Model LA-2SP. Air Purification Unit. User Guide. Bring Freshness Indoors

Similar documents
Air Purification Unit MODEL 300/RHO2 USER GUIDE. Because You Care, Clean the Air

Commercial Air Purifier. Model HMA-3500-TC. Air Purification Unit. User Guide. Knock out odors at their source

WARNING CAUTION ATTENTION. Q: What is an ozone alert? Q: How does it compare to air filters? Q: Is ozone safe?

Bring Mountain Freshness Indoors

For Air as Pure as the Ice Age

7000/AP. Ozone Generator Air Purifier / Sterilizer. User Guide

AIR PURIFIER OZONE GENERATOR

For Air as Pure as the Ice Age

CA3500, BA3500, CH3500 New Comfort

AIR PURIFIER CLASSIC INSTRUCTION MANUAL. CAUTION: Read manual carefully for correct procedures and proper operation.

WHYNTER Eco Pure Air Purifier

Eagle 2500 TM OWNER S MANUAL. Electronic Air Purification 110 and 220 volt Systems. EcoQuest International. Application.

OWNERS MANUAL. Installation. Operation. Specifications. Features. Maintenance. Warranty REV 02_04 FA SP-ENG OM - 02_04

Ozone Generator Air Purifier HE-500/O3

OWNERS MANUAL. Installation. Operation. Specifications. Features. Maintenance. Warranty REV 0905 FAOM15_0905

IMPORTANT INSTRUCTIONS OPERATING MANUAL

Instruction Manual FEEL THE ENERGY. FEEL THE FRESHNESS.

USE & CARE INSTRUCTIONS

MULTI-TECH II INSTRUCTION MANUAL. Model XJ-3000D

7. CARE AND MAINTENANCE

AirInstinct Air Purifier

USER MANUAL EAP120HC. Unit 2, The Nursery Berristow Lane South Normanton Derbyshire, DE55 2FX

Welcome to a Healthy Home

with plasma ioniser and Remote Control USER MANUAL

Ionic Breeze QUADRA Silent Air Purifier. SI637 SI697 Instructions

CAP600AWS Compact Air Purifier with Plasma Ionizer USER MANUAL

Clean Air Optima UV Plasma Ionizer Air Purifier CA-401

Owner s Manual. Table of Contents

INSTRUCTION MANUAL. Remember to register your air purifier at: Multi-Tech 8500 Air Purifier

Coway Air Purifier AP-1008DH

USER S MANUAL AQV09V A Series AQV12V A Series AQV18V A Series AQV24V A Series

Clean Air Optima Plasma Ionizer Air Purifier CA-267

Powr-Zone Ozone Generator

OVHM80 Max Air Purifier

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

instructions for use Air Purifier with ionizer _00/

BEFORE OPERATING, READ ALL INSTRUCTIONS IN THIS MANUAL CAREFULLY.

Comefresh CF-8608 Air Purifier

Register your product and get support at. AC4006. User manual

register your product at a2zozone.com/pages/warranty Air-7000 & Air-3500 Operating Manual

DESCRIPTION OF THE APPLIANCE SAFETEY OPERATION CAUTION MAJOR COMPONENTS. Features

THANK YOU FOR PURCHASING THE LV-H133 TOWER HEPA AIR PURIFIER BY LEVOIT! GET STYLE #LevoitLove #LevoitLifestyle

IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS AIR PURIFIER

Register your product and get support at AC4002 AC4004. User manual

Introduction (Thanks / Warnings / Records) Features / Benefits Controls / Diagrams Initial Setup (Placement / Settings) Operations Maintenance

Professional HEPA Air Cleaner

Model: AW600. Triple Action Humidifier. Winix Inc. 120 Prairie Lake Road U nit E East Dundee, IL USA

GASBLASTER LSX4 OPERATION MANUAL

LOCK H M L REPLACE SLEEPING ANTI-POLLEN IONIZER UV-LAMP. User Manual

INTERNATIONAL OZONE TECHNOLOGIES GROUP, INC.

Bosch Split-Type Ductless Air Conditioner / Heat Pump

Owners Manual Model: XXL

Healthy Climate Indoor Air Quality Solutions. Solutions that fit your unique needs

AIR PURIFIER WITH GERMICIDAL UV LIGHT

Register your product and get support at. AC4076. User manual

User Manual Manual del usuario Guide d utilisation. Blueair 400 Series

Portable Room Air Conditioner and Heat Pump

Clean Air Optima HEPA UV ionizer air purifier CA-508

NEXXOS INVERTER USER MANUAL

Owner s Manual Super-Slim Four-Way Cassette

BioZone AirCare. The AirCare series contains the following units:

AY-AP09DJ SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL AE-A09DJ AY-AP09DJ OUTDOOR UNIT INDOOR UNIT

Model & Replacement Pre-Filter Information Model Pre-Filter F Hunter Fan Company

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

AIR CLEANER A GUIDE TO OPERATING AND MAINTAINING YOUR ELECTRONIC. NOTE TO INSTALLER: This manual should be left with the equipment owner.

STATIC ELIMINATOR I443A INSTRUCTION MANUAL

Air always contains a certain amount of water in the form of vapour. This determines the

Healthy Climate Indoor Air Quality Solutions. Solutions that fit your unique needs

DIGITAL Warm & Cool Mist Humidifier

TOTALCLEAN AIRPURIFIER. instruction manual. YEARGuarantee AP-25A-GB

CLEAN MIST DUAL TANK SMART HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0036A

AH-PNX11 AU-PNX11 AH-PNX14 AU-PNX14 EN-1 SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL ENGLISH

Blueair 500/600 Series. User Manual

User manual. Always there to help you. Question? Contact Philips AC3252 AC3254 AC3256

TPP440. owner s guide. air purifier with uv light. air purifier with uv light TP

IMPORTANT INSTRUCTIONS OPERATING MANUAL

Air Cleaning System USE & CARE INSTRUCTIONS. Model No. AC4300BPT 3-Year Limited Warranty

Air Purification System. Instruction Book CLI-AP20

Triple Action Humidifier Model: AW600

KSD-35 DR11 KUE-35 DVN11

Owner s Manual. Fairwind Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

Coway Air Purifier AP-1008BH/CH

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

Up to 60 Pint Commercial Grade DEHUMIDIFIER

Table of Contents SAFETY FIRST. Owner s Manual. Safety Precautions Unit Specifications and Features Manual Operation (Without Remote)...

INFRARED ZONE HEATING SYSTEM

SHARPER IMAGE. Professional Electrostatic Air Purifier with Permanent Stainless Steel Filter Model: and USE AND CARE GUIDE

TOWER AIR PURIFIER FOR THE FOLLOWING MODEL : EE-5067

PA / PA-PRO PORTABLE AIR PURIFIER Instruction Manual

New-AireAirPurifiers

GDDEM10 DEHUMIDIFIER

INDOOR UNIT/OUTDOOR UNIT

GENANO AIR PURIFICATION TECHNOLOGY

Blueair Pro User Manual

Owner s Manual SPLIT-TYPE ROOM AIR CONDITIONER

Surgically Clean Air Inc.

Instruction Leaflet. pure indoor living MODEL: BAP1502WO-CN. filter series AIR PURIFIER WITH ODOR ELIMINATOR FILTERS

HEPAtech. Air Purifier. English. Owner s Manual. Model Hunter Fan Co.

AdvancedPureAir.com

Electrostatic Air Purifier

Transcription:

Model LA-2SP Air Purification Unit User Guide Bring Freshness Indoors 1

Contents Quick Start... 3 Features of the Model LA-2SP... 4 Operation/Installation... 6 Determine Your Square Footage... 7 Using a Timer... 8 Where to Use... 8 Service... 8 Warranty... 8 Cleaning & Maintenance... 9 Troubleshooting... 9 Understanding the 03 Sanitizer... 10 WARNING This air unit is not a medical device. Do not stop or alter any medical therapy programs or medications without the advice of your physician. Excessive ozone concentrations may cause mucous membrane or respiratory irritation. CAUTION RISK OF ELECTRICAL SHOCK DO NOT OPEN ATTENTION Caution: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE BACK COVER. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVCE PERSONNEL. 2

Read ALL instructions and information contained in this product guide before using this product. QUICK START 1) Normal Operation: Turn the Ionization dial on and select fan speed. The unit should be located at least two to three feet off the floor and at least three feet away from sitting and sleeping areas. 2) Sanitizer Mode: The O 3 Sanitizer is most effective in unoccupied spaces to eliminate odors and significantly reduce mold and mildew. Close all doors and windows in the space to be treated. Turn Sanitizer dial on and select square feet setting. Vacate the space for 1 to 4 hours depending upon the severity of the odors. Return to space, turn Sanitizer dial off, open doors and outside windows until sanitizing smell is gone. Warning: Excess ozone (O 3 ) concentrations can cause mucous membrane and respiratory irritation. If you detect the sanitizing smell when you walk into the room turn the Sanitizer dial off or down to a lower level. 3

Front View Dual Ion Emitters Fan Grill 03 Sanitizer Control Setting On/Off Ionization Fan Speed Part Function Ionizer ON/OFF & Fan Speed On/Off activates the unit and turns on the Ionic Purifier it also controls the fan speed. 03 Sanitizer Square Feet Activates the ozonator and adjusts by square footage of treatment area. The unit should be adjusted according to size of treatment area and sensitivities. Fan Grill Removable fan grill. May be wash with warm soapy water. Dry completely before replacing. (Unplug unit before removing) Control for the negative ion generator is separate from the activated oxygen control. Negative ions can be created around the clock to keep down dust and particulate. Ozone or activated oxygen is normally kept at modest levels in occupied spaces. To remove heavy odors, the units may be adjusted to a higher level for a period of time. Some use a timer to completely deodorize the home or office while away. Unused O3 reverts back to O2 in about an hour. 4

Convenient Handle Back View Plate Receiver Slot Ceramic Plate Air Vents Grounded Power Cord Fuse Holder Part Plate receiver slot Ceramic Plate Fuse Holder Power Cord Handle Function Allows for easy insertion and removal of ceramic plates for cleaning. Removable ceramic plate. Wash with warm soapy water. Rinse and dry completely before replacing Houses removable fuse. (Spare fuse included, 1 amp, 1.25 inch) 110 Volt grounded cord (unless otherwise specified). DO NOT bypass ground. Allows for easy moving from one room to another This unit must be provided with an electrical ground at all times! 5

Operation / Installation Start with the LightningAir on its lowest Square Feet setting and turn the Ozonator dial up as necessary. The ideal amount of activated oxygen will leave your room smelling clean and fresh. If the unit is set too high, you will smell the ozone. If it set too low, you will smell household odors. The Ionizer is designed to run independently from the activated oxygen production. The ionizer can be used around the clock to keep down dust and particulate. Ozone, however, should be kept at modest levels in occupied spaces. Ozone s primary application is to control odors. The level of ozone may be adjusted according to the severity of the odors in the home or office. Many users put the purifier on a timer so it can run at high levels while being away. The timer is set to cut off about one hour before the occupants are scheduled to return. The O 3 that is not used normally reverts back to O 2 in about an hour. When they arrive the air is fresh and clean. Individual sensitivity to activated oxygen and preference may vary and should be adjusted accordingly. The effect of activated oxygen on indoor air may vary according to atmospheric and/or environmental conditions such as altitude, humidity, air movement, severity of existing odors, house design, and square footage. If you desire to treat the entire home with the same level of ozone, set the fan switch on your home s heating & cooling system to the ON position rather than AUTO. Open all interior doors and adjust the activated oxygen level to the appropriate square footage. Then place the unit so the air from the purifier flows directly into a air return vent. Altitude: Generally, in higher altitudes the requirement for activated oxygen decreases. Therefore, higher altitudes should require lower settings. Humidity: Generally, in higher humidity the requirement for activated oxygen increases. Therefore increased humidity may require higher settings. For optimal treatment of air in your designated area, your new air purification unit should be placed in a central location (higher is better). Your unit can be set on a tall piece of furniture. Allow three inches between the back of your unit and the wall to allow proper airflow. Fan speed is normally set in the medium range. The reason for elevated placement of the unit is that activated oxygen is heavier than air. Elevated placement allows for better circulation. It is suggested that the purifier be placed in the room that is close to the primary source of odor. 6

Here s how to determine the Square Feet Setting for your home or office: Measure total area of each room to be treated. Add area of room(s) together for total area to be treated. Note: If doors are open to another room, add that area also. Measure total enclosed area. The customer may use more than one LightningAir unit in order to better control levels of activated oxygen in different areas of your home or office. The concentration of ozone will be higher in the immediate area of the unit. Example: To determine the total square feet of area to be treated. Determine Your Square Footage 15 375 Square Feet 300 Square Feet 600 Square Feet 15 500 Square Feet 25 20 400 Square Feet 20 800 Square Feet 40 20 375+500=875 square feet 300+400+600+800=2,100 square feet Warning: Excessive ozone concentrations may cause mucous membrane or respiratory irritation and can be harmful. If you smell ozone when you enter a room, turn the Square Feet dial down to a lower setting. 7

Using a Timer Some users who are sensitive to ozone set their units up on a timer so that the purifier does its work only when they are away from home. This allows for a higher setting and higher concentrations which can be more effective for purging purposes. The ozone will normally dissipate in less than an hour after the purifier is turned off. Simple timers plug into an outlet and are available at hardware and variety stores. Where to Use Homes & living areas All types of offices & stores Water & fire damaged areas New paint, wallpaper & paneling Odor clean-up Sick buildings Hospitals & nursing homes Veterinary offices Smoking areas Hotel rooms High pollen environments New carpet & furniture Kitchens Attics & basements Laundry rooms Doctors offices Day care centers Stables & aviaries Locker rooms Restaurants & bars Service Should you determine that your air unit requires service, please call 877-312-8200 as listed on he back panel of the unit. Non U.S. customers send fax to 850-893-2594 for instructions. Warranty Your air unit comes with a 3 year limited warranty from the date of original purchase. Refer to enclosed warranty card for complete details. Please complete and return the warranty registration card within ten days of date of purchase in order to activate your warranty. 8

Cleaning & Maintenance When the purifier no longer produces enough ozone to be effective, the ozone plate should be cleaned. A good rule of thumb is every three months. Some environments cause ozone output to be reduced in a shorter time but other environments may take longer. To clean a plate, first turn the unit Off and unplug from outlet. Then remove the 4 x4 plate or plates from back of unit. Pull plates firmly in the center to remove from the slot. With plate firmly supported in the hand, wash plate with warm soapy water or a grease cutting detergent. Scrub with stiff brush if necessary. Be careful not to drop the plate or scrub off the silicon. Clean both the metal screen and the ceramic tile. Rinse plate in hot water and dry completely before installing. If available, you may use a hair dryer to dry the plate. Reinstall plate, making sure it is secured and flush with the back of the unit. Plug unit into a grounded 110 electrical outlet, turn unit on and start enjoying clean fresh air. To clean needlepoint ionizer, first turn Off and unplug from outlet. Remove the fan grill cover. The needlepoint ionizer will be easy to find in front of the fan by looking for two pieces of wire. Take a q-tip or cotton swab dipped in alcohol and clean any dirt that may have accumulated on the needlepoints. This process may be done when plates are being cleaned. While you have the front grill cover off the unit you may also clean the fan and the grill itself. To clean the fan simply wipe the blades with a damp cloth or vacuum. The grill cover may also be cleaned with warm soapy water. Be careful that the fan grill cover is completely dry before reinstalling. Troubleshooting If you suspect a problem with your unit check the following: Make sure plate is clean (see above). Unit is plugged in properly and turned on. Check the fuse to make sure it is installed properly and not burned out. To replace fuse, push in and turn fuse holder to the left, remove old fuse, replace with spare. Use 1 amp fuse, 1.25 inches long. Wall outlet is active. Check plate alignment, making sure the ceramic plate is almost flush with back of unit. It important that the LightningAir be properly grounded to avoid potential shock. If the fan is not operating or no buzzing sound is detected on the high setting of the Ozonator dial, call the Service / Warranty Service listed on the back of unit. Caution: No attempt should be made to remove the back panel of the unit, as there are no user serviceable parts. Opening the unit will void all warranties. 9

Understanding the 0 3 Sanitizer Ozone is basically supercharged oxygen. Regular oxygen is O 2 and ozone is simply O 3. Nature regularly transforms oxygen into ozone through forces such as lightning and ultra-violet light striking the earth. O 3 then acts as a natural sanitizer. After a short period of time the ozone reverts back to regular oxygen at ground level. How We Learn About It We learn about ozone in two different ways. The first is the protective ozone layer in the upper atmosphere that helps to reduce the amount of ultra-violet light that strikes the earth. This layer of O 3 is gradually being depleted as a result of specific pollutants such as aerosols and the older refrigerant gases. Steps have been taken to reduce these pollutants, but there is an ongoing concern about protecting the ozone layer. The second way we learn about O 3 is the ground level ozone in polluted cities. Automobiles and industry put out excessive levels of hydrocarbons into the air through exhaust emissions. When ultra-violet (UV) light from the sun strikes hydrocarbons, ozone is created. For millions of years, nature has created ozone by sunlight striking hydrocarbons, emitted from decaying matter, as one way it keeps the earth clean. This is nature s response to pollution in the air. When the exhaust emissions are high, the O 3 levels become high as a response to the hydrocarbons. The level of ozone in some cities may exceed 200 parts per billion (ppb) on days when pollution is high. On the other hand, without O 3 and UV light the earth would be an odorous place with mold, mildew and viruses running rampant. The forces of nature are designed to keep the outdoors clean and healthy. Unfortunately, there is normally very little ozone in our indoor spaces where we spend nearly all of our time. This is because the buildings where we live and work are designed to shut nature out. How It Is Used Ozone is created by man for purification purposes. It is injected in nearly all bottled waters and is widely used in Europe for treating municipal water supplies. O 3 is also used for indoor air treatment but it must be employed in a manner that is both safe and effective. The typical way O 3 is used commercially for air treatment is by blasting a high level of ozone into an unoccupied space. For example, if a hotel wants to change a smoking room to a non-smoking room, they use an ozonator such as the LightninAir Industrial Cleaner to pull odors out of the carpet, drapes, bedding, etc. Smoke damage restoration services also use O 3 to remove odors. The FDA has approved O 3 for treatment of air and water in food processing plants. Water damage restoration companies treat air with O 3 at high levels in unoccupied spaces to get rid of smells as well as mold and mildew. Some restaurants, bars and casinos are now beginning to use ozone at relatively low levels to keep the air smelling fresh and clean at all times. 10

High Level Use The O 3 Sanitizer may be used to treat unoccupied spaces, including the entire home or small office. This is the most effective way to attack microorganisms and reduce strong odors because it allows the O 3 to go after pollutants at the source. Ozone has been proven to reduce levels of mold, mildew and other microorganisms. It will also help accelerate the dissipation of chemicals from new carpet, furniture and paint. Simply close off the problem area or shut the windows and doors in the entire home. Next, set the O 3 dial to correspond to the size of the area to be treated. Then leave the space for 1 to 4 hours depending on the severity of odors. Upon return, open the doors and windows to let in fresh air until the O 3 smell is gone. Perform this procedure as often as necessary until the odors are removed. Timer Many users prefer a plug-in timer like is used on lamps so that it comes on everyday for a few hours while they are at work and then shuts off a couple of hours before they return home. When they walk in the air smells fresh and clean and the O 3 has reverted back to normal O 2. Occupied Spaces Some users keep the O 3 Sanitizer at a relatively low setting while in the home or office. This can hold down microorganism growth while keeping the air smelling fresh and clean. However, caution is advised because O 3 levels may exceed those recommended by government agencies. Each home is different so it requires a trial and error process to locate the right setting on the dial. If you choose to use the O 3 Sanitizer in occupied spaces, set the ozonator dial at a modest level initially and let it run for a couple of hours. If you smell ozone when you walk into the room, turn the dial down or off. On the other hand, if you smell household odors, turn the dial slightly up. Repeat the process until you walk into the room and do not smell household odors or ozone just clean fresh air. Caution is the key to use of the O 3 Sanitizer in occupied spaces. Caution Excessive ozone concentrations can cause mucus membrane or respiratory irritation. Individuals with serious respiratory problems such as emphysema should consult their physician before use. Those with a poor sense of smell should also exercise caution. If O 3 is detected when entering a room turn the O 3 Sanitizer dial down or off. If a dry throat, cough or watery eyes is experienced ventilate the area and discontinue use. The level of O 3 generated at a particular setting on the dial will vary with humidity, altitude, household contents, level of pollutants in the space and other factors. The average person is able to smell ozone as the room level approaches 20 ppb indoors. The FDA sets an upper level of 50 ppb in continuously occupied spaces for sensitive persons such as the very young, the elderly and the sick. The EPA has set a target level of 80 ppb for outside air in cities but that is regularly exceeded. A rule of thumb is to turn the Sanitizer dial off or down if the O 3 smell is detected. 11

SpringCo Manufacturing 2940 Kerry Forest Parkway Tallahassee, Florida 32309 12