Engineering Data Air Purifiers

Similar documents
Engineering Data Air Purifiers

PHOTOCATALYTIC AIR CLEANER

EDAU Air Purifiers. Engineering Data MC70LPVM

Photocatalytic Air Purifiers. SiBE81-623A

BEFORE OPERATING, READ ALL INSTRUCTIONS IN THIS MANUAL CAREFULLY.

SiBE Service Manual. Photocatalytic Air Purifier L-Series

Comefresh CF-8608 Air Purifier

Table of Contents SAFETY FIRST. Owner s Manual. Safety Precautions Unit Specifications and Features Manual Operation (Without Remote)...

Owner s Manual Super-Slim Four-Way Cassette

NEXXOS INVERTER USER MANUAL

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

KSD-35 DR11 KUE-35 DVN11

Owner s Manual SPLIT-TYPE ROOM AIR CONDITIONER

Inverter Split-type Room Air Conditioner

WHYNTER Eco Pure Air Purifier

Owner s Manual CS

ROOM AIR CONDITIONER. Read This Manual. Before using your air conditioner, please read this manual carefully and keep it for future reference.

Owner s Manual. Fairwind Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

LOCK H M L REPLACE SLEEPING ANTI-POLLEN IONIZER UV-LAMP. User Manual

DAIKIN ROOM AIR CONDITIONER. Operation Manual

USER S MANUAL AQV09V A Series AQV12V A Series AQV18V A Series AQV24V A Series

CPG*CA CPG*CD CGC*CA CGC*CD CIM*CA CIM*CD CPP*CA CPP*CD

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Coway Air Purifier AP-1008DH

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

Air Purification System. Instruction Book CLI-AP20

DESCRIPTION OF THE APPLIANCE SAFETEY OPERATION CAUTION MAJOR COMPONENTS. Features

SPLIT TYPE. Instruction manual

ELECTRONIC AIR PURIFIER

AH1-CC-01 HEPA Air Purifier Operating Instructions

INVERTER SPLIT-TYPE ROOM AIR CONDITIONER

INDOOR UNIT/OUTDOOR UNIT

Coway Air Purifier AP-1008BH/CH

HEPA Air Purifier with Ion Flow Technology

OWNER S MANUAL KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11

SPLIT - TYPE ROOM AIR CONDITIONER

Register your product and get support at. AC4006. User manual

USE & CARE INSTRUCTIONS

INDOOR UNIT/OUTDOOR UNIT

Air Purifier OPERATION MANUAL

GMSG OWNER S MANUAL SPLIT-SYSTEM ROOM AIR CONDITIONER CONTENTS

IMPORTANT INSTRUCTIONS OPERATING MANUAL

Owner s Manual models HHPL & HHPM

INDOOR UNIT/OUTDOOR UNIT

Hand Dryer Installation & User Manual

INDOOR UNIT/OUTDOOR UNIT

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

Owners Manual Model: XXL

OWNER S MANUAL VMH 09/12/18/24

Register your product and get support at AC4002 AC4004. User manual

INDOOR UNIT/OUTDOOR UNIT

OPERATING MANUAL COOLING MODEL FUJITSU GENERAL LIMITED ROOM AIR CONDITIONER WALL MOUNTED TYPE. Indoor Unit AST9ASJCW AST12ASJCW

MULTI-SPLIT SYSTEM AIR CONDITIONER / HEAT PUMP. YN-M Series. Inverter++ Models. Two, Three, Four, and Five Zones (Dual, Triple, Quad, and Quint Multi)

Bosch Split-Type Ductless Air Conditioner / Heat Pump

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Register your product and get support at. AC4076. User manual

DAIKIN ROOM AIR CONDITIONER. Operation Manual. English. Deutsch. Français. Nederlands. Español. Italiano. Ελληνικά. Portugues. Русский.

INVERTER SPLIT-TYPE ROOM AIR CONDITIONER

BestAir. Instruction manual

OVHM80 Max Air Purifier

R410A SPLIT SERIES DC INVERTER QUICK COUPLING

INSTRUCTION MANUAL. Remember to register your air purifier at: Multi-Tech 8500 Air Purifier

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

OPERATING MANUAL. AIR CONDITIONER Duct Type. Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH PART NO KEEP THIS MANUAL FOR FUTURE REFERENCE

AIR PURIFIER MODEL NO: APA240 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: GC1114

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

Using the Remote Control Unit

Surgically Clean Air Inc.

Model & Replacement Pre-Filter Information Model Pre-Filter F Hunter Fan Company

Room Air Conditioners

AIR PURIFIER WITH GERMICIDAL UV LIGHT

SYSTEM Inverter Air Conditioners

INDOOR UNIT/OUTDOOR UNIT

BestAir. Instruction manual

Wall Mounted Mini Split Heat Pump Air Conditioner

OWNER S MANUAL. AIR CONDITIONER (SPLIT TYPE) For general public use Indoor unit RAS-10, 13, 18, 24, 30BKS-HK

CONTENTS CONTROLS 3-STAGE AIR PURIFICATION. X This product is suitable for 120V only. User Manual. Odor sensor. ➌ PlasmaWave

Reverse Cycle Split System Air Conditioner

OPERATION MANUAL. System Inverter Air Conditioners FXNQ20A2VEB FXNQ25A2VEB FXNQ32A2VEB FXNQ40A2VEB FXNQ50A2VEB FXNQ63A2VEB

INSTRUCTIONS Français 2 Nederlands 15 English 28 Italien

Operation Manual MODELS FTYN25DV3B FTN25DV3B FTYN35DV3B FTN35DV3B FTYN25DAV3B FTN25DAV3B FTYN35DAV3B FTN35DAV3B DAIKIN ROOM AIR CONDITIONER.

AH-PNX11 AU-PNX11 AH-PNX14 AU-PNX14 EN-1 SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL ENGLISH

SENA/09HF/IZ SENA/09HF/OZ SENA/12HF/IZ SENA/12HF/OZ SENA/18HF/IZ SENA/18HF/OZ SENA/24HF/IZ SENA/24HF/OZ

DEHUMIDIFIER OWNER S MANUAL. Read this manual carefully before operating the appliance and retain it for future reference.

Read this Safety Guide first.

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

WINIX AIR PURIFIER. User Manual. Tower XQ

FU-Z31E AIR PURIFIER OPERATION MANUAL PETUNJUK PENGOPERASIAN AIR PURIFIER. No. Reg. : 03/DJ-ILMEA/MG/I/2000. Free standing type Tipe Berdiri

Model: AW600. Triple Action Humidifier. Winix Inc. 120 Prairie Lake Road U nit E East Dundee, IL USA

SYSTEM Inverter Air Conditioners

CASSETTE TYPE. AUT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N KEEP THIS MANUAL FOR FUTURE REFERENCE AM PM

Washing Machine. User manual WW9*K5*****/WW8*K5*****/WW7*K5***** Untitled :17:40

OPERATION MANUAL. SYSTEM Inverter Air Conditioners FXSQ36MVJU FXMQ36MVJU FXSQ48MVJU. MODELS Ceiling-mounted Duct type. Ceiling-mounted Built-in type

VK-6008D. User Manual

WARNING VL-220CZGV-E. 1. Safety Precautions LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) Contents. Eng-1. English

OPERATION MANUAL. Humidifying air purifi er Floor Standing Type Ururu Air Purifi er. English. Deutsch. Français. Nederlands. Español.

MODELS FTX20J2V1B FTX25J2V1B FTX35J2V1B FTX20J3V1B FTX25J3V1B FTX35J3V1B DAIKIN ROOM AIR CONDITIONER. Operation Manual

OWNER S MANUAL. AIR CONDITIONER (SPLIT TYPE) For general public use. Indoor unit 42TVU010, 012, Outdoor unit 38TVU010, 012, ENGLISH

Transcription:

Engineering Data Air Purifiers Photocatalytic Air Purifiers

Air Purifiers MC704AVM 1. Introduction... 2 1.1 Features... 2 1.2 Performance... 3 1.3 Functions... 5 2. Precautions for Use... 7 2.1 Required Conditions... 7 2.2 Applicable Room Area...7 3. Specifications... 8 3.1 Specifications...8 3.2 Dimensions... 9 3.3 Wiring Diagram...9 3.4 Packaging Drawing...10 4. Operation Manual... 11 4.1 General Description...11 4.2 Safety Precautions... 12 4.3 Names and Operation of Each Part...13 4.4 Preparation before Operation... 15 4.5 How to Operate...17 4.6 Care and Cleaning... 18 4.7 Troubleshooting...22 5. Optional Accessories... 23 5.1 Titanium Apatite Photocatalytic Filter Roll...23 5.2 Wall-Hanging Kit...23 6. Troubleshooting... 24 6.1 Basic Inspection...24 6.2 Troubleshooting...25 7. Removal Procedure... 32 7.1 Removal of External Accessories...32 7.2 Removal of Ionizing Wire...34 7.3 Removal of Electrical Parts (Special Inverter Lamp)...35 7.4 Removal of PCBs...38 7.5 Removal of Fan Motor...42 Photocatalytic Air Purifiers 1

Introduction 1. Introduction 1.1 Features Concept In addition to the outstanding efficiency of basic operation, full of cutting edges of function! Powerful dust collection by large air flow (Air flow at HH mode : 420m /h) Deodorizing power 85% (Total removing ratio) Highly economical operation by "new roll filter" (Additional purchase is not required for 7years) Quiet operation (Operating sound level of 16 dba at LL mode is the quietest level in the industry) "Negative ion" generator is mounted to keep ion balance in the room air for comfort Compact design of the casing Fully flat type advanced appearance of front panel Features Top class! Improved Dust-collecting Performance Four-directional Suction Top class! Top class! Improved Deodorizing Power Quiet Operation Flat Panel Negative lons Child Lock Function MC704AVM Dirty air Daikin Filter System 4-layer system with photocatalyst and catechin for powerful bacteria and odor removal Plasma dust Collection Long-lasting 7-year Filter roll Purified air New Catechin pre-filter Plasma ionizer Front surface: electrostatic filter Photocatalyst 1st stage New Rear surface: antibacterial photocatalytic filter Photocatalyst 2nd stage Special inverter lamp 2 Photocatalytic Air Purifiers

Introduction 1.2 Performance A Negative Ion Negative ions are carried throughout the room with large air flow. One meter from the outlet vent 300,000 per cc B Corners of the room (approx. 12 m²) 12,000 per cc Negative ions are easily eliminated. Therefore the point is a large amount of negative ions! Typical amounts of negative ions at natural places. Forests approx. 2500 per cc Waterfalls approx. 10,000~18,000 per cc A B * Approx. 12 m². In HH mode Four-directional Suction Advanced Four-directional Suction! Even when the unit is operating on the floor, the newly designed four-directional air suction at the top of the unit exhibits superlative power. From all corners of the room, dust and odors are relentlessly sucked in from above, left, right, and front. Photocatalysis Special inverter lamp Surface coated with titanium oxide Light H CO ² O CO ² ² CO² H ² O Break down into water and carbon dioxide Verified decomposability for more than 52 toxic substances such as; Nitrogen oxide Ammonia Acetaldehyde When light strikes titanium oxide, hydrogen peroxide (H ² O ² ) and hydroxyl radicals (OH) are formed. These two substances possess powerful oxidizing properties and through mutual interaction they are able to decompose acetaldehydes and similar odorous substances into odorless carbon dioxide and water. Photocatalytic technology is also used in lots of other places. Toilets Tunnel illumination Hospitals and research labs Photocatalytic Air Purifiers 3

Introduction Long-lasting 7-year Filter Roll Annual filter replacement keeps deodorizing performance higher and assures hygiene. 1 2 Filter traps dirt and gradually gets soiled. An indicator illuminates when it's time for filter replacement. 3 Throw away the Tear off a soiled filter. replacement from the roll and fit it. Deodorizing Performance Deodorizing efficiency of filter Total removing ratio for the three odors of cigarette (%) 100 90 80 70 60 50 40 30 20 10 0 0 1 2 3 4 5 6 7 years 4 Photocatalytic Air Purifiers

Introduction 1.3 Functions High-power Turbo Mode Powerful dust-collecting performance & deodorizing with large air flow. High-power turbo mode High-power turbo mode is for quick air purifying and deodorizing when you need it, for instance after smoking. Pollen Mode High reputation! Make a whirl, catch pollen quick! Through spring to autumn, many kinds of pollen besides cider or cypress are scattered. Pollen mode Pollen mode makes it easy to catch pollen by changing the air flow setting. Easy Maintenance High reputation! Easy-clean flat panel One wipe, keep fine! Plasma ionizer Separable electrode plates! Filter roll Easy replacement! Keep spare filter clean! Photocatalytic Air Purifiers 5

Introduction A Variety of Convenient Functions Child lock function Even if a curious child handles the controller, the child lock ensures continued operation at the chosen settings. Remote controller storage slot Have you ever wondered where the remote controller has gone? In the new design, look for it in the storage space at the top of the unit. Easy to carry With one hand free it's easy to open doors and carry the unit from one room to another. Childproof display 6 Photocatalytic Air Purifiers

Precautions for Use 2. Precautions for Use 2.1 Required Conditions Ambient Temperature/Humidity Use this product under the following conditions. Operating conditions Room temperature 0 C - 32 C Room humidity 80% or less Use under other conditions may cause malfunction. Miscellaneous This product is for home use. Do not use for special purpose. This product is for indoor use only. Do not use in bathroom or outdoors as it is not water/condensation proof. Do not modify this product. 2.2 Applicable Room Area MC704AVM House less than 41m 2 Photocatalytic Air Purifiers 7

Specifications 3. Specifications 3.1 Specifications Model Regulation Power supply Type Front panel Color 2 MC704AVM NOTE: 1. Operating sound levels are the average of values measured at 1m away from the front, left, right and top of the unit. (This equal to the valve in an anechoic chamber.) 2. The side/bottom frames are black, and the rear frame is pearl white. CE 1φ 220 240 / 220 230V, 50/60Hz Photocatalytic air purifier Sparkling silver and metallic ocean blue Running current (HH/H/M/L/LL) A 0.46 / 0.26 / 0.19 / 0.16 / 0.15 Rated power consumption (HH/H/M/L/LL) Operating sound 1 (HH/H/M/L/LL) Fan Type Air flow rate (HH/H/M/L/LL) Driving method W 52 / 24 / 20 / 17 / 15 db 47 / 36.5 / 32 / 24 / 16 Multi blade fan m 3 /h 420 / 270 / 210 / 120 / 60 Direct drive Dust collecting efficiency % 95 (ASHRAE TEST) Filter Pre-filter Dust collecting element Catalyst Lamp Deodorizing filter High voltage power supply device Polypropylene screen with catechin Titanium apatite photocatalytic filter roll Plasma ionizer (electrostatic dust collection) + Titanium apatite photocatalytic filter roll Titanium oxide + Special inverter lamp Special inverter lamp, Wave length 365nm Direct current high voltage power supply Dimensions (H x W x D) mm 498 x 400 x 198 Package dimensions (H x W x D) mm 593 x 453 x 248 Product weight kg 7.0 Gross weight kg 9.0 Safety device Power cord Standard accessories Drawing. Front panel switch (safety switch) 2-wire 0.75mm 2 (2.5m) Operation manual, Wireless remote controller, Batteries, Titanium apatite photocatalytic filter roll 4D044118B 8 Photocatalytic Air Purifiers

PHOTOCATALYTIC AIR PURIFIER 1 2 4 Specifications 3.2 Dimensions MC704AVM Required installation space Air outlet grille 100. or more Signal Transmitter 11 8 500. or more 500. or more 90 52 1000. or more Air inlet grille 498 1000. or more Handles Dimension of remote control (ARC437A2) Air inlet grille Manufacturer's Label 3 400 3 198 10 Power supply cord Approx. 2.5m 3D038585A 3.3 Wiring Diagram MC704AVM Bz SW3 A1P A5P 1 CN1 6 SW3 BLK POWER SUPPLY PLUG 2(4) 1(3) 220-240V/220-230V 50/60Hz SET BLK BUZZER SAFETY SWITCH A2P A3P A4P A5P DUST SENSOR Fu1 FUSE (250V, 3.15A) M1F FAN MOTOR 6 A2P S1 1 6 PRINTED CIRCUIT BOARD (FOR POWER SUPPLY) PRINTED CIRCUIT BOARD (FOR INDICATION) PRINTED CIRCUIT BOARD (FOR SPECIAL INVERTER LAMP) PRINTED CIRCUIT BOARD (FOR HIGH VOLTAGE POWER SUPPLY UNIT) LED 5 LED 1 LED 2 SW3 BLK 3(1) 4(2) SET BLK LED 6 LED 3 LED 7 4 1LED 8 LED 9 LED10 LED11 A1P 3 S10 3 S8 1 3 Fu1 1 S9 S2 7 4 3 2 1 1 S7 10 10 LED24 LED12 POWER SUPPLY AC IN DC340V OUT DC15V OUT DC12V OUT GND 6 S3 1 NEGATIVE ION RED BLU BRN ORG WHT GENERATION PART 6 A4P BLK IONIZATION CN1 M1F M PART BLK GRN 6 1 SIGNAL RECEIVER SW1 1 10 S6 S4 1 2 INFRARED REMOTE CONTROL RED SW1 MAIN SWITCH LED8 LED (M : GREEN) LED18 LED (CLEANING OF IONIZATION PART: RED) SW2 FILTER RESET SWITCH LED9 LED (H : GREEN) LED19 LED (FILTER CUT OFF : RED) LED1 LED (DUST SIGN : GREEN) LED10 LED (TURBO : GREEN) LED20 LED (ODOR SIGN : GREEN) LED2 LED (DUST SIGN : YELLOW) LED11 LED (POLLEN : GREEN) LED21 LED (ODOR SIGN : YELLOW) LED3 LED (DUST SIGN : ORANGE) LED12 LED (CHILD LOCK : ORANGE) LED22 LED (ODOR SIGN : ORANGE) LED4 LED (DUST SIGN : RED) LED14 LED (NEGATIVE ION : GREEN) LED23 LED (ODOR SIGN : RED) LED5 LED (AUTO OPERATION : YELLOW) LED15 LED (CUT OFF TIMER (1HOUR) : YELLOW) LED24 LED (PHOTO OPERATION LAMP : BLUE) LED6 LED (LL : GREEN) LED16 LED (CUT OFF TIMER (2HOUR) : YELLOW) LED7 LED (L : GREEN) LED17 LED (CUT OFF TIMER (4HOUR) : YELLOW) LED14 LED15 LED16 LED17 LED23 LED22 LED18 LED21 LED19 LED20 SW2 Bz ODOR SENSOR te: 1. S, CN SHOWS A CONNECTOR. 2. SW SHOWS A SWITCH. 3. SYMBOLS SHOWS AS FOLLOWS RED : RED BLK : BLACK WHT : WHITE YLW : YELLOW GRN : GREEN BLU : BLUE A3P PNK : PINK BRN : BROWN RED 1 CN1 CN2 ORG : ORANGE PNK 1 WHT 3 PNK BLU 2 7 8 BLU LAMP ASSY (SPECIAL INVERTER LAMP) 3D038586C Photocatalytic Air Purifiers 9

Specifications 3.4 Packaging Drawing Photocatalytic filter roll Infrared remote control Product cover OPERATION MANUAL (attached to the back side) C:3P098535J 10 Photocatalytic Air Purifiers

Operation Manual 4. Operation Manual 4.1 General Description Contents Features... 1 Accessory... 1 Tips for Appropriate Use... 1 Specification... 1 Safety Precautions... 2 Names and Operation of each Part... 3 Preparation Before Operation... 5 How to Operate... 7 Care and Cleaning... 8 Trouble Shooting... 12 Tips for Appropriate Use When you want to remove house dust, setting up the air purifier in low rooms is effective. When you want to remove cigarette smoke, setting up the air purifier in high rooms is effective. If the air purifier is setup as shown below, the air circulation effect will be improved. When air conditioning the room, fluctuations in the room temperature are controlled while cleaning the air. Please select for the air to be spread all over the inside. Features 1 Photodecomposition, deodorization viral resistance Quick decomposition and elimination of smells 2 Plasma dust collection Effectively removes cigarette smoke and pollen 3 Negative ions The atmosphere in forests and around mountain streams is filled with negative ions, also known as vitamins of the air. This product will fill your living environment with the same negative ions. 4 7 year pre-cut Titanium apatite photocatalytic filter roll Tremendous advantage with durable filter 5 Designed for Quiet Operation Security when sleeping Accessory Confirm that accessory parts are in order. Specification Model Required power supply Outer dimensions Rated power consumption (W) Air flow rate (m³/h) Applicable room area Weight MC704AVM 1ø220-240/220-230V 50/60Hz 400 498 198 52/52 (Turbo) HH : Turbo 420/420 H : High speed 270/270 M : Standard speed 210/210 L : Low speed 120/120 LL : Quiet speed 60/60 less than 41m² 7.0 Titanium apatite photocatalytic filter roll (7 sheets / roll) Infrared remote control (Coin type battery CR2025 set included) Photocatalytic Air Purifiers 11

Operation Manual 4.2 Safety Precautions Safety Precautions Keep this manual where the operator can easily find them. Read this manual attentively before starting up the unit. For the reason of safety the operator must read the following cautions carefully. This manual classifies precautions into WARNINGS and CAUTIONS. Be sure to follow all precautions below: they are all important for ensuring safety. WARNING If you do not follow these instructions exactly, the unit may cause property damage, personal injury or loss of life. CAUTION If you do not follow these instructions exactly, the unit may cause minor or moderate property damage or personal injury. Never do. Never touch the air purifier (including the remote control) with a wet hand. WARNING Be sure to follow the instructions. Never cause the air purifier (including the remote control) to get wet. Do not use the power cable if it is damaged. Using a damaged power cable is extremely hazardous; if the power cord becomes damaged, you must obtain a replacement from the manufacturer or from a properly-authorized service agent. Do not disassemble, service or modify this equipment. Unwarranted tampering can lead to fire and/or malfunction. Do not operate with wet hands. Electric shock may occur. Do not use power supplies other than the rated supplies. Fire or electric shock may occur. Do not damage the electrical power cord, construct anything, or forcibly bend, stretch or twist the cord. Do not set heavy items on the cord or place the cord between items. If the electrical power cord is damaged, fire or electric shock may occur. Before changing filters, cleaning the equipment or moving it, turn it OFF and unplug the power cable. Working with power ON can lead to fire and/or electric shock. Do not use the power cable if damaged or loose in the socket. Using the power cable in anything but proper working condition can lead to short-circuits and subsequently electric shock and/or fire. Do not use in humid places or places which might be wet, such as bathrooms. Contact with water can lead to electric shock or damage the equipment. Do not use where oil components, such as machine oil, are floating around. There is the danger of cracking, electric shock or combustion. Toxic substances such as cigarettes (carbon monoxide) cannot be removed. CAUTION Do not use close to lighting equipment (within 1 m). The reception sensitivity of the remote control may be reduced and the color may change. Do not use outdoors or where exposed to direct sunlight. Direct sunlight can weaken remote control signal reception sensitivity and discolor the casing. Do not use near to sources of heat such as heaters. Heat can discolor and deform the casing. Keep the unit and remote control minimum 2 m from lighting, TVs, radios, stereos and aerials. This unit can disturb TV pictures and generate interference. Illumination can weaken remote control signal reception sensitivity and discolor the casing. When placed on top of a table, be sure to separate the rear of the unit from the wall by at least 10 cm. When used for long periods of time, the wall become dirty. Do not use in the place of kitchen fans or cooker hood fans. Adverse conditions of use can shorten service-life of the prelilter and ion filter, as well as lead to equipment damage. Prevent combustibles (hair sprays, etc.), sparks and incense from being drawn into the unit. Such substances can cause fire. Do not insert fingers or foreign objects into the inlet or outlet openings. Electric shock or damage may occur. There exists a danger of hands getting caught in the motor and causing injury. The appliance is not intended for use by young children or infirm persons without supervision. Young children should be supervised to ensure that they do not play with the appliance. When using pesticides of an indoor fumigation type (fume release), stop the operation of the air purifier to none of the chemical is sucked inside the unit. The chemical components will accumulate inside the unit and depending on your physical condition, you may react to the irritation which is bad for your health. When used in conjunction with a humidifier, keep mist from being directly drawn into the unit. Mists can lead to electric shock and/or equipment damage. Do not block the intake or outlet. Blocked openings can reduce capacity (air will not be cleaned throughout the entire room) and/or damage the equipment. Do not place any containers which hold water such as goldfish bowls or flower vases on or close to the unit. If water gets inside the unit, electric shock or malfunction may occur. Do not wipe with benzine or thinner, or spray with insecticide. Such substances can cause cracking, electric shock and/or fire. If not using the unit for long periods of time, unplug the power cable. Dielectric breakdown can lead to leakage current and subsequently electrical shock and or short-circuit may occur causing a fire. If the power plug is unplugged, be sure to hold and pull out the end of the power plug without holding the power cord. There is a chance that an electrical short or short-circuit may occur causing a fire. Do not operate with a pre-filter or Titanium apatite photocatalytic filter roll removed. Malfunction may occur. Do not sit on, stand on or shake the unit. Malfunction may occur. Do not use when the unit is on its side or leaning. Malfunction may occur. When using another burner at the same time, actively ventilate the area. This unit cannot remove carbon monoxide. If the ventilation is not sufficient, carbon monoxide poisoning may occur. Do not use in locations where there is a large amount of soot, such as a kitchen or locations where there combustible gas, corrosive gas or metallic dust is present. Fire or malfunction may occur. Select a strong wall or pillar when mounting the unit on a wall. A weak backing may cause the unit to fall. * Requires separately-sold wall-hanging kit. 12 Photocatalytic Air Purifiers

Operation Manual 4.3 Names and Operation of Each Part Names and Operation of Each Part Main unit Front Rear 1 4 5 7 8 10 13 9 11 12 14 15 11 11 18 3 16 16 17 NOTE 2 1 Front panel 2 Main unit display (Page 4) Shows operation status. 3 Knob for panel disassembly 4 Pre-filter Removes comparatively large material and dust. 5 Plasma ionizer Positively charges very small dust not collected in the pre-filter. 6 Titanium apatite photocatalytic filter roll receiver Unified with the plasma ionizer. 7 Opposing pole plate There are two, right and left, on the rear of the plasma ionizer. 8 Titanium apatite photocatalytic filter roll This filter is negatively charged and absorbs and removes positively charged dust particles using static electricity. 9 Photocatalyst This photocatalyst deodorizes and provides viral resistance using light of a special inverter lamp. 10 Special inverter lamp Light strikes the photocatalyst activating it. There are no effects on the human body. Photo operation (photocatalyst format) Light from the special lamp striking the photocatalyst deactivates bacteria and viruses by a strong oxidation action, thereby controlling infectiousness. Offensive odors such as cigarettes, garbage and exhaust gases (NOx) are also decomposed. (Toxic substances such as cigarettes (carbon monoxide) cannot be removed.) When first used, there is a possibility that a catalyst odor may be noticed coming from the outlet. This is normal. It will be decomposed during operation and go away at next use. 6 CAUTION Do not strongly press on the photocatalyst. The special inverter lamp located inside may be damaged. Do not remove the photocatalyst. Do not wash the photocatalyst in water. Do not look at the special inverter lamp directly for long periods of time. 11 Air inlet 12 Remote control storage slot Stores the accessory remote control 13 Handle Use when moving the main unit. 14 Air outlet 15 Negative ionization assembly Generates negative ions. Functions to combine positively charged toxic substances in a room and neutralize and transform them. If static electricity is applied, the amount of negative ions generated will be temporarily reduced. 16 Power supply cord hook Winds the power supply cord when storing the main unit. Do not wind the cord during operation. 17 Power supply cord 18 Wall-hang clasp attachment Photocatalytic Air Purifiers 13

Operation Manual Main unit display 3 4 5 6 10 11 12 13 7 8 9 1 2 15 14 1 Air intake for dust sensor Air is taken in from here and the dust sensor detects the dirty state of the air. 2 Clean monitor (Dust) Detects the dirty state of the air and indicates the results. Dust Indicator Off On Green Low Green Yellow High For the following case, only the green lamp is lit for the initial 7 seconds without regard to how dirty the air is. Operation directly after setting the front panel plasma ionizer Operation directly after inserting the power plug 3 Automatic operation indicator Lit during automatic operation. 4 Airflow rate indicator (Page 7) Lit by the set airflow rate setting. 5 Pollen mode / turbo mode indicator (Page 7) Lit during pollen and turbo mode. 6 Photo operation lamp (Page 7) Lit during photo operation. 7 Receiver Receives signals from the remote controller. 8 Operation switch / stop button Each time this button is pressed, the operation mode switches as shown below. (Automatic) (Stop) Green Green Yellow Yellow Orange Orange Red LL (Quiet) L (Low) M (Standard) (Pollen) HH (Turbo) H (High) * During automatic operation the airflow rate at that time will also be lit. 9 Child lock lamp (Page 7) Lit during child lock. 10 Negative ion mode indicator (Page 7) Indicates during negative ion operation. 11 OFF timer setting indicator (Page 7) Indicates the set OFF timer time. Indicates the time passed as well as the remaining time after the setting. 12 Clean indicator (Page 9) Flashes during cleaning period of plasma ionizer to notify that cleaning is necessary. 13 Titanium apatite photocatalytic filter roll / Replace indicator / Reset button When the replacement time for the Titanium apatite photocatalytic filter roll arrives, this lamp lights and if the time passes, it will flash. After replacement, press the reset button. (Page 9) 14 Air intake for odor sensor Air is taken in from here and the odor sensor detects the odor state. 15 Clean monitor (Odor) Detects changes to odors and indicates the results. Odor Indicator Off On Weak Strong Red Orange Orange Yellow Yellow Yellow Green Green Green Green Reactions to sudden temperature/humidity changes and odorless gas (carbon monoxide) may occur. There may not be any reaction for a uniform case without any changes to the intensity of the odor. There may be no reaction to pet odors or garlic odors. Different people have different sensitivity to odors so you may not notice an odor even though the lamp is green. For the following case, only the green lamp is lit for the initial 1 minute. This state is the standard value of the odor sensor sensitivity. Operation directly after setting the front panel plasma ionizer Operation directly after inserting the power plug 14 Photocatalytic Air Purifiers

Operation Manual 4.4 Preparation before Operation Preparation before Operation Remote control setup 1 Remote control preparations Battery is already set in the remote control but the remote control cannot be used as is without first preparing it. Use the remote control after pulling out the clear sheet from the battery cover. 2 Remote control storage When the remote control is not being used, you can store it in the remote control storage slot. Remote control Do not drop or place the remote control in water. (Damage may occur.) Do not press the remote control buttons with sharp objects. (Damage may occur.) The signals may not be received well of electronic lighting style fluorescent lamps (such as inverter fluorescent lamps) are in the same room. For these cases, discuss with the Daikin dealer. If other electrical device operate by the remote control, either separate them from the remote control or discuss with the Daikin dealer. Set the Titanium apatite photocatalytic filter roll WARNING Set the filter while the power supply plug is not plugged in. 3 Using the remote control Point the transmitter of the remote control towards the receiver of the main unit. If an obstruction to the signal, such as a curtain, exists, the remote control will not operate. The distance from which the remote control can transmit is approximately 6m. Receiver CAUTION The unit must be operated with a pre-filter and Titanium apatite photocatalytic filter roll set. If they are not set and the unit is operated, malfunctions may occur. 1. Remove the front panel. Hold the panel removal knobs (two locations, left and right) and pull the panel toward you raising it up. 4 Battery replacement 1. Open the cover on the rear of the remote control towards the arrow. 2. Replace the battery with CR2025 battery. (Be sure to set the battery with the + side of the cover as shown in the figure.) 3. Close the cover to its original position. NOTE Store the batteries where babies and children cannot reach them. If, by chance, a battery is swallowed, be sure to contact a doctor immediately. When discarding batteries, cover the terminals of the batteries with tape. If mixed with other metal or batteries, heat, explosion or combustion may occur. Bring the batteries to a nearby electronics store, watch store or camera store to recycle them. ATTENTION Battery The included coin type battery is prepared for initial use. They will be consumed within 1 year from the manufacturing date of the air purifier. A replacement target is approximately 1 year but if the reception becomes difficult, replace the batteries with new coin type battery CR2025. Coin type battery close to the recommended usage period may need to be replaced soon. In order to prevent malfunctions or injuries due to leaking or explosions, be sure to remove the coin type battery when the unit will not be used for a long period of time. Front panel ATTENTION Be careful not to scratch the front or damage the rear protrusions of the removed front panel. In particular, the rear protrusions function as a safety switch to turn OFF the power if the front panel is opened. If damaged, the unit will not operate. Handle Knob (2 locations, left and right) Rear side Protrusion 2. Remove the plasma ionizer. Hold the handle and pull the ionizer toward you raising it up. Photocatalytic Air Purifiers 15

Operation Manual 3. Install the Titanium apatite photocatalytic filter roll. (1) Cut off one piece along the perforation. 4. Install the plasma ionizer in its original configuration. Hole Titanium apatite photocatalytic filter roll Hole (2) Place the dark colored surface facing up and then correctly insert into the hooks (four) of the plasma ionizer. Titanium apatite Hole Hole Hook photocatalytic filter roll Dark colored surface 5. Mount the front panel to the main unit. (1) Hang the hooks (two) at the top of the front panel on the grooves of the top of the main unit. (2) Hold the panel removal knobs (two locations, left and right) and press into the main unit. Hook (2 locations) Hook (4 locations) CAUTION If the front surface and rear surface of the filer are mistaken, the performance will drop. (3) Store the remaining Titanium apatite photocatalytic filter roll in the Titanium apatite photocatalytic filter roll receiver. NOTE If the front panel is not correctly set on the main unit, the unit will not operate. Installation of main unit Follow the standards below during installation. <If installed on a table> Min. 100 cm ATTENTION The Titanium apatite photocatalytic filter roll can also be set without being cut. (1) Store the remaining Titanium apatite photocatalytic filter roll in the Titanium apatite photocatalytic filter roll receiver. Dark colored surface Titanium apatite photocatalytic filter roll Min. 50 cm Min. 10 cm Min. 50 cm Hole (4 locations) (2) Correctly insert into the holes (four) of the Titanium apatite photocatalytic filter roll into the hooks (four). Hole Titanium apatite photocatalytic filter roll <If installed on a wall> Ask your dealer for a wall-hanging kit (sold separately). NOTE If hanging the unit on a wall, make sure the wall is sufficiently strong and has a pillar behind it. ATTENTION If operated outside the conditions shown below, malfunction may occur. Indoor temperature 0-32 C Indoor humidity 80% or less Hook (4 locations) Hook 16 Photocatalytic Air Purifiers

Operation Manual 4.5 How to Operate How to Operate 9 2 4 7 1 3 5 6 8 7 When you want to decide a time to stop operation Press the [OFF TIMER] button. Each time it is pressed the timer setting switches as shown below. The remaining time will be lit in the OFF timer setting indicator. 1 (1 hour) 2 (2 hour) 4 (4 hour) (Cancel) When the set time is reached, the operation will automatically stop. The set time can be changed if the button is pressed while the timer is operating. 8 When you want to change the brightness of the photo operation lamp and clean monitors Press the [BRIGHTNESS] button. Each time it is pressed, the display will switch as shown below. 1 When operating Press the [ON/OFF] button. Pressing again will stop. 2 When you want to automatically switch the airflow rate Press the [AUTO] button. Automatically adjusts the airflow rate to LL (Quiet), L (Low), M (Standard), H (high) in response to the dirty condition of the air. 3 When you want to manually switch the airflow rate Press the [FANSPEED] button. Each time it is pressed the airflow rate switches as shown below allowing you to choose your desired flow. LL (Quiet) L (Low) M (Standard) H (High) The setting LL (Quiet) is a very slow airflow rate and is convenient when sleeping. 4 When you want to quickly clean the air Press the [TURBO] button. Pressing again will cancel. A high airflow rate will quickly remove any dirtiness in the air. This is convenient to use when cleaning. 5 When you want to remove pollen Press the [ANTI-POLLEN] button. Pressing again will cancel. Switching the airflow speed every 5 minutes between M (Standard) and L (Low) will catch pollen before they fall on the floor. 6 When you expel negative ions Press the [RELAX] button. Pressing again will cancel. Generates negative ions. (Dark) (Off) (Standard) Only set to OFF when you are concerned about light coming from the main unit such as when sleeping. The photo operation will stop simultaneous with the display going Off so if it is always Off, the odor removal and anti-bacterial performance will drop 9 When you want to prevent incorrect operation Press the [LOCK] button. Pressing again will cancel. Stops the function of the button other than the [LOCK] button on the main unit and buttons on the remote control. This makes it possible to prevent children from operating the unit incorrectly. When you want to release the child lock settings and the remote control is not in your hand, remove the power plug once and then reinsert it and operate the unit. When you want to operate the unit using the button on the main unit When the remote control is not in your hand, you can use the [Operation Switch / Stop] button on the main unit without using the remote control. (Page 4) NOTE Even if the ON/OFF button of the remote control is pressed within 2 seconds right after setting the front panel and plasma ionizer or inserting the power plug, the unit will not operate. When an incorrect operation is performed during operation If lightning or a radio signal cause an error indication to display in the main unit display and the remote control becomes inoperable, remove the power plug once and then reinsert it and operate the unit Photocatalytic Air Purifiers 17

Operation Manual 4.6 Care and Cleaning Care and Cleaning WARNING During maintenance you must stop the operation and remove the power plug from the electrical outlet. Electric shock or injury may occur. 3. Clean the pre-filter. After using a vacuum cleaner to remove any dust, clean with water. If it is very dirty, use a soft brush or a neutral cleaner to clean then dry well in the shade. CAUTION Do not wash the main unit with water. If water gets inside the unit, electric shock or malfunction may occur. ATTENTION Be careful not to scratch the front or damage the rear protrusions of the removed front panel.in particular, the rear protrusions function as a safety switch to turn OFF the power if the front panel is opened. If damaged, the unit will not operate. Rear side Protrusion CAUTION Do not dry at a location directly exposed to the sun. Do not clean with water hotter than 50 C. Do not burn with fire. Color changes or deformation may occur and the unit may become unusable. 4. Install the pre-filter in its original position. Match the lower edge of the pre-filter to the knob of the plasma ionizer and then insert the hole at the top into the protrusion of the plasma ionizer. NOTE If the front panel is not correctly set on the main unit, the unit will not operate. Cleaning the pre-filter Target is once every 2 weeks 1. Remove the front panel. Hold the panel removal knobs (two locations, left and right) and pull the panel toward you raising it up. Front panel Knob (2 locations left and right) Hole (6 locations) Protrusion (6 locations) 5. Mount the front panel to the main unit. (1) Hang the hooks (two) at the top of the front panel on the grooves of the top of the main unit. (2) Hold the panel removal knobs (two locations, left and right) and press into the main unit. Hook (2 locations) Hook (2 locations) 2. Remove the pre-filter. While holding down the plasma ionizer pull the upper portion toward you and lift it upward. Protrusion (6 locations) Hole (6 locations) Hook (2 locations) 18 Photocatalytic Air Purifiers

Operation Manual Care and Cleaning Replacing the Titanium apatite photocatalytic filter roll Replace the Titanium apatite photocatalytic filter roll when the Replace indicator (Page 4) is lit or flashes in the main unit display. Target is once every year. CAUTION The unit must be operated with a pre-filter and Titanium apatite photocatalytic filter roll set. If they are not set and the unit is operated, malfunctions may occur. Do not strongly press on the photocatalyst. The special inverter lamp located inside may be cracked. Do not remove the photocatalyst. Do not wash the photocatalyst in water. NOTE The replacement period differs depending on the use method and installation location. The replacement period will shorten if the unit is used where the air is dirty. 1. Stop the operation and unplug the power plug from the electrical outlet. 2. Remove the front panel. Refer to procedure 1 on Page 8. 3. Remove the plasma ionizer. Hold the handle and pull the ionizer toward you raising it up. Handle CAUTION If the front surface and rear surface of the filer are mistaken, the performance will drop. Store the remaining Titanium apatite photocatalytic filter roll in the Titanium apatite photocatalytic filter roll receiver. NOTE The Titanium apatite photocatalytic filter roll can also be set without being cut. (Page 6) For this case, you can also replace the filer as shown below. (1) Remove the Titanium apatite photocatalytic filter roll from Hook (4 locations) the hooks (four) and pull it out. Then correctly insert into the next Titanium apatite photocatalytic filter roll into the hooks (four). (2) Cut along the perforation 8. Install the plasma ionizer in its original configuration. 4. Remove the old Titanium apatite photocatalytic filter roll. 5. Take the Titanium apatite photocatalytic filter roll out from the Titanium apatite photocatalytic filter roll receiver. 6. Cut off one piece of the Titanium apatite photocatalytic filter roll along the perforation. Hole Hole Titanium apatite photocatalytic filter roll 7. Install the Titanium apatite photocatalytic filter roll. List up the dark colors of the surface and then correctly insert into the hooks (four) of the plasma ionizer. Hook Hole Hole Dark colored surface Hook (4 locations) Titanium apatite photocatalytic filter roll 9. Install the front panel to its original position. Refer to procedure 5 on Page 8. 10. Insert the power plug into the electrical outlet. 11. Press the reset button of the main unit display. Press using a thin pointed object to cancel the filter replace sign. (A beeping sound will be heard.) Cleaning the plasma ionizer Clean when the Clean indicator (Page 4) flashes in the main unit display. 1. Stop the operation and unplug the power plug from the electrical outlet 2. Remove the front panel. Refer to procedure 1 on Page 8. 3. Remove the plasma ionizer. Refer to procedure 3 on Page 9. Photocatalytic Air Purifiers 19

Operation Manual 4. Remove the Titanium apatite photocatalytic filter roll. 5. Remove the opposing pole plates (two). Push and expand the knobs on the outside and raise up the knob side of the opposing pole plates and then remove them on the outside. 7. Clean the plasma ionizer. Use water to slightly moisten the ionizing line and surrounding resin parts and then use a tissue to gently wipe along the ionizing line. Knob Knob Opposing pole plates (2) When cleaning be careful not to cut your hands on the opposing pole plates. (Wearing rubber gloves is safer.) ATTENTION The ionizing line is located at the rear of the opposing pole plates. When removing the plates, be careful not to catch and cut the ionizing line. Titanium apatite photocatalytic filter roll Opposing pole plate Ionizing line 6. Clean the opposing pole plates. After using a vacuum cleaner to remove any dust, clean with water. Ionizing line CAUTION When cleaning be careful not to cut your hands on the ionizing line. (Wearing rubber gloves is safer.) Be careful not to snag or cut the ionizing line. If the ionizing line is cut, request the Daikin dealer to replace it. If the unit is operated with the ionizing line cut, there will be no dust collection. The Clean sign may also flash. After cleaning, thoroughly dry the plasma ionizer. If the unit is operated before it is dry, the Clean indicator may also flash. 8. Set the opposing pole plates in the plasma ionizer (resin part). (1) Securely insert the opposing pole plates into the hooks (two at center) of the plasma ionizer. (2) While pressing and expanding the knobs (one on each side) of the plasma ionizer towards the outside, securely insert the opposing pole plates. (1) Hook (2) Knob If very dirty, clean using a neutral household cleaner or after applying the cleaner, rub with a rag or soft brush and sufficiently clean with water until no cleaning agent is left and then dry in the shade. ATTENTION Do not use water to clean the plasma ionizer (resin part). After cleaning, wipe with a cloth until none is remaining. Do not use acidic or alkaline cleaners. Rust may occur. Neutral cleaners Acidic cleaners Alkaline cleaners (2) Knob Opposing pole plate Plasma ionizer (Resin part) ATTENTION When removing the opposing pole plates, be careful not to catch and cut the ionizing line. 9. Install the Titanium apatite photocatalytic filter roll in its original position. Refer to procedure 7 on Page 9. 10. Install the plasma ionizer in its original configuration. Refer to procedure 8 on Page 9. 11. Install the front panel to its original position. Refer to procedure 5 on Page 8. 20 Photocatalytic Air Purifiers

Operation Manual Care and Cleaning Cleaning the front panel Clean as necessary When used in areas which are very dirty, the cleaning frequency will increase. Wipe off any dirt using a rag or wet tissue. If the dirt cannot be removed, wipe off using a rag soaked in a neutral household cleaner. ATTENTION Be careful not to scratch the front or damage the rear protrusions of the removed front panel. In particular, the rear protrusions function as a safety switch to turn OFF the power if the front panel is opened. If damaged, the unit will not operate. Do not use gasoline, benzine, thinner, polishing powder or light oil. Color changes or deformation may occur. Do not use a metal brush. Scratches may occur. Rear side Protrusion 3. Change the settings using the [Operation switch/stop] button of the main unit. Switches each time it is pressed. The settings is shown in the airflow rate indicator. Airflow speed display Dust sensor sensitivity L (Low) M (Standard) H (High) High (Sensor display becomes easy to light.) rmal (setting when shipped) Low (Sensor display will have difficulty coming on.) 4. When you decide on the settings, point the remote control at the main unit and press the [OFF TIMER] button. The receive sound will beep and the setting lamp will flash. 5. Unplug the power plug one time and then after 3 seconds or more plug it in again. This completes the settings. Cleaning the dust sensor Clean any dust clogging the air intake for the dust sensor. Clean using nozzles for small spaces of an electric vacuum cleaner. Airflow rate indicator Operation switch / stop button Air intake for dust sensor Sensitivity settings of the dust sensor The sensitivity of the dust sensor may worsen or become too sensitive. This is because the response time of the dust sensor differs depending on size of the room and installation location. For example, if installed at a low position in the room, the response for cigarette smoke will worsen. For this case, try installing the unit at a high position such as on a rack. If the response is still poor even though the installation location is changed, change the sensitivity of the dust sensor following the next method. 1. Press the [Operation switch/stop] button of the main unit for 10 seconds. 2. While pressing the [Operation switch/stop] button of the main unit point the remote control at the main unit and press the [OFF TIMER] button. The receive sound will beep and after L (Low), M (Standard) or H (High) flashes for approximately 5 seconds, a lamp will light corresponding to the currently set sensitivity. Off timer button NOTE If the operation of 5. is not performed, the unit will not return to normal operation mode. If the operation of 5. is performed, during the settings, the settings will not be correct. When the sensitivity is set high, it will become difficult for the sensor lamp to go out. Optional accessories Replacement Titanium apatite photocatalytic filter roll and the wall-hang kit are available at your dealer. Part name Replacement Titanium apatite photocatalytic filter roll Wall-hanging kit Part number BAC959A4 BKK959A4 Photocatalytic Air Purifiers 21

Operation Manual 4.7 Troubleshooting Troubleshooting Investigate the problem once again before requesting repairs. Case Check Measure Does not operate. The four airflow rate displays, LL (Quiet), L (Low), M (Standard) and H (High) are flashing at the same time. Air does not come out. Cleaning effect is not obtained. Television screen is distorted. During operation a crackling sound or a buzzing sound are heard. Odor is coming from the air outlet. Clean monitor (Dust) is red and does not change. Clean monitor (Dust) is green and does not change. Is the power plug unplugged? Is the front panel correctly set? Are the battery of the remote control dead? Is there any foreign matter in the air outlet? Is the unit installed at a location where the flow does not pass or are there obstructions close to the unit? Is there too much dust in the pre-filter or Titanium apatite photocatalytic filter roll? Is too much odors or smoke being generated? Is a television or radio installed within 2m of this unit or is an indoor antenna being used close to this unit? Is the power cord or antenna of the television or radio close to this unit? Is the plasma ionizer securely set? Is dust adhering to the ionizing line of the plasma ionizer (resin part)? Has water entered into the spurt hole moistening the negative ionization assembly? Is a large amount of odor being generated temporarily? (Many people smoking or grilling meat.) If the pre-filter or plasma ionizer dirty? Caused by dust clogging the inside of the dust sensor. Securely insert it. Securely set it. Replace with new battery. (Page 5) Remove the foreign matter. For other cases, contact a Daikin dealer. Remove the obstruction. Clean or replace. (Pages 8, 9) For this case, contact a Daikin dealer. Separate the television, radio and indoor antenna from this unit by 2m or more. Separate the power cord and antenna of the television or radio as much as possible away from this unit. Securely set it. Clean the plasma ionizer. (Page 9) If the negative ionization assembly is dry, the sound will go away. If operated, the odor will gradually go away. Clean it. (Pages 8, 9, 10) Remove the dust from the dust sensor air intake using nozzles for small spaces of an electric vacuum cleaner. If the dust is removed and the unit is manually operated for about half a day, it will be restored to a normal state. (Page 11) 22 Photocatalytic Air Purifiers

1 2 3 4 Optional Accessories 5. Optional Accessories 5.1 Titanium Apatite Photocatalytic Filter Roll BAC959A4 SPECIFICATIONS FILTER ELEMENT TARGET OF REPLACEMENT THICKNESS OF FILTER ELEMENT : 1.6 mm : NONWOVEN FABRIC SURFACE : ELECTROSTATIC PROPERTY REAR : TITANIUM APATITE PHOTOCATALYTIC PROPERTY : ABOUT 7 YEARS (1SHEET/YEAR 7SHEETS) (2400) (OVERALL FILTER LENGTH) 90 330 7 = 2310 φ 73 CORE 330 φ 25 (CORE) HOLE FILTER CL 330 (FILTER) 339(CORE) PERFORATION PERFORATION DETAIL OF FILTER ROLL 3D043734 5.2 Wall-Hanging Kit BKK959A4 232 163.5 131 HOOD 232 228 AIR REDIRECTOR 29.7 142 86 82 57.1 90 29 99 42 140 126 51.8 9 72 48 WALL INSTALLATION KIT 130 95.2 800 700 415 WALL PROTECTION SHEET 27 330 48 7 9-φ5HOLE 11.5 27 342 33 57 50 17 5.5 REMOTE CONTROL HOLDER INSTALLATION PANEL SCREWS : 1 pack TACKS : 4 INSTALLATION MANUAL : 1 3D044282 Photocatalytic Air Purifiers 23

Troubleshooting 6. Troubleshooting 6.1 Basic Inspection (1) Is the connector for the PCB plugged in? Or is there any poor connection? Good bye! Where are you going? Connect firmly! Broken! Pulled out! (2) Is the wire harness broken? Troubleshooting with Airflow Rate Indicator The airflow rate indicators flicker only when the DC fan is locked. The airflow rate indicators flicker simultaneously. 24 Photocatalytic Air Purifiers

Troubleshooting 6.2 Troubleshooting 6.2.1 Equipment does not operate, or operation lamps does not light. Caution 1 Models Covered 5 Troubleshooting MC704AVM Diagnosis Remedy 2 Method of Malfunction Detection Be sure to turn off power switch before connect or disconnect connector, or parts damage may be occurred. Is operation possible with remote control? Is operation possible with ON/OFF switch? ON/OFF switch (Operation switch /stop button) (Cannot operate with ON/OFF switch on unit) (Cannot operate with remote control) *Release child lock. Replace ON/OFF switch cover. (Replace display PCB). Go to 6.2.2. Remote controller sends signals erratically. 3 Malfunction Decision conditions 4 Supposed Causes The safety device is activated due to poor assembly of the panel. Front panel switch is defective. The unit is not turned on. Unspecified voltage is used. The battery for the remote controller is exhausted. Is AC cord plugged in? Or is breaker "ON"? Do other appliances operate? Is rated voltage within ±10%? Remove panel. Is protrusion on the rear panel damaged? Is there power failure? Is 220-240V supplied? Plug in AC cord. Set breaker to ON. Wait for power restoration. When unspecified voltage is applied. Replace power supply PCB. (Varistor or fuse may be damaged.) Contact power company. Replace panel. *Protrusion on front panel switch Rear side Front panel switch operation check Press front panel switch with a thin stick, then press ON/OFF switch after 5 seconds. Front panel operation lamp light? Protrusion Replace panel (front panel switch is not securely mounted due to deformity). Go to 6.2.4. PCB is defective. Photocatalytic Air Purifiers 25

Troubleshooting 6.2.2 Remote controller sends signals erratically. Caution Be sure to turn off power switch before connect or disconnect connector, or parts damage may be occurred. 1 Models Covered 5 Troubleshooting MC704AVM Diagnosis Remedy *Release child lock. Is battery correct? (2.5V or more?) Replace battery. 2 Method of Malfunction Detection Check if infrared signal is sent from remote control. (Check with an infrared checker.) Is signal properly transmitted? Replace remote controller. 3 Malfunction Decision conditions Check remote control for normal operation. You can operate with ON/OFF switch on the unit, but not with remote controller. Can you operate with another remote control? Replace remote controller. Check installation environment. 4 Supposed Causes Remote controller battery is exhausted. Remote controller is defective. Display PCB is defective. Malfunction is caused by inverter fluorescent lamps. Is there any inverter fluorescent lamps around the unit? Replace display PCB. Replace panel. Or change installation location. 26 Photocatalytic Air Purifiers

Troubleshooting 6.2.3 Sensor LED remains lit. Caution Be sure to turn off power switch before connect or disconnect connector, or parts damage may be occurred. 1 Models Covered 5 Troubleshooting MC704AVM Diagnosis Remedy <Dust sensor unit LED> Remove dust sensor unit. 2 Method of Malfunction Detection Keep holding down front panel switch and press ON/OFF switch. Does LED remain it? Replace display PCB. Replace dust sensor unit <Odor sensor LED> Check ambient humidity. 3 Malfunction Decision conditions 80%RH or less? Wait a while, then check again. It is not malfunction. The sensor is detecting moisture in the air. Change the installation location. Reset the power. 4 Supposed Causes Display PCB is defective. Dust sensor unit is defective. Does LED remain it? Replace display PCB (Sensor is defective). It is not malfunction. The sensor may be operating as room is oversized or open. Photocatalytic Air Purifiers 27

Troubleshooting 6.2.4 PCB is defective. Caution Be sure to turn off power switch before connect or disconnect connector, or parts damage may be occurred. 1 Models Covered 5 Troubleshooting MC704AVM Diagnosis Remedy Remove panel. 2 Method of Malfunction Detection Is there 12V DC between JP14 and GND while holding down front panel switch? Replace display PCB. Are connectors off? Plug in connectors. 3 Malfunction Decision conditions Replace power supply PCB (including damaged varistor or fuse). Or replace front panel switch. 4 Supposed Causes Connector is off. Display PCB is defective. Power supply PCB is defective. Front panel switch is defective. 28 Photocatalytic Air Purifiers