Domestic. Pump Series CB and CBE Condensate Units SINGLE OR DUPLEX 1,000 THRU 140,000 SQ. FT. EDR-250 THRU 34,748 LB./HR.

Similar documents
Domestic Pump Series VCMD TM Combination Vacuum & Boiler Feed Unit

Hoffman Specialty Pump Products

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

ecocirc XL HIGH EFFICIENCY LARGE WET ROTOR PUMP FOR HEATING, COOLING AND POTABLE WATER SYSTEMS A-162C

SECTION STEAM CONDENSATE PUMPS

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Domestic Pump Condensate Transfer Equipment

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

Condensate Boiler Feed Water Make-Up

Hoffman Specialty Watchman Series WC & WCS Condensate Units Replacement Parts PART LISTS DN0436C

Elevator Sump Kits and Components

Stainless Steel Condensate Return Units

SECTION HEATING BOILER FEEDWATER EQUIPMENT

5. CONDENSATE PUMPS/UNITS

4600 SERIES. Technical Specifications. Condensate Units - Steel Tank. Features

Condensate Return Feedwater Systems For Low and High Pressure Steam Boilers

BuildingName The Description of the Project P DOCUMENTS

SIMPLEX WEATHERPROOF CONTROL PANELS

TECHNICAL BROCHURE BCPSDWWP R2 SIMPLEX/DUPLEX WASTEWATER DISCONNECT STYLE PANELS

FLANGE-MOUNT CENTRIFUGAL PUMPS

SECTION STEAM CONDENSATE PUMPS

TECHNICAL. Series 18. Pump Packages

/ / Take the technological step into MODERN Condensate Handling Equipment for steam systems MANUFACTURED IN AMERICA with craftsmanship and quality.

DualPak Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Sept. 28, DualPak 6900 Series Booster System

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. Condensate Return Systems General Installation, Operation, & Service Instructions !

SECTION STEAM AND STEAM CONDENSATE SPECIALTIES

FEATURES. Other Fed-Flush Arrangements

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Threaded. Flanged. Model PSH. Primary Secondary Header A-451

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

MARLOW PUMPS RECIRCULATION

DUPLEX CONDENSATE TANK SYSTEM

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

Mission Critical. Fuel Supply Systems

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

Lowara ecocirc and ecocirc PREMIUM

University of Houston Master Construction Specifications Insert Project Name SECTION FIRE PROTECTION PUMPS PART 1 - GENERAL

TECHNICAL BROCHURE BCALARM R4. Indoor and Outdoor Panels and Accessories

50/60 Hz. ecocirc BASIC Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS. ErP 2009/125/EC

Silhouette. Feedwater Heater. Boiler Feedwater

Deaerator. Specifications

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

MODEL P. 2 ft. NPSH Cast Iron Bronze Fitted Low NPSH Centrifugal Pumps. BULLETIN 112 Revised 7/09. PH (Horizontal Flange Mounted)

Water Piping and Pumps

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

SERIES: WT SELF-PRIMING CENTRIFUGAL PUMPS

.005 ATMOSPHERIC DEAERATOR

Custom Design TYPE CS

Domestic Pump Vacuum and Boiler Feed Units Series VCMD TM INSTRUCTION MANUAL DN0137 REVISION F

Custom Design TYPE SHM Steel Horizontal Make-up Boiler Feed Pumps and Custom Design TYPE SHEM. BULLETIN 107 Revised 5/17

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

SECTION PLUMBING EQUIPMENT

Type VSA Suspended Wet Pit Sewage Pumps BULLETIN 228E-1 September 2014

SECTION STEAM CONDENSATE PUMPS

SUMP PUMPS, EFFLUENT PUMPS AND SEWAGE PUMPS

SERIES: WT SELF-PRIMING CENTRIFUGAL PUMPS

INSTRUCTION MANUAL MM-601REVI. Series FS4-3 General Purpose Liquid Flow Switch

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.

Marine Heat Exchangers SALES SERVICE REPAIR

DESCRIPTION AND INSTALLATION

SERIES: WPT SELF-PRIMING CENTRIFUGAL PUMPS

SERIES: WPT SELF-PRIMING CENTRIFUGAL PUMPS

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

SECTION AIR COMPRESSORS AND ACCESSORIES

.03 ATMOSPHERIC DEAERATOR

Blockpumps. Vogel Series LSB. Lenntech. Tel Fax

CLOSED COUPLED CENTRIFUGAL PUMPS

DEAERATORS .005 ATMOSPHERIC DEAERATOR

70E Pressure Booster. Bell & Gossett. Bulletin D-215D. Efficient Operation. Easy to Select and Install. Quick Set-up through EZ Start

HHA Lyerly Apartments 75 Lyerly Houston, Texas J. Allen Management Managing Agent

Reciprocating Simplex and Duplex Tank Mount Compressor Systems Rev. 08/23/12

Extended Range. PRESFIX Packaged Pressurisation Sets AUTOMATIC MAKE-UP UNITS FOR SEALED HEATING AND CHILLED WATER SYSTEMS.

HHA Bellerive Apartments 7225 Bellerive Houston, Texas J. Allen Management Managing Agent

Reliable Long-Term Solutions For Your Toughest Pump

PIONEERS IN AIR VACUUMS

PUMPS & PUMPING SYSTEMS FOR THE CHEMICAL PROCESSING & HEATING & AIR CONDITIONING INDUSTRY

POULTRY MARKET CATALOG

Polymer Dilution Blend and Feed Specifications For General Use

INSTRUCTION MANUAL DN0136 REVISION D

GRUNDFOS FIRE PUMP SYSTEMS PEERLESS ENGINEERED SYSTEMS LISTED

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

Sioux E-Series. All-Electric Compact Industrial Steam Cleaners & Pressure Washers. Sioux E-Series All-Electric Steam Cleaners and Pressure Washers

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

J SERIES. Technical Specifications. Centrifugal Pumps for J Series Condensate & Boiler Feed Pumps. Features

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

GENYO Series ELECTRIC PUMP CONTROL AND PROTECTION SYSTEM

Wilo IL Vertical Split-Coupled Inline Pumps

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

Submersible Pumps. Series BERS

Lowara ecocirc and ecocirc PREMIUM

INSTRUCTION MANUAL MM-615E. Series FS1 High Sensitivity Liquid Flow Switch

Phillips. HORIZONTAL AND VERTICAL ASSEMBLIES For Ammonia (R-717) and Halocarbon Refrigerants

SECTION AIR COMPRESSORS AND ACCESSORIES

Boiler & Water Heater

COMING SOON. New Generation DCC1000 Vari-Vac Control Center Energy Management System

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

Enclosed Scroll Air Compressor System SES 3-5 HP

BOHEC R CRS86A DISHWASHER STANDARD FEATURES MODEL ACCESSORIES DIRECTION OF OPERATION VOLTAGE OPTIONS AT EXTRA COST

Volute Casing Pumps. Vogel Series LN/L ACCORDING TO EN 733 DE: +41 (0) FR: +41 (0)

Transcription:

Cast Iron Receivers: For years of dependable service; warranted for 20 years from date of shipment against failure due to corrosion. Each Receiver comes standard with Inlet connection, an overflow and minimum 2 NPT air vent connection. Series B-35 Pumps: The original low NPSH pump; two stage bronze construction. Standard 3500 rpm for best hydraulic efficiencies. Mechanical seals rated for 250ºF (121ºC) Float Switches: Durable pole heavy duty, externally adjustable CB Units: Floor mounted for low return lines Pumps condensate up to 210ºF (99ºC) at sea level CBE Units: Receiver is elevated 24 (610mm) above the floor to provide the required 2 ft. NPSHA Pumps condensate up to 212ºF (100ºC) at sea level Series CB Series CBE Domestic Pump Series CB and CBE Condensate Units SINGLE OR DUPLEX 1,000 THRU 140,000 SQ. FT. EDR-250 THRU 34,748 LB./HR. S-225J

SELECTION DATA 2

Series CB Standard Unit Features Cast iron receiver. All simplex receivers have a blanked opening for second pump. Cast Iron Receivers are warranted for 20 years from date of shipment against failure due to corrosion. Series B35 centrifugal pump(s) with drip-proof motors. Pump capacity sized 2 times system return rate. Float switch(es). Series CBE Standard Unit Features Cast iron receiver mounted on a welded steel stand. All simplex receivers have a blanked opening for second pump. Cast Iron Receivers are warranted for 20 years from date of shipment against failure due to corrosion. Series B35 centrifugal pump(s) with drip-proof motors. Pump capacity sized 2 times system return rate. Float switch(es). Suction piping isolation valves. Optional Features Water level gauge w/shutoff valve Dial Thermometer Inlet Basket Strainer Discharge Pressure Gauges Mechanical Alternator provides sequencing of duplex pumps and stand-by of second pump on high level. NEMA 2 U.L. Listed Control Panels see page 4. Suction Butterfly Valve (optional on Series CB Units only, on capacities to 75 gpm) Lifting Eyes Ordering Instructions Specify Model No., single or duplex, phase, operating voltage, special features. Note: TEFC motors are available. A horsepower increase is not necessary when using TEFC Motors. 3

ROUGHING-IN DIMENSIONS All dimensions in inches (mm) Not to be used for installation - CERTIFIED DIMENSIONS ON REQUEST SERIES CB CONDENSATE UNITS SERIES CB RECEIVER 4

ROUGHING-IN DIMENSIONS All dimensions in inches (mm) Not to be used for installation - CERTIFIED DIMENSIONS ON REQUEST SERIES CBE CONDENSATE UNITS SERIES CBE RECEIVER 5

OPTIONAL ELECTRIC CONTROLS Description of Optional Panel Components: Magnetic Starters must be used on all 3 phase motors and single phase motors over 2 HP. Disconnect Switches and Circuit Breakers. Either fuses or a circuit breaker is required ahead of the starters to protect against short circuits. A disconnect switch or circuit breaker also provides a means of shutting off power for service. Selector Switches Auto-Off-Hand selector switches provide a means of shutting off pumps and a means of testing in the Hand position. Off-Hand-Lead-Lag selector switches may be furnished on duplex units with 2 float switches to provide manual alternation. Electric Alternator may be furnished on duplex units to provide automatic sequencing of lead pump. Use only when magnetic starters are provided and only with 2 float switches. Transformer is required by the National Electrical Code to reduce control voltage when power supply exceeds 250 volts. A transformer is recommended when voltage exceeds 130 volts. Refer to local codes for requirements. Pilot Lights Pump running pilot lights are available to indicate pump operation. Audible Alarm An alarm to indicate low or high water level may by furnished. A separate tank mounted level switch should be provided with an alarm. Specified Panel Components to be furnished with unit at extra cost. Standard panels are supplied with NEMA 2 enclosures and are U.L. listed unless otherwise specified. 6

Notes 7

Xylem 1) The tissue in plants that brings water upward from the roots; 2) a leading global water technology company. We re a global team unified in a common purpose: creating advanced technology solutions to the world s water challenges. Developing new technologies that will improve the way water is used, conserved, and re-used in the future is central to our work. Our products and services move, treat, analyze, monitor and return water to the environment, in public utility, industrial, residential and commercial building services, and agricultural settings. With its October 2016 acquisition of Sensus, Xylem added smart metering, network technologies and advanced data analytics for water, gas and electric utilities to its portfolio of solutions. In more than 150 countries, we have strong, long-standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise with a strong focus on developing comprehensive, sustainable solutions. For more information on how Xylem can help you, go to www.xyleminc.com Instruction manuals, specifications and parts lists can be found on our website www.bellgossett.com We value your feedback. Please take our 3 question survey at bellgossett.com/survey to let us know how we are doing. Xylem Inc. 8200 N. Austin Avenue Morton Grove, Illinois 60053 Phone: (847) 966-3700 Fax: (847) 965-8379 www.bellgossett.com Bell & Gossett is a trademark of Xylem Inc. or one of its subsidiaries. 2018 Xylem Inc. S-225J January 2018