CondenseSure Siphon INSTALLATION INSTRUCTIONS UK/IE GREENSTAR EXTERNAL 500ML SIPHON

Similar documents
INSTALLATION INSTRUCTIONS FOR FLUE KIT

Greenstar System Filter

The Worcester CondenseSure. An innovative solution to prevent freezing condensate NEW

Installation instructions. Pump Group. For wall hung gas-fired condensing boiler GB162-50/65/80/ TD UK/IE (2014/09)

Greenstar Xtra. Installation instructions. Passive flue gas heat recovery device. For use with Greenstar CDi Compact, Si Compact and i combi boilers

GREENSTAR i SYSTEM USER MANUAL WALL HUNG RSF GAS FIRED CONDENSING SYSTEM BOILER FOR CENTRAL HEATING SYSTEMS UK/IE (2013/08)

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

WALL HUNG RSF GAS FIRED CONDENSING REGULAR BOILER

Installation instructions

Greenstar 12i/24i System

GREENSTAR Ri USER INSTRUCTIONS UK/IE WALL HUNG RSF GAS FIRED CONDENSING REGULAR BOILER FOR CENTRAL HEATING SYSTEMS a (2010/10)

Greenstar 25Si/30Si USER INSTRUCTIONS & CUSTOMER CARE GUIDE

GREENSTAR HIGHFLOW 440/550CDi

Greenstar FS 30CDi ErP & 42CDi ErP Regular

Room-temperature (economy/night) unit TR 212 E

GREENSTAR i JUNIOR USER INSTRUCTIONS UK/IE WALL HUNG RSF GAS FIRED CONDENSING COMBINATION BOILER

GREENSTAR CDi CLASSIC REGULAR ErP

GREENSTAR HIGHFLOW 440/550CDi

WALL HUNG RSF GAS FIRED CONDENSING COMBINATION BOILER GREENSTAR 24i Junior/28i Junior

Bosch EasyControl. Smart heating and hot water control made Easy

Greenstar 12i system / 24i system

FR 10 INSTALLATION & USER INSTRUCTIONS INTELLIGENT ROOM THERMOSTAT

GREENSTAR Ri ErP. User instructions UK/IE. Wall hung RSF gas fired condensing regular boiler. For central heating systems

Bosch EasyControl. Smart heating and hot water control made Easy

GB162 Concentric Horizontal Vent Kit

RT 10 RT 10 INSTALLATION, USER INSTRUCTIONS & CUSTOMER CARE GUIDE. Order no

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

GREENSTAR HEATSLAVE II EXTERNAL 12/18, 18/25 & 25/32

GREENSTAR HEATSLAVE II ErP+ 12/18, 18/25 & 25/32

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat


Greenstar 24i junior / 28i junior

GREENSTAR CDi WALL HUNG RSF GAS-FIRED CONDENSING COMBINATION BOILER

Installation and maintenance instructions

GREENSTAR CAMRAY UTILITY & UTILITY SYSTEM

GREENSTAR Ri ErP + User instructions UK/IE. Wall hung RSF gas fired condensing regular appliance. For central heating systems

T UNI 7000 F. Operating instructions For the user (2006/05) AU/GB

Greenstar Si Compact ErP

Greenstar oil-fired. heating and hot water solutions. Product Guide 2018

GREENSTAR CAMRAY EXTERNAL & EXTERNAL SYSTEM12/18, 18/25, 25/32

Operating instructions

Product Guide Gas-fired and solar thermal. heating and hot water solutions NEW. Greenstar Comfort controls

24CDi, 28CDi & 35CDi II COMBI

METIS. Installation instructions. Riser rail kit INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER.

Outdoor kit. Models: RTG 199HE / RTG 199ME. Installation Instructions

Vote for your Installer of the year at. 9/14, 14/19 & 19/24CBi. Worcester supports the Benchmark code of practice

TWIN CHANNEL PROGRAMMER FITTING AND OPERATING INSTRUCTIONS

NEW. Innovative heating controls. Commercial boiler control systems. Control 8000 & MX25

GREENSPRING CWi47 INSTALLATION AND OPERATING INSTRUCTIONS WALL HUNG RSF GAS CONDENSING INSTANTANEOUS WATER HEATER FOR MAINS FED DOMESTIC HOT WATER

ferroli Boiler Replacement Maxima 35C- Modena HE

Users manual. Buderus /29/43/60 and Buderus T25/29T25 H/V. Wall-mounted condensing gas boiler. For the user

Power flushing and protecting your heating system can increase efficiency by at least 25%.

CEILING FED RISER RAIL KIT. Installation Guide. tritonshowers.co.uk/digital

Connecting cable. Installation instructions (2018/04) US

Installation and maintenance instructions

Dene Bath Shower Mixer

DANESMOOR FRONT SERVICE (FS) 12-18, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Wall Hung Boiler Room Thermostat OR30 OT Thermostat

Users Manual. Gas wall hung Boiler condensing Buderus /S. Please read thoroughly before operating the unit

POWER SHOWERS Models 4500M 5002M 4500T 5002T

Operating instructions

INSTALLATION, COMMISSIONING AND SERVICING INSTRUCTIONS FOR OPEN VENTED & SEALED CENTRAL HEATING SYSTEMS & INDIRECT MAINS FED DOMESTIC HOT WATER

Multi Box HP 10. Accessories, split air to water heat pump PRINT APPROVAL 1 NOVEMBER Installation instructions (2012/11)

Vote for your Installer of the year at HEATSLAVE

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

IMAGINATION SOLAR LTD. Installation Guide B1. Planning the Plumbing and Wiring

USER INSTRUCTIONS & CUSTOMER CARE GUIDE HIGHFLOW 400 ELECTRONIC SERIES

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

SINGLE-CHANNEL PROGRAMMER FITTING AND OPERATING INSTRUCTIONS

Bath Shower Mixer

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

Operating instructions

CROMO manual mixer shower

DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Greenstar regular gas-fired condensing wall mounted boiler range. Technical and Specification Information

AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE

Back to back. Cascade Venting System for RTG 199HE. Basic Set for units 1 and Installation instructions

GREENSTAR Ri INSTALLATION, COMMISSIONING AND SERVICING INSTRUCTIONS WALL HUNG RSF GAS FIRED CONDENSING BOILER

GENERAL FITTING GUIDE THERMOSTATIC BAR SHOWER MIXER with RIGID RISER KIT

THERMOSTATIC SHOWER VALVE

Greenstar FS 30CDi ErP & 42CDi ErP Regular

Operating Instructions

Installation Instructions

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

WC2 & WC3 Installation & Maintenance Instructions

en-us Use and Care Manual, Installation Instructions Washer WAT28400UC

Greenstar i ErP. Installation, commissioning and servicing instructions. Wall hung RSF gas fired condensing combi boiler

air pump 2700/4500 ? 2YEAR GUARANTEE UK AIRPUMP _33435 CASC /10/ :16 Page 1

Alpha CombiMax 350 and 600

Installation, Operating and Servicing Instructions. Silverlink 600 Electric Pasta Boilers PB33, PB66

MANUAL MIXER SHOWER. Installation and operating instructions. Installers please note these instructions are to be left with the user CAUTION!

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A

Stainless Steel Chimney Extractor

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Side by side. Cascade Venting System for RTG 199HE. Extension Set for units 3 or Installation instructions

Gas Instantaneous Water Heater

Cyrene. Installation instructions. Fixed showerhead kit. Installers please note these instructions are to be left with the user.

8707T Includes seat. 8745T Includes Bowl

Transcription:

INSTALLATION INSTRUCTIONS GREENSTAR EXTERNAL 00ML SIPHON CondenseSure Siphon ALL GREENSTAR GAS AND OIL COMBINATION, SYSTEM AND REGULAR CONDENSING BOILERS 708010-00.1Wo UK/IE 70 80 10 (01/0)

CONTENTS CONTENTS 1 Symbols and safety precautions................. 1.1 Explanation of symbols.................... 1. Fitting and modifications................... General information............................1 Condensesure siphon...................... Siphon kit parts.......................... Mounting the siphon............................1 Mounting options..........................1.1 Close coupled to the boiler..................1. Wall mounted.............................1. Siphon connections....................... 1 SYMBOLS AND SAFETY PRECAUTIONS 1.1 EXPLANATION OF SYMBOLS WARNING SYMBOLS Safety instructions in this document are framed and identified by a warning triangle which is printed on a grey background. Signal words indicate the seriousness of the hazard in terms of the consequences of not following the safety instructions. NOTICE indicates possible damage to property or equipment, but where there is no risk of personal injury. CAUTION indicates possible personal injury. WARNING indicates possible severe personal injury. IMPORTANT INFORMATION Notes contain important information in cases where there is no risk of personal injury or material losses and are identified by the symbol shown on the left. They are bordered by horizontal lines above and below the text. ADDITIONAL SYMBOLS Symbol Meaning 1. a numbered step in an action sequence B a step in an action sequence Cross reference to another part of the document a list entry a list entry (second level) Table 1 Additional symbols 1. FITTING AND MODIFICATIONS Only a competent engineer can fit the CondenseSure siphon, in accordance with the Gas Safety (Installation and Use) Regulations. Condensate pipe work should be routed and installed as per the instructions in the boiler installation manual. Any misuse or unauthorised modifications to the boiler, flue or associated accessories and heating system will invalidate the warranty. Do not modify the boiler or flue system in any way. Worcester, Bosch Group accepts no liability arising from any such actions. This does not affect your statutory rights. GENERAL INFORMATION.1 CONDENSESURE SIPHON The Worcester CondenseSure siphon has been designed and tested for installation with a Greenstar gas or oil condensing boiler. The siphon will prevent the freezing of a three metre long mm diameter straight uninsulated externally run condensate discharge pipe at external weather temperatures of up to -1 C. Tests over a sustained period of 8 hours at -1 C revealed that the condensate pipe did not freeze under these conditions when the siphon was installed around the central heating pipe, (as demonstrated in the installation section). The condensate discharge pipe must have a fall of at least.. To maximise the effectiveness of this product the installer should: Keep the external pipework as short as possible. Ensure a fall of at least. over horizontal sections. Minimise the number of bends and connectors. Remove burrs after cutting pipe. Remove surplus solvent from the interior of the pipe. There is no benefit to be gained by installing a CondenseSure Siphon in a boiler installation, oil or gas, that already incorporates a condensate pump. This also includes the Greenstar Highflow and Greenstar CDi FS (Floor Standing) boilers that have a built-in condensate pump. 70 80 10 (01/0)

GENERAL INFORMATION. SIPHON KIT PARTS The CondenseSure siphon kit comprises the following items: 7 8 Fig. 1 [1] [] [] [] [] [] [7] [8] 708010-01.1Wo 1 CondenseSure siphon kit Foam backing with double-sided tape Foam insert 90 Elbow with short rubber connector Mounting kit Longer rubber connector Foam cover Installation manual Siphon body 70 80 10 (01/0) OVERALL DIMENSIONS The overall dimensions of the siphon assembly are: 17mm wide x 1mm high x 11mm deep.

MOUNTING THE SIPHON MOUNTING THE SIPHON.1 MOUNTING OPTIONS The CondenseSure siphon is designed to be mounted under a condensing boiler. The siphon is designed to clip around the CH flow pipe from the boiler and thereby use some of the heat from that pipe to warm the condensate. The siphon can also be mounted on the wall, away from the boiler, in the condensate pipe work, however the effectiveness of the unit is slightly reduced. The siphon can be mounted in one of two ways: Close coupled to a combination, system or regular boiler. Wall mounted. 1 1...1.1 CLOSE COUPLED TO THE BOILER Fit the siphon directly underneath the boiler and connect into the boiler s siphon discharge pipe. B Fit the top and bottom mounting brackets to the siphon body, do not tighten the screws completely. Allow the brackets to slide on the screws. B Fit the top elbow to the siphon. B Fit the siphon on the CH flow pipe and ensure the siphon clips in place on the pipe. B Position the siphon so that the top elbow coincides with the boiler s siphon discharge pipe. B Mark through the mounting brackets on to the wall. B Slide the siphon down the pipe and drill suitable mounting holes in the wall. B Fit the wall plugs into the mounting holes. B Slide the siphon back up the pipe into the mounting position. 1. Remove the backing off the double-sided tape on the foam backing (1) and slide the foam behind the pipes in-line with the siphon.. Using the two screws provided, attach the siphon to the wall. Tighten the mounting screws, top and bottom, on the siphon body.. For System and Regular boilers, ensure that the foam insert () is fitted to the foam cover () and mount the cover over the siphon. For Combi boilers remove the foam insert () from the foam cover () and mount the cover over the siphon. 7 Fig. Fitting to a combination boiler [1] Foam backing with double-sided tape [] Siphon mounting screw [] Condense Sure siphon body [] Foam insert [] Foam cover [] Siphon mounting screw [7] CH flow pipe [8] Combination boiler DHW outlet pipe 1. 7 8 1... 708010-0.1Wo 708010-0.1Wo Fig. System and regular boilers 70 80 10 (01/0)

MOUNTING THE SIPHON.1. WALL MOUNTED If it is not convenient or possible to mount the siphon directly under the boiler, the siphon can be mounted anywhere in the condensate line. The siphon must be mounted inside the property. B Find a suitable position inside the property to mount the siphon, preferably close to the condensate pipe work. B Attach the L shaped mounting brackets to the top and bottom of the siphon. B Do not tighten the screws fully, allow the bracket to slide in their slots. B Position the siphon on the wall and mark on the wall where the brackets will be secured. B Drill suitable holes to accept the wall plugs and use the screws provided to secure the siphon to the wall. B Tighten the screws secure the brackets to the siphon B Cut the condensate pipe work and plumb the pipes to and from the siphon. B The elbow connectors can be swivelled through 180 to accommodate the pipe work connections, refer to figure. B The elbows can also be modified for straight connections, refer to the paragraph Modifying the elbow on page. B Ensure the foam insert () is fitted to the foam cover (). B Fit the foam cover over the siphon as shown in figure. Fig. Wall mounting [] Siphon mounting screw [] Condense Sure siphon body [] Foam insert [] Foam cover [] Siphon mounting screw 708010-0.1Wo Fig. Elbow swivelling range.1. SIPHON CONNECTIONS CONNECTION TO THE BOILER When mounting under the boiler, the rubber connector from the top elbow of the siphon may reach to the boiler discharge pipe, or a longer connector may be required and is provided if necessary. B If fitting to an existing boiler installation, disconnect the mm pipe from the boiler discharge pipe. 1. Remove the standard connector if the longer version is required.. Fit the rubber connect on to the siphon elbow.. Fit the rubber connect on to the boiler discharge pipe.. Secure the connection with the clip provided. Fig.. Boiler connection. 1. 708010-08.1Wo. 708010-0.Wo 70 80 10 (01/0)

MOUNTING THE SIPHON OTHER TYPES OF CONNECTION TO BOILERS When mounting under some boilers, a short piece of mm pipe may be required to make the connection from the siphon to the condensate discharge from the boiler. 708010-0.1Wo 1.. Fig. 7 General boiler connection CONDENSATE DISPOSAL CONNECTION B Connect the mm condensate disposal pipe to the bottom rubber connector on the siphon. B If fitting the siphon to an existing installation, shorten the mm condensate disposal pipe as required. Fig. 9. Elbow modification 708010-09.1Wo Fig. 8 Condensate disposal pipe work 708010-07.1Wo MODIFYING THE ELBOW The elbow can be modified to be a straight connector if the siphon is being installed away from the boiler. 1. Remove the rubber connector from the elbow.. Remove the elbow from the siphon and using a suitable hacksaw cut the elbow just above the small lugs. Cut the elbow as square as possible.. Fit the rubber connector over the modified elbow, ensuring that the connector engages with the two lugs. B Ensure that the connector gives a water tight seal. B Both elbows can be modified as straight connectors if the installation requires. Fig. 10 Straight connections 708010-10.1Wo 70 80 10 (01/0)

NOTES 70 80 10 (01/0) 7

WORCESTER, BOSCH GROUP: TECHNICAL SUPPORT: 08 89 APPOINTMENTS: 08 89 000 SPARES: 0190 771 LITERATURE: 08 89 9800 TRAINING: 0190 7 SALES: 0190 70 Worcester, Bosch Group Cotswold Way, Warndon, Worcester WR 9SW. Tel. 08 89 9900 Worcester, Bosch Group is a brand name of Bosch Thermotechnology Ltd. worcester-bosch.co.uk 70 80 10 (01/0)