MAKING MODERN LIVING POSSIBLE. Performer VSD. For Residential Applications - R410A. Quick reference

Similar documents
General Characteristics SM185S3QC. Dimensions. Terminal box. Electrical Characteristics. Recommended Installation torques

MAKING MODERN LIVING POSSIBLE. Technical description DHP-M.

One. Save time and money Streamline your heat pump business! makes a difference.

Revolutionary ETS Colibri valves Engineered to give you maximum flexibility and dependability

MAKING MODERN LIVING POSSIBLE. Wiring Diagram. DHP-iQ.

Danfoss Inverter scroll compressor, VRJ

Inverter scroll compressors VZH hybrid manifold

Inverter scroll compressors VZH hybrid manifold

Capacity controller for water chiller AK-CH 650

1+ SEER. 25% COP boost possible. Most valves expand your refrigerant EcoFlow expands your options. with silent defrost.

SonoSelect and SonoSafe energy meters

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

Danfoss Scroll for Refrigeration MLM / MLZ

Optimize your HVAC/R application with the right Danfoss components

Planning guide. Atec.

Technical description. Atec.

Danfoss scroll compressors SH- In parallel installation

R32. Plan now, for a smooth and profitable conversion. The countdown to R32 has begun! alternative.

Controller for operation of evaporator on water chiller EKD 316

Installation Guide. BasicPlus 2 WT-DR & WT-PR Room Thermostats

ATEX. Tough controls for tough environments. ia.danfoss.com. Brochure Controls. Danfoss controls - designed and approved for hazardous areas

Refrigeration and Air Conditioning Controls. User s manual. Degree Master Controller in AKC 55 Systems ADAP-KOOL REFRIGERATION AND AIR CONDITIONING

Instructions OP-LPHM & OP-MPHM OP-LPHM & OP-MPHM & OP-MPUM & OP-MPGM034

Installation Guide. DEVIreg 330 (-10 to+10 C) Electronic Thermostat.

SECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS

SECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS UNIT OBJECTIVES

PRODUCT RANGE: ROOFTOP PACKAGE

TEST REPORT #4. Travis Crawford Dutch Uselton. Lennox Industries Inc Metrocrest Drive Carrollton, TX 75006

food-retail.danfoss.com Overview Brochure ADAP-KOOL Evaporator Controllers Achieve best-in-class energy efficiency and food safety

DHP-H Varius Pro+/DHP-L Varius Pro+

Danfoss scroll compressors SM - SY - SZ

Performer scroll compressors. SM - SY - SZ Hz R22 - R407C - R134a - R404A - R507A. Selection & application guidelines

Refrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions

NE6210CZ NE6210CZ C O M P R E S S O R TECHNICAL SPECIFICATION HUANGSHI DONPER ELECTRICAL APPLIANCE CO., LTD

STACT. Model Designations. Model Number: STACT8S6. ST = Portable Scroll Chiller. AC = Air Cooled WC = Water Cooled. T = With Process Tank

Danfoss scroll compressors In parallel installation SM/SY/SZ

Reduce everything but reliability

TEST REPORT #43. System Drop-in Tests of Refrigerants L-41-1, L-41-2, and R-32 in Water-to- Water Heat Pump

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Danfoss scroll compressors SM SY SZ

Danfoss scroll compressors SH - In parallel installation

GP SERIES Packaged Chillers

70% Save time and money with MCHE standard products. MicroChannel Heat Exchangers. Lower refrigerant charge

Installation Guide. DEVIreg 610. Electronic Thermostat.

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Capacity regulators, type CPCE and LG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Hybrid tandem VSH with SH - R410A

80% leak risk reduction through fully hermetic coupling. Reduce lifecycle costs Increase savings and design freedom.

TRIDENT GS SERIES Central Chiller

TEST REPORT #14. System Drop-In Test of Refrigerant Blend ARM-42a in an Air-Cooled Screw Chiller

SonoSelect and SonoSafe energy meters

Refrigerants and lubricants

MAKING MODERN LIVING POSSIBLE. MLZ / MLM Refrigeration scroll compressors Hz - R404A - R507 - R134a - R22. Selection & application guidelines

MAKING MODERN LIVING POSSIBLE. One valve for all purposes. TGE - thermostatic expansion valves REFRIGERATION & AIR CONDITIONING DIVISION

Otherwise, you can continue reading the file on the following pages.

50% Refrigeration solutions to lower energy costs and reduce environmental impact. Foodservice Solutions. Up to

TEST REPORT #34. Compressor Calorimeter Test of Refrigerant DR-7 in a R-404A Scroll Compressor

4SCU16LS PRODUCT SPECIFICATIONS 16 SEER SPLIT SYSTEM TWO-STAGE AIR CONDITIONER COMPONENTS WARRANTY COMPRESSOR CABINET COILS DESIGN

80% leak risk reduction through fully hermetic coupling. Reduce lifecycle costs Increase savings and design freedom.

Tube-in-tube heat exchanger Type HE

DANFOSS OPTYMA PLUS INVERTER UNITS

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Installation Guide. DEVIreg 233. Electronic Thermostat.

MAKING MODERN LIVING POSSIBLE. Thermostatic expansion valves, type TR 6 REFRIGERATION & AIR CONDITIONING DIVISION.

DEVIreg 330 (+5 to +45 C) Electronic Thermostat

The full range of Evaporator Controls from ADAP-KOOL

Menu operation via AKM ADAP-KOOL. Compressor Pack Controller AKC 25H5. Software version 1.3x

condenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications

Installation Instructions NEMA-3R Cover Kit for D1h D2h VLT FC Series FC 102, FC 103, FC 202, and FC Description. 1.

MAKING MODERN LIVING POSSIBLE. Installation Guide. ECtemp 130. Electronic Thermostat.

Go Beyond Cool. coldroom.danfoss.co.uk. Danfoss Solutions for Cold Rooms Installers/Contractors, Europe. Over

Danfoss scroll compressors SH090 to SH485 - single

LONG LINE SET APPLICATION R-410A

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.

Danfoss scroll compressors SH090 to SH485 - single

Advance Split

Go Beyond Cool. coldroom.danfoss.com. Danfoss Solutions for Cold Rooms - Installers/Contractors, Europe. Over

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301

Air cooled industrial chillers

FHM-Cx Mixing Shunts for Floor Heating

Installation, Start-Up and Service Instructions

CHAPTER 6 CONDENSING UNITS

TEST REPORT #53. System Drop-in Test of Refrigerant Blend DR-55 in a Five-Ton R-410A Rooftop Packaged Unit

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

TEST REPORT #65. Compressor Calorimeter Test of Refrigerant L-41-2 (R-447A) in a R-410A Scroll Compressor

AVS Series Air Handlers Installation Manual for CLASSIC SERIES SYSTEMS Models SC, SD, and SDH

Tube-in-tube heat exchanger Type HE

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

INSTRUCTIONS P01-A Danfoss Commercial Compressors March 2006

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

ACMVTECH HIGH EFFICIENCY UNITARY AHU

Menu operation via AKA 21 ADAP-KOOL. Compressor Pack Controller AKC 25H5. Software version 1.3x

HRU Heat Recovery Unit

Capacity controller AK-PC 651

Temperature controller for limitation for the discharge gas temperature EKC 319A REFRIGERATION AND AIR CONDITIONING. Manual

RSG16**S1M. Split System Air Conditioner 16 SEER

FHM-Cx Mixing Shunts for Floor Heating

PWM expansion valves 2028

Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS

M P 1 2 F G C O M P R E S S O R TECHNICAL SPECIFICATIO N

Transcription:

MAKING MODERN LIVING POSSIBLE Performer VSD For Residential Applications R410A Quick reference

Introduction Performer VSD for residential applications developed by Danfoss is a complete age consisting of a dedicated variable speed compressor, variable speed drive, application controller, Electronic Expansion Valve (EEV), EEV controller and sensors. Three nominal system sizes are available (3, 4 and 5 tons), based on three compressor models. Components are set to be able to communicate using the Modbus RTU protocol. Communication details are available in the Modbus RTU communication setup manual. This quick reference document provides an overview, and the related code numbers for ordering, of different Danfoss components available to build a variable speed unit. 2 FRCC.EK.019.A2.22

Compressor capacities Conditions High SEER conditions (H) CHEER conditions Heat Pump conditions SEER conditions (I) Compressor model VRJ028 VRJ035 VRJ044 VRJ028 VRJ035 VRJ044 VRJ028 VRJ035 VRJ044 Nominal Tons 3 Tons 4 Tons 5 Tons 3 Tons 4 Tons 5 Tons 3 Tons 4 Tons 5 Tons Compressor speed Compressor capacity Compressor rpm Hz Btu/hr Ton isentropic efficiency 3600 60 36700 3.06 66.2 4200 70 42700 3.56 64.9 3600 60 46400 3.87 67.6 4200 70 53400 4.45 65.1 3600 60 57800 4.82 68.3 4200 70 68100 5.68 67.0 3600 60 36500 3.04 65.9 4200 70 42300 3.53 64.3 3600 60 46200 3.85 67.3 4200 70 53000 4.42 64.6 3600 60 57900 4.83 68.8 4200 70 68300 5.69 67.5 3600 60 25100 2.09 59.7 4200 70 29300 2.44 58.8 3600 60 31800 2.65 61.0 4200 70 36700 3.06 59.0 3600 60 40200 3.35 62.2 4200 70 47300 3.94 61.2 VRJ028 3 Tons 1800 30 21000 1.75 68.5 VRJ035 4 Tons 1800 30 26800 2.23 69.7 VRJ044 5 Tons 1800 30 34500 2.88 70.9 Conditions High SEER conditions (H) CHEER conditions Heat Pump conditions SEER conditions (I) Evaporating Temperature ( F) Condensing Temperature ( F) Superheat ( F) Subcooling ( F) 50 115 20 15 45 100 20 15 30 110 20 15 55 100 20 15 FRCC.EK.019.A2.22 3

Code number selection overview 3 Ton Single Industrial/ Multiple Returnable pallet Compressor Mounting hardware included 121U7003 No mounting hardware Variable speed drive EEV controller EEV valve EEV coil Suction pressure transmitter Discharge pressure transmitter 176L7000 080G1000 060G5706 060G5707 084N0003 Temperature sensor 3.5 m cable 1.5 m cable length, no length, no plug plug 121U7000 176L7004 080G1200 061L4202 061L4142 060G4526 060G4527 084N0027 080N0026 12 pcs 80 pcs 30 pcs 100 pcs 100 pcs 14 pcs 14 pcs 110 pcs 85 pcs 120U7002 16 pcs 4 Ton 5 Ton Single Industrial/ Multiple Returnable pallet Single Industrial/ Multiple Returnable pallet 121U7007 176L7001 080G1000 060G5706 060G5707 084N0003 121U7004 176L7005 080G1200 061L4203 061L4142 060G4526 060G4527 084N0027 080N0026 12 pcs 80 pcs 30 pcs 100 pcs 100 pcs 14 pcs 14 pcs 110 pcs 85 pcs 120U7006 16 pcs 121U7011 176L7002 080G1000 060G5706 060G5707 084N0003 121U7008 176L7006 080G1200 061L4203 061L4142 060G4526 060G4527 084N0027 080N0026 12 pcs 80 pcs 30 pcs 100 pcs 100 pcs 14 pcs 14 pcs 110 pcs 85 pcs 120U7010 16 pcs 4 FRCC.EK.019.A2.22

Conponents code number details Compressor Code number Nominal system Compressor Industrial Returnable Single capacity model pallet 12 pcs 16 pcs Mounting hardware included Mounting hardware included Mounting hardware not included 3 Tons VRJ028 121U7003 121U7000 120U7002 4 Tons VRJ035 121U7007 121U7004 120U7006 5 Tons VRJ044 121U7011 121U7008 120U7010 Single : The compressor is ed individually in a cardboard box. As far possible, Danfoss will ship the boxes on full pallets of 6 compressors. Mounting hardware for single are made of 4 rubber grommets + 4 assemblies of self tapping US thread bolts, washers and sleeves. Industrial : Compressors are not ed individually, but are shipped all together on one pallet. They can only be ordered by multiples of 12 compressors. Mounting hardware for industrial are made of 48 rubber grommets and 48 sleeves. Returnable pallet: Compressors are not ed individually, but are shipped all together on one pallet. They can only be ordered by multiples of 16 compressors. The empty pallet must be returned to the compressor factory. No rubber grommet, no sleeve delivered. Variable speed drive Code Number Nominal system Rated power Single Multiple capacity output 80 pcs 3 Tons 3.8 kw 176L7000 176L7004 4 Tons 5.3 kw 176L7001 176L7005 5 Tons 6.7kW 176L7002 176L7006 Supply voltage 208230V Mains frequency 60Hz, single phase EEV controller board Code number Nominal system Type Single Industrial capacity 30 pcs 3 Tons EIM316* 080G1000 080G1200 4 Tons EIM316* 080G1000 080G1200 5 Tons EIM316* 080G1000 080G1200 * : PCBA (printed on the board) code number : 080G1500 Power supply 24VAC/VDC (+/15%) FRCC.EK.019.A2.22 5

Conponents code number details EEV valves and coils Code number Nominal system EEV valve EEV coil capacity Industrial Industrial Type Type 100 pcs 100 pcs 3 Tons UKV18D147 061L4202 UKVA044 061L4142 4 Tons UKV25D146 061L4203 UKVA044 061L4142 5 Tons UKV25D146 061L4203 UKVA044 061L4142 Pressure transmitters Suction transmitter Discharge transmitter pressure (P0) pressure (Pc) Type Pressure range (bar) Single Code Number Industrial 14 pcs AKS32R 0 16 060G5706 060G4526 AKS32R 0 50 060G5707 060G4527 Pressure connection: 7/1620UNF (¼inch flare) Electrical connection: plug Pg9 EN 175301803 Temperature sensors Code number Type Single Industrial 110 pcs Industrial 85 pcs Single 3.5 m cable length 3.5 m cable length 1.5 m cable length 2.5 m cable length Evaporator outlet temperature sensor (S2) AKS11 084N0003 084N0027 084N0026 Discharge temperature sensor (Sd)* AKS11 084N0003 084N0027 084N0026 Ambient temperature sensor (S Amb.) AKS11 084N0003 084N0027 084N0026 Discharge temperature sensor (Sd)* AKS21 084N2007 For details and other code numbers available, refer to technical brochures. * : If an AKS11 is installed on discharge piping, contact between the PVC cable and the piping must be avoided (see picture). An AKS21sensor may be preferred. Its silicon rubber cable can be mounted directly to the discharge piping. Cable AKS11 Insulation material Discharge piping 6 FRCC.EK.019.A2.22

Components selection examples & Literature overview Example for Air conditionning unit For a 4 Tons A/C system, only one EEV and one EEV controller are necessary. The component selection would be as following: Component Code number Quantity Compressor VRJ035 121U7007 1 Variable Speed Drive 5.3 kw 176L7001 1 EEV controller 080G1000 1 EEV valve 061L4203 1 EEV coil 061L4142 1 Suction pressure transmitter (P0) 060G5706 1 Discharge pressure transmitter (Pc) 060G5707 1 Evaporator outlet temperature sensor (S2) 084N0003 1 Discharge temperature sensor (Sd) 084N0003 1 Ambient temperature sensor (S Amb.) 084N0003 1 Example for Heat pump unit (reversible system) For a 4 Tons reversible system, two EEV s and two EEV controllers are necessary. The component selection would be as following: Component Code number Quantity Compressor VRJ035 121U7007 1 Variable Speed Drive 5.3 kw 176L7001 1 EEV controller 080G1000 2 EEV valve 061L4203 2 EEV coil 061L4142 2 Suction pressure transmitter (P0) 060G5706 1 Discharge pressure transmitter (Pc) 060G5707 1 Evaporator outlet temperature sensor (S2) 084N0003 1 Discharge temperature sensor (Sd) 084N0003 1 Ambient temperature sensor (S Amb.) 084N0003 1 Literature overview Refer to following documents for detailed technical information, instructions and functionalities of the described components. Component Document type Document reference Compressor Selection & Application guideline FRCC.PC.019 Compressor Instructions FRCC.PI.012 Variable speed drive Installation and Operation Instruction MG10V102 Variable speed drive MODBUS RTU Communication Setup MG10U102 Manual EEV controller Engineering sheet EIM316 EEV valve & coil Technical leaflet PLRCA.PB.V1.A1.02 Temperature sensors and pressure transmitters Manual FRCC.ES.003 EEV controller Manual FRCC.ES.002 Trouble shooting Manual FRCC.ES.005 Field return procedure Manual FRCC.ES.004 FRCC.EK.019.A2.22 7

The Danfoss product range for the refrigeration and air conditioning industry Within refrigeration and air conditioning, Danfoss is a worldwide manufacturer with a leading position in industrial, commercial and supermarket refrigeration as well as air conditioning and climate solutions. We focus on our core business of making quality products, components and systems that enhance performance and reduce total life cycle costs the key to major savings. Controls for Commercial Refrigeration Controls for Industrial Refrigeration Electronic Controls & Sensors Industrial Automation Household Compressors Commercial Compressors SubAssemblies Thermostats Brazed plate heat exchanger We are offering a single source for one of the widest ranges of innovative refrigeration and air conditioning components and systems in the world. And, we back technical solutions with business solution to help your company reduce costs, streamline processes and achieve your business goals. member of: Danfoss A/S www.danfoss.com Danfoss Commercial Compressors http://cc.danfoss.com www.asercom.org Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. FRCC.EK.019.A2.22 Copyright Danfoss Commercial Compressors 02/2011