HYUNDAI HEAVY INDUSTRIES CO., LTD.

Similar documents
TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

is found to comply with DNV GL rules for classification Ships, offshore units, and high speed and light craft

TYPE APPROVAL CERTIFICATE

EU RO MUTUAL RECOGNITION TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

Low-voltage switchgear and controlgear - rated voltage does not exceed 1000V AC or 1500V DC

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

DNVGL-CP-0398 Edition December 2015

Issued to DISTRIBUIDORA INTERNACIONAL CARMEN, S.A -DICSA- Zaragoza Zaragoza, Spain

TYPE APPROVAL CERTIFICATE

DNVGL-CP-0407 Edition February 2016

For compliance with Resolution MEPC.174(58), the Certificate is issued on behalf of the Norwegian Maritime Authority.

DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

DNVGL-CP-0401 Edition February 2016

DNVGL-CP-0399 Edition March 2016

Shipboard incinerators with capacities up to 4000 kw

For compliance with Resolution MEPC.174(58), the Certificate is issued on behalf of the Norwegian Maritime Authority.

Indicators for Rudder Angle, Rate of Turn, Propeller Shaft Revolution and Propeller Pitch

Notified Body No.: 0098

DNVGL-CP-0402 Edition February 2016

Notified Body No.: 0575 G U A D N L. SJq

EC-TYPE EXAMINATION CERTIFICATE (MODULE B)

SOUND RECEPTION SYSTEM

Notified Body No.: 0575

SIMPLIFIED VOYAGE DATA RECORDER (S-VDR)

Notified Body No.: 0575

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Confirmation of Product Type Approval

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

For compliance with Resolution MEPC.174(58), the Certificate is issued on behalf of the Norwegian Maritime Authority.

TYPE APPROVAL CERTIFICATE

For the compliance with the resolution MEPC.174(58), the Certificate is issued on behalf of the Norwegian Maritime Authority.

RADAR REFLECTOR STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

Circuit Breakers JANUARY The electronic pdf version of this document found through is the officially binding version

MARINE GYRO COMPASS STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

Terminal lugs for LV power cables with aluminum conductors

TYPE APPROVAL CERTIFICATE

Glass fibre rovings - Non-metallic materials

AUGUST 2016 CONTENTS:

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Procedure for the Approval of New Fire Detection and Alarm Technologies

ZERTI ~CERTIFICAJE. Certificate holder. Product tested. Manufacturer. Type designation. Codes and standards forming the basis of testing

GROUNDING AVOIDANCE SYSTEM (GAS)

SCOPE OF ACCREDITATION

Coatings for protection of FRP structures with heavy rain erosion loads

DOO IK ENG PRODUCT CATALOG DOO IK ENG TEMPERATURE SENSOR PRESSURE SWITCH NON FLOW SWITCH THERMOMETER

Automation, Software und Informationstechnologie

Spark Extinguishing Systems

Annubar Flowmeter Series

WÄRTS1LÄ. EC-Declaration of Conformitv. In accordance with the Marine Equipment Directive 2014/90/EU

Rules for Classification and Construction Additional Rules and Guidelines

INTERNATIONAL STANDARD

EC TYPE EXAMINATION (MODULE B) CERTIFICATE (EC-US MRA)

Audible warning devices for external alarm

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Technical Report No. CPSA Rev. 00 Dated Test according to the test specification Evaluation and categorization

EC-TYPE EXAMINATION CERTIFICATE (MODULE B)

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Declaration of conformity maintenance record. No Revised date Contents Reasons Approval

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

INTERNATIONAL STANDARD

Report reference No...: 10TH0052_AS4777_+_ISR_3 Tested by (printed name and signature)...: Urs Seifert. Approved by (printed name and signature)...

EU Declaration of Conformity EMC Directive 2014/30/EU, ATEX Directive 2014/34/EU, PED Directive 2014/68/EU No: MMI SE

MED 96/98/EC QUALITY SYSTEM MODULE D CERTIFICATE

To Whom it May Concern;

EC TYPE EXAMINATION (MODULE B) CERTIFICATE

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Test Report Garvan Enterprises Limited

OMRON SCIENTIFIC TECHNOLOGIES INCORPORATED ECDeclaration ofconformity

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Rosemount 4500 Hygienic Pressure Transmitter. Start

GUIDE TO APPROVAL OF RETROFIT BALLAST WATER MANAGEMENT SYSTEM INSTALLATIONS

EN50438 TEST REPORT SUMMARY. Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SmartPower Solutions. SmartPower Solutions. Product Data Sheet , Rev AC January Contents

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

EU DECLARATION OF CONFORMITY. 3. This declaration of conformity is issued under the sole responsibility of the manufacturer.

APRIL 2010 ELECTRICAL EQUIPMENT STANDARD FOR CERTIFICATION DET NORSKE VERITAS. No. 2.9 Type Approval Programme No

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Valve Manufacturers Association of America

INTERNATIONAL STANDARD

Conformity assessment procedures for the Alarm Components Scheme

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD

Lloyd s Register Type Approval System Test Specification Number 3

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

Test Report. Appliance EMF Testing

Transcription:

Certificate No.: 52700-2009-AE-KOR-RvA Initial Certification Date: 07 March, 1997 Valid: 16 March, 2015 16 March, 2018 This is to certify that the management system of CO., LTD. 1000, Bangeojinsunhwando-ro, Dong-gu, Ulsan, Korea and the sites as mentioned in the Appendix accompanying this Certificate has been found to conform to environmental management system standard(s): ISO 14001:2004, KS I ISO 14001:2009 This certificate is valid for the following Scope: Design, Research & Development, Manufacture and Construction of Various Products of Shipbuilding, Offshore & Engineering, Industrial Plant & Engineering, Engine & Machinery, Electro Electric Systems, Green Energy, Construction Equipment including Administration & Assistance and Construction Management. Place and date: Seoul 06 March, 2015 For the issuing office: DNV GL - Business Assurance 18th Floor, Kyobo Building, 1, Jongro, Jongno-gu, Seoul, Republic of Korea. Tel. : +82 2 723 7593 In Kyoon Ahn Management Representative Lack of fulfilment of conditions as set out in the Certification Agreement may render this Certificate invalid. ACCREDITED UNIT: DNV GL Business Assurance B.V., Zwolseweg 1, 2994 LB Barendrecht, The Netherlands. Tel.: +31 10 2922 689. www.dnvgl.com

Certificate No.: 52700-2009-AE-KOR-RvA Place and date: Seoul 06 March, 2015 Appendix I to Certificate CO., LTD. Locations included in the certification are as follows: Site Name Site Address Site Scope CO., LTD. H/Q CO., LTD. Offshore & Engineering yard 1000, Bangeojinsunhwando-ro, Donggu, Ulsan, Korea 400, Bangeojinsunhwando-ro, Dong-gu, Ulsan, Korea Design, Research & Development, Manufacture and Construction of Various Products of Shipbuilding, Offshore & Engineering, Industrial Plant & Engineering, Engine & Machinery, Electro Electric Systems, Green Energy, Construction Equipment including Administration & Assistance and Construction Management. Design & Development, Manufacture and Construction of Offshore & Engineering. CO., LTD. Seonam Factory 223, Sapyeong-ro, Nam-gu, Ulsan, Korea Manufacture of Electro Electric Systems. CO., LTD. Yongyeon Yard 800, Cheoyong-ro, Nam-gu, Ulsan, Korea Design & Development, Manufacture of Various Products of Shipbuilding. CO., LTD. Onsan Yard 72, Yeonja-ro, Onsan-eup, Ulju-gun, Ulsan, Korea Manufacture of Offshore & Engineering. CO., LTD. Pipe Fabrication Shop 50, Yeongji-ro, Oedong-eup, Gyeongjusi, Gyeongsangbuk-do, Korea Manufacture of Offshore & Engineering. CO., LTD. Pipe Painting Shop 293-15, Naeoe-ro, Oedong-eup, Gyeongju-si, Gyeongsangbuk-do, Korea Manufacture of Offshore & Engineering Lack of fulfilment of conditions as set out in the Certification Agreement may render this Certificate invalid. ACCREDITED UNIT: DNV GL Business Assurance B.V., Zwolseweg 1, 2994 LB Barendrecht, The Netherlands. Tel.: +31 10 2922 689. www.dnvgl.com Page 1 of 2

Certificate No.: 52700-2009-AE-KOR-RvA Place and date: Seoul 06 March, 2015 CO., LTD. Gunsan Yard 625, Seohae-ro, Gunsan-si, Jeollabukdo, Korea Design & Development, Manufacture and Construction of Various Products of Shipbuilding. CO., LTD. Gunsan Rotating Machinery Factory and Wind Turbine Factory 232, Dongjangsan-ro, Gunsan-si, Jeollabuk-do, Korea Design & Development, Manufacture and Construction of Rotating Machinery Factory and Wind Turbine. CO., LTD. Solar Energy Factory 313, Soi-ro, Soi-myeon, Eumseong-gun, Chungcheongbuk-do, Korea Design & Development, Manufacture of Solar energy product. Lack of fulfilment of conditions as set out in the Certification Agreement may render this Certificate invalid. ACCREDITED UNIT: DNV GL Business Assurance B.V., Zwolseweg 1, 2994 LB Barendrecht, The Netherlands. Tel.: +31 10 2922 689. www.dnvgl.com Page 2 of 2

TYPE APPROVAL CERTIFICATE Certificate No: TAE00001ET Revision No: 1 This is to certify: That the Frequency Converter with type designation(s) N800A Issued to Hyundai Electric & Energy Systems Co., Ltd. ULSAN, Republic of Korea is found to comply with DNV GL rules for classification Ships and offshore units Application : Frequency Converter for Asyncronous Motors Range: 0,55 kw to 800 kw 208-240 / 380-480 (500) / 525-690 VAC supply. Product(s) approved by this certificate is/are accepted for installation on all vessels classed by DNV GL. This Certificate is valid until 2021-10-17. Issued at Busan on 2017-05-26 DNV GL local station: Ulsan for DNV GL Approval Engineer: Baeg Soon Choi Michael Jost Auf der Stroth Head of Section This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid. The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed. Form code: TA 1411a Revision: 2015-05 www.dnvgl.com Page 1 of 4 DNV GL 2014. DNV GL and the Horizon Graphic are trademarks of DNV GL AS.

Job Id: 262.1-023641-3 Certificate No: TAE00001ET Revision No: 1 Product description N800A Frequency converter for use in various marine applications. Main voltage 208-240V, 50/60Hz, 3Ph Frequency Current rating Frame size Enclosure Converter type 45 degc continuous current I Lout (A) Protection** 0100-3L-0003-2+BM2Y+xxxx 3,15 MR4 IP21, IP54 0100-3L-0007-2+BM2Y+xxxx 5,7 MR4 IP21, IP54 0100-3L-0011-2+BM2Y+xxxx 9,5 MR4 IP21, IP54 0100-3L-0012-2+BM2Y+xxxx 11,05 MR4 IP21, IP54 0100-3L-0024-2+BM2Y+xxxx 21 MR5 IP21, IP54 0100-3L-0031-2+BM2Y+xxxx 28 MR5 IP21, IP54 0100-3L-0048-2+BM2Y+xxxx 39,5 MR6 IP21, IP54 0100-3L-0062-2+BM2Y+xxxx 55 MR6 IP21, IP54 0100-3L-0075-2+BM2Y+xxxx 68,5 MR7 IP21, IP54 0100-3L-0088-2+BM2Y+xxxx 81,5 MR7 IP21, IP54 0100-3L-0105-2+BM2Y+xxxx 96,5 MR7 IP21, IP54 0100-3L-0140-2+BM2Y+xxxx 127 MR8 IP00, IP21, IP54 0100-3L-0170-2+BM2Y+xxxx 155 MR8 IP00, IP21, IP54 0100-3L-0205-2+BM2Y+xxxx 187,5 MR8 IP00, IP21, IP54 0100-3L-0261-2+BM2Y+xxxx 236 MR9 IP00, IP21, IP54 0100-3L-0310-2+BM2Y+xxxx 280,5 MR9 IP00, IP21, IP54 Frequency Converter type Main voltage 380-480V (500V), 50/60Hz, 3Ph Current rating 45degC continuous current ILout (A) Frame size Enclosure Protection** 0100-3L-0003-5+BM2Y+xxxx 3 MR4 IP21, IP54 0100-3L-0005-5+BM2Y+xxxx 4,95 MR4 IP21, IP54 0100-3L-0008-5+BM2Y+xxxx 6,8 MR4 IP21, IP54 0100-3L-0012-5+BM2Y+xxxx 10,8 MR4 IP21, IP54 0100-3L-0016-5+BM2Y+xxxx 14 MR5 IP21, IP54 0100-3L-0023-5+BM2Y+xxxx 19,5 MR5 IP21, IP54 0100-3L-0031-5+BM2Y+xxxx 27 MR5 IP21, IP54 0100-3L-0038-5+BM2Y+xxxx 34,5 MR6 IP21, IP54 0100-3L-0046-5+BM2Y+xxxx 42 MR6 IP21, IP54 0100-3L-0061-5+BM2Y+xxxx 53,5 MR6 IP21, IP54 0100-3L-0072-5+BM2Y+xxxx 66,5 MR7 IP21, IP54 0100-3L-0087-5+BM2Y+xxxx 79,5 MR7 IP21, IP54 0100-3L-0105-5+BM2Y+xxxx 96 MR7 IP21, IP54 0100-3L-0140-5+BM2Y+xxxx 122,5 MR8 IP00, IP21,IP54 0100-3L-0170-5+BM2Y+xxxx 155 MR8 IP00, IP21,IP54 0100-3L-0205-5+BM2Y+xxxx 187,5 MR8 IP00, IP21,IP54 0100-3L-0261-5+BM2Y+xxxx 233 MR9 IP00, IP21,IP54 0100-3L-0310-5+BM2Y+xxxx 280,5 MR9 IP00, IP21,IP54 0100-3L-0385-5+BM2Y+xxxx 347,5 MR10 IP00 0100-3L-0460-5+BM2Y+xxxx 422,5 MR10 IP00 0100-3L-0590-5+BM2Y+xxxx 555 MR10 IP00 Application/Limitation Form code: TA 1411a Revision: 2015-05 www.dnvgl.com Page 2 of 4

Job Id: 262.1-023641-3 Certificate No: TAE00001ET Revision No: 1 Supply voltage range: 200-240 V / 380-480 (500) V / 525-690 V, 50/60 Hz Voltage variation: ± 10 % Frequency variation: 47-65 Hz Output frequency: 8-320 Hz Temperature range in operation: 0-40 C (40 55 C when derated 2,5%/ C) Temperature class: A Vibration class: A Humidity class: A EMC class*: DNV Standard No 2.4 / IEC 61800-3 C2 To be used on EMC class A locations Documents for the actual application are to be submitted for approval in each case in accordance with DNVGL-RU-SHIP Pt.4 Ch.8 Sec.1 Table2. A Product Certificate is required for converters 100 kw. * Converters EMC classed C2 according to IEC 61800-3 can be installed in "special distribution zone" and "general power distribution zone" in accordance with IEC 60533 provided precautions are taken to attenuate these effects on the distribution system, so the safe operation is assured. ** To be installed in an enclosure with an IP degree in accordance with DNV GL Rules w.r.t. location. The Type Approval covers hardware and software for the basic controller. Clause for software control: All changes in software are to be recorded as long as the system is in use on board. The records of all changes are to be forwarded to DNV GL for evaluation and approval. Major changes in the software are to be approved before being installed in the converter. Type Approval documentation Technical information VACON 100 AC DRIVES SIMPLY SUPERIOR Brochure from Vacon, Vacon 100 series voltage and currect ratings, XL sheet from Vacon. Test reports SGS Fimko test reports 276122-2 & 3 issued 20153-01-19, 276122-4 issued 2015-02-16, 276122-2, 3 &4 Amendment no 1 issued 2015-07-06. 278414-1, 2 &3 issued 2015-03-12, 278414-4 & 5 issued 2015-03-13 and 265797-1 issued 2012-01-20. SGS Test Reports no. 26977-1 & 2 issued2013-01-02. VTT Test Report no VTT-S-01016-15 issued 2015-03-25 & VTT-S-02593-15 issued 2015-06-17. Vacon Research Reports no. TED10720 to TED10724 issued 2015-07-03 & TED10757 issued 2015-07-17. TÛV Technical Report No. 71395257, dated 2011-10-12. Type Approval Initial Assessment Report dated 2016-08-24. Tests carried out Visual inspection, Performance, Power supply failure, Power supply variations, Voltage/frequency variation, Vibration/shock, Dry heat, Damp heat, Insulation resistance, High voltage. EMC: Electrical fast transient (Burst), electrical slow transient (Surge), RF-common mode Voltage, radiated RF-electromagnetic fields, electric discharge (ESD), radiated and conducted emission. Marking of product N800A - Type designation Power Voltage Form code: TA 1411a Revision: 2015-05 www.dnvgl.com Page 3 of 4

Job Id: 262.1-023641-3 Certificate No: TAE00001ET Revision No: 1 Periodical assessment The scope of the periodical assessment is to verify that the conditions stipulated for the Type Approval is complied with and that no alterations are made to the product design or choice of materials. The main elements of the assessment are: Inspection on factory samples, selected at random from the production line (where practicable) Results from Production Sample Tests (PST) and Routines (RT) checked (if not available tests according to PST and RT to be carried out) Review of type approval documentation Review of possible change in design, materials and performance Ensuring traceability between manufacturer s product type marking and Type Approval Certificate. Assessment to be performed at least every second year. END OF CERTIFICATE Form code: TA 1411a Revision: 2015-05 www.dnvgl.com Page 4 of 4

Powered by TCPDF (www.tcpdf.org) EC Type-Examination Certificate Reg.-No.: 01/205/5494.01/17 Product tested Safety Function "Safe Torque Off (STO)" within Adjustable Frequency AC Drives Certificate holder Hyundai Electric & Energy Systems Co., Ltd. 75, Yulgok-ro, Jongno-gu Seoul Republic of Korea Type designation N800A AC Drives with OPT-BJ-V (STO and ATEX option board): Frame Sizes MR4 to MR12, N800A0100-3L-xxxx-y, Details see Revision List Codes and standards EN 61800-5-2:2007 EN 61800-5-1:2007 EN 61800-3:2004 + A1:2012 EN ISO 13849-1:2008 + AC:2009 EN 62061:2005 + AC:2010 + A1:2013 IEC 61508 Parts 1-7:2010 EN 60204-1:2006 + A1:2009 + AC:2010 (in extracts) 10/222 12. 12 E A4 TÜV, TUEV and TUV are registered trademarks. Utilisation and application requires prior approval. Intended application Specific requirements The safety function "Safe Torque Off" complies with the requirements of the relevant standards (PL e / Cat. 3 acc. to EN ISO 13849-1, SIL CL 3 acc. to EN 61800-5-2 / EN 62061 / IEC 61508) and can be used in applications up to PL e and SIL 3. The instructions of the associated Installation and Operating Manual shall be considered. It is confirmed that the product under test complies with the requirements for machines defined in Annex I of the EC Directive 2006/42/EC. Valid until 2020-09-22 The issue of this certificate is based upon an examination, whose results are documented in Report No. 968/FSP 1230.01/17 dated 2017-07-14. This certificate is valid only for products which are identical with the product tested. It becomes invalid at any change of the codes and standards forming the basis of testing for the intended application. Berlin, 2017-07-14 www.fs-products.com Notified Body for Machinery, NB 0035 Dipl.-Ing. Eberhard Frejno TÜV Rheinland Industrie Service GmbH, Alboinstr. 56, 12103 Berlin / Germany Tel.: +49 30 7562-1557, Fax: +49 30 7562-1370, E-Mail: industrie-service@de.tuv.com