C5 4 SERIES INSULATION ARMOUR PLUS HOT FOOD HOLDING CABINETS

Similar documents
C5 4 SERIES INSULATION ARMOUR PLUS HOT OR COLD FOOD TRANSPORT CABINETS

8 Series Controlled Temperature Heated Holding Cabinets

8 Series Controlled Temperature Heated Holding Cabinets

9 Series Controlled Humidity Heated Holding & Proofing Cabinets

T-SERIES HOT FOOD HOLDING CABINETS INSTRUCTIONS FOR USE

TC90S TC90B. TC90 Series. InterMetro Industries Corporation Wilkes-Barre, PA

3 Series 1 Series Heated Cabinets

3 Series 1 Series Heated Cabinets

Metro Heated Banquet Cabinets

Metro Heated Banquet Cabinets

C175 Series USER MANUAL FOR THE METRO C175 SERIES UNINSULATED HEATED CABINET. Recommended Food Holding Guidelines Listed on page 7. Rev.

OPERATING and MAINTENANCE INSTRUCTIONS Models: H138NPSCLCMCQRL Merchandising Hot Cabinets

CC-2222C-PL, CC-2222C-PRL, CC-2222C-PR-2, CC-2222C-PL-2,

OPERATING and MAINTENANCE INSTRUCTIONS Models: H138NPS36CLCMQRL i7 Hot Cabinet

OPERATING and MAINTENANCE INSTRUCTIONS Taco Bell Hot Cabinet Full Size Model: H137S27D1TB & H137S27D1LTB Half Size Model: H137S273D1TB & H137S273D1LTB

OPERATING and MAINTENANCE INSTRUCTIONS Taco Bell Hot Cabinet Full Size Model: H137S27D1TB & H137S27D1LTB Half Size Model: H137S273D1TB & H137S273D1LTB

MANUAL FOOD HOLDING & TRANSPORT CABINETS WITTCO MODEL NUMBERS

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

Operator s Manual CAYENNE HEAT N SERVE 4/3 RECTANGULAR RETHERMALIZER ENGLISH

OPERATIONS MAINTENANCE MANUAL

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor RADIANT OVENS

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

Instruction Manual. Nacho Cheese Dispenser and Warmer

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor AQUATEMP TM HUMIDITY CONVECTION and RETHERM OVENS with MICROPROCESSOR CONTROLS

Flood Pumper Plus. Water Transfer Machine. Operator and Parts Manual. Model No.: Rev. 00 (11-99)

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 8kW QUIKTHERM RETHERM OVENS

Refrigerators. Technical Manual and Replacement Parts List FORM NO REV H MODEL SKTTR7FW MODEL SKC1220W

REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 12kW QUIKTHERM RETHERM OVENS

Instruction Manual. Portion Cup Cheese Warmer

Instruction Manual. Dogeroo, Super Dogeroo, and Mini Dogeroo

HD-26, HD-36, HD-48 Heated Displays

User Manual. Commercial School Milk Cooler User s Manual. Commercial School Milk Coolers: MC34, MC49, MC58

HOT FOOD HUMIDITY CABINET MODEL HFD-3

Wax Base Heater & Dispenser

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

OPERATING and MAINTENANCE INSTRUCTIONS Models: H137WSUA...D & H138WS18...D Series Humidity Holding Hot Cabinet

Operation Manual For Sodir. ½ Size Convection Oven FC-60, FC-60G

G-10f/GCG-10f UPRIGHT COOLER

OPERATIONS FOOD HOLDING & TRANSPORT CABINETS. wîttco foodservice. equipment

WARMING AND MERCHANDISING CABINET

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER

DryAire DRYING CABINET

SBF Series ELECTRIC CONNECTIONLESS STEAMER INSTALLATION - OPERATION - MAINTENANCE

Viking Installation Guide

REF5-BB Undercounter Blood Bank Refrigerator

OPERATING INSTRUCTIONS

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

Technical Manual and Replacement Parts List. Mobile Freezer

OPERATING and MAINTENANCE INSTRUCTIONS Models: H138NPSCMQ Series Hot Cabinet and H138NPSCMQ-15A Series Hot Cabinet

AHPO-6/18 GOLD PROOFER OVEN

MODEL 925W FEATURES: ELECTRICAL DATA: DIMENSIONS: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET

MERCHANT POPCORN MACHINE SERVICE MANUAL

WARNING RISK OF FIRE OR ELECTRIC SHOCK DO NOT OPEN

RCM-77. Instruction Manual. G-Series Cooler. U.S. Patent No. 8,215,125 RECHARGE COLD MERCHANDISER

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor Undercounter AquaTemp HUMIDITY OVENS and CONVECTION OVENS 2000 WATTS

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405

Mobile Hot Food Merchandiser Series. Series: MHB Operation Manual

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor QUIKTHERM RETHERM ROLL-IN OVENS WITH RACK 18,000, 12,000 or 8,000 WATTS

OPERATING INSTRUCTIONS

SERIES NAV S Display Merchandisers

INSTALLATION & OPERATION MANUAL

SAFETY PRECAUTIONS. 2) Before operating machine: - Make sure all safety devices are in place and operate properly.

OWNER S MANUAL MODEL BW4B SLICER WARMER

Technical Manual and Replacement Parts List. f Real Freezers

Ui REFRIGERATOR SPEC SHEET

InstructIon Manual KrEs EQuIPMEnt stands

WARMING AND MERCHANDISING CABINET

Carter-Hoffmann Equipment Manual Models RTB201, RTB202 & RTB282 RTB Series Roll-in Holding Cabinets

Installation & Operations Manual for. BMG-HGP Model Bottom Mounted Full-Length Swing Glass Door Refrigerator Merchandisers. 4/17 Rev.

Hot Dog Hutch. Models HDH-3, HDH-3DR, & HDH-4 owner s manual. Manufacturing Numbers:

Installation Manual UNIVERSAL C-750 PRE-MIX DISPENSER

Up to 60 Pint Commercial Grade DEHUMIDIFIER

690 and Power Fishing Systems

User Instruction Manual

SERVICE MANUAL Undercounter Refrigerator Drawer Units

GCG-9. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-9-N13EB G-9-N13EB GCG-9-B13EB UPRIGHT COOLER

Steamer Display Cabinet Model SDC-500 NIT A T D CM I S T E D. P/N Rev. D 03/12. Owner s Manual

BMW E36 Thermostat Removal And Coolant Flush

REF Series Undercounter Refrigerator

Installation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

Installation & Operations Manual for R-290 SERIES. BMG-HGP Model Bottom Mounted Full-Length Swing Glass Door Refrigerator Merchandisers 2/

Instruction Manual. 36 in. and 42 in. Popcorn Staging Cabinets

MC MC MC MC MC833130

Model PF 2030 Wide Area Vacuum Cleaner

INSTALLATION & OPERATION MANUAL

OPERATING INSTRUCTIONS

BMG-HGP & BMG-SLP Model Bottom Mounted Full-Length Glass Door Refrigerator Merchandisers

Concepts Serving Systems

P P P P P

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

Glass Door Refrigerators

Installation Electric Dryers Instructions 01

OPERATING INSTRUCTIONS

Instruction Manual. Table Top Steamer Cart

Instruction Manual. Fun Pop 4oz Popper

READ AND SAVE THESE INSTRUCTIONS

As part of the V.I.P. family, you are entitled to the best protection by one of the most comprehensive warranties in the industry.

BACK BAR REFRIGERATION Installation, Operation and Maintenance Instructions

Transcription:

INSTRUCTIONS FOR USE C5 4 SERIES INSULATION ARMOUR PLUS HOT FOOD HOLDING CABINETS TABLE OF CONTENTS Safety Information...2 Safety Symbols...2 Identify your Cabinet...2 Product Details...3 Installation and Setup...4 Reversing the Door Hinging (Solid and Clear)...5 Operating Instructions...9 Care and Maintenance...9 Basic Troubleshooting...10 Service and Replacement Parts...11 Service and Replacement Parts (Circuits)...13 Warranty...14 Metro Heated Cabinets are for Hot Food Holding applications only. DESCRIPTION This manual covers cabinets with electrical ratings of: 120V, 60 Hz, 1400W and 220-240V, 50/60 Hz, 1176-1400W 2017 InterMetro Industries Corporation, Wilkes-Barre, PA 18705 Rev. D 10/2017

C5 4 Series Insulation Armour Plus SAFETY INFORMATION CAUTION: This cabinet is only for hot food holding applications. Follow all food safety guidelines. Pre-heat the cabinet to the desired temperature before placing hot cooked food into the cabinet. Food must be at the appropriate temperature before being placed into cabinet. Use a food probe to check internal food temperature - the cabinet temperature is not necessarily the internal food temperature. Only factory approved service agents must attempt to service, repair or replace electrical components, wiring or power cord. Unplug the cabinet before cleaning or servicing. Do not wash the cabinet with a water jet or high pressure water, do not hose wash/spray interior. Food Service Equipment must be electrically grounded. Failure to ground Food Service Equipment may result in serious injury or death from electrical malfunction. Do not spray or pour water into the top of the cabinet (control enclosure). Unplug the cabinet before cleaning and then wipe with a damp cloth and dry with a towel. Use only cleaning agents approved for stainless steel. SAFETY SYMBOLS! HAZARDOUS VOLTAGE! Disconnec t power beforeservicin gor cleaning. IDENTIFYING YOUR CABINET For future reference, note the serial and model number found on the data plate of the cabinet here: Serial number Date the cabinet was put into service Fill out and return the warranty card located at the back of this manual. Part Numbering CABINET NAME CABINET SERIES C5 4 9 _X - A _ S _ FS _ - U _ A _ ACCESSORIES (IF APPLICABLE) SLIDES U = UNIVERSAL L = LIP LOAD CABINET HEIGHT 9 = FULL 8 = 5/6 5 = 1/2 3 = Under Counter BLANK = 120V X = 220-240V CONTROL ANALOG MATERIAL S = STAINLESS STEEL DOOR STYLE FS = FULL SOLID DS = DUTCH SOLID DOOR DC = DUTCH CLEAR DOOR FC = CLEAR DOOR (UNDER COUNTER) 2

INSULATION ARMOUR Plus TM 100 80 60 120 140 F 30 10 50 C 60 150 160 170 180 190 70 80 90 100 105 InterMetro Industries Corp. METRO.COM 220 200 210 C5 4 Series Insulation Armour Plus PRODUCT DETAILS ON/OFF Switch Power Cord Heating Module 4 Series Thermostat Thermometer Control Panel Universal Slide Armour Panel (Left-Right-Back) Door Door Handle (2) Swivel Casters (2) Brake Casters Air Chimney Upright INSTALLATION AND SETUP 1. Check the packaging and cabinet for shipping damage after unloading the unit, and after removing all the packaging. 2. The receiver of this product is responsible for filing freight damage claims. This equipment must be opened immediately for inspection. All visible damage must be reported to the freight company within 48 hours and must be noted on freight bill at the time of delivery. 3. Concealed damage is your responsibility you must advise the carrier of any loss or damage within 15 days after receipt of the cabinet. If there is damage, retain the original packaging for inspectors. 4. Any protective covers (plastic or paper sheet) on the sheet metal, if applicable, must also be removed before turning the cabinet on. 5. To change the position of the power cord, first make sure the cabinet power switch is off and the power cord is unplugged from any electrical outlet. Remove the screws holding the cabinet top in place. Remove the screws on the rear of the cabinet that hold the cord bracket in place. Rotate the power cord bracket 90 to the desired position and reattach it with the screws to the back of the cabinet. Make sure the green ground wire connection and the wire nuts on the black and white wires have not loosened. Do not alter the wiring of the power cord to the cabinet. Replace the cabinet top and the screws holding it in place. 6. Refer to the data plate located near the power cord for the electrical specifications of the cabinet as shown on Page 2. With the POWER switch OFF, plug the cord into the appropriate rated, grounded receptacle. Cabinets rated at 120V 1400W must be plugged into a 15 amp 125 VAC receptacle. Cabinets rated at 220-240V must be plugged into a 15 amp 250 V receptacle. Cord Out of the Top Cord Out of the Back 15 Amp Outlet For 120V Cabinets 250 VAC 15 Amp Outlet (For All 220-240V Cabinets) G Figure 1: Power Cord Location on Cabinet Figure 2: Wall Receptacles 3

C5 4 Series Insulation Armour Plus CAUTION: Slide Installation Do not allow combustible materials to be stored or accumulate on, under or next to the cabinet. Do not block any ventilation louvers or slots. Allow 18" (46 cm) between the Armour panels and any cooking equipment. Do not allow hot kitchen equipment whose surfaces exceed 200 F (90 C) to touch the panels. The universal rack uprights or lip load slides have been installed at the factory. If removed for cleaning, reinstall by hanging them on the rack hangers on the side walls of the cabinet. Slide Position to Maximize Universal Slide Pan Capacity when Slides are Spaced on 3" Centers 28 29 For additional pairs of wire slides, order C5-USLIDEPR-C for Chrome or C5-USLIDEPR-S for Stainless Steel. To order individual universal uprights only, see item # 29. Fixed Lip Load Slide Configurations LS Complete set of universal slides and uprights for full height cabinet Part No. RPC54-9-URACK 17 Levels LS 27 LS Complete set of universal slides and uprights for 5/6 height cabinet Part No. RPC54-8-URACK 14 Levels Complete set of universal slides and uprights for 1/2 height cabinet Part No. RPC54-5-URACK 8 Levels Complete set of universal slides and uprights for under counter cabinet Part No. RPC54-3-URACK 5 Levels NOTE: Lip load slide racks include adjustment screws to help accommodate variations in sheet pan sizes from different pan manufacturers. Turn the screw clockwise to tighten the slides, and counter-clockwise to loosen them. Full, 5/6, and ½ height cabinet racks have (4) adjustments points on each rack, and under counter cabinet racks have (2) adjustment points. LS LS LS LS LS Complete set of lip load slides for full height cabinet Part No. RPC54-9-LRACK Complete set of lip load slides for 5/6 height cabinet Part No. RPC54-8-LRACK Complete set of lip load slides for 1/2 height cabinet Part No. RPC54-5-LRACK Complete set of lip load slides for under counter cabinet Part No. RPC54-3-LRACK NOTE: Full and half height fixed lip load slides have two slots on the uprights, always use lower slot (LS) to install on rack hanger. 4

C5 4 Series Insulation Armour Plus REVERSING THE DOOR HINGING (SOLID AND CLEAR) The door on your cabinet can be reversed to accommodate a right- or left-hand opening. To reverse, follow the instructions listed below:w A B C Door Plate - Top CABINET WITH FULL LENGTH DOOR D CABINET WITH DUTCH DOORS Lift the Complete Door Assembly from Bottom Hinge and set it aside for Re-installation. Lift the Complete Top Dutch Door Assembly from Bottom Hinge and set it aside for Re-installation. CAUTION: Do not damage the door gasket and carefully set the door aside. 5

C5 4 Series Insulation Armour Plus CABINET WITH FULL LENGTH DOOR E-1 CABINET WITH DUTCH DOORS Top Hinge Top Hinge E-2 Bottom Hinge Bottom Hinge E-3 F-1 NOTE: Install hinges on opposite side Remove latch strike plate from left side. F-2 Install latch strike plate on the right side. 6

C5 4 Series Insulation Armour Plus CABINET WITH FULL LENGTH DOOR G Cabinet with Door Handle on Left Side and Hinged on Right Side Dutch Cabinet with Door Handles on Left Side and Hinged on Right Side CABINET WITH DUTCH DOORS Top Door Handle Door Handle Fasteners Door Plate Bottom NOTE: Keep these pair of fasteners (4x) for re-installation. NOTE: Keep these pair of fasteners (2x) for re-installation. Bottom Door Handle Fasteners Door Plate Bottom Door Plate Bottom H I Top Dutch Door Assembly Rotate the door 180 about vertical axis and note the position of fasteners. Fastener on Top Fastener on Bottom Fastener on Bottom Bottom Dutch Door Assembly 7

C5 4 Series Insulation Armour Plus CABINET WITH FULL LENGTH DOOR J Door Handle on Right Side of the Cabinet CABINET WITH DUTCH DOORS Dutch Door Handles on Right Side and Hinged on Left Side K L Install Door Assembly on Bottom Hinge M N THIS STEP COMPLETES REVERSING THE DOOR HINGING 8

InterMetro Industries Corp. METRO.COM C5 4 Series Insulation Armour Plus OPERATING INSTRUCTIONS NOTE: Before using your cabinet for the first time clean cabinet thoroughly as described below, heat the cabinet to maximum temperature for 90 minutes to burn off oils left from manufacturing process. During this process slight smoke may be seen. Power-Up and Pre-Heat Red ON/OFF switch is located on left side of control panel which is used to turn ON the cabinet. The red indicator light next to the switch indicates when the cabinet power is ON. The thermometer indicates the internal cabinet temperature. An amber indicator light is located between the thermostat and the thermometer and indicates when the thermostat cycles on to energize the heating element (to increase the cabinet temperature). When this light is not illuminated, it means the cabinet has reached the preset temperature level. It is normal for the thermostat to cycle on and off as the cabinet is operating. 1. Set the thermostat to the desired setting, and allow the cabinet to preheat without any food inside. The time required to reach the desired temperature is dependent upon the set point and ambient temperature where the cabinet is located. Setting 6 will produce a cabinet temperature of approximately 150 F (66 C) after allowing the cabinet to preheat for 30-40 minutes. Follow all food safety guidelines. Pre heat the cabinet to the desired temperature before putting cooked, hot food into the cabinet. This is not a re thermalization cabinet. Food must be at the appropriate temperature before being placed into this cabinet. 2. An amber indicator light next to the thermostat indicates when the temperature heater element is energized. As the thermostat setting is adjusted, it may take a few moments for the status of the indicator light to reflect the new control setting and cabinet condition depending on when in the thermostat cycle the setting is changed. 4 Series TM INSULATION ARMOUR Plus 120 100 80 60 140 F 30 50 10 C 150 160 170 180 60 70 80 90 105 100 190 220 200 210 C05-1143 CARE AND MAINTENANCE Before proceeding with any maintenance activity strictly follow Safety Information on page 2 of this manual. Cleaning The Cabinet CAUTION: CAUTION: ON/OFF Switch Red Thermostat Amber Thermometer Indicator Light Indicator Light Unplug the cabinet before cleaning or servicing. Do not wash the cabinet with a water jet or high pressure water. Do not spray or pour water into the control enclosure. To clean the cabinet, wipe with a damp cloth and dry with a towel. Use only cleaning agents approved for stainless steel. Do not use cleaners with chlorides or phosphates as they may cause damage to stainless steel. 1. Make certain that the cabinet has cooled down before cleaning. Use cleaners in proper concentrations. Follow the manufacturer s directions for the cleaning product used. The floor of the cabinet may be hosed out with low pressure water. After using any cleaning products, thoroughly rinse all surfaces to remove residue. 2. Use a damp cloth or sponge. Mild soap suitable for stainless steel is acceptable. Dry with a clean towel. Wipe up spills as soon as possible and regularly clean the cabinet to avoid staining and difficult to clean conditions. Cabinet Maintenance All Models This cabinet has been designed to require very little maintenance. Keeping the casters free of dirt build-up will go a long way in prolonging their life. Regularly inspect the casters. Tighten loose fasteners and replace worn or damaged parts with new InterMetro approved parts. Replace worn or damaged casters immediately. 9

C5 4 Series Insulation Armour Plus Armour Panel Cleaning Use soft cloth, mild soap water solution to clean lightly-soiled surfaces. Then wipe dry with a clean, soft cloth. For heavily-soiled areas, use a soft brush and solvent or emulsion-based cleaner. Always ensure the cleaner is recommended for use on plastics and follow any special instructions from the manufacturer. BASIC TROUBLESHOOTING Only factory approved service agents must attempt to service, repair or replace electrical components, wiring or power cord. 1. Controls do not work (no indicator lights): Check that the cabinet is plugged-in. Check that the outlet has power. Check that the power switch is in the On position. Check the cabinet wiring from the power cord to the power switch and to the thermostat. 2. Temperature too hot: a. During initial pre-heat, cabinet may overshoot set point. b. If displayed temperature exceeds 220 F (104 C): Blower wiring is faulty or disconnected. Blower needs replacing. The thermostat may have failed and the thermal cut-out device is controlling the temperature. Thermal cut-out device may have failed. 3. Temperature too low: a. The cabinet may still be in pre-heat or recovering from the door being opened. b. Door(s) is not closed or sealing properly. c. Worn out door gaskets. Replace gaskets. d. Blower is not circulating air: Blower wiring is faulty or disconnected. 4. No heat generated a. If the heat indicator light is on but the cabinet does not draw approximately 12 amps for 120V units and 6 amps for 220-240V units. Air heater element may be faulty. The wiring to the air heater element may be faulty or disconnected. Thermostat may be faulty. The thermal cut out may be open or have any disconnected wire coming to it or going from it to the element. b. If the heat indicator light does not come on, the thermostat may be faulty. The hot (BLK) wire may not be connected from the terminal block to the thermostat. 5. Indicator light is not working: It is rare that an indicator light is defective but it is possible. The thermostat contacts may not be closing and therefore the heater element is not being energized. Check the thermostat and indicator light and their respective wiring. 10

C5 4 SERIES SERVICE AND REPLACEMENT PARTS* CONTROL PANEL C5 4 Series Insulation Armour Plus Only factory approved service agents must attempt to service, repair or replace electrical components, wiring or power cord. CABINET BODY Item# Replacement Part No. Description Item# Replacement Part No. Description 1 RPC13-721 Thermostat 22 RPC02-381 2" Swivel Caster (Under Counter) 2 RPC09-213 Thermostat Mounting Cup RPC02-382 2" Swivel, Brake Caster (Under Counter) 3 RPC06-913 Knob B5DN 5" Swivel Caster 4 RPC13-375 Master Switch B5DNB 5" Swivel, Brake Caster 5 RPC13-218 Analog Thermometer RPQC02-247 6" Swivel Caster 6 RPC13-246 Amber Indicator Light RPQC02-248 6" Swivel, Brake Caster 7 RPC13-245 Red Indicator Light 22A B5DNR 5" Rigid Caster TOP MODULE 22B RPC5-SSLEG-1 Stationary Equipment Leg (Qty.1) 8 RPC11-191 Intake collar 24 RPC54-8-REDPNLF RPC54-9-REDPNLF Armour Panel with Screws (FOR PANEL IDENTIFICATION SEE CHART) 9 RPHM20-2103 Blower 120V 25 RPC53-HGRKIT Replacement Rack Hanger Kit 9A RPHX20-2103 Blower 220-240V 50/60 HZ 26 RPC54-9-URACK Full Height Universal Slide Assembly 10 RPC13-114 Element 120V, 1360W RPC54-8-URACK 5/6 Height Universal Slide Assembly 10A RPC13-1109 Element 240V, 1360W RPC54-5-URACK 1/2 Height Universal Slide Assembly 11 RPC13-198 Thermal Cutout RPC54-3-URACK Under Counter Universal Slide Assembly 12 RPC13-348 Power Cord 125V 15A Right Angle Plug 27 RPC54-9-LRACK Full Height Lip Load Slide Assembly RPC13-337 Power Cord, 125V, 15A Twist Lock Plug RPC54-8-LRACK 5/6 Height Lip Load Slide Assembly RPC13-289 Power Cord, 125V, 15A Straight Plug RPC54-5-LRACK 1/2 Height Lip Load Slide Assembly 12A RPC13-247 Power Cord, 250V, 15A Straight Plug RPC54-3-LRACK Under Counter Lip Load Slide Assembly 13 RPC13-083 Strain Relief 28 C5-USLIDEPR-C Chrome Wire Slide, 1 Pair 14 RPC13-096 Terminal Block C5-USLIDEPR-S Stainless Steel Wire Slide, 1 Pair 15 RPC07-055 Sensor Cable Grommet 29 RPC54-9-UNIVUP Individual Full Height and 1/2 Height Universal Upright 16 RPC5-SCLP Sensor Clamps and Screw RPC54-8-UNIVUP Individual 5/6 Height Universal Upright CABINET BODY RPC54-3-UNIVUP Individual Under Counter Universal Upright 17 RPC06-1130A Full Height Door Gasket 30 RPC54-TRVL Travel Latch RPC06-1130B 5/6 Height Door Gasket 31 C5-SHELF-S Wire Shelf (Used with Universal Uprights) RPC06-1130C RPC06-1130D 1/2 Height and Dutch Door Gasket Under Counter Door Gasket 18 RPC54-9SFS-DOOR Solid Full Height Door Assembly RPC54-8SFS-DOOR Solid 5/6 Height Door Assembly RPC54-3SFS-DOOR Solid Under Counter Door Assembly RPC54-3SFC-DOOR Clear Under Counter Door Assembly 18A RPC54-9SDS-TDOOR Solid Top Dutch Door Assembly RPC54-9SDC-TDOOR Clear Top Dutch Door Assembly 18B RPC54-9SDS-BDOOR Solid Bottom Dutch and 1/2 Height Door Assembly RPC54-9DC-BDOOR Clear Bottom Dutch Door Assembly 19 RPC14-118A Door Latch Flush Handle 20 RPC54-BOTHINGEASY Bottom Hinge Assembly ARMOUR PANEL IDENTIFICATION Height Top Panel Bottom Panel Full Height RPC54-9-REDPNLF RPC54-9-REDPNLF 5/6 Height RPC54-8-REDPNLF RPC54-9-REDPNLF 1/2 Height --- RPC54-9-REDPNLF Under Counter --- RPC54-8-REDPNLF 21 RPC54-TOPHINGEASY Top Hinge Assembly *CHECK DATA PLATE ON REAR OF CABINET TO CONFIRM CABINET VOLTAGE BEFORE SELECTING PARTS 11

C5 4 Series Insulation Armour Plus C5 4 Series Tall Cabinet Replacement Parts Diagram 12 13 27 26 30 24 21 25 NOTE: For armour panel identification see chart on page 12. 24 31 19 24 24 22A 18 FULL DOOR 20 17 29 28 22B 22 Brake (x2) 22 Swivel (x2) 13 12 12A 21 9A 9 18A 17 11 20 21 2 14 8 18B 17 4 1 7 3 6 5 10 10A 20 15 16 DUTCH DOOR 16 12

C5 4 Series Insulation Armour Plus 20 MASTER POWER SWITCH 22 RED LIGHT 23 12 4 7 24 HEAT THERMOSTAT 1 AMBER LIGHT 6 BLACK 16" THERMOMETER 5 THERMOMETER BULB WIRE NUT 19 BLACK 8.50" SPADE TO RING BLACK STRAIN RELIEF BLACK X 26" SPADE TO WIRE NUT WHITE BLACK 8.50" SPADE TO RING WHITE X 28" SPADE TO WIRE NUT GREEN POWER CORD 13 BLACK 16" 21 30" 24 23 22 20 19 BLACK X 12" RING TO SPADE WIRE NUT 24 23 22 21 20 19 30" GROUND STUD G BLACK 16" 12 18 17 12 11 10 9 6 5 4 3 16 15 14 13 TERMINAL BLOCK BLOWER GREEN WIRE 6 3 MOTOR 21 BLACK X 12" RING TO SPADE 8 1 10 10A AIR ELEMENT THERMOSTAT BULB BLACK X 26" SPADE TO SPADE THERMAL CUT OUT A A BLACK X 30" WHITE X 30" 15A RT ANGLE PLUG SHOWN 12 6 2 8 5 4 2 8 2 7 1 1 4 5 3 SERVICE AND REPLACEMENT PARTS (CIRCUIT) 11 13

C5 4 Series Insulation Armour Plus 10/2017 14

C5 4 Series Insulation Armour Plus Thank you for purchasing a Metro C5 4 Series Cabinet. We are certain you will be more than satisfied with its quality and performance. Please fill in the warranty information space below so we may register your warranty. Also, so that we may learn more about our customers and hopefully be of continued service in the future, please take a moment to fill in the customer information space below. Thank you CUSTOMER INFORMATION 1. Which one of the following best describes your establishment? a. Full-Service Restaurant b. Banquet Hall c. Hotel/Motel d. Hospital/Nursing Home e. College/University f. School g. Employee Feeding h. Other WARRANTY INFORMATION: Cabinet Model No. Date Purchased Customer Name Address Phone No. For warranty coverage please fill out this card and return it to Metro, or go to www.metro.com/heatedcabinetsupport and select Online Warranty Registration to register electronically. FOLD HERE DO NOT DETACH 2. Please indicate the two product benefits that were of major interest to you. a. b. c. d. e. f. g. Energy efficiency Stainless steel construction Top mounted controls Armour panels Slide selection Easy-to-clean design Other 3. Main factor that led to your decision to pur chase this product? a. Product operating and functional features b. Overall quality c. Price d. Availability e. Other 4. Three sources that led to the purchase of his product in the order of their impact (1 being most impact; 3 being least impact). a. Trade Journal Ad b Trade Show c. Sales Call d. Direct Mail e. Previous Purchase f. Other 15

C5 4 Series Insulation Armour Plus FOLD HERE DO NOT DETACH NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES BUSINESS REPLY MAIL FIRST- C LASS PERMIT NO. 121 WILKES-BARRE, PA POSTAGE WILL BE PAID BY INTERMETRO INDUSTRIES CORPORATION ATTN: CUSTOMER SERVICE P O BOX A WILKES-BARRE PA 18705-9968 STAPLE HERE STAPLE HERE 20 STAPLE HERE US/Can: 1.800.992.1776 Corporate Headquarters (US): 1.570.825.2741 For Inquiries Outside of the U.S. and Canada, Visit www.metro.com/contactus Rev. D 10/2017 www.metro.com 16