icomfort Residential Communicating Control System icomfort Touch Communicating Thermostat

Similar documents
CONTROLS WI-FI THERMOSTAT. icomfort Wi-Fi Flex Thermostat PRODUCT SPECIFICATIONS

TOUCHSCREEN. COMFORTSENSE Day Programmable Thermostat. 4 Heat / 2 Cool Universal Multi Stage MODEL NUMBER IDENTIFICATION L U FEATURES

INSTALLER'S SYSTEM SETUP GUIDE NOTICE

icomfort Residential Communicating Control System Equipment Interface Module (EIM)

Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems

DAVE LENNOX SIGNATURE COLLECTION PureAir S Air Purification System

User Guide. Color Touchscreen Programmable Residential Thermostat. ComfortSense Model: 13H /2015 Supersedes 7/2015

ComfortSense 7500 Thermostat. User Guide

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

ComfortSense 7500 Commercial Thermostat. User Guide

Safety & Installation Instructions

DAVE LENNOX SIGNATURE COLLECTION Humiditrol Whole-Home Dehumidification System

Installation Instructions

The XP21 raises the bar for efficiency and comfort.

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

COMFORT CONTROL - 4 HEAT (GAS, OIL*, OR ELECTRIC)/3 COOL/HEAT PUMP COMMUNICATING PROGRAMMABLE 3 WIRE HOOKUP

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE

Home Comfort Systems. The quietest furnace you can buy* and one of the most efficient! Featuring new Precise Comfort and AirFlex Technologies

PROGRAMMING AND APPLICATION GUIDE IMPORTANT IMPORTANT. ComfortSense 7000 Series. CONTROLS /09 Supersedes 04/09. Shipping and Packing List

CONTROLS /08 Supersedes 05/08

ATC32U03 igate Communicating, Programmable Thermostat

WARNING IMPORTANT. iharmony Zoning System CONTROLS KITS AND ACCESSORIES. Installation Instructions for the iharmony Zoning System (10C16)

complete comfort Heat Pumps

PROGRAMMING AND APPLICATION GUIDE IMPORTANT. ComfortSense 7000 Series. CONTROLS /08 Supersedes 05/08. Shipping and Packing List

ComfortSense Model L7742U Thermostat. Display Fields & Touch Screen Points. Features. Description

ATC32U01 igate Communicating, Programmable Thermostat

Advanced Installation and Configuration Instructions

USER S INFORMATION MANUAL

DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

HOMEOWNER'S MANUAL WARNING NOTICE. icomfort Wi Fi Thermostat. CONTROLS /2013 Supersedes General

Xc21 air conditioner up to seer Xc21

complete comfort Heat Pumps

XC21. XC21 Air Conditioner Up to 20.5 SEER. Home Comfort Systems. The most quiet and efficient central air conditioner you can buy*

Homeowner s Guide / 1

User s Manual

81M26 81M27 81M28. User's Manual. Menu Driven Display DELUXE PROGRAMMABLE THERMOSTATS

DUAL ZONE CONTROL PANEL Zone Control For Residential Heating/Cooling Systems

XP21 The most quiet and efficient heat pump you can buy*

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

WARNING This product contains a chemical known to the State of California to cause cancer, birth defects, or other reproductive harm.

Installation Instructions

perfectly efficient SLP98V The most efficient and quietest furnace you can buy.*

PS4000 and PS5000 Touchscreen Programmable Thermostat Installation and Owners Manual Robertshaw 01/

Commercial Touchscreen Thermostat

WARNING This product contains a chemical known to the State of California to cause cancer, birth defects, or other reproductive harm.

Instruction Guide: Thermostat Operation

Evolution Control. Zone Control Homeowner s Guide

HEAT HEAT HEAT COOL COOL

complete comfort Heat Pumps

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

CB X 32 mv

HEAT HEAT HEAT COOL COOL PUMP OWNER S MANUAL 7-DAY TOTALINE

OWNER S MANUAL Venstar Inc. 08/07

Installer Guide. WARNING Important Safety Information. 1 Specifications

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

The XP17 provides comfort without comparison.

Home Comfort Systems. g60v. The quietest furnace in its class*

Must be installed by a trained, experienced technician

OWNER S MANUAL Venstar Inc. 08/07

HEAT COOL. Meets Commercial California Title 24

Installation and Setup Guide

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

Installation Instructions

DAVE LENNOX SIGNATURE COLLECTION Variable Capacity - Precise Comfort Technology

up to 98.7% efficiency can save over $800 a year** The SLP98V is a choice you can feel good about.

incomparably cool XC21 The most quiet and efficient central air conditioner you can buy*

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

The XC17 is an efficiency expert.

7-Day. Digital Thermostat. residential. & 2-cool

OWNER S MANUAL Venstar Inc. 08/07

complete comfort Heat Pumps

User s Manual. THE iq Drive SYSTEM USER S INFORMATION IMPORTANT. Variable Speed Ultra-High SEER Split System IMPORTANT NOTE

IMPORTANT Read and save these instructions. OWNER S GUIDE. ComfortSense 5000 Series Models L5711U and L5732U Programmable Touch Screen Thermostats

SAS6000UTK-7 UNIVERSAL THERMOSTAT

EWT-3102/EWT-3103 Touchscreen Programmable Thermostat

Infinity Control. Homeowner s Guide. The New Feeling of Comfort

YEAR-ROUND COMFORT EVOLUTION CONTROL ZONE CONTROL HOMEOWNER S GUIDE. The Ultimate Home Comfort System.

Safety & Installation Instructions

T-32-TS Touchscreen Thermostat. Installation Manual

The XC21 delivers the ultimate in comfort.

complete comfort Heat Pumps

A heat pump that redefines comfort and efficiency.

Siemens RDY2000BN. Start Up Guide

VisionPRO 8000 with Wi-Fi

VisionPRO IAQ Total Home Comfort System

User s Manual ELITE PROGRAMMABLE THERMOSTAT WITH MENU DRIVEN DISPLAY

CT1001/CT1002 Touchscreen Programmable Thermostat

EL-TSTAT-8820 Safety & Installation Instructions

Installer Guide. WARNING Important Safety Information. 1 Specifications

Auto-Changeover: Cool Setpoint: Deadband: Dehumidify: Differential: Heat Setpoint: Humidify: Icon: Mode: Non-Programmable Thermostat:

XC17. DAVE LENNOX SIGNATURE COLLECTION R-410A - SilentComfort Technology. SEER up to to 5 Tons Cooling Capacity - 21,800 to 59,000 Btuh

Safety & Installation Instructions

efficient solutions Air Handlers

VisionPRO IAQ Total Home Comfort System

1F Day 5/1/1 Day Non-Programmable. W/ Economizer Max. Stage Heat/Cool 1/1 1/2 2/2 2/3 3/1 3/2 4/2 4/3

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

Operating Manual. Series Touchscreen Programmable Demand Control Thermostat. UtilityPRO TM

Programmable Thermostat

OPERATING INSTRUCTIONS

Installation Instructions

Transcription:

C O N T R O L S icomfort Residential Communicating Control System icomfort Touch Communicating Thermostat P R O D U C T S P E C I F I C AT I O N S Bulletin No. 210538 March 2012 Supersedes October 2011 The icomfort Touch Communicating Thermostat recognizes and connects to all icomfort -enabled products to automatically configure and control the system (based on user-specified settings) for the highest level of comfort, performance and efficiency. Also recognizes model and serial number information for icomfort -enabled products to simplify system setup. Advanced icomfort controls in specific heating and cooling units communicate information about various operating parameters to the thermostat to constantly maintain the most efficient operating conditions possible. Additional conventional (not icomfort -enabled) air quality comfort controls (PureAir Air Purification System, Healthy Climate Humidifiers, Humiditrol Enhanced Dehumidification Accessory, Healthy Climate Energy/Heat Recovery Ventilators) can be added to the system for a complete totalcomfort system. Conventional outdoor units (not icomfort -enabled) can easily be added and controlled by the icomfort Touch Communicating Thermostat. A simple easy-to-use menu-driven touchscreen allows complete system configuration. Scheduled maintenance alerts, system warnings and troubleshooting are also displayed in simple English on thermostat screen. Easy to read 5.7 in. screen (measured diagonally). A tabbed interface lists all programming options on the screen. Installer setup screens allow quick and simple system configuration without a manual, Installer can also run tests on complete system or individual components for easy maintenance and troubleshooting. Serial communications bus (RSBus), with less wiring than a conventional heating/cooling system, allows system communication. Uses 4-wire, 18-gauge standard thermostat wiring. Thermostat can be recess mounted on a wall (3-gang electrical box required). Subbase with terminal strip is furnished for easy installation. EQUIPMENT WARRANTY Five years in residential installations and one year in non-residential installations. Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details.

SYSTEM COMPONENTS icomfort Touch Communicating Thermosat Outdoor Sensor (furnished on all outdoor icomfort -enabled products) (Also available as an optional accessory) icomfort -enabled Air Conditioner XC21 (2-) or XC17 (1-) Heat Pump XP21 (2-) or XP17 (1-) RSBus icomfort -enabled Furnace SLP98V or SL280V (Variable Capacity Variable Speed Blower) icomfort -enabled Air Handler CBX40UHV or CBX32MV Variable Speed Blower CONTROL ORDERING INFORMATION Description icomfort Touch Communicating Thermostat Dimensions (H x W x D) - 5 x 6-3/8 x 1-1/4 in. Catalog No. 49W95 1 Optional Outdoor Sensor X2658 2 Discharge Temperature Sensor 88K38 1 The Optional Outdoor Sensor may be used with an icomfort equipped outdoor unit for a secondary (alternate) sensor reading. Optional Outdoor Sensor may be ordered for use with a conventional outdoor unit. 2 Required with Air Handler applications when using EVENHEATER option. Optional on all other applications for service diagnostics icomfort Communicating Control System / Page 2

RESIDENTIAL COMMUNICATING CONTROL SYSTEM SYSTEM COMPONENTS The complete icomfort control system consists of an icomfort Touch Communication Thermostat paired with an icomfort -enabled furnace and air conditioner or an icomfort -enabled air handler and heat pump outdoor unit (or furnace for dual-fuel operation). Indoor units must contain the icomfort control. A noncommunicating outdoor unit may be used (some system features will be reduced). FEATURED SYSTEM PRODUCTS icomfort Touch Communicating Thermostat Large full color touchscreen - no hidden buttons or doors. Temperature and humidity control (humidify/dehumidify). Sophisticated control and scheduling. Also controls conventional (not icomfort -enabled) products (includes standard thermostat terminal designations). Dave Lennox Signature Collection SLP98V Variable-Capacity, Variable-Speed Furnaces Energy Star qualified. 98% AFUE energy efficiency. Variable-capacity operation. Multi-position design. icomfort control. Precise Comfort technology. AirFlex technology. Fully insulated cabinet. SureLight Control delivers operation reliability. Silicon nitride igniter. Also available - SL280V Gas Furnace. Dave Lennox Signature Collection XC21 Two- Air Conditioners (SunSource -Ready) Energy Star qualified. Up to 20.5 SEER cooling efficiency. icomfort control. SilentComfort technology. Quiet operation, as low as 69 db. R-410A refrigerant. Dependable and efficient two-stage scroll compressor. SmartHinge louvered coil protection. Optimized for use with the Humiditrol whole-home dehumidification system. Also available - XC17 Single- Air Conditioner (SunSource -Ready). Dave Lennox Signature Collection XP21 Two- Heat Pumps (SunSource -Ready) Energy Star qualified Up to 19.0 SEER and 9.50 HSPF heating efficiency icomfort control. SilentComfort technology Quiet operation, as low as 67 db R-410A refrigerant Dependable and efficient twostage scroll compressor SmartHinge louvered coil protection Optimized for use with the Humiditrol whole-home dehumidification system Also available - XP17 Single- Heat Pump (SunSource -Ready). Dave Lennox Signature Collection CBX40UHV Variable-Speed Air Handlers 4-way multi-position design. icomfort control. Variable-speed blower motor. R-410A refrigerant compatible. Automatic comfort control for lower, summertime humidity levels. Anti-microbial drain pan resists the growth of mold and mildew. Healthy Climate MERV 16 high efficiency air filter factory installed. Includes knock-out for easy installation of Healthy Climate germicidal light. Also available - CBX32MV Variable-Speed Air Handler. Contents Control Ordering Information............. 2 Featured System Products.............. 3 Installer Setup..................... 7 System Components................. 2 User Settings..................... 4 icomfort Communicating Control System / Page 3

USER SETTINGS SCREEN (PROGRAM ON) INDOOR SETTINGS AND USER DASHBOARD current temp 70 humidity 45% (OK) s conditions set heat to 63 cool to 85 press for more set hold 1 hour 2 hours 8 hours 24 hours until next pgm. custom time set cancel weather humidity temperature settings current temp set 70 heat to 63 cool to 85 program is ON alerts fan settings system settings heat & cool cool only heat only off auto on circulate Indoor Conditions Large display of current temperature ( F or C) Current heating setpoint temperature (heat to) Current cooling setpoint temperature (cool to) Raise / Lower temperature setting arrows (up / down arrows) to set heating or cooling setpoints indefinitely (program off). If program is on screen displays adjustable set hold time (1, 2, 8, 24 hours, until next program or custom set time) Both setpoint temperatures and adjustment arrows are displayed if System is set to Heat/Cool mode. Humidity settings (humidity is 45% OK) System Mode (system is heating / cooling) Program Mode (program is off, program is on) Service Alerts (triangle symbol). Touch for details. Press for more displays Indoor Settings (and dashboard) screen. settings programs zones Temperature Settings Large display of current temperature ( F or C) Current heating setpoint temperature (heat to) Current cooling setpoint temperature (cool to) Raise / Lower temperature setting arrows (up / down arrows) to set heating or cooling setpoints indefinitely System Settings Heat & Cool Cool Only Heat Only Emergency Heat (if air handler or dual fuel system) Off Selecting Heat Only or Cool Only only displays those setpoints. Fan Settings Auto On Circulate Selecting other tabs on screen displays different Dashboard Tab screens. icomfort Communicating Control System / Page 4

USER SETTINGS USER DASHBOARD TABS Programs Tab Indoor Humidity Alerts Zones Tab (for future use) Weather Tab - Displays outdoor temperature if icomfort -enabled outdoor unit or optional outdoor temperature sensor is enabled (set in user setup) PROGRAMS programs press to turn the program schedule ON or OFF Edit Program mon all 7 days days to schedule set schedules for a group of days next mon - fri OR set schedules for a specific day cancel sat, sun tue wed thu fri sat sun press next to edit the schedule for all 7 days Set schedule for a group of days (all 7 days, mon - fri, sat - sun) or set schedule for each individual day (program ON) (program OFF) schedule for all 7 days do you want to view or edit the current program? view/edit do you want to restore the original energy saving program? restore time heat temp 6:00 AM 8:00 AM 5:00 PM 10:00 PM 70 62 70 62 cool temp 78 85 78 62 Program (Program On, Program Off) Current Program (View or Edit) Restore EnergyStar Program (Confirm or Cancel)? View Program the following program settings have been saved press a program to edit it press NEW to create a program mon, tue, wed, thu, fri, sat, sun (program ON) (program OFF) time heat cool 6:00 AM 70 75 Displays current program new 8:00 AM 62 85 5:00 PM 70 78 10:00 PM 62 82 fan auto auto auto auto press to edit fan press and hold a time button to turn an individual setting on/off auto auto auto auto cancel back Set time of day, heat temp., cool temp. and fan settings for days ed (four events per day) Skip an event if desired Restore EnergyStar Program Restores program to EnergyStar default comfort settings: Setting Time Heat Temp. Cooling Temp. Wake 6:00 am < 70 F > 78 F *Day 8:00 am Setback 8 F Setup 7 F Evening 6:00 pm < 70 F > 78 F *Sleep 10:00 pm Setback 8 F Setup 4 F *At least setback and setup temperatures. Left side of screen displays various help screens depending on which dashboard tab is ed first (Indoor Settings, Programs, Indoor Humidity, Alerts) Clean Screen (30 second timer for cleaning screen without affecting settings) Use Preferences (see User Preferences section for details) Returns to home screen icomfort Communicating Control System / Page 5

USER SETTINGS INDOOR HUMIDITY weather 45 humidity current humidity level is 45% (OK) settings 50 40 cooling comfort range programs alerts zones Set humidity or dehumidify levels (if equipped) Humidity adjustable from 15 to 45% relative humidity (RH) Dehumidify adjustable from 40 to 60% relative humidity (RH) ALERTS weather settings humidity Alert 3 of 3 Critical Alert Code: 29 AC reports: Over Temperature Protection 10/12/09 5:52 PM programs alerts zones service info next alert Press the Alert Icon on Home Screen (if program is running) to display system or device active alerts If program is not running, press Alert Icon on Dashboard Screen to display alerts. A red Critical Alert indicates that service is required for a major system component as soon as possible A yellow Service Alert indicates required maintenance (filter replacement, humidifier pad replacement, UV light replacement, PureAir Air Purification System servicing and Maintenance) Next Alert scrolls through available system alerts Remind Later allows a Service Alert to be postponed (1 day, 1 week, 1 month, 3 months or a custom time) USER PREFERENCES weather Time and Date Daylight Saving Time Circulate Fan ON Time Dealer Name Dealer Address Dealer Phone Number Dealer Email settings user settings humidity programs alerts zones To change a user setting, highlight a setting on the left and then press modify. modify back done User Setting Default Variable Settings Setting Time and Date Time/date elements screen) Daylight Saving Time Enabled Enabled, Disabled Circulate Fan ON Time 35% 15 to 45% (in 1% Dealer Name These may Keyboard input screen Dealer Address show installer input data but Dealer Phone owner can Dealer Email change Dealer Website Language Displayed English English Temperature Display Scale F Fahrenheit ( F) or Celsius ( C) Clock Format 12 Hour 12 Hour, 24 Hour Screen Lock-out Unlocked Unlocked, Partially Locked, Fully Locked Backlight Setting Always On Power Save, Always On Backlight Intensity 100% 20 to 100% (in 20% Outdoor Temp Display Disabled Disabled, Enabled Indoor Humidity Display Enabled Disabled, Enabled Filter 1 Timer Disabled Disabled, 3, 6, 12, 24 Filter 2 Timer Disabled Months or Custom Time Humidifier Pad Timer Disabled UV Bulb Timer Disabled Maintenance Timer Disabled PureAir Timer Disabled icomfort Communicating Control System / Page 6

INSTALLER SETUP SYSTEM DISCOVERY SYSTEM DISCOVERY IN PROGRESS SETUP - SYSTEM SETTINGS setup setup Thermostat 1 tests Use this Thermostat? system settings Time and Date Daylight Saving Time Circulate Fan ON time Dealer Name Dealer Address Dealer Phone Number Dealer Email To view/edit a setting, highlight it, then press edit. edit back Current Value: (35%) next step press here After power is applied to the thermostat for the first time, it checks the system for installed communicating devices, the System Discovery progress screen is displayed on the thermostat; followed by the Use this thermostat? screen. Active Critical Alert Code: 31 AIR HANDLER reports: Lost Communication with THERMOSTAT Latest occurrence: 8/23/09 1:57 PM press for more critical alert close During the setup process, alerts may be displayed to inform the installer of any information that affects the setup process. Use the up / down arrows to scroll through available settings. Right side of screen displays the current value of each setting. Installer System Settings and Default Setting System Setting Time and Date Daylight Saving Time Circulate Fan ON Time Dealer Name Range / Condition Default Setting Modify with Time and Date Screen and arrow buttons (see example) Enabled/ Enabled Disabled 15 to 45% 35% alphanumeric Lennox Dealer Address - - - characters Dealer Phone 1-800-9-LENNOX Number Dealer Email - - - Dealer Website www.lennox.com Time and Date Screen setup Time and Date Up / Down Arrows Keyboard tool 10 :19 AM Oct 15 2009 adjust cancel save icomfort Communicating Control System / Page 7

INSTALLER SETTINGS Add / Remove / Modify Non-Communicating Devices System Devices setup setup system devices HP XP19 060 230 06 5809K00015 AIR HANDLER CBX32MV 60 5809K00020 THERMOSTAT 49W95 A109K00139 SYSTEM Add or Remove Non communicating equipment? back yes next step system devices HP XP19 060 230 06 5809K00015 AIR HANDLER CBX32MV 60 5809K00020 THERMOSTAT 49W95 A109K00139 SYSTEM to adjust a device, highlight it, then press edit edit back about reset ALL next step Press yes to access non-communicating device list screen setup non communicating device list HUMIDIFIER DEHUMIDIFIER UV LIGHT edit back to adjust a setting, highlight it, then press edit Current Value: (Not Installed) Use up/down arrow buttons to highlight and modify non-communicating device Outdoor Unit Type (Not Installed, 1 AC, 2 AC) Humidifier (Not Installed, Bypass (24 VAC), Power (120 VAC), Bypass and Power) Dehumidifier (Not Installed, Humiditrol, Auxiliary Dehumidifier) UV Light (Not Installed, UV Light) NOTE - If outdoor unit is non-communicating type, screen will display parameters to set (Outdoor Unit Capacity, 18 to 60 kbtu in 1 kbtu increments, default is 60 kbtu) Use up / down arrow buttons to device. Press edit button to modify device settings. Pressing about displays equipment information depending on type (name, model, serial number, number of stages, cooling btuh, blower cfm range, software version, outdoor air temp sensor installed, etc.) NOTE - Reset ALL resets all devices back to original factory default settings. Each individual device can be also reset to factory settings on the ed equipment screen. Equipment Name - Press edit button to change equipment name, use keyboard tool to change Air Conditioner Equipment Name Compressor Short Cycle Delay (60 to 300 sec. in 60 sec. increments, default is 300 sec.) Heat Pump Equipment Name Compressor Short Cycle Delay (60 to 300 sec. in 60 sec. increments, default is 300 sec.) Defrost Termination Temp (50 to 100 F in 10 F increments, default is 50 F) Compressor Shift Delay (On/Off) icomfort Communicating Control System / Page 8

INSTALLER SETUP System Devices (Continued) Furnace: Equipment Name Heating Airflow Control Type - Selections available if Discharge Air Temperature Sensor is installed (Fixed cfm, fixed Discharge Air Temperature) With Discharge Air Temperature: Low Heating Discharge Air Temperature - Available if Discharge Air Temperature Sensor is installed (110 to 140 F in 5 F increments, default is 120 F) High Heating Discharge Air Temperature - Available if Discharge Air Temperature Sensor is installed (120 to 150 F in 5 F increments, default is 135 F) With Fixed cfm: Low Heating Airflow (325 to 1280 in 25 cfm increments High Heating Airflow (300 to 1805 in 25 cfm increments Low Cooling Airflow (300 to 1390 in 25 cfm increments High Cooling Airflow (300 to 2190 in 25 cfm increments Airflow Profile Cooling: A. On (50% for 30 sec., 82% for 7.5 min.); Off (50% for 30 sec.) B. On (82% for 7.5 min.); Off (No delays) C. No delays; Off (45 sec. delay) D. No delays Low HP Airflow (300 to 1400 cfm in 25 cfm High HP Airflow (300 to 1400 cfm in 25 cfm Continuous Indoor Blower Airflow (300 to 1400 in 25 cfm Humidification Airflow (300 to 1400 cfm in 25 cfm increments, default is 500 cfm) Dehumidification Airflow (60 to 80% RH in 1% Heating Indoor Blower Off Delay (60 to 80 sec. in 10 sec. increments default is 90 sec.) Heating Indoor Blower On Delay (15 to 45 sec. in 5 sec. increments, default is 45 sec.) Cooling Indoor Blower Off Delay (0 to 30 sec. in 2 sec. increments, default is 0 sec.) Cooling Indoor Blower On Delay (0 to 10 sec. in 5 sec. increments, default is 2 sec.) HP Indoor Blower Off Delay (0 to 60 sec. in 5 sec. increments, default is 45 sec.) HP Indoor Blower On Delay (0 to 30 sec. in 5 sec. increments, default is 0 sec.) All furnace default airflow settings are dependent on furnace capacity. NOTE - Humidification and Dehumidification Airflow settings are only viewable if those non-communicating products are added during setup. Air Handler Equipment Name Electric Heating Airflow (1560 to 2150 cfm in 5 cfm Low Cooling Airflow (450 to 2150 cfm in 5 cfm High Cooling Airflow (450 to 2150 cfm in 5 cfm Airflow Profile Cooling: 1. No Delays 2. On (No delays); Off (45 sec. delay) 3. On (82% for 7.5 min.); Off (No delays) 4. On (50% for 30 sec., 82% for 7.5 min.); Off (50% for 30 sec.) Low HP Airflow (450 to 2150 cfm in 5 cfm High HP Airflow (450 to 2150 cfm in 5 cfm Continuous Indoor Blower Airflow (450 to 2150 in 10 cfm Humidification Airflow (450 to 2150 cfm in 5 cfm Dehumidification Airflow % (60 to 80% RH in 1% Heating Indoor Blower OFF Delay (0 to 10 sec. in 1 sec. increments, default is 10 sec.) Heating Indoor Blower ON Delay (0 to 5 sec. in 1 sec. increments, default is 0 sec.) Cooling Indoor Blower OFF Delay (0 to 30 sec. in 2 sec. increments, default is 0 sec.) Cooling Indoor Blower ON Delay (0 to 10 sec. in 1 sec. increments, default is 2 sec.) HP Indoor Blower OFF Delay (0 to 60 sec. in 5 sec. increments, default is 45 sec.) HP Indoor Blower ON Delay (0 to 30 sec. in 5 sec. increments, default is 0 sec.) All air handler default airflow settings are dependent on furnace capacity. icomfort Communicating Control System / Page 9

INSTALLER SETTINGS Thermostat: Temp. Reading Calibration (-5 to 5 F, default is 0 F) Humidity Reading Calibration (-10 to 10 F, default is 0 F) System Equipment Name Filter 1 Timer Selection (Calendar or Run Time) Filter 2 Timer Selection (Calendar or Run Time) UV Bulb Timer Selection (Calendar or Run Time) Humidifier Pad Timer Selection (Calendar or Run Time) PureAir Timer Selection (Calendar or Run Time) Smooth Setback Recovery (Enabled/Disabled) Electric Heat Control Mode (Standard/EvenHeat) Gas Heat Control Mode (d/modulating) Auto-Changeover Temp. Deadband (3 to 9 F, default is 5 F) Max. Heat Setpoint (40 to 90 F, default is 90 F) Min. Cool Setpoint (60 to 99 F, default is 60 F) Heat Cool s Locked In (Enabled/Disabled) 1st Differential (0.5 to 3 F, default is 0.5 F) 2nd Differential (0.5 to 8 F, default is 1.5 F) 3rd Differential (0.5 to 8 F, default is 2 F) 4th Differential (0.5 to 8 F, default is 2.5 F) 5th Differential (0.5 to 8 F, default is 3 F) 6th Differential (0.5 to 8 F, default is 3.5 F) d Delay Timers (Enabled/Disabled) 2nd through 6th Delays (5 to 120 min. in 5 min. increments, default is 20 min.) Locked in 2nd HP by Outdoor Temp (off, 40 F, 45 F, 50 F, 55 F) Balance Point Control (enabled/disabled) Defrost Target Discharge Temp (50 to 60 F in 1 F increments, default is 55 F) EvenHeater Discharge Temp (80 to 130 F in 1 F increments, default is 85 F) Dehumidification Control Mode (Display Only, Basic, Precision) Humidification Control Mode (Display Only, Dewpoint Control) OK/Humid Boundary (45 to 60 F in 1 F increments, default is 50 F NOTE - Depending on type of system (conventional heating/cooling or heat pump system) not all system settings will be displayed. TESTS A variety of system tests can be performed by the installer. Press the tests tab, then press start to begin system testing. press start button below to begin system testing start setup tests equipment tests to run TEST ALL ed tests Blower HP Heat 1st HP Heat 2nd Defrost Now Cooling 1st Cooling 2nd skip tests alerts diagnostics EXIT TEST ALL is the default. You can also test equipment individually. Use up / down arrow buttons to device. Then press, then start on the next screen to test all or individual equipment. setup tests equipment tests to run TEST ALL Blower HP Heat 1st HP Heat 2nd Defrost Now Cooling 1st Cooling 2nd remove ed tests TEST ALL alerts diagnostics EXIT start The remove button allows to you remove individual equipment from the TEST ALL list if you only want to test certain equipment. Press the start button to begin testing. CURRENT TEST: Blower Check Blower Operation cancel next When a test is running, a status screen will show which test is being run. A Testing Process is Finished confirmation screen will appear when testing is complete. NOTE - The tests feature is not available until after setup has been completed at least once. icomfort Communicating Control System / Page 10

INSTALLER SETTINGS DIAGNOSTICS Allows installer to run diagnostic tests on any icomfort - enabled product. device to run diagnostics on HP XP19 060 230 06 5809K00015 AIR HANDLER CBX32MV 60 5809K00020 run diagnostics on: diagnostics Use the up/down arrow buttons to highlight and press and start to run diagnostics on ed equipment. Screen will display DIAGNOSTICS IN PROGRESS.. and will show a list of values and conditions. type of device to run diagnostics on HP XP19 060 230 06 5809K00015 AIR HANDLER CBX32MV 60 5809K00020 run diagnostics on: HP remove start diagnostics HP Diagnostics Line Voltage 24VAC Voltage Y1 Output PSC Fan Relay ECM Fan 1 ECM Fan 2 Y2 Solenoid 220 volts 24 volts On Closed On On On done Use the up/down arrow buttons to scroll through the available information. EQUIPMENT The equipment tab allows the same equipment setting adjustments as in the setup tab, see System Devices, page 4.

REVISIONS Sections Warranty Description of Change Added warranty description. Visit us at www.lennox.com For the latest technical information, www.lennoxdavenet.com Contact us at 1-800-4-LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 2012 Lennox Industries, Inc.