Tel: +44 (0) 161 830 6695 Fax: +44 (0) 161 830 6698 Email: sales@ehawke.com Hubbell Scotland 388 Hillington Road Glasgow G52 4BL Tel: +44 (0) 141 882 9029 Fax: +44 (0) 141 883 3704 Email: info@hubbell-scotland.com U.S.A. Hawke International U.S.A. 4140 World Houston Parkway Suite 130 Houston TX 77032 Tel: +1 (281) 445 7400 Fax: +1 (281) 445 7404 E-mail: america@ehawke.com Middle East Hubbell Harsh & Hazardous, Dubai Airport Free Zone, Office #432, Building #6EB PO Box 23529 Dubai UAE Tel: +971 4 609 1222 Email: middle-east@ehawke.com Asia Pacific 130 Joo Seng Road #03-02 Singapore 368357 Tel: +65 6282 2242 Fax: +65 6284 4244 Email: asia@ehawke.com Korea 512 Hyosung Intellian 681-3 Deungchon Dong Kangseo-Gu Seoul 157-030 Korea Tel: +82 2 2063 3719 Fax: +82 2 2603 7386 Mob: +82 10 9977 6349 Email: yyu@hubbell.com.sg China Room H/I 18F No. 728 Pudong Avenue Shanghai International Ocean and Finance Building Shanghai 200120 P.R. China Tel: +86 (21) 3392 6550 ext. 317 Fax: +86 (21) 3392 6551 Mob: +86 139 1829 4175 Email: weiyi@hubbell.com.cn www.ehawke.com