For Kidde 10 lb dry chemical fire extinguishers with nylon Zytel (black plastic) valve assemblies & steel cylinders.

Similar documents
Fire Control Fire Extinguisher (FC5)

F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual

OWNER'S SERVICE MANUAL NO INSPECTION, MAINTENANCE AND RECHARGE

Page 1 of 18. Part# /5/2013

50T Electric Shop Press

100T Electric Shop Press

AVANI Grinding Booth

Trainee Handbook. Module 0.1. JSTC Rules and Safety Procedures

Technical Data Sheet No. JS-SM-33 DOCUMENT TITLE. 2.0kg ABE TYPE STORED PRESSURE DRY POWDER PORTABLE FIRE EXTINGUISHER MODEL: R2.

150T Electric Shop Press

Item # Modular Blast CaBinEt instructions

20 TON AIR/MANUAL SHOP PRESS

WARNING USER S MANUAL. Model iq 2000 Series Dust Collector with manual shaker

SHOPSMITH DC-330L DUST COLLECTOR OWNER S MANUAL. For more information: For Question or Support: (937)

Please read this manual before using the machine. Please keep this manual within easy reach for quick reference.

4-GALLON MOBILE PARTS WASHER

FM-200 In-Cabinet Series

MANUAL COVER. To expedite parts ordering or technical questions, please include your Model and Serial Number listed below in all correspondence.

COMPONENT MAINTENANCE MANUAL WITH ILLUSTRATED PARTS LIST

PRO 2000i LOW LEVEL DEPOSITOR

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK

Installation Instruction

MTC-Series Manual Trash Compactors Instruction Manual

IBC600 6-TON IN-LINE CRIMPING TOOL

Item # /2" NPT, 2 STAGE AIR FILTER/DRYER SYSTEM INSTRUCTIONS

OWNER S MANUAL IMPORTANT SAFETY RULES. Deluxe Maintenance Kit IMPORTANT! DO NOT RETURN PRODUCT TO STORE. English

OWNER S MANUAL IMPORTANT SAFETY RULES IMPORTANT! DO NOT RETURN PRODUCT TO STORE. English

BLAST-IT-ALL BUMPER BLASTER

4 TON HYDRAULIC FLOOR PRESS INSTRUCTION MANUEL

PWASH Gallon Parts Washer Assembly & Operating Instructions

SPEAKMAN GRAVITYFLO PORTABLE EYEWASH SE-4000

SPEAKMAN GRAVITYFLO PORTABLE EYEWASH SE-4000

ENGLISH (Original instructions) INSTRUCTION MANUAL. Belt Sander DOUBLE INSULATION. IMPORTANT: Read Before Using.

Technical Data Sheet No. JS-SM-40 DOCUMENT TITLE 2.0 LITRE STORED PRESSURE WET CHEMICAL FIRE EXTINGUISHER

TRAINING BULLETIN TOOLS 1 May 27, 2011 PRESSURIZED WATER EXTINGUISHER

P3HAFEX. System Description

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY

IDT-12-N Hydraulic Crimping Tool

BLAST-IT-ALL PRESSURE BLAST CABINET

Power Tower OWNER'S MANUAL

Models: GW/R-T GW/R-2-T GW/R-3-T

Oscillating Belt/Spindle Sander 230V

Chemical resistant Vacuum Pumps

ACT Cartridge Dust Collector

PURPLE K POWDER EXTINGUISHERS INSTALLATION, OPERATION, MAINTENANCE AND RECHARGE MANUAL

Installation Instructions Part No , Part No Part No

FIRE EQUIPMENT & SAFETY SUPPLIES

918 Clock Gauge Installation, Operation, and Maintenance Instructions

Please read this manual before using the machine. Please keep this manual within easy reach for quick reference.

Bona Portable DCS Manual and safety instructions

PBD1202 CRIMPING TOOL

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

OWNER S MANUAL. Deluxe Maintenance Kit

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

ELECTRIC DRILL INSTRUCTIONS. Item #21285

JASOPELS ROTATING FLESHING MACHINE 1-BEAM

A. Section Includes: Fire extinguishers and cabinets including necessary accessories.

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

SPEAKMAN SPEAKMAN SPECIFICATIONS

568X, 587X, 588X Series

HIGH PERFORMANCE HEAVY DUTY INDUSTRIAL STORED PRESSURE

INSTRUCTION MANUAL WET / DRY VACUUM VC HP V 60 Hz 7A. Gal

MODEL 1308-C & 1308-N

EUTECTIC EC-10DV Series

Models , Equinox, and Sirens Clutch Replacement Service Manual

ASSEMBLY AND OPERATING INSTRUCTIONS 1HP DUST EXTRACTOR. FOX Model F50-841

COMPONENT MAINTENANCE MANUAL

x 24 POLYMER CLAMSHELL CABINET

BRD 36 Part Bun and Roll Divider Rounder Model BRD-36-3, 36 part ¾ - 3 oz Model BRD-36-4, 36 part 1 ½ - 4 oz

MANUAL VERSION SERIAL # X-1 MINI PRO OWNER S MANUAL ASSEMBLY & OPERATOR INSTRUCTIONS 1.0

NR17/NR20 OWNERS MANUAL

Canister Vacuums S6EVO. Operations and Parts Manual. Models: S6EVO

DELUXE ELECTRIC POWER BRUSH

WATER PUMP REQUESTED INFORMATION STANDARD PROCEDURE RAM Pickup 6.7L Eng 2500 STANDARD PROCEDURE - COOLANT AIR EVACUATION

Millo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A

CEMENT MIXER MODEL NO: CCM134L OPERATION & MAINTENANCE INSTRUCTIONS PART NO: GC0514

Operating Instructions

OWNER S MANUAL COMMERCIAL COLD PRESS JUICER

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

VACUUM EXTRACTOR MODEL NO: CWVE1 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: GC0916

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax

DELUXE ELECTRIC POWER BRUSH

Flood Pumper Plus. Water Transfer Machine. Operator and Parts Manual. Model No.: Rev. 00 (11-99)

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

Twin-Agent Fire Fighting/Securing Systems Specifications

Installation Instructions

Penner Stationary Patient Lift Safe Operation & Daily Maintenance Instructions

EZ Melt Fill & Filter EZ18, EZ24 & EZ34. Operator s Manual

D14 & D18 Upright Vacuum

3-1/2 GALLON PARTS WASHER OPERATING INSTRUCTION AND PARTS MANUAL. Model # 4KTV9

HEATING AND AIR CONDITIONING

SUPERDUTY VACUUM. Operating Instructions (EN) & Parts Manual COMMERCIAL CLEANING EQUIPMENT

HEATING AND AIR CONDITIONING

V82VGT ( ) CORDLESS 82V LITHIUM ION GRASS TRIMMER RAPID TRIMMER OPERATOR'S MANUAL. WARNING! Read this manual before operating your product.

AXIS Bodyweight Trainer Owner's Manual

INSTRUCTION MANUAL MODEL: 690E

20-GALLON PARTS WASHER OWNER S MANUAL

VARIABLE SPEED GRINDER OWNER S MANUAL R MANUAL VERSION SERIAL #

SuperKlean Washdown Products

Transcription:

For Kidde 10 lb dry chemical fire extinguishers with nylon Zytel (black plastic) valve assemblies & steel cylinders. IMPORTANT: MAKE SURE YOU FULLY FAMILIARIZE YOURSELF WITH THE PROCEDURES DESCRIBED IN THIS BOOKLET BEFORE CARRYING OUT THESE INSTRUCTIONS.. These instructions contain two parts: The following safety equipment (not supplied) is required to be worn when carrying out these instructions. Safety helmet Ear protection Full face mask Particle respirator mask PART ONE is a guide to identifying and removing Kidde s 10 lb dry chemical Zytel (black plastic) valve, steel cylinder fire extinguishers safely from their wall/cabinet/floor mount. Wear safety helmet Wear ear protection plugs or ear muffs Wear ANSI approved full face mask Wear NIOSH particle respirator, Class N95 Part number: 21005128B PART TWO is a guide to depressurizing the extinguisher in an appropriate manner. The extinguisher must be removed from service and disposed of in accordance with these instructions. Avoid positioning any part of your body over the extinguisher and valve during these procedures. Failure to follow these instructions properly could result in serious bodily injury or death. Kidde Residential and Commercial 1394 South Third Street Mebane, NC 27302 Tel. 919-563-2711 COPYRIGHT 2004 YOU WILL NEED When carrying out these instructions you will require the Kidde Containment Bag (part # 21005099, supplied), a dry chemical discharge bag (not supplied) and a condemned sticker. HAVE QUESTIONS? Additional information in the form of FAQs is available at www.kiddeus.com/ excel.shtml or from Kidde customer service at 1-877- 777-8170

CONTENTS Page 1 Contents Page 2 Page 3 Page 4 Indentifying the correct Kidde fire extinguisher to remove from service Part One - Placing extinguisher in Containment Bag Step 1 - Aligning the containment bag correctly Steps 2 & 3 - Placing unit in containment bag Page 6 Page 7 Step 4 - Preparing for depressurization Part Two - Depressurizing extinguisher. Steps 1 through 6 Instructions for discharging unit into a discharge bag. Page 9 Page 10 Page 11 Steps 1 through 6 Instructions for discharging unit into a dry chemical recovery system. Step 7 Safe removal of unit from containment bag Step 8 Disposal of dry chemical & disarming of extinguisher Step 9 Returning valve assembly to Kidde Notes Page 1

INDENTIFYING THE CORRECT FIRE EXTINGUISHER These safety instructions cover the Kidde 10 lb dry chemical steel cylinder, Zytel (black plastic) valve fire extinguishers pictured at right. AFFECTED MODELS STEEL CYLINDER WITH WELDED NECK RING & NYLON VALVE REMOVE FROM SERVICE fig.1 AFFECTED MODEL STEEL CYLINDER WITH WELDED NECK RING & NYLON VALVE REMOVE FROM SERVICE Approx. 19-21 Height These instructions only apply to those models that were manufactured with Zytel (black plastic) valve assemblies and steel cylinders (see fig 1 above). fig.2 NON-AFFECTED MODEL ALUMINUM CYLIN- DER HAS TAPERED NECK AND NO WELDED NECK RING LEAVE IN SERVICE Those models that were manufactured with Zytel (black plastic) valves and aluminum cylinders (see fig 2) are not affected and can remain in service. ONLY 10 LB DRY CHEMICAL MODELS ABOVE THAT WERE MANUFACTURED BETWEEN 1991-2000. Page 2

PART ONE - PLACING EXTINGUISHER IN CONTAINMENT BAG IMPORTANT When carrying out the following procedures you MUST wear the protective equipment listed right. Wear safety helmet Wear ear protection plugs or ear muffs Wear ANSI approved full face mask Wear NIOSH particle respirator, Class N95 STEP 1 Hold containment bag upright as shown with the word top as indicated. Top straps must be in a crossing pattern across the top of the containment bag as shown. Ensure bag is correctly oriented Follow the directions for safe insertion into the bag for: Wall mounted extinguishers (pg. 4) Cabinet mounted extinguishers (pg. 5) Floor standing extinguishers (pg. 5) Refer to the section that deals with your situation. Page 3

STEP 2- PLACING UNIT IN CONTAINMENT BAG Avoid positioning any part of your body over the extinguisher and valve during these procedures. Failure to follow these instructions properly could result in serious bodily injury or death. WALL MOUNTED EXTINGUISHERS If unit is on a wall hanger, carefully cover the extinguisher with containment bag by placing over the valve assembly (first) and bottom of the cylinder (second) with the bag opening facing away from you as shown. Place one hand under extinguisher and support the side with the other hand as shown. Make sure you slide the bottom portion of the containment bag entirely under the base of the cylinder. Page 4

CABINET MOUNTED EXTINGUISHERS While unit is in the cabinet, carefully rotate the extinguisher so that the pressure gauge points left and the hose assembly points away from you. Cover the extinguisher with containment bag by placing it over the valve assembly (first) and sliding the bag under the bottom of the cylinder (second) with the bag opening facing away from you. 1. Cover valve assembly 2. Slide bag under the bottom Take bag and extinguisher out of cabinet, making sure top and bottom of cylinder remain covered by the bag. FLOOR MOUNTED EXTINGUISHERS If unit is floor mounted, carefully cover the extinguisher with containment bag by placing it over the valve assembly (first) and sliding the bag under the bottom of the cylinder (second) with the bag opening facing away from you. 1. Cover valve assembly 2. Slide bag under the bottom STEP 3 - Gently lower the extinguisher to the floor and rest the extinguisher on its side with the valve pointing away from you or any bystanders. Page 5 3. Gently rest unit on the floor, making sure valve points in a safe direction away from you and any bystanders.

Extinguisher MUST remain in the containment bag. STEP 4 - PREPARING FOR DEPRESSURIZATION Note: Extinguisher MUST remain in the containment bag. In preparation for Part Two, rotate the extinguisher so the pressure gauge is pointing towards the bag opening. Gently fasten the two straps into their metal clamps. After both straps are fastened, secure each strap with a gentle, but firm pull. Extinguisher is now in a safe condition and can be transported to a safe area for depressurization and disposal. Replace with the new Kidde Safety PRO 10 replacement extinguisher. Page 6

PART TWO - DEPRESSURIZING THE UNIT Part Two is a guide to depressurizing Kidde s 10 lb dry chemical, Zytel (black plastic) valve, steel cylinder fire extinguisher after recovery from field service, described in Part One. IMPORTANT When carrying out the following procedures you MUST wear the protective equipment listed right. Wear safety helmet Wear ear protection plugs or ear muffs Wear ANSI approved full face mask Wear NIOSH particle respirator, Class N95 Avoid positioning any part of your body over the extinguisher and valve during these procedures. Failure to follow these instructions properly could result in serious bodily injury or death. DISCHARGING UNIT INTO A DISCHARGE BAG STEP 1 - TRANSPORT UNIT Transport extinguisher to a safe area for depressurizing. Carefully disconnect upper plastic strap connector, but leave unit in containment bag. Remove pull pin Page 7

STEP 2 - DISENGAGE HOSE FROM CYLINDER STRAP Ensure hose assembly is disengaged from hose strap and the nozzle is located outside of the bag. STEP 3 - REMOVE PULL PIN STEP 4 - RAISE CARRYING HANDLE This will ensure extinguisher will depressurize. IMPORTANT: If the handle is not aligned as shown, it will NOT operate. STEP 5 - REFASTEN STRAPS Gently connect the upper strap into its plastic connector. After strap is fastened, secure with a gentle, but firm pull. STEP 6 - PREPARE FOR DEPRESSURIZATION Properly directing nozzle, invert the extinguisher to depressurize. Insert nozzle into dry chemical discharge bag (not supplied). Gently allow the weight of the extinguisher to operate the lever. Locate hose outside of bag Align valve handle parallel to lever Fasten straps keeping hose out Invert and discharge unit into discharge bag Page 8

DISCHARGING UNIT INTO A DRY CHEMICAL RECOVERY SYSTEM STEP 1 - TRANSPORT UNIT Transport extinguisher to a safe area for depressurizing. Carefully disconnect upper plastic strap connector, but leave unit in containment bag. STEP 2 - DISENGAGE HOSE FROM CYLINDER STRAP Ensure hose assembly is disengaged from hose strap and the nozzle is located outside of the bag. STEP 3 - REMOVE PULL PIN STEP 4 - RAISE CARRYING HANDLE This will ensure extinguisher will depressurize. IMPORTANT: If the handle is not aligned as shown, it will NOT operate. STEP 5 - REFASTEN STRAPS Gently connect the upper strap into its plastic connector. After strap is fastened, secure with a gentle, but firm pull. Align valve handle parallel to lever STEP 6 - PREPARE FOR DEPRESSURIZATION Connect nozzle to dry chemical recovery system and depressurize the extinguisher. Page 9 Ensure extinguisher remains in containment bag during dry chemical recovery

STEP 7 - SAFE REMOVAL OF UNIT FROM CONTAINMENT BAG Once all the pressure gas is released, it is safe to remove the extinguisher from the containment bag. STEP 8 - DISPOSING OF DRY CHEMICAL & DISARMING EXTINGUISHER Ensure proper disposal of the dry chemical. Place condemned sticker over front operating label and shatter pressure gauge to render inoperable. STEP 9 - RETURNING VALVE ASSEMBLY TO KIDDE Remove valve assembly from extinguisher, note extinguisher serial number, and return valve and serial number to Kidde at the address below. For ease of shipment, hose and siphon tube can be removed. Apply condemned sticker Kidde Residential and Commercial Excel Line Return 1394 South Third Street Mebane, NC 27302 Include a packing slip with each shipment indicating the number of valve assemblies returned. Disable gauge Should you require further information regarding these instructions, a list of frequently asked questions has been prepared and can be viewed by visiting our web site, or you can call our customer service department to discuss. www.kiddeus.com/ Customer service:1-877-777-8170 Page 10

NOTES SAFETY INSTRUCTIONS