Condensing, pre-mixed, wall-hung gas boilers with water tank

Similar documents
C Tahiti. condensing

C Nias Dual. Wall-hung boilers, forced draught, sealed chamber with storage tank. For indoor installation. Life-enhancing heat

FORMENTERA KC - KRB - KR

MINORCA KC - KR - KRB 24

C Elba Dual. Cast-iron, floor-standing boiler. High quality Italian product. Life-enhancing heat

Capri B Cast iron combination oil-fired boiler with water tank

C Bali R. Cast-iron boilers with atmospheric gas-fired burner. Life-enhancing heat

Capri R CH only, oil-fired, cast iron boiler

ANTEA KC - KR - KRB

1 VICTRIX ZEUS Superior kw I features

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

VICTRIX Superior kw Export VICTRIX Superior kw X Export

CITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready

Ciao Green Condensing Wall-Hung Boilers

TAHITI CONDENSING KR 55 - KR 85

TAHITI DUAL HC - HR INSTALLATION, USE AND MAINTENANCE. Italian product. High quality

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

Mynute Green k. Condensing Wall-Hung Boilers. Residential Heating

LIBRA DUAL INSTALLATION USE AND MAINTENANCE. Italian product. High quality IST 04 C

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

COND SYSTEM Condensation boiler outdoor / indoor combined with indoor heaters

SPECIFICATIONS - NIKE

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

Mynute Green Condensing Wall-Hung Boilers

Flue gas condensation...

VELA COMPACT INSTALLATION USE AND MAINTENANCE

ACCUMULATION OF EUROPEAN CLASS

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

General catalogue COMMERCIAL AND TECHNICAL INFORMATION. Commercial Range. March 2015 Edition

ENERGY TOP. Condensing boiler solutions

CITY OPEN - CITY BOX from 25 to 35 kw

ARIES DUAL MAINTENANCE MADE IN ITALY IST 04 C

PICTOR DUAL CTN 24/RTN 24 CTFS 24/RTFS 24 CTFS 28/RTFS 28 INSTALLATION USE AND MAINTENANCE IST 04 C

Ideasandformsinevolution

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

HORIZONTAL HOT WATER CYLINDER WHPF BO

Power X High Power Condensing Wall-Hung Boilers

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

S SOLAR RANGE

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

Exclusive Green E Condensing Wall-Hung Boilers

TRADITIONAL NIKE/EOLO STAR. Wall-hung combi boilers

IST 03 C ANTEA CONDENSING EN INSTALLATION, USE & MAINTENANCE MANUAL

Power X High Power Condensing Wall-Hung Boilers

DIDACTIC MANUAL FAMILY: GROUP: MODELS: VERSIONS: CODICE: AST 14C157/00. Wall-hung boilers

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

IST 03 C ELBA DUAL INSTALLATION, USE AND MAINTENANCE

24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus.

24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus

WHE 2.24 / WHE 2.24 FF

RinNOVA. User manual and installation instructions

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

The iqe Boiler Range. Combination and System T Boilers.

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E

Bluehelix Tech Wall-hung premix condensing boilers, only heating or instant combi operation

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

thea 35 MR/MN Kondens Wall-mounted condensing boiler

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

wall-mounted boilers, water heaters and pool heaters floor standing boilers, water heaters and pool heaters

WALL-HUNG HIGH EFFICIENCY GAS COMBINATION BOILERS. Efficient, economical and easy

2.1 BOILER ROOM BOILER ROOM DIMENSIONS 2.3 CONNECTING UP SYSTEM 2.4 CONNECTING UP FLUE 2.5 ELECTRICAL CONNECTION

WALL-HUNG SYSTEM & UNVENTED CYLINDERS

MICROGENUS HE WALL-HUNG HIGH EFFICIENCY GAS COMBINATION BOILER. minimum space HIGH EFFICIENCY

WALL-HUNG GAS CONDENSING BOILERS MCR-P 24/28 BIC. HOMOLOGATION B 23P - C 13x - C 33x - C 93x -C 53 - C 43x - C 83x *

USERS MANUAL FOR GAS BOILERS

IST 03 C CYLINDER WHPF BM USE AND MAINTENANCE HANDBOOK

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

AquaKond Split. Caring for the environment! New Condensation Boilers. Efficiency up to 109% 4 Stars. AquaKond 70 kw Standard I.S.P.E.S.L.

SGE Condensing Gas - Solar Water Heater

TECHNICAL INFORMATION MANUAL

MySMART Condensing Wall-Hung Boilers

ALKON 90 ALKON 90 MODEL 24,0 93,6 21,1 87, nominal heat output. conventional. max/min heat input. efficiency class (Directive 92/42)

EOLO MODULATING AND CONDENSING SUSPENDED GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION

4FLOOR-STANDING GAS CONDENSING BOILERS

Seradens Super Seradens Super Plus

white blue cobalt bordeaux light oak (rovere)

PICTOR CONDENSING KR 55 - KR 85

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

RINNOVA COND. User manual and installation instructions

Wall hung combination

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Fonte Lx NEW. Instantaneus Gas Water Heaters, conventional flue, low NOx. Residential Heating. compliant. Fonte Lx 14. Fonte Lx 11

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

CBX 24, 32 & 38 SBX 30

8FUEL OIL CONDENSING BOILERS

FORMENTERA CTN RTN CTFS RTFS

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

CODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80

Gas heaters and convectors ROBUR

Residential Heating Boilers

Rinnova Cond X. User manual and installation instructions

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual.

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL

Light commercial products. High output boilers Cascade systems

Transcription:

C 271-01 made in Italy Nias condensing Condensing, pre-mixed, wall-hung gas boilers with water tank Life-enhancing heat GB

Condensing, pre-mixed, wall-hung boilers with water tank Nias CONDENSING HIGH EFFICIENCY LOW EMISSIONS HIGH PRODUCTION OF DHW QUALITY STRENGTH RELIABILITY

life-enhancing heat E nvironmental concern and energy saving brought Fondital to design Nias Condensing Line Tech. It is a wall hung condensing boiler for heating and producing instant domestic hot water or with storage tank. Condensing technology allows for higher efficiency, not attainable in traditional technology boilers, reducing fuel costs and simultaneously decreasing polluting emissions. 92/42/CEE directive awards Nias Condensing Line Tech boilers with the highest efficiency rating, corresponding to the four stars and places them in the cleanest class of NOx pollutant emissions (EN 297, class 5). Using the exclusive AQUA PREMIUM SYSTEM guarantees a high production of domestic hot water despite a storage tank of only 25 litres and therefore with limited overall dimensions. The storage tank can also be disconnected.

Condensing, pre-mixed, wall-hung boilers with water tank Nias CONDENSING AIR INTAKE DUCT AIR INTAKE /FLUE GAS DISCHARGE HEAT EXCHANGER AIR/GAS MIXING DEVICE FAN CONDENSATE TRAP PUMP GAS VALVE HYDRAULIC ASSEMBLY PLATE EXCHANGER CONTROL PANEL SAFETY VALVE HoT WATeR outlet 50 c - 80 c FiRsT exchange BURNeR second exchange deflector FLUe gas outlet HoT WATeR collector WATeR inlet 30 c - 60 c PREMIXED BURNER HEAT EXCHANGER cold WATeR collector B ased on a stainless steel heat exchanger, with a large exchange surface and little water content, and a premixed burner, the boiler guarantees high performance thanks to flue gas heat recycling and small polluting emissions via continuous control of balanced operation in combustion sequence. Nias Condensing Line Tech is available in two different outputs 24.8 Kw and 27.4 Kw. The boiler exchanger is formed by a series of special stainless steel pipes, coil arranged and coupled in series and parallel configurations, in which the main circuit water is being conveyed. Hot flue gases go through the openings between the pipes relinquishing their heat to the water; the contact of already cooled flue gases with the first pipes in which cooled central heating return water flows, allows for condensing of water steam contained in them and therefore recovery of latent heat of vaporization. condensate drain

life-enhancing heat CONTROL PANEL SLIDING TEMPERATURE Outdoor probe (option) 1 2 3 4 5 The control panel guarantees simple use and management of the various boiler functions. The Aqua Premium system can be enabled or excluded by means of the domestic hot water selector switch (3). 1 LED thermometer for simple and immediate reading of CH water temperature. LEDs also display boiler malfunction via flashing indications allowing for problem diagnosis. 2 Function selector 3 DHW temperature adjusting + water tank activation selector 4 CH temperature adjusting selector 5 Manometer The Aqua Premium system can be activated/deactivated using the DHW selector Remote control (option) The boiler can be connected to a probe measuring outdoor temperature (option) allowing for sliding temperature soperation, with or without remote control. Boiler electronics automatically changes central heating flow temperature in relation to sensed outdoor temperature, selected thermoregulation curve, and desired room temperature, optimizing operation and achieving higher energy savings. N ias Condensing Line Tech boilers have several control and safety devices which guarantee safe, efficient and reliable operation. They are equipped with two air purging devices, one on the pump assembly and one on the heat exchanger, in order to provide the best and most effective air purge from the system. Furthermore, they are fit on the primary circuit with a flow meter ensuring correct water flow in the heat exchanger, with an automatic by-pass which can aid the heat exchanger, with a probe controlling the set temperature, and with a safety thermostat in order to avoid overheating. Flue gas temperature is controlled by two devices, a thermal breaker installed in the heat exchanger fumes circuit and a thermostat on the boiler output. Should a malfunction occur, the devices shut down the boiler operation ensuring safety. The probe on the domestic hot water circuit allows for an accurate control of the set domestic hot water temperature. Nias Condensing Line Tech boilers are equipped with a front door which can be opened from left to right and vice-versa for more convenient service procedure implementation. Nias condensing Line Tech adopts the AQUA PREMIUM system that allows large quantities of hot water to be used during periods of greater use but also allows for storage to be excluded when low quantity of hot water is required ensuring cost savings. AQUA PREMIUM SYSTEM boilers are more compact in size than the usual boilers with storage tanks. Central heating curves for operation with outdoor temperature probe 100 3.0 2.5 2.0 Temperatura Flow temperature di mandata 90 80 70 60 50 40 30 20 10 1.5 1.0 0.8 0.6 0.4 0.2 0 20 16 12 8 4 0-4 -8-12 -16-20 -24-28 -32-38 -40 Temperatura Outdor temperature esterna

Condensing, pre-mixed, wall-hung boilers with water tank Nias CONDENSING NIAS CONDENSING LINE TECH KB 24 - KB 28 Wall-hung, condensing, premixed boiler with water storage tank and sealed chamber. Available in two outputs: 24.8, and 27.4 kw (50 C - 30 C). Ready as standard to be fired with methane or propane gas. Can be connected to: - outdoor probe - remote control - electronic board managing a low temperature zone. AQUA PREMIUM SYSTEM associates to the secondary plate heat exchanger, a compact stratification water tank for large DHW withdrawals and is capable of supplying 16.3 l/min and 18.3 l/min respectively for the KB 24 and KB 28 models. The reduced dimensions of the stratification storage tank and the compact hydraulic group make the interior of the boiler efficient and easily accessible. KB model HYDRAULIC LAYOUT Primary heat exchanger Intercepting valve Flow meter Storage tank CH flow CH circulation pump Plate exchanger CH return DHW production in 10 minutes DHW circulation pump Temperature probe Utilities NIAS CONDENSING KB 24 163 litres/10 NIAS CONDENSING KB 28 183 litres/10 Dimensions 750 Accesories suplied with the boiler and included in the price Front panel door can be opened on both sides 450 Paper template bottom view top view Hydraulic kit

life-enhancing heat Head available for boiler (by-pass closed) Model KB 24 Model KB 28 Available head (mbar) Available head (mbar) Flow rate (l/h) Flow rate (l/h) ACCESSORIES Item Description Code Item Description Code Split pipe kit Ø 80+80 0KITSDOP00 Outdoor probe 0SONDAES01 Coaxial kit Ø 60/100, length 0.75 m 0CONDASP00 Electric zone kit with outdoor probe 0KITZONE00 Boiler cover 0COPERIG01 Coaxial connection kit Ø 60/100 0KITATCO00 Anti-frost kit 0KANTIGE00 90 elbow and flange kit Ø 60/100 0KCURFLA00 Fixing template (metal) 0DIMMECO03 Pipes and taps cover 0COPETUB02 Kit of flexible pipes (covered in stainless steel), N 2 x ¾ - N 3 x ½ L: 260/520 mm 0KITIDTR00 Remote control 0CREMOTO05 Gas and water tap kit 0KITRUBI01 INCLUDED IN THE PRICE: Standard hydraulic kit, paper template, air-intake sealing cap kit. Fondital company operates under UNI EN ISO 9001:2000 certified quality system management. Internal quality assessment of functionality, manufacturing processes, and final products ensure reliability and trouble-free operation. Quality System

The manufacturer reserves the right to implement modifications without notice. GENERAL FEATURES KB 24 KB 28 Gas category II2H3P II2H3P Nominal heat input kw 23.1 25.55 Nominal heat output (80-60 C) kw 22.7 25.4 Nominal heat output (50-30 C) kw 24.8 27.4 Minimum heat output (80-60 C) kw 6.5 5.4 Minimum heat output (50-30 C) kw 7.3 6.1 Useful efficiency at nominal heat input (80-60 C) % 97.5 97.53 Useful efficiency at minimum heat input (80-60 C) % 95.7 95.5 Useful efficiency at nominal heat input (50-30 C) % 104.8 105.4 Useful efficiency at minimum heat input (50-30 C) % 106.9 106.7 Useful efficiency at 30% % 109.1 108.9 Casing heat loss with burner on at nominal heat input % 1.4 0.9 Casing heat loss with burner on at minimum heat input % 2.1 2.3 Casing heat losses with burner off % 0.2 0.3 Chimney heat loss with burner on at nominal heat input % 2.6 2.5 Chimney heat loss with burner on at minimum heat input % 2.2 2.2 Energy efficiency mark (92/42 EEC) NOx class (EN 297/EN 483) 5 5 CH maximum working pressure bar 3 3 CH maximum working temperature C 83 83 CH temperature adjustment range C 20-78 20-78 Expansion vessel capacity l 10 10 CH consumption at nominal heat output (80-60 C) Methane m 3 /h 2.51 2.77 CH consumption at minimum heat output (80-60 C) Methane m 3 /h 0.69 0.57 CH consumption at nominal heat output (80-60 C) Propane kg/h 1.84 2.03 CH consumption at minimum heat output (80-60 C) Propane kg/h 0.52 0.49 Nominal heat output in DHW mode (ΔT 30 C) kw 28.0 31.0 Minimum heat output in DHW mode (ΔT 30 C) kw 7.3 6.1 Nominal heat input in DHW mode kw 27.2 30.4 Minimum heat input in DHW mode kw 6.8 5.7 Useful efficiency at nominal heat input in DHW mode (ΔT 30 C) % 103 102 DHW maximum pressure bar 8 8 DHW minimum pressure bar 0.5 0.5 Specific DHW flow rate ΔT 30 C l/min 16.3 18.3 DHW maximum working temperature C 62 62 DHW temperature adjustment range C 35-57 35-57 DHW consumption at nominal heat output Methane m 3 /h 2.96 3.28 DHW consumption at minimum heat output Methane m 3 /h 0.74 0.63 DHW consumption at nominal heat output Propane kg/h 2.26 2.50 DHW consumption at minimum heat output Propane kg/h 0.57 0.49 ΔT flue gas/air at nominal heat input C 67 51.2 ΔT flue gas/air at minimum heat input C 49 45 Flue gas flow rate at nominal heat input g/s 12.4 13.9 Flue gas flow rate at minimum heat input g/s 3.1 3.1 CO 2 at nominal heat input Methane % 9.0 9.0 CO 2 at nominal heat input Propane % 10.0 10.0 Residual available head at nominal heat input Pa 127 170 Residual available head at minimum heat input Pa 8 9 Supply pressure Methane mbar 20 20 Supply pressure Propane mbar 37 37 Number of nozzles 1 1 Nozzle diameter Methane mm 10.8 10.8 Nozzle diameter Propane mm 10.8 10.8 Power supply voltage/frequency V/Hz 230/50 230/50 Fuse on the power supply A 2 2 Absorbed electric power W 186 186 Electric protection rating IPX4D IPX4D Gas fitting G1/2 G1/2 Central heating fittings G3/4 G3/4 DHW fittings G1/2 G1/2 L x H x D mm 450x750x535 450x750x535 Net weight kg 68.4 71.5 Gross weight kg 78.8 81.8 Uff. Pub. Fondital - CTC 03 C 271-01 Ottobre 2010 (1.000-10/2010) 9PCGB03C271 FONDITAL S.p.A. 25079 VOBARNO (Brescia) Italy - Via Cerreto, 40 Tel. +39 0365 878.31 - Fax +39 0365 878.576 e mail: fondital@fondital.it - www.fondital.it