TEST REPORT Report No.: HN80013/2011 Page: 1 of 7 Date: August 30, 2011

Similar documents
TEST REPORT Reliability Laboratory Report No.: HCD0203/2008

TEST REPORT IEC60529 Edition TD990426C02

EN 60529:1991+A1:2000+A2:2013 Measurement and Test Report

TEMPORARY IMMERSION AND DUST TEST REPORT

TEMPORARY IMMERSION AND DUST TEST REPORT

TEST REPORT. Junction Box (Dimension 123x78mm) MakelModel No. Raychem /- Serial No. l?qdcg/1641 Quantity/ No. of samples

CERTIFICATE of QUALITY TEST

Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming)

DUST TEST REPORT. :Gold Apollo Co., Ltd. Company Model Name :A27. Date of Received :APR. 19, 2006 Date of Tested :APR. 19, 2006

Contact person Date Reference Page Henrik Andersson F (4) Electronics

Rules for Classification and Construction Additional Rules and Guidelines

ON THE BUTTON A reference guide to environmental ratings used for push button enclosures


Australian Standard. Degrees of protection provided by enclosures (IP Code) AS IEC Ed 2.1:2001 AS 60529

Test Report No. AJHG FB Date: FEB.17, 2015 Page 1 of 13

Survey of electrical equipment installed in hazardous areas on tankers

GLOBAL ENCLOSURE STANDARDS WITHIN THE ELECTRICAL INDUSTRY

IECEx Certificate of Conformity

Independent, accredited testing station Member laboratory of STL and LOVAG

38-SDMS-03 SPECIFICATIONS FOR LV DIGITAL PANEL METERS

Issued to: Videl S.r.l. Località Ponti di Pievescola Casole d Elsa (SI)

Report No 288/ Part 1 of 2 This report consists of 22 pages. Maxitone ZAMT Type A Addressable Sounder. See Assessment Summary for details

Table of Contents FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS...

PQS Independent type-testing protocol

HMN-D2 Insert Series

ENVIRONMENTAL TEST REPORT

Animals:Goats:Bleat.Calls,Warbling.Baa,Movements.Rubbing,Barn,Medium.Close,Interior,BG.Dog.Barks 01:21.618

FLASHLIGHT ANSI STANDARDS

ROAM DCM Control Specification Guideline Division 16520

FLASHLIGHT ANSI STANDARDS

Sound Pressure Level Test Report Report No. : PH2_09_ Date : 2009/6/30

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Information Sheet LIA IS 07 Issue 1 08/2013 Page 1 of 5 For LIA members use only

TEST REPORT IEC Safety of household and similar electrical appliances Part 2: Particular requirements for massage appliance

TEMPORARY SPECIFICATION FOR REFERENCE

PQS Independent type-testing protocol

JUL 18 Rev A1

Manufacturer since

/Mar/2014 Rev A

REVISION HISTORY Rev Description Author. Approved by Date A Initial release per ECO Dean King Dean King November 16, 2012

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

Environment Test Report

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

IR25 Dual Gas Series Datasheet

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Certificate of Compliance

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

TTM-01: ebm-papst fans for outdoor applications water and humidity protection

The product and any acceptable variation thereto is specified in the Annex to this certificate and the documents therein referred to.

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

IECEx Certificate of Conform ity

Control Panel Basics Volume 1

GUANGDONG XINYU TECHNOLOGY INDUSTRIAL CO., LTD

1 Intended Use of the Breas HA 01 Humidifier

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

PAKISTAN STANDARD LED MODULES FOR GENERAL LIGHTING (SAFETY SPECIFICATIONS) PS: _5211/2017 ICS:

Test Methods for Consideration Into Radio Standard

IECEx Certificate of Conformity

IECEx Certificate of Conformity

XUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12

IR15 Dual Gas Series Datasheet

Type approval qualification of Photovoltaic Modules Procedures and test experiences

HEATFAST HF9101-V1 AMBIENT SENSING TRACE HEATING THERMOSTAT

STANDARDS UPDATE NOTICE (SUN) ISSUED: August 23, 2017

INTERNATIONAL STANDARD NORME INTERNATIONALE

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

IECEx Certificate of Conformity

Schneider Electric ibusway for Data Center: Schneider Electric Powerbus Plug-In Busway

Frost Protection Thermostat

Gas cylinder scale Model GCS-1

IECEx Certificate of Conformity

DRAFT. Models: LED-8085M30, LED-8085M30C; LED-8085M42, LED-8085M42C; LED-8085M57, LED-8085M57C

CNBOP-PIB Standard Fire Protection

Connecta System THE FIRE PERFORMANCE TUNNEL LIGHTING AND POWER SYSTEM

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

This is a preview - click here to buy the full publication INTERNATIONAL ELECTROTECHNICAL COMMISSION

Safety Certification of Solid-State Lighting Products. September 23, 2009 Todd Straka Director - Lighting Services

Certificate of Compliance

VD 53 - Vacuum drying oven for non-flammable solvents

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

Lawnmowers (pedestrian controlled, battery powered)

Options for Diesel Fire Pump Controllers

Certificate of Compliance

Installer manual ELK 213 Immersion heater

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

(PT-A1-AC ) Surface Mount Ambient Visible Light Sensor. Electronics Tech. Direct Electronics Industry Co., Ltd. Version: July 31, 2017

Refrigerated Incubator Model and Operating Instructions

38-SDMS-01 SPECIFICATIONS FOR FAULT INDICATORS FOR UNDERGROUND DISTRIBUTION NETWORKS

Recirculating Chiller RC350G-RC400G RC1400G-RC3000G. Operating Manual

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

SOUND RECEPTION SYSTEM

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

Umbrellas, Lighting & Weather Accessories

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

Luminaires Part 2-4: Particular requirements Portable general purpose luminaires

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

UL TEST REPORT AND PROCEDURE

Table of Content LT 5165-UL

Transcription:

Page: 1 of 7 Date: August 30, 2011 GLACIALTECH INC. 9FL, NO. 352, SEC. 2, JUNG SHAN RD., JUNG HE CITY, TAIPEI, TAIWAN The following merchandise was submitted and identified by the vendor as: Product Description: LED Driver Style/ Item No.: Quantity: Total 1 piece Testing Period: Aug. 23, 2011 to Aug. 26, 2011 We have tested the submitted sample(s) as requested and the following results were obtained: Test Required: Test for Degrees of Protection Provided by Enclosures IP Code IP67 First characteristic numeral Degrees of protection against access to hazardous parts and against solid foreign objects Second characteristic numeral Degrees of protection against ingress of water Test Results: Conclusion Submittals sample(s) comply with the requirement and acceptance conditions of IEC 60529 Edition 2.1: 2001-02 Degrees of Protection Provided by Enclosures -- IP67 The detailed description of test result, please see attached sheet(s). Signed for and on behalf of SGS TAIWAN Ltd. Terence Hsieh Department Manager

Page: 2 of 7 Test for Degrees of Protection Provided by Enclosures: Test Equipment: Name Brand Model Serial No. 1.0 mm Test Wire Probe ED&D TRP-02 B0050180 Digital Force Gauge ALGOL HF-50 HF-106764 Dust Tester T-MACHINE TMJ-9723C T-23-050411 IPX7/IPX8 Immersion Tank Self-made SGS-ETR-0201 000001 Programmable DC Electronic Load Chroma 63006 630060001756 Lab Environmental Conditions: Ambient temperature: 25±3 Relative humidity: Test Method/ Specification: 55±20%RH According to IEC 60529 Edition 2.1: 2001-02--IP67 1. Test for protection against access to hazardous parts: IEC 60529 Edition 2.1: 2001-02--IP6X The test wire with 1.0 mm in diameter and 100 mm long is pushed against or inserted through any openings of the enclosure with the force specified in Table 6 in IEC 60529 Edition 2.1: 2001-02. Examine whether the test wire touches the hazardous live parts inside the enclosure or not. Test force: 1 N±10 % 2. Test for protection against solid foreign objects: Type of dust: The amount of dust: IEC 60529 Edition 2.1: 2001-02--IP6X (Dust test) Talcum powder 2 kg The chamber size: 1 m 3 The maximum depression: -20 mbar Test duration: 8 hours Examine the protection against ingress of dust of specimen(s) and perform functional check after this test. Functional check: Connect the specimen with rated power 110V AC then examine whether the DC voltage output function of specimen could be work normally or not.

Page: 3 of 7 Test Method/ Specification--Continued: 3. Test for protection against water: Test means: According to IEC 60529 Edition 2.1: 2001-02--IPX7 Completely immerse the specimen in water in its service position as Test condition: See below items marked, The lowest point of enclosures with a height less than 850 mm is located 1000 mm below the surface of the water The highest point of enclosures with a height equal to or greater than 850 mm is located 150 mm below the surface of the water Test duration: 30 minutes Test device: As shown in photo 7, 8 Examine the protection against ingress water of specimen(s) and perform functional check after this test. Functional check: Connect the specimen with rated power 110V AC then examine whether the DC voltage output function of specimen could be work normally or not.

Page: 4 of 7 Specimen: Style/ Item No.: Quantity: Total 1 piece Test Result: A. Degrees of protection against access to hazardous parts and against solid foreign objects (IP6X) A-1 Test for protection against access to hazardous parts (IP6X) Check Item Test Result Style/ Item No. 1 Does the test wire penetrate any openings of the enclosure? No 2 (followed check item 1) If the test wire penetrates any openings of the enclosure, does the test wire touch any hazardous live parts or any hazardous mechanical parts? 3 (followed check item 2) Does adequate clearance be kept between the test wire and hazardous live parts or hazardous mechanical parts? Note 1: means Not Applicable. Note 2: The check items in this test report for inspecting the degree of protection provided by enclosures are reference to the requirements specified in IEC 60529 Edition 2.1: 2001-02 and in accordance with the acceptance conditions A-2 Test for protection against solid foreign objects (IP6X) Test Result Check Item Style/ Item No. 1 Does any dust deposit inside the enclosure? No 2 Functional Check Normal Note 1: means Not Applicable. Note 2: The check items in this test report for inspecting the degree of protection provided by enclosures are reference to the requirements specified in IEC 60529 Edition 2.1: 2001-02 and in accordance with the acceptance conditions

Page: 5 of 7 Test Result--Continued: B. Degree of protection against ingress of water (IPX7) Test Result Check Item Style/ Item No. 1 Does any water enter the enclosure? No 2 2.1 2.2 2.3 (followed check item 1) If any water has entered, does the water accumulate near the cable end or live parts? (followed check item 2) Does the water be sufficient to interfere with the correct operation of the equipment or impair safety? (followed check item 2.1) Does the water deposit on insulation parts where it could lead to tracking along the creepage distances? (followed check item 2.2) Does the water reach live parts or windings not designed to operate when wet? 3 Functional Check Normal Note 1: means Not Applicable. Note 2: The check items in this test report for inspecting the degree of protection provided by enclosures are reference to the requirements specified in IEC 60529 Edition 2.1: 2001-02 and in accordance with the acceptance conditions

Page: 6 of 7 Test Photos: 1. Appearance of specimen: GP-HS15P-24VZZZ 2. Functional Check 3. Test for protection against access to hazardous parts 4. Test for protection against access to hazardous parts 5. Test for protection against solid foreign objects (Dust test) 6. Test for protection against solid foreign objects (Dust test)

Page: 7 of 7 Test Photos--Continued: 7. Test for protection against water 8. Test for protection against water The End of Test Report