Gary Parker Refrigerants Product Manager

Similar documents
Gary Parker Refrigerants Product Manager

The Changing State of Refrigerants. Gary Parker Refrigerants Product Manager

10/4/2013. The Changing State of Refrigerants

4/19/2013. The Changing State of Refrigerants

The Current Path of Refrigerants

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.

R-407A R-448A R-449A

The R-404A Challenge. Commercial Opteon Refrigerant Solutions - The New Industry Standard

DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION

ZERO ZONE USER GUIDE TO THE 2017 EPA RETAIL FOOD REFRIGERATION REGULATIONS

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

Oct. Newly Developed Refrigerants for Refrigeration, meeting Global Warming Regulations. Hitomi ARIMOTO / Product R&D Department, Chemicals Division

Chapter 2. Alternatives to HCFCs and their Characteristics

PREPARE FOR CHANGE LOW GWP ALTERNATIVES. November 17

DuPont Refrigerants. John McCormack Business Manager DuPont Chemicals and Fluoroproducts. R22 market and the ISCEON retrofit options

REFRIGERANT CHANGEOVER

Harold Ag & Mobile Products

Refrigerants. Retrofit Guideline. Commercial Refrigeration Systems Medium Temperature R-12, R-401A & R-409A to Solstice N13 (R-450A) & Genetron 134a

CO 2 transcritical FTE System Full Transcritical Efficiency

Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS

REFRIGERANT REPORT 20 A EN

Refrigerant changeover guidelines

A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.

Solstice 452A (R-452A) Reduced GWP and Discharge Temperature for Transport Refrigeration, Plug-Ins and Condensing Units

R-404A Alternative with Low Compressor Discharge Temperature

Low GWP alternative refrigerants to R404A

Refrigerant and Energy Regulations Update

Refrigerant & Energy Regulations Update

Refrigerants Management & Retrofits. Mike Saunders & Randy Tebbe Emerson Climate Technologies

CHAPTER 1 INTRODUCTION

A Primer on HFOs. Hydrofluoro-olefins Low-GWP Refrigerants. Brett Van Horn, PhD Arkema Inc.

New Refrigerants & Selecting Capital Equipment

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

AIRAH Victoria Refrigerants Update

Refrigerants and lubricants

HCFC to HFO Blend Retrofit Guidelines Commercial Refrigeration Systems

Understanding Applications for Alternate Refrigerants. Ron Bonear Emerson Climate Technologies

Section 1: Theory of Heat Unit 3: Refrigeration and Refrigerants

Low GWP Refrigerants for Air Conditioning Applications

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

REFRIGERANT REFERENCE GUIDE

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

System Considerations for Refrigerant Blends with Temperature Glide

Opteon XP10. Opteon XP10 Retrofit Guidelines to Replace R-134a. Refrigerant. Introduction. Important Safety Information

APPLICATION & SERVICE GUIDE

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Refrigerant Changeover Guidelines HFC R-404A/R-407A/C/F to R-448A/R-449A. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Oyelami S., Bolaji B. O.

A Comparison Between Refrigerants Used In Air Conditioning

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.

HCFC to HFO Blend Retrofit Guidelines Commercial Refrigeration Systems

Understanding Applications for Alternative Refrigerants

Energy Saving & Eco-Friendly Refrigerant

New Refrigerants Designation and Safety Classifications

Honeywell Refrigerants. Retrofit Guidelines. R-404A/R-507A to: R-448A Solstice N40

March 10, 2016 San Joaquin Valley RETA Meeting

Making equipment decisions

HCFC to HFO Blend Retrofit Guidelines Commercial Refrigeration Systems

Embraco Position Paper: Light Commercial Refrigeration

Refrigerants. Refrigerants with the Future in Mind

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

Reducing Refrigerant Leakage

A2L Refrigerants. Objectives 14/09/2017

Energy Use in Refrigeration Systems

Retrofitting Existing Systems

Seminar 34 Refrigerants Today, Tomorrow, and Beyond

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

AUTOFROST Technical Discussions

Stay in business: STOP installing R-404A / R-507A! R-404A R-507A

Japanese market and issue of Heat Pump Kenji Matsuda

BRA FACT FINDER Number 19

Experimental Evaluation of Refrigerant Mixtures as Substitutes for HFC134a

New Case studies on Low GWP alternative refrigerants for HFCs. ABHIJEET KUDVA

Update on Refrigerant Blends

Evaluation of HCFC Alternative Refrigerants

Update on Next Generation Low GWP Refrigerants for Chillers Products. Steve Kujak Director, Next Generation Refrigerant Research

Natural Refrigerants.

Opteon XP40. Opteon XP40 Retrofit Guidelines to Replace R-404A/R-507. Refrigerant. Introduction. Important Safety Information

Use of R1234yf, R744 (CO 2 ) and R134a in automotive air conditioning

Ammonia. Background on ammonia as a refrigerant

Effectively Managing the Transition to Lower GWP Refrigerants

IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT

Maneurop reciprocating compressors MT / MTZ

Evaluation of Vapour Compression Refrigeration System Using Different Refrigerants

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

Industry co-operation on Natural Refrigerant technology development Kenji Matsuda

International Journal of Advance Engineering and Research Development

Australian Journal of Basic and Applied Sciences. Investigation of New Eco Friendly Refrigerant Mixture Alternative to R134a in Domestic Refrigerator

Scroll Chillers: Conversion from HCFC-22 to HFC-410A and HFC-407C

S I R. A Dewi Garcia MSc, MInstR C. Introduction to Harp International Limited. Your log

Chillers for High Ambient Conditions: What Technologies and Fluids?

Refrigerant Glide and Effect on Performances Declaration

Sustainable Refrigerant Solutions for HVAC-R. Laurent Abbas, Wissam Rached, Brett Van Horn

R134a Refrigerant Charging Chart Trucks Mybooklibrary

The natural solution for domestic refrigeration

Honeywell Refrigerant Update

Study of R161 Refrigerant for Residential Airconditioning

Refrigerant Rule Update

Transcription:

Gary Parker Refrigerants Product Manager

Refrigerant f i t History Status of the HCFC ( R22) Phase out Ozone Friendly Alternativesti Choosing the Best Retrofit Solution Lubricants and how they impact performance Refrigerant Blends and how to apply them Changes in the Legislative Landscape Global Warming What it means to you and your customer New Generation Alternatives HFO Refrigerants

Ozone Friendly Alternatives Most all Refrigerant Blends are a mixture of some or all of the following components. HFC R-32, R-125, R-134a, R-143a Hydrocarbon R-200 Series(Propane), R-600 Series (Butane) The mixture and percentage of each component varies depending on the target application for the blend. Design Factors include capacity, mass flow and oil miscibility. (R290/R600) d l l il i Mi l Oil (R290/R600) used solely to promote oil return in Mineral Oil systems, and impact performance.

Blend composition

Low Temperature R22 Alternatives

Low Temperature R22 Survivors

HT/AC R22 Alternatives

HT/AC R22 Survivors

Lubricant Choice and the Effect on Performance Proper Oil Return is critical for any Refrigeration or AC System. Miscibility between the refrigerant and the oil is essential. Some refrigerants claim to be no-oil-change solutions. In most cases, they have a very narrow application window and lower capacity. With a non-miscible combination oil logging can occur, which impacts compressor life and performance. Have you ever added oil? It is now widely agreed that only percentage of POE is required to ensure proper oil return. System design and operating temperature will play a key role in determining that %. Additives are now being marketed (Super Change) that improve miscibility, limited to basic close coupled systems..

Liquid id Receivers & Hydrocarbon Blends Hydrocarbons (Propane-Butane) are used to help with HFC- mineral oil/ab miscibility. The hydrocarbon only assist oil return in the gas or vapor state, t using velocity to move the oil. In the liquid form, hydrocarbons are of no assistance and the oil can get stranded on top of the refrigerant. To ensure proper oil return, you need to use a truly miscible combination (HFC + POE)

Elastomers Seals and Leaks Myth There is a belief that introducing POE oil into a system causes a breakdown of seal material causing leaks Fact When an HVACR system is charged the rubber elastomers seals absorb refrigerant and swell. When you remove the HCFC refrigerant the elastomers will shrink to near their original size. When you re-charge the system with an HFC, the absence of Chlorine, reduces the absorption rate and the seal will not swell at the same rate. The retrofit process must include replacing all elastomers and o-ring 11

Elastomers Seals and Leaks Schrader Cores and Caps Open Drive Shaft Seals 12

Elastomers Seals and Leaks Evaporator Heat Reclaim Solenoid Pressure Valve Valve Regulator 13

Refrigerant Rfi tblend Characteristics ti All Blended (R400 Series) Refrigerants have some measure of glide. Glide is the temperature range in which evaporations or condensing occurs. PT Charts reference both Bubble and Dew points DewisusedtomeasureSuperheat Bubble used to measure Subcooling

Refrigerant Rfi tblend Characteristics ti Superheat To determine superheat, use the Dew point value. Procedure: Use gauges to determine the pressure at the coil outlet. Use a thermometer to get the temperature at the same point. Get the Dew temperature t from the Dew column. Superheat = Actual Temperature Dew Temperature. Example: Find the superheat on an R407C system when the pressure at the evaporator outlet reads 80 psig and your surface thermometer reads 60 F. 80 psig yields ~ 50.7 F (Dew point) Degree of Superheat = 60 F (50.7F) = 10.7 F

Refrigerant Rfi tblend Characteristics ti Subcooling To determine subcooling, use the Bubble point Value. Procedure: e Use gauges to determine the pressure at the coil outlet. Use a thermometer to get the temperature at the same point. Use the Bubble column temperature. Subcooling = Actual Temperature Bubble Temperature. Example: Find the subcooling on a system using R407C when the liquid id line temperature reads 110 F and the liquid id line pressure is 300 psig. 300 psig yields ~ 120.4 F Bubble point Degree of Subcooling = 120.4 F - 110 F = 10.4 F

Refrigerant Rfi tblend Characteristics ti Evaporator Looking at the Evaporator at 80 lbs Liquid would enter the Evaporator at Bubble Point 39.9F A combination of liquid and Vapor would exist until it reached the Dew Point of 50.7F Your actual Evaporator Temp will be near the Average 45.3 Always use the Average value for temperature controlled set points, and equipment selections. Assuming you wanted a 55f discharge air, and a standard 10f what would you do?

Refrigerant Rfi tblend Characteristics ti Condenser Looking at the Condenser at 300 lbs Vapor would enter the Cond. at Dew Point 128.4 F A combination of liquid and Vapor would exist until it reached the Bubble Point of 120.4F Your actual Coil temp will be near of the average 124.4F Always use the Average value for temperature controlled set points, and equipment selection. Assuming you wanted 125f condensing temperature and a standard d 20f TD What would you do.?

Legislative Changes Global Warming is now the focus. Carbon containing CFC, HCFC and HFC are categorized as to High Global Warmers. California Refrigerant Management Program took effect in 2012. Auto Makers and the Aerosols mfg are phasing out of R-134a. F-Gas Regulations are now in place in Europe. EPA Considering removal of SNAP approval on R404/R507/R134A. CFC are being gpurchased and destroyed for Carbon Credit Value.

Legislative Changes The EPA is considering the removal of SNAP approval for selected HFC s The Significant New Alternatives Policy (SNAP) Program is an EPA program to evaluate and regulate substitute refrigerants as part of the Clean Air Act R 134a - Ban Aerosol Propellants: January ar 2016*. *Some medical and technical applications would be except Stand Alone Refrigeration &Vending Machines: January 2016. Automotive: Model year 2021 R404A/R507A: Ban Stand Alone Refrigeration and Vending Machines: January 2016. g g J y Other Refrigerants: There are a number of other less popular refrigerants that would also be regulated by this change:

Next Generation Low GWP Alternatives HFO (Hydro-Fluoro-Olefin) Refrigerants look to be the future. HFO refrigerants fi have zero ozone depletions and dhave very low global blwarming potential. Chemical companies around the world are developing both Pure HFO and blended HFO/HFC Refrigerants, for use in a variety of industries and applications. HFO s are mildly flammable, a new A2L safety classification was created. System design, Blend composition and Energy Efficiency will all be balance against the A2L classification and could have a significant affect on the products that are ultimately made commercially available. HFO R1234YF I l i R134A i t ti AC F ll h t t t d f HFO R1234YF: Is replacing R134A in automotive AC. Full phase out targeted for 2020. Some auto makers are still considering natural refrigerants in this arena.

Next Generation Low GWP Alternatives R134A Replacements: R444A (Mexichem AC5) similar in capacity and flammability to R1234YF R445A (Mexichem AC6) similar in capacity with a GPW ~ 130 R450A (Honeywell Solstice N13) similar in capacity with a GWP ~ 600 R513A (DuPont Opteon XP10) similar in capacity with a GPW ~ 600 R404A/R507 Replacements: R448A (Honeywell Solstice N40) Similar capacity with a GWP < 1500 R449A (DuPont Opteon XP40 ) Slightly lower capacity with a GWP < 1500 R410A Replacement: R446A is an R410A replacement with a GWP < 700 R447A is an R410A replacement with a GWP < 700

Thank you! For More information go to: www.rsd.net/refrigerant Suite Or Call 1-800-245-8007 8007 ex 00405