PCB-10 Condensate Recovery Systems

Similar documents
Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D

Pumps. Pressured-powered pump catalog. The more reliable and efficient way to pump condensate and other liquids.

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

Pump & Trap Combinations

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

Documento Descargado desde:

Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

FLOAT AND THERMOSTATIC STEAM TRAPS FLT17 (DN 1/2 to 1 ; DN15 to DN25)

MFP14 Automatic pumps for condensate and other industrial fluids

Mini Pump Trap. Features: n Low maintenance - No leaking seals, impeller or motor problems reducing maintenance and downtime.

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

PUMPS & PUMPING SYSTEMS FOR THE CHEMICAL PROCESSING & HEATING & AIR CONDITIONING INDUSTRY

/ / Take the technological step into MODERN Condensate Handling Equipment for steam systems MANUFACTURED IN AMERICA with craftsmanship and quality.

SECTION STEAM CONDENSATE PUMPS

Pamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Steam Ancillary Equipment. Primary Steam System, Water Treatment and Auxiliary Steam System Equipment

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

Pamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Williams & Davis Boilers

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS

Product. Add Efficiency To Your Steam Investment... Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits

YARWAY PROCESS THERMOSTATIC STEAM TRAPS SERIES 151 AND AV5

MFP14 Automatic pumps. for condensate and other industrial fluids

Williams & Davis Boilers

MECHANICAL VACUUM BOOSTERS:-

FT14 Ball Float Steam Trap (Screwed)

STEAM TRAPS

Let us first understand how costs / savings are calculated. We know that, Boiler Efficiency ( η ) =

Liquid Drainers LIQUID DRAINERS

Presentation On Industrial Boiler Operation And Maintenance

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

Steam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

LIQUIDATOR 450 SERIES

Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections

Stainless Steel Condensate Return Units

THERMOSTATIC STEAM TRAPS

Design and Construction Standards SECTION PLUMBING EQUIPMENT

2 X 1996 Wartsila 18V mw Each 50hz HFO Generator Sets

PRODUCTS. Expansion Joints Fire Fighting. Flexible Metal Hoses. Equipments. Insulation Solutions. Steam. Valves. Level Control.

Design of Air Pre-Heater for Blast Furnace Gas Fired Boiler

Condensate Return Feedwater Systems For Low and High Pressure Steam Boilers

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

SIOUX HYBRID WATER HEATER

Choosing the Right Pump

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)

Product Family Overview

SECTION PLUMBING EQUIPMENT

LIQUIDATOR UMT-TD Series Thermodynamic

CRU 200 and 500 Series Condensate Recovery Units

Tray ST5. Tray Type Deaerator Pressurized.005 cc/liter. industrialsteam.com

CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

Tighe&Bond. Groton Heights School Mechanical Evaluation. 1 Existing Conditions. 1.1 Water Service Entrance

THERMODYNAMIC STEAM TRAPS

Heat pump and energy recovery systems

PROVIDES TEPID WATER FOR EMERGENCY SHOWER

Water Heaters. Solar Applications

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet:

Heat Transfer Packages

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

FUEL-FIRED VERTICAL TUBELESS BOILERS

System Solutions. Efficient energy use, effective flash steam utilisation, and tailor-made customer solutions CHEMICAL THE STEAM SPECIALIST.

STEAM & POWER ENGINEERS

Steam and Gas Power Systems Prof Ravi Kumar Department of Mechanical and Industrial Engineering Indian Institute of Technology - Roorkee

Economical and simplified solutions that offer quality and optimum steam trap service.

Manufacturers Representatives Since Industrial Systems, Inc. Computer Support, Inc

Series 300 VTB. Installation Instructions

All rights reserved, Armando B. Corripio, PhD, PE, Solid Dryer Design Introduction Continuous Dryer Design...

NT1-P CONDENSATE NEUTRALIZATION TANK WITH PUMP INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

Gandhinagar Institute of Technology Mechanical Engineering (Thermal Engineering) Semester II. Design of Heat Exchange Equipments [ ]

Water Fuel + Air for combustion Blowdown

POWERENERGY

- Pamphlet A2404 TLV. ertrap a ic I Pump & Pump/Trap. GP Series GT Series

Products Solutions Services. Energy Solutions. Food & Beverage industry. Slide 2

APT and APT14 Automatic Pump Traps. for effective condensate drainage and removal

SALES TRAINING HEAT RECOVERY SYSTEMS BLOWDOWN SEPARATORS & TANKS LIQUID SAMPLE COOLERS ORIFICE METERS

Columbia Boiler Company

Steam Site Guide. Steam Site Guide. Heat Exchange Applications - SI Units

solar thermic system Solar thermic systems are devices that allow you to capture and store solar energy for later use in various utilization.

DUPLEX CONDENSATE TANK SYSTEM

Packaged Semi-Instantaneous Steam Fired Water Heater

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION

Packaged Steam Fired Water Heater

Condensate Boiler Feed Water Make-Up

MAXIFLO EJECTOR SYSTEM AN INNOVATIVE APPROACH TO STEAM CONSERVATION LEVEL 4 BEE ACCREDITED

Aldrich Blowdown Separators & Cooling Manifolds

INSTALLATION AND OPERATION MANUAL DIRECT STEAM COUNTER TILTING KETTLES MODELS: DC - 5 DC - 6 DC - 10 DC - 12 DC - 20

NHS Sustainable Development: 14 th February Reduce Energy Consumption Through Steam System Modernisation. National Key Account Manager

THERMODYNAMIC STEAM TRAPS

solar thermic systems

PIONEERS IN AIR VACUUMS

The right trap for the right application.

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction

CASE STUDY PAPER INDUSTRY

DRYING OF MILK SPRAY DRYING

Flash Separators. Celebrating 12 years of service to the Indian Process Industry. We sell Savings

Transcription:

Description: The Pennant condensate pump (PCP-10) is an excellent alternative to standard electric pumps which are not suitable for pumping hot condensate. It is a complete non-electric solution designed to lift condensate to the boiler feed-water tank, using small quantities of motive steam/air. Features: Intrinsically safe for use in hazardous areas since there are no electric connections Works in remote areas where electric supply is not available Not prone to wasteful leaks as there are no rotating parts with mechanical seals All stainless steel internals give excellent corrosion resistance for long trouble-free service Exceptionally low cost of operation and maintenance Sizes: (DN): 5 x 5, 40 x 40, 50 x 50, 80 x 50, 100 x 100 End Connections: Flanged #150, #300 as per ASME B16.5 Screwed (NPT/BSPT/BSP) Typical Configuration: Stand Alone Unit: A stand-alone unit consists of a pump tank, inlet-outlet check valves & internal pumping mechanism. Pump with R eceiver Tank: In this configuration, there can be multiple pumping units, all fed from one receiver tank. The entire assembly is mounted on a common base. Depending on the number of pumping units, these are classified as A) Simplex: One pumping unit with check valves and one receiver tank skid-mounted B) Duplex: Two pumping units with check valves and one receiver tank skid-mounted C) Triplex: Three pumping units with check valves and one receiver tank skid-mounted Limiting Conditions: PMA : Maximum allowable pressure TMA : Maximum allowable temperature PMO : Maximum operating pressure Cold Hydro Test Pressure 15 kg/cm 0 380 C 10.5 kg/cm 30 kg/cm

A: F or threaded ends. F: F or flanged ends Inlet x Outlet (DN) 5 x 5 40 x 40 50 x 50 80 x 50 100 x 100 Dimensions (mm) Weight (kg) A B C D E F Threaded Flanged 685 135 405 450 135 865 80 88 70 135 405 450 135 940 8 98 790 50 550 450 50 1015 100 18 845 50 550 450 80 1055 105 141 080 40 980 * 40 085-500 *Contact our representative for dimension D of the DN100 x DN100 version

Operation Principle: Liquid to be pumped enters the pump tank via the inlet check valve the vent valve is open and the steam/air valve closed. As the liquid level rises in the tank, the float rises. When the liquid level reaches its 'high level', the compression spring simultaneously forces the vent valve to close and the motive steam/air (pressure) valve to open. The pressure forces the liquid through the exit check valve. During the pumping cycle, the float drops as the liquid level recedes to the 'low level'. The action of the compression spring then simultaneously forces the vent valve open and the motive steam/air valve closed. Pressure in the pump tank is released through the vent, and liquid to be pumped enters through the inlet check valve repeating the cycle.

Capacity Chart for Selection: Motive Pressure (kg/cm ) 10.55 8.79 7 5.3 3.5 1.8 Total Lift (kg/cm ).8 4..8 4..8 4..8 4. 0.7 1.8.8 0.4 0.7 5 x 5 1159 1091 103 1159 1068 103 1159 1068 977 1114 1068 886 1114 1068 886 103 93 886 40 x 40 114 03 1750 114 03 1750 068 1886 1614 1886 1705 153 1773 1636 143 1864 177 1455 Capacities (kg/hr) Pump Size - Inlet x Outlet (mm) 50 x 50 3318 3091 955 3318 3091 955 373 3000 864 3314 864 455 3136 864 364 3000 773 500 80 x 50 5591 5091 5000 5591 57 5000 5500 5136 4864 5500 4818 418 5318 4818 4045 5136 477 473 100 x 100 19600 17314 15477 19545 1773 15455 18864 16636 14545 1877 157 11818 1877 15000 11136 *Contact our representative for check valve specifications. Use of any other check valve may alter pump performance. *

HOW TO SIZE THE CONDENSATE PUMP: In order to size the condensate pump, following information is required: Condensate load (kg/hr) Required delivery head (feet) Line pressure in the condensate return piping (kg/cm ) Available filling head (feet) Motive pressure (steam/ air/ gas) available for pump operation (kg/cm ) Example: Condensate load to be pumped: 730 kg/hr Required delivery head: 10 feet Pressure in the condensate return piping:.5 kg/cm Motive pressure: 7 kg/cm Step I Calculate the total back pressure against which the condensate must be pumped - Total back pressure = (Required delivery head X 0.03 ) + Pressure in the condensate return piping Step II = (10 x 0.03) +.5 =.8 kg/cm Select the pump from the capacity chart where the motive pressure is 7 kg/cm, total lift is greater than or equal to.8 kg/cm & condensate capacity is greater than or equal to 730 kg/hr. The resulting selection would be a DN 50 x DN 50 pump with a minimum required filling head of 1 foot. It will pump 3000 kg/hr providing an overall capacity of 110% of required flow. Optional Accessories: Cycle counter to count the number of pumping cycles Insulating Jacket to reduce radiation losses from the pump body Savings: Returning hot condensate to the boiler has several benefits: Savings in boiler feed-water - only make-up water required - return of high purity condensate saves cost of water treatment and saves water Fuel saving due to utilization of the energy from hot condensate Less condensate discharged into the sewer reduces disposal cost The mechanical (non-electric) operation of the PCP-10 saves the cost of power required to run an electric pump

Example of savings made: O Consider a steam system that returns 8500 kg/hr of condensate at 80 C using a PCP-10 condensate pump. Assume that this system operates 8000 hours annually with an average boiler efficiency of 80% and a make-up O water temperature of 10 C. The make-up water cost & sewage treatment costs for the plant is Rs.10 per cubic meter. The fuel cost is Rs.180 per GJ (gega joules) Annualsavinginrawwaterandtreatmentcosts: 3 3 = (Condensate Load, kg/hr) x Annual Operating Hours x (Total Water Costs, Rs./m )/(Water Density kg/m ) = 8500x 8000 x 10 1000 Annual water saving = Rs.6,80,000/- Annualfuelsaving: The condensate not returned to the boiler must be replaced by an equal amount of fresh make-up water. O O Heat required to raise the temperature of cold make-up water from 10 C to 80 C = m x Cp x T Q annual = 8500 kg/hr x 8000 hr x 4.19 KJ/kg x 70 = 19,944 GJ With the boiler running at an efficiency of 80%, The actual annual heat energy required would be = 19944/0.8 = 4930 GJ Considering a fuel cost of Rs.180 per GJ, The annual fuel saving will be : 4930(GJ) x 180 (Rs/GJ) = Rs.44,87,400/- Totalsavings duetoreturnedcondensate:6,80,000 + 44,87,400 = Rs.51,67,400/- Simplepaybackperiodconsideringcost ofinstallationofa condensaterecovery system is around30 to35 Weeks. (Local figures/conditionsmayvary fromtheassumptionsmadeintheexample) How to Order: PCP 10 :: 5 x 5 :: #150 Ordering Information: Condensate load (kg/hr) Required head for lifting condensate to the boiler feed-water tank (feet) Line Pressure/Back Pressure of Condensate return piping. Filling head available (feet) Motive pressure available for pump operation (kg/cm ) Stand-alone unit or skid with receiver tank (Simplex, Duplex, Triplex) Motive fluid available steam/air/gas

USA 10 Parsonage Road, Suite 31 Edison, N.J. [T] 877-597-TRAP (877) [F] 1-866-68-144 [E] info@pennantcorp.com pennantcorp.com INDIA 39, Sachapir Street, Camp, Pune 411001, Maharashtra [T] +91 0 6978 1118/9 [E] marketing@pennantcorp.com