The Worcester CondenseSure. An innovative solution to prevent freezing condensate NEW

Similar documents
CondenseSure Siphon INSTALLATION INSTRUCTIONS UK/IE GREENSTAR EXTERNAL 500ML SIPHON

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

Greenstar oil-fired. heating and hot water solutions. Product Guide 2018

Bosch EasyControl. Smart heating and hot water control made Easy

Greenstar Xtra. Installation instructions. Passive flue gas heat recovery device. For use with Greenstar CDi Compact, Si Compact and i combi boilers

Greenstar System Filter

Bosch EasyControl. Smart heating and hot water control made Easy

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

GREENSTAR HIGHFLOW 440/550CDi

GREENSTAR HIGHFLOW 440/550CDi

Product Guide Gas-fired and solar thermal. heating and hot water solutions NEW. Greenstar Comfort controls

Greenstar regular gas-fired condensing wall mounted boiler range. Technical and Specification Information

Greenstar 12i/24i System

GREENSTAR CAMRAY UTILITY & UTILITY SYSTEM

Greenstar 25Si/30Si USER INSTRUCTIONS & CUSTOMER CARE GUIDE

INSTALLATION INSTRUCTIONS FOR FLUE KIT

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

TWIN CHANNEL PROGRAMMER FITTING AND OPERATING INSTRUCTIONS

GREENSTAR CAMRAY EXTERNAL & EXTERNAL SYSTEM12/18, 18/25, 25/32


GREENSTAR CDi WALL HUNG RSF GAS-FIRED CONDENSING COMBINATION BOILER

Greenstar 12i system / 24i system

Technical and Specification Information. Greenstore SC Cylinder series Greenstore TC Cylinder series. Greenstore Cylinder series NEW

Greenstar 24i junior / 28i junior

SEDBUK Band A Gas Condensing Boilers. The Greenstar range of high efficiency gas condensing boilers from Worcester

Contacts: Potterton. For latest prices and delivery to your door visit MyTub Ltd

Your heating and hot water in safe hands. Gas-fired boilers

RT 10 RT 10 INSTALLATION, USER INSTRUCTIONS & CUSTOMER CARE GUIDE. Order no

Installation instructions. Pump Group. For wall hung gas-fired condensing boiler GB162-50/65/80/ TD UK/IE (2014/09)

Vote for your Installer of the year at. 9/14, 14/19 & 19/24CBi. Worcester supports the Benchmark code of practice

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

24CDi, 28CDi & 35CDi II COMBI

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

GREENSTAR CDi CLASSIC REGULAR ErP

Product Guide Oil-fired and solar thermal. heating and hot water solutions. Includes ErP ratings

DANESMOOR FRONT SERVICE (FS) 12-18, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Room-temperature (economy/night) unit TR 212 E

WC2 & WC3 Installation & Maintenance Instructions

Greenstore unvented cylinder series. Technical and Specification Information. Greenstore unvented cylinder series

GREENSTAR HEATSLAVE II EXTERNAL 12/18, 18/25 & 25/32

Sirius FS. Working towards a cleaner future

USER INSTRUCTIONS & CUSTOMER CARE GUIDE HIGHFLOW 400 ELECTRONIC SERIES

The Ideal Logic. Combination, Heat Only and System Boilers. Heating Solutions.

The Greenstar CDi gas-fired condensing combi boiler series. Technical and specification information

PROFESSIONAL INSTALLER OFFER ONLY. cash-back on a Worcester Greenstar boiler for your own home. BBT4577e Installers Cashback 8pp A5 Lft MAY17.

AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE

Vote for your Installer of the year at HEATSLAVE

Baxi Combi HE Range. Baxi Combi HE. Keeping Britain Warm

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

FR 10 INSTALLATION & USER INSTRUCTIONS INTELLIGENT ROOM THERMOSTAT

GREENSTAR HEATSLAVE II ErP+ 12/18, 18/25 & 25/32

Greenstar FS 30CDi ErP & 42CDi ErP Regular

GREENSTAR i SYSTEM USER MANUAL WALL HUNG RSF GAS FIRED CONDENSING SYSTEM BOILER FOR CENTRAL HEATING SYSTEMS UK/IE (2013/08)

Baxi Bermuda BBU HE condensate pipe installation. B/BBUCondensate/0710/V1

Kenya s Official Distributor of GutterFlow Products

DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

AIR ADMITTANCE VALVES FOR DOMESTIC PROPERTIES Guidance Notes

GREENSTAR Ri ErP. User instructions UK/IE. Wall hung RSF gas fired condensing regular boiler. For central heating systems

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

Instructions for Use Installation and Servicing

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

ecotec plus 937 Power store high efficiency combination boiler

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER

Multipoint Technical Data

Logic+ Combi

T UNI 7000 F. Operating instructions For the user (2006/05) AU/GB

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

ecotec plus New high efficiency condensing combination and system boiler ranges

WALL HUNG RSF GAS FIRED CONDENSING REGULAR BOILER

Stroma Certification Ltd

USER GUIDE LOGIC HEAT H

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

Operating instructions

SINGLE-CHANNEL PROGRAMMER FITTING AND OPERATING INSTRUCTIONS

Compact. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

NEW. Innovative heating controls. Commercial boiler control systems. Control 8000 & MX25

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

Greenspring gas-fired condensing wall mounted continuous flow water heater. Includes ErP ratings. Technical and Specification Information

BLC1.A Boiler Load Compensator

Combi Konverter Solar System

ENERSTORE. Vented Hot Water Storage System INSTRUCTIONS PLEASE LEAVE WITH HOUSEHOLDER

Saturn Booster PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USE AND KEEP THEM FOR FUTURE REFERENCE

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

AquaCyl solar system solar water heating solution for the larger home with greater hot water demand (2 or more bathrooms in use simultaneously)

Greenstar i ErP. Installation, commissioning and servicing instructions. Wall hung RSF gas fired condensing combi boiler

Installation instructions

INDEPENDENT COMBINATION & SYSTEM BOILERS.

Flue Dilution Fans. Specialists in Air Movement Technology. IMPROVED GBDF MK5 Now includes a Pressure Safety Switch and easier Electrical Connections

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

User s Operation Instructions & Important Warranty Information

systemate 2000 fully integrated thermal store

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve. Models covered: CAS SHCVO C, COB SHCVO C, ORB SHCVO C,

Greenstar Heatslave II oil-fired condensing combi boiler range. Includes ErP ratings. Technical and Specification Information

Cistern-fed water heating

SEDBUK & HARP. the complete range of oil and gas fired condensing boilers. Warmflow Boilers HIGH EFFICIENCY

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

Transcription:

The Worcester CondenseSure An innovative solution to prevent freezing condensate NEW

Prevent freezing condensate pipework with the CondenseSure Auxiliary Siphon With climate change and extreme weather variations becoming increasingly common, and very cold winters with temperatures as low as -20 C being experienced, installation practices such as externally run condensate discharge pipework are now being questioned. In the early days of condensing boilers, when the installation standards were being created, there was no great concern that externally routed condensate discharge pipework would present major problems. Whilst average temperatures have not changed significantly, the extremes of temperatures have. The winter of 2010/2011 was the coldest since accurate records began with the CET (Central England Temperature) for the month of December averaging -1 C. Consequently there were many installations that although installed to British Standards, still experienced a frozen condensate pipe with the subsequent interruption to the boiler operation. The industry has now strengthened and re-enforced the advice on condensate discharge pipe termination, strongly recommending the internal waste system termination route as the most preferable*. However if this is not possible, then externally installed and terminated discharge pipework is permissible providing the following criteria are met. The pipe should be run internally as far as possible before going externally and the pipe diameter should be increased to a minimum of 30mm ID (typically 32mm OD) before it passes through the wall. During the winter of 2010/2011 temperatures of -17ºC were not uncommon. The external run should be kept as short as possible, taking the most direct and most vertical route to the discharge point, with no horizontal sections in which condensate might collect. The external pipe should be insulated using suitable waterproof and weatherproof insulation ( Class O pipe insulation is suitable for this purpose). www.directheatingsupplies.co.uk *Please note that internally run condensate drainage pipes in unheated areas such as lofts and garages etc. should also be treated as an external pipe.

An alternative and Sure solution The CondenseSure auxiliary siphon has been designed to allow a more flexible approach to boiler siting and enable condensate discharge pipes to be installed externally when an internal route is not practical. The large capacity of the CondenseSure auxiliary siphon increases condensate discharge volume, significantly reducing or even eliminating the risk of freezing. CondenseSure has been extensively tested under simulated extreme weather conditions and proved its effectiveness in preventing frozen condensate at -15ºC for a sustained period of 48 hours. A universal fitting for new and existing installations Although developed specifically for Worcester Greenstar gas- and oil-fired boilers, the Worcester CondenseSure has the added advantage of being able to be fitted to any make of condensing boiler for both new and retrofit installations. CondenseSure can provide a simple solution which eliminates the need for re-siting both the new boiler and the system pipework when replacing an existing noncondensing appliance. CondenseSure can easily be fitted to existing installations to provide peace of mind in extreme weather conditions. The CondenseSure insulating jacket helps to retain the temperature of the condensate.

CondenseSure principle of operation Within most condensing boilers there is an internal siphon which holds around 100ml of condensate before being released down the condensate discharge pipe. A typical A-rated condensing boiler will generate up to 2 litres of condensate an hour (dependant on output and temperature) and this will result in the in-built siphon discharging approximately every 3 minutes. With this frequency of discharge it is unlikely that the condensate pipework is ever empty of condensate, consequently increasing the potential for freezing of the pipework in prolonged sub-zero temperatures. The CondenseSure siphon connects to the boiler condensate discharge outlet and collects the condensate into a larger volume before releasing it into the discharge pipe. With this expanded siphonic operation, the discharge from the CondenseSure is every 15 to 20 minutes, resulting in: Increased velocity and flow rate With only 3 to 4 siphonic actions per hour, the condensate pipework is empty for longer Significantly decreased or even eliminated freezing potential. CondenseSure clips onto the 22mm heating flow pipe using the free heat to raise the condensate temperature. Features No power consumption No moving parts Can be installed on new or existing installations Can be attached to 22mm heating flow pipework Can be installed under the boiler or wall mounted away from the appliance No electrical connections No pipe insulation needed Benefits No electrical wiring connection or supply needed, meaning zero running costs No failure of components Suitable for any gas- or oil-fired condensing boilers Uses free energy from the pipe to heat the condensate Flexibility No electrician needed Cost saving and aesthetically pleasing Product info Part number 7 716 192 746

Ease of installation CondenseSure has been designed with ease of installation in mind and is suitable for most boiler applications. For maximum effectiveness it should be installed immediately beneath the boiler where it is clipped on to the boiler s heating flow pipe and connected to its siphonic trap. If this is not practical, CondenseSure can be wall-mounted away from the boiler and connected to a 32mm condensate discharge pipe. However, this will sacrifice the benefit of warming the condensate prior to discharge and therefore slightly reduce its performance. 1 3 2 4 2 5 Siphon trap 6 7 Fitting to a combi boiler: CondenseSure External pipework 3000mm max. 2.5º fall min. 32mm OD pipe 1. Foam backing with double-sided tape 2. Siphon mounting screws 3. Siphon body 4. Foam insert (used with regular or system boilers) 5. Foam cover 6. CH flow pipe 7. Boiler DHW outlet pipe A typical installation using CondenseSure CondenseSure installation parameters The CondenseSure will protect an externally run condensate discharge pipe from freezing for 48 hours at -15 C, providing the following installation parameters are met: The externally run pipe length does not exceed 3 metres There is a fall on the discharge pipe of at least 2.5 degrees The discharge pipe diameter is not less than 32mm in diameter. Additional installation considerations include: Keeping any external pipework as short as possible Minimising the number of bends and connections Removal of burrs after cutting pipe Removal of surplus solvent from the interior of the pipe. CondenseSure has no working parts to breakdown, does not use any energy and has no electrical connections, so there is no Part P requirement. Whilst it is not necessary to insulate the pipework, it may be a consideration if longer length pipework is required or if lower external temperatures are expected.

Technical Helpline (Pre & Post Sales) Tel: 0844 892 3366 Fax: 01905 752741 Enquiries Email: service.mailbox@uk.bosch.com or telephone 0844 892 3000 Literature Email: literature@uk.bosch.com or download instantly from our website or telephone 0844 892 9800 www.worcester-bosch.co.uk In partnership with Part No. 8 716 116 559 A 09/12 Worcester, Bosch Group, Cotswold Way, Warndon, Worcester, WR4 9SW