MME Standard Operating Procedure (SOP)

Similar documents
MME Standard Operating Procedure (SOP)

Laser Safety Management

Laser Safety Part III Administration

Laser Safety Part III Administration

LASER SAFETY BARRIER

DUQUESNE UNIVERSITY. Laser Safety Program

Directive on Laser Safety. NRC Occupational Safety and Health Manual

Approved by Principal Investigator: Date: Approved by Laser Safety Officer: Date:

Laser Safety. This Laser Safety Program applies to the acquisition, use, transfer, and disposal of all Class 3B and 4 lasers at UNC Asheville.

Approved by Principal Investigator: Date: Approved by Laser Safety Officer: Date:

North Dakota State University Laser Safety

Laser Use at Subaru Telescope (NAOJ) Laser Safety Policy

Hazard Analysis, Mitigation, and Operating Procedures for (Laser name) Laser

Laser Use Authorization

A. Administrative. B. Labeling and Posting. C. Control Measures. Laser Safety Self-Audit Checklist. Building Room Principal Investigator Date

Inspection Detail. General Questions for Laser Labs

University of California Santa Barbara Department of Chemistry and Biochemistry Optical Characterization Facility. Safe operations manual

Laser Use Registration & Application (L.U.R.)

NEED FOR LASER SAFETY

Laser Safety Self-Audit Checklist

Rutgers Environmental Health and Safety (REHS)

Laser Safety. Standard Operating Procedure (SOP)

Laser Safety and Regulations Division of Physics and Applied Physics, School of Physical and Mathematical Sciences Nanyang Technological University

PURPOSE OF THE PROCEDURE

Recommended Work Area Controls

LASER SAFETY. Class 2 and 2a - low power, low risk Class 2 and 2a lasers have low power and emit visible light. They will cause harm if viewed

*For inquiries and questions about lasers, see the Yellow-Page.

Laser Standard Operating Procedure

Information for Proper Posting & Laser Area Sign Templates

Laser Safety. Occupational Health and Safety

LASER SAFETY PROGRAM

Lessons Learned Events at SLAC. Mike Woods, SLAC National Accelerator Laboratory

Laser Safety Citations

Laser Class 4 Laser Type Nd-YAG Laser Manufacturer New Wave Research Laser Model SoloII-30 PIV Laser Serial / Id # Serial number 16582

Laser Safety Program Manual

PART V: WORKING WITH LASERS

Preface. Consult the current Laser Safety Officer at for specific information.

Contact Information. Procedure Title. Procedure Author

University of North Florida Laser Safety Manual. Environmental Health and Safety Department

Laser & Ultraviolet Light Sources Safety

OCCUPATIONAL SAFETY AND ENVIRONMENTAL HEALTH GUIDELINE

Stony Brook University Hospital Environmental Health & Safety Policy & Procedure Manual. EH&S 6-8 Original : 1/00 Revision Date: 3/16/15 Pages 6

Title: Laser Safety Effective Date: 9/91 Revision: 2/97 Number of Pages: 7

Control Considerations for Safe Laser Alignment

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

Western Carolina University Laser Safety Manual

Laser Registration Requirements: EH&S must be notified after the purchase any class 3B or 4 lasers through the online Laser Registration Form.

CALIFORNIA INSTITUTE OF TECHNOLOGY LASER SAFETY MANUAL. January, 1998

FOCUS ON LASERS. Philip Campbell RADIATION SAFETY: Principles, Practice, and Emerging Issues March 2018

Content. Laser physics Laser treatment parameters Laser safety. by Fotona d.o.o., 2017

Laser Safety Training

Copyright 2017 by Lasermate Group, Inc.. All rights reserved.

INSTRUCTIONS: Insert your laboratory-specific information at yellow highlighted locations. Laser Safety Manual

Rice University Laser Safety Manual

This slide presentation has been prepared for Temple University Health System and is intended only for use by it s faculty, staff and students.

Laboratory Safety Audit

Staying Safely on Target! Laser Safety. Chuck Paulausky, CHMM, LSO

All personnel working in experimental areas at Jefferson Lab must have completed the EH&S Orientation at Jefferson Lab.

SYRACUSE UNIVERSITY S LASER SAFETY PROGRAM

Laser Safety Training Guide

The Laser System Supervisor (LSS) is John Hansknecht. Extension: 7096

Laboratory Safety Audit

West Virginia University Laser Safety Program

Laser Safety Manual. for. Bowling Green State University

Laser Cutting Machine Safety Guide (For employers and employees)

Laser Safety Program Manual. Updated: 2017 Environmental Health and Safety

LASER SAFETY PLAN OPHTHALMOLOGY

Sample Laser Safety Operating Procedure (LSOP) Standard Operating Procedures for the High Watt laser

ENVIRONMENTAL HEALTH AND SAFETY STANDARD OPERATING PROCEDURES

Why is Laser Safety Important Laser usage is growing rapidly e.g. laser points, CD/DVD, industrial applications Heavy use now in laboratories for

Laser Safety Program

Local Rules for the Use of the Raman Spectroscopy Lab

Why is Laser Safety Important Laser usage is growing rapidly Industrial applications Heavy use now in laboratories for research, analysis Many

AUBURN UNIVERSITY LASER SAFETY STANDARD OPERATING PROCEDURES

Lasers and Laser Safety

PROCEEDINGS OF SPIE. ANSI laser standards, education (Z136.5), research, development or testing (Z136.8)

Policy Redesign Project. Laser safety. Table of Contents

Laser Safety Policy Statement...2 Laser Safety Program...2 Related Laser Safety Program Documents... 2 Additional Resources... 2

The George Washington University. Laser Safety Manual

Laser Safety Manual Wanda Daley Drive Ames, Iowa (515) Copyright

American National Standard

Laser Safety. The George Washington University Office of Laboratory Safety Ross Hall, Suite B

Departmental New Employee Safety Orientation

Radiation and Laser Safety

Laser Safety Orientation. Laser Safety Administration

LASER SAFETY TRAINING CATALOG LASER INSTITUTE OF AMERICA S MAKE LASER SAFETY YOUR PRIORITY LASER

LABORATORY CHEMICAL HYGIENE AND SAFETY PLAN

HARDWOOD INDUSTRY FACILITY & SAFETY INSPECTION CHECKLIST

The University of Mississippi BASIC LASER SAFETY

2018 DOE Laser Worker Survey Results. Matthew Quinn 12 th DOE LSO Workshop 9 May 2018

WORKPLACE INSPECTION CHECKLIST FOR LABORATORY ENVIRONMENTS

LASER INTERFEROMETER GRAVITATIONAL WAVE OBSERVATORY - LIGO - CALIFORNIA INSTITUTE OF TECHNOLOGY MASSACHUSETTS INSTITUTE OF TECHNOLOGY

Light fright. Improper laser use poses real safety hazards

Local Rules For Working with Lasers AUGUST V 1.3 (Reviewed April 2015)

American National Standard for Safe Use of Lasers

Class 1 laser beam sensor safe for your eyes

Bioenvironmental Engineering Site Assessment I

UC IRVINE LASER SAFETY PROGRAM

UNIVERSITY OF KANSAS LAWRENCE CAMPUS

McGill University 1/10/2013

Transcription:

MME Standard Operating Procedure (SOP) Name Femtosecond Laser Description Coherent Legend Elite, Ultrafast Amplifier Laser Systems Location E3-2168 SOP Creation Date 2015-03-08 SOP Created By Paola Russo SOP Revision Date SOP Revised By SOP Location E3-2168 Manual Location E3-2168 Equipment Owner Dr. Norman Zhou Authorized Trainers Paola Russo Support Technicians Robert Letiecq (Coherent) Staff Service Engineer Tech support: 800-367-7890 Robert.Letiecq@coherent.com Significant Hazards Exposure to laser beam and laser reflections (Vision protection) Laser irradiation to eye Laser radiation (wavelengths: 800 nm) Eyes and Skin hazards o Thermal (heat build-up from absorbed laser light) o Photo-chemical (photon energy sufficient to cause bond breaking) Laser hazards to the eye o Visible and near IR (400 to 1400 nm) o Absorbed at retina o Blind spots o Optic disk > total blindness o Fovea > central vision o Macula > color vision o Degraded color vision o Degraded night vision Laser hazards to the skin (Visible to near IR) o Penetrates partially through skin o Deep burns Non-beam hazards o Fire and explosion (class 4 lasers able to ignite combustible materials >> keep production area clean) o Compressed gases o High pressure vessels o Valve failure Noise (Lasers, chillers, are all noise sources) MME SOP Template v.2013.05.17 Page 1 of 9

Administrative Controls Instrument can be used independently at any time by a trained and authorized student or an employee. Authorized personnel: Paola Russo, Ming Xiao (x. 35625). Only authorized personnel shall operate, maintain or service the laser. Alignment procedures shall ensure that the MPE for the eye is not exceeded. Eye protection shall be required (NOTE: Different googles are available according to the wavelength of the laser that is in use: o Thorlabs LG9= 800 nm to be used with the femtosecond laser o Laser vision P5B02=OD2=532 nm for alignment of mantis o Laser vision T5E06= OD7= 190-565nm; OD=6 565-578nm when using TOPAS at lower wavelength o Laser vision T5K07=OD7+=532nm;OD3+=850-900nm;OD4+=900-950nm;OD5+=950-1000nm; OD7+=1000-1600nm;OD5+=1600-2400nm;OD5+=2900-10600nm Black curtains in lab to protect external exposure of laser beam Spectators are not allowed to enter the laser room. Service personnel shall comply with control procedures. Students need to register previously before usage Students/ Employee should be monitored by the authorized trainer if the training is not complete or the authorized trainer believes that supervision is required during the experiments Authorized Trainer frequently visit the lab to observe the safety operation of the instrument Engineering Controls Entryway (door) interlocks (To be installed) Warning signs A removable beam damp is placed at the laser output during the laser warm-up stages. (To be Installed) Warning light is used during use or start-up of the laser. Aluminum shields to contain the laser path The controlled areas are: o restricted to authorized personnel only o equipped with a device that allows for deactivation of the laser (to be installed) o designed to fulfill Class IV controlled area requirements o designed with entry safety controls (to be installed) MME SOP Template v.2013.05.17 Page 2 of 9

PPE Required Goggles to protect the eyes from laser beam exposure (for different laser beams) Eye Protection Different eyewear goggles are available at the entrance of the laser room. (See table for goggles specifications) Brand and Model Wavelength(s) or wavelength range (nm) Eyewear optical density required Total Number Thorlabs LG9 (Femtosecond laser) 180-400 720-1090 750-1064 6+ 5+ 7+ 4 Laser vision P5B02 (Mantis Alignment) 532 2 2 Laser vision T5E06 (For maintenance operation of femtosecond laser and when using TOPAS at lower wavelength) 190-565 565-578 7 6 2 532 7+ Laser vision T5K07 (TOPAS at longer wavelength) 850-900 900-950 950-1000 3+ 4+ 5+ 2 1000-1600 7+ 1600-2400 5+ 2900-10600 5+ Factors in selecting appropriate eyewear: o Wavelength(s) of laser output o Optical density requirement of eyewear filters at laser output wavelength Visible light transmission requirement and assessment of the effect of the eyewear on the ability to perform tasks while wearing the eyewear Skin Protection Gloves are available in the laser room to wear during laser operation and materials handling. MME SOP Template v.2013.05.17 Page 3 of 9

Relevant Standards and Codes The guidance on best practice in the use of lasers is given in: o ANSI Z136.1 American National Standard for Safe Use of Lasers o IEC 60825-1 Safety of laser products Part 1: Equipment classification and requirements. o CAN/CSA E 60825-1 o U. S. O. S. H. A. regulations o U. S. CDRH Laser product performance requirements o Ontario Ministry of Labour follows ANSI Z136.1 o ANSI Z136.1 American National Standard for Safe Use of Lasers o Maintained and published by Laser Institute of America (www.laserinstitute.org) o Principle U. S. laser safety standard for laser users o Goal: to harmonize with international (IEC) standard o Changes for the 2007 version of the ANSI Z136 standard o Changes to classifications (harmonize with IEC specs.) o Increase duties of Laser Safety Officer Relevant MSDS Compressed gas cylinders Oxygen and Argon Metal target: o Titanium o Silver o Nickel o Copper Accident Procedure Response/Reporting procedures All accidents/exposures are to be reported to supervisor as soon as possible. Serious Injury/ Illness: Eye injuries, skin injuries Call 911 or proceed immediately to the UW Hospital Emergency Department. All Other Injuries: For treatment of all other injuries, proceed to: o Department/Residence first aid kit / station location E3 2108H o Health Services first aid services available 519-888-4096, X. 84096 o UW Police assists if the above services are not available 519-888- 4911, X. 22222. Also see safety posters in the lab. MME SOP Template v.2013.05.17 Page 4 of 9

Emergency Shutdown Procedure Personnel Injury: o Turn off the laser system by pressing the delay off buttons, the delay keys on SDG box and turn off Amplifier from the software on the PC, shut down mantis power unit o Call 911 and inform the dispatcher to advise medical personnel that the accident involved lasers. o Contact Health Services first aid services available 519-888-4096 or Ext. 84096. o UW Police assists if the above services are not available 519-888-4911 or Ext. 22222. o Complete incident report. Fire: o Turn off the laser system by pressing the delay off buttons, the delay keys on SDG box and turn off Amplifier from the software on the PC, shut down mantis power unit. o Evacuate area as stated in your Building Emergency Plan. o Active wall mounted fire alarm pull station located at exits. o Call 911 for medical assistance (Ambulance). If using a cell/mobile call UW Police at 519-888-4911. Report any information about fire to UW Police and Fire Department. MME SOP Template v.2013.05.17 Page 5 of 9

OFF DELAYS OFF EVOLUTION OFF MANTIS EXIT EXIT EMERGENCY EXIT FEMTOSECOND LASER LAB MME SOP Template v.2013.05.17 Page 6 of 9

Pre-start Checklist The following items that needs to be inspect before working with lasers: Inspect whether other laser is in operation or not by looking at the warning light. If the light is ON, in order to enter the laser room, ring the bell and wait for someone inside the laser room to open the door. Beware of Laser Interlocks when entering the laser room (To be installed) Remove any reflective material from beam path Enclosure of the experimental area: in order to avoid the risk of dangerous reflections the experimental area should be enclosed with proper shields. Humidity, Temperature values within the range that allows the operation of the laser (see Operation Manual 1) Correct Laser safety glasses. Warning light works properly Curtain closed. Door locked. Safety gloves. Work area should be clean and organized Emergency contact information (UW Police, Health Services, Safety Officer) Start-up Procedure The following items need to be ensured before Laser operation: Stable modelock PD1 and PD2 on the SDG BOX enabled and stable (no blinking) Resolutions for typical problems: Allow warm up time if the problem not fixed switch OFF the laser What indicates all is going well : Smooth seed profile with instant modelock, good modelock seed power Operating Procedure Laser Switch ON Procedure 1. Safety Procedure Remove your foot wear outside laser room and wear laser room internal foot wear Lock the Front door and switch ON the Front door RED Light. Wear the Thorlabs LG9 safety goggles Check the proper enclosure of the experimental area. In order to avoid the risk of dangerous reflections the experimental area should be enclosed with proper shields 2. Dehumidifiers operation Drain out the dehumidifier water Humidity on sensor should be less than 38% to ON the laser Three dehumidifiers available in the lab. User s decides the number of dehumidifier ON during laser operation to keep humidity less than 40%. Better always keep less number of dehumidifiers in operation at any time 3. Thermometer reading Temperature on meter should be less than 25.5 C to ON the laser. For Better operation temperature should be in between 21-22 C If temperature is above 25.5 C, use temperature sensor setting on the front wall to bring it down. Temperature sensor setting on the wall Summer - At the minimum (less than 50 indicator reading) Winter - Adjust the sensor to keep on proper operating temperature 4. Amplifier chiller operation - keep chiller temperature at 23 C Summer - Always ON (Whether laser operated or not). Winter - ON only during laser operation, otherwise OFF. Let the chiller to run 30 mins then ON the laser. (Skip this step if Chiller is already ON) MME SOP Template v.2013.05.17 Page 7 of 9

5. Check and confirm the seed laser chiller (smaller) temperature at 21 C. 6. Turning ON the Mantis Seed laser Check the initial (minimum) power is 0.1 W or less Gradually (very, very slowly- Don t push the black knob in) increase the power to 5.30W Allow 10mins for warm up Trigger the seed laser mode lock button. Press and hold for 2-3 seconds PD1 and PD2 indicators turn to red confirms the mode lock is success PD1 and PD2 indicators are not turn to red leave more warm up time (another 10 minutes) and Trigger the seed laser again. If still indicators are not ON switch OFF the seed laser If PD1 and PD2 indicators are blinking or not stable red shows malfunctioning of system. Switch off the seed laser immediately 7. Turning ON Amplifier laser ON the key switch, click the system in the software and select internal. Check if there is any error in the software monitor. 8. Press the ON button (green) and hold it for 3-5s until you hear 3 buzzer rings. 9. Leave the system to run 15mins. 10. After 15 minutes go to SDG. Press Reset first, then press from right (Delay 2) to left (Delay 1). Note that Sync will always be ON. 11. Mount the power meter and check the output power. 12. When the laser is ON in order to block the laser reaching the experimental area, place the black plate in front of the output beam window with an angle of 7 in order to avoid laser reflections back to the laser. Experimental Setups Two possible experimental setups can be employed for carrying out the experiments with the femtosecond laser. Setup 1 The laser ablation/irradiation is performed from the top with the use of reflective mirrors Extreme attention should be paid when mounting and aligning the laser beam in the center of the mirror Laser goggles should always be worn during the experimental setup and alignment of the mirrors. After the experiment has been setup, enclose the area with the shields (top and lateral) provided in order to avoid reflections of the laser beam MME SOP Template v.2013.05.17 Page 8 of 9

Setup 2 The laser ablation/irradiation is performed in line with the laser Extreme attention should be paid when adjusting the sample within the laser path Laser goggles should always be worn during the experimental setup. After the experiment has been setup, enclose the area with the shields (top and lateral) provided in order to avoid reflections of the laser beam Shutdown Procedure The Laser can be shut down following the following procedure: 1. Check the output power, Press buttons the Delay on SDG from left (Delay 1) to right (syn.). Leave the Sync ON. 2. Press the OFF button (red) and hold for 3s on the monitor. 3. Chiller is not switched OFF during summer. This step should be followed if needed. Wait for 5-10 mins, and then turn down the chiller. 4. Turn off the key switch on Evolution power unit after 20mins. 5. Gradually reduce the Mantis power to around 0.1W or less, and then Turn off the key. 6. Turn off the Red warning light on the front wall. 7. Keep the laser goggles on its place. Clean-up Clean-up procedure: Clean up lab and environment after experiment. Use logs or documentation: Operating conditions should be recorded in log book. Problems, instability, or better operating conditions all should be documented on log book. Where the waste goes: No chemicals, plant operation cleaner. Lockout Document the lockout procedure to use when maintenance or repairs are taking place. Identify and address all sources of hazardous energy. Standard service reports are implemented and filled. Maintenance and Repair The following procedure must be followed during maintenance and repair: Maintain regular log book/schedule for maintenance/repair. Check the laser working envelope regularly, and reposition the limit switch. Contact with suppliers and service companies for maintenance/repair: For Femtosecond Laser: Company: Coherent Person to contact: Robert Letiecq (Coherent) Staff Service Engineer Tech support: 800-367-7890 Robert.Letiecq@coherent.com MME SOP Template v.2013.05.17 Page 9 of 9