Chiller units and air-water heat pumps RANGE OPERATING LIMITS

Similar documents
Personalized comfort for offices and shopping malls RANGE OPERATING LIMITS

Aquair BCP. Pool air handling units. Electronic Control Optimized energy consumption DESCRIPTION PRINCIPLE SCHEMES RANGE OPERATING LIMITS

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

Roof top SPACE RPC 450Z R407C M011

HCompact2 HA. Compact air-air stand-alone units. Compact horizontal Reduced dimensions Centrifugal fans RANGE DESCRIPTION OPERATING LIMITS SERIES

Roof top SPACE RPC 315Z R407C MA00

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

HCompact2 HA. HCompact2 RHA series Air to air cooling units. HCompact2 IHA series Reversible air to air heat pumps

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

High temperature air-to-water heat pumps

Process glycol chillers

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY

LZA High efficiency air to water heat pumps with HP compressor

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

LZT High efficiency air to water heat pumps with E.V.I. compressors

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Precision air handling cabinets Ciatronic MICRO/EXPAIR

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Water chillers water/water type SIGMA Technical information manual

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

air systems Roomtop RTC-RTH 15 to 30 - L

CHAPTER 6 CONDENSING UNITS

Aquaflair TRAC-TRAF-TRAH

MACH N-407 Heat Pump Air-Cooled Chiller

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

MAC N-407 Air-Cooled Chiller

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

Installation, operating and maintenance ECOLEAN - EAC/EAR

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

LDN Series. Trattamento dell aria SELECTION, INSTALLATION AND MAINTENANCE MANUAL

PRODUCT GUIDE

ULTIMATE ENERGY SAVING TECHNOLOGY

Application guide Installation, operating and maintenance manual AIRCUBE - KSCM/KSHM. Providing indoor climate comfort

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

TCHVZ TCEVZ

HYDRONIC RESIDENTIAL

LSN Series. Air cooled water chillers, heat pumps and motocondensing units with axial fans Capacities from 4 to 40 kw.


condenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications

Air cooled industrial chillers

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

TCHE-THHE TCEE

Galletti Water chillers and heat pumps catalogue

Air Cooled Chillers & Heat Pumps WinPACK HE-A

PAJ3. Product Specifications

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

Application guide Installation, operating and maintenance manual AIRCUBE - KSCM/KSHM. Providing indoor climate comfort

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

E U R O V E N T CERTIFIED PERFORMANCE

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: N

CONDENCIAT CD. Condensing units. Quiet operation Low speed fans All year round operation USE. Cooling capacity : 25 to 165 kw.

Flex Series Heat Pumps

york airside products Tailored air conditioning solutions Introducing the YORK YPRE range of custom air-to-air packaged roof top units

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

BRH. Climaveneta Technical Bulletin. Water-cooled liquid chillers ,5-35,1 kw. Versatile High efficiency Maximum silent-running

HT V2 HT Split

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

RMA AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Superchiller Product Documentation. English. cod rev Issued by TDS

LEP kw. Indoor monobloc water-water unit. Total heat recovery multi-purpose units LEP PLUS

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw

Transcription:

Chiller units and air-water heat pumps Cooling capacity: Heating capacity: 6, to 6,6 kw 8, to 69,4 kw ENVIRONMENTALLY FRIENDLY HFC R407C PROTECTION DE L'ENVIRONNEMENT Silent and compact design Air-conditioning solution where an outdoor installation is impossible DESCRIPTION Heat pumps and cooling units - ITB series are external air/water units of compact construction designed for indoor installation. These units produce cold and/or hot water, suitable for heating, cooling installations as well as for industrial applications. Equipped with centrifugal fan and plates exchanger. All units are tested and checked in factory. SERIES Series Air-condensed chillers. ITB Series Air-water reversible heat pump. RANGE Units with cooling circuit, compressor, 4 models: / 95 / 0 / 55. Units with cooling circuit, compressors, models: 95 / 55 / 5. OPERATING LIMITS SERIES ITB HEAT AIR PUMP WATER (outlet T) AIR COOLING WATER ( o utlet T) M AX. M IN. M AX. M IN. M AX. M IN. M AX. MIN. º C WB -7º CWB 55º C 0º C º C 4º C➀ 5º C 5º C➁ º C 4º C➀ 5º C 5º C➁ ➀ With condensing pressure control operating up to -7ºC WB. ➁ Minimum outlet temperature. For operating until -5ºC, glycol water is required. AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.65 A - N 6405 P

DESIGNATION series model example ITB-95 I = heat pump R = coolingonly unit TB - air-water units centrifugal fan plates exchanger reversible heat pump air wate r-unit with centrifugal fan model UNITS COMPOSITION Standard equipment - Anticorrosion casing in galvanized metal plate covered with a polyester and varnish lacquer. Chassis support. External circuit - Centrifugal fan(s) driven by motor or by belts and pulleys. - Coil with crimped aluminium fins and copper tubes. - Condensates drain pan. Internal circuit - Exchanger with stainless steel welded plates thermically isolated. Cooling circuit - Piston hermetic compressor with internal protection, mounted on antivibratory supports, with gas discharge silencer. - Crankcase heater (ITB serie). - Thermostatic expansion valve, with external equalization. - Antiacid dryer filter. - Liquid vessel (ITB series). - Four ways reverse valve (ITB series). Protections - HP and LP pressostats. - Water flow control by differential pressostat in - ITB model, and with flow switch in - ITB models 95 to 5. - Anti-frost protection, integrated in the control. - Main door switch. - Automatic circuit switch. - Motor fans and compressors circuits protection devices by circuit breaker fuse(s). - Fan thermal protection(s). Electrical panel - Complete electrical panel, totally wired. - General ground plug. - Compressor(s) and motor fan(s) contactor(s). Models to 55: S55E electronic control (consult manual) Control system by microprocessor equipped with: Control board Control of operating parameters and safeties management. Failures diagnosis. Anti-short-cycle timing. Defrosting in reversible units. Electronic thermostat: AQUAGES N Operating modes: cooling or heating. Display on LCD screen of the functions and configuration of unit operation in each moment. Introduction of the set point and operation mode. Memorization of operation parameters before lack of voltage. Alarm display. Models 95 to 5: GESCLIMA+ electronic control (consult manual) Control system by microprocessor equipped with: Control board Control of operating parameters and safeties management. Temperature probe for defrosting operation. Anti-short-cyle timing. Self-adapting control of compressor operating time, reducing the number of start-ups of the compressor and therefore reducing the power consumption and increasing the life span of components. It also allows to reduce the buffer tank size. Set point offset depending on external temperature. Possibility of communication with a building management system BMS with Modbus protocol. Electronic thermostat: DOMO Operating modes: cooling or heating. Operating parameters modification (set points, differential and timings). Time and daily scheduling. Night reduction mode. Alarm display by codes. Options - Coil of copper tubes and aluminium fins with polyurethane coating. - Options for control and controls. - Compressor acoustic isolation. - Condensing pressure control. - Air filter. - Flexible hydraulic connections. - Rubber anti-vibratory supports. 4 AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.65 A - N 6405 P

TECHNICAL CHARACTERISTICS ITB - SERIES 95 0 55 95 55 5 Cooling Capacities Heating Capacities Cooling capacity ➀ ( kw) 6, 8, 5, 9 0, 8 7, 0 8 6, 6 Power input ➂ ( kw) 7, 6 8, 9, 8 4, 6 7, 7, 7 9, EER Performance,,, 0,,, 0, Heating capacity ➁ ( kw) 8, 0, 9 7, 0 4, 7 4, 8 54, 0 69, 4 Power input ➂ ( kw) 7, 8,,, 8 6,, 7, COP Performance, 5, 6, 4, 5, 6, 4, 5 Nominal water flow (m / h), 8, 4, 5, 6, 4 8, 0, 6 Internal circuit External circuit Pressure drop (m.w.g.), 8,, 6, 5, 5, 8, 8 Number of circuits W ater inlet connection /4" /4" /" /" /" " " W ater outlet connection /4" /4" /" /" /" " " Nominal air flow (m / h) 6.500 7.000 0.000.00 4.000 0.000 4.400 Avail. static. pressure (mm.w.g) 7 7 8 7 8 Fan type CENTRIFUGA L Number Motor power (kw),, 5, ➄ x, 5 x, x➄ r.p.m. 60 678 650 67 678 650 67 Type PISTON HERMETIC Compressor Number of compressors Number of circuits Maximum power input Refrigerant ( R-4 07c) 0 V / III ph / 50 Hz (A), 7 4, 5, 7 6, 9 8, 0, 4 5, 8 400 V / III ph / 50 Hz (A) 5, 7 5, 6 4, 9 5, 64 85, 8 load (kg), 5, 6 5, 8 7, 7 7, 4, 6 4, 7 ITB load (kg), 5, 6 5, 8 7, 7 7, 4, 6 4, 7 Climate warming potential (CWP) ➃ 65, 5 Length (mm).74.74.0.0.6.704.704 Dimensions Width (mm) 88 88 877 877 88 8 8 Height (mm).7.7...7.. Weight (kg) 45 95 8 70 50 600 695 ITB (kg) 50 0 40 8 56 66 708 ➀ Cooling capacity for a water outlet temperature of 7 ºC and 5 ºC of outdoor temperature. ➁ Heating capacity for a water outlet temperature of 50 ºC and 6 ºC WB of outdoor temperature. ➂ Total power input by compressor(s) and motorfans in nominal conditions. ➃ Climate warming potential of one kg of greenhouse-effect fluored gas relative to one kilogram of carbon dioxide over a period of 00 years. ➄ In these models with vertical discharge it is necessary to change fan. AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.65 A - N 6405 P 5

MAXIMUM CURRENTS (A) Chiller units and air-water heat pumps - ITB SERIES 95 0 55 95 55 5 COMPRESSOR EXTERNAL FAN TOTAL 0 V / III ph / 50 Hz 9 5 4 5 x5 x4 x5 400 V / III ph / 50 Hz 7 6 x x7 x6 0 V / III ph / 50 Hz 4, 7 6, 8, 7, 9 x6, x8, 7 x, 9 400 V / III ph / 50 Hz, 7, 6 5 6, 9 x, 6 x5 x 6, 9 0 V / III ph / 50 Hz, 7 4, 5, 7 6, 9 8, 0, 4 5, 8 400 V / III ph / 50 Hz 5, 7 5, 6 4, 9 5, 64 85, 8 ELECTRICAL WIRING THE CONNECTIONS TO EXECUTE ARE THE FOLLOWING ONES: Nº DESCRIPTION 95 0 55 95 55 5 POWER SUPPLY 0 V / III ph / 50 Hz (±5%) 400 V / III ph / 50 Hz (±5%) + GND + N + GND THERMOSTAT CONNECTION x mm NOTE: If the unit is going to be installed in an industrial ambient with high level of EMC interferences, it is recommended to shield the wires of the control thermostat. NOTE: In 95 / 55 / 5 models the cooling/heating control is of two stages. NOTE: The installer should plan two wires of 0,75 mm in order to install an ON/OFF switch external to the unit. In ITB units, it is also necessary to provide three wires of 0,75 mm in order to install a cooling/heating switcher. CONTROL - ITB SERIES 95 0 55 95 55 5 COOLING CONTROL (ITB / ) HEATING CONTROL (ITB) ANTIFROST SAFETY (ITB / ) º C - º C 45 º C 45 - º C º C º C NOTE: Manufactured control: it is necessary to verify the water flow checking that the inlet and water outlet temperatures are between the operating limits. Other control values are allowed once verified that the flow and the temperatures are within the operating limits. 6 AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.65 A - N 6405 P

SOUND LEVEL GIVEN FOR 0 MMWG AVAILABLE PRESSURE Global sound pressure level at 5 meters from the unit, at.5 meters from the ground, in free field, directivity, with inlet and outlet connected to the duct: - ITB 95 0 55 95 55 5 db(a) 50 50 54 54 56 57 57 Global sound power level at the inlet (values to be taken into account for the calculatións of the silencers): - ITB 95 0 55 95 55 5 db(a) 74, 4 76, 8, 8, 79, 84, 86, Global sound power level at the outlet (values to be taken into account for the calculatións of the silencers): - ITB 95 0 55 95 55 5 db(a) 8 8 84 84 84 84 90 When planning the installation,take into consideration the location (residential area, housings, industrial area...) and if the radiated noise from the unit is higher than the noise estimated for the installation: An acoustic study. An appropriate acoustic treatment if necessary. Implementation precautions. COOLING CAPACITY (kw) Units compressor / stage / circuit ITB Chilled water outlet temperature in ºC Pf EXTERNAL AIR TEMPERATURE 9 ºC º C 5 º C 8 º C 40 º C º C Pa Pf Pa Pf Pa Pf Pa Pf Pa Pf Pa -4,00 5,50 0,60 5,60 0,0 5,75 9, 5,95 9,60 6,05 9,0 6,0 Glycol water -,0 5,70,70 5,,0 5,90 0, 6,0 0,60 6,5 0,0 6,40 0,0 5,90,70 6,00,0 6,0,90 6,0,60 6,45,0 6,60 4,0 6,0, 6,0,40 6,0,90 6,5,60 6,60,0 6, 5 5, 6,40 5,40 6,50 5,00 6,60 4,50 6, 4,0 7,00,60 7,0 6 6,40 6,50 5,90 6,60 5,50 6,70 5,00 6,90 4,70 7,0 4,0 7,0 Pure water 7 6,90 6,60 6,50 6,70 6,0 6, 5,60 7,00 5,0 7,0 4,60 7,40 8 7,50 6,70 7,00 6, 6,60 6,90 6,0 7,0 5, 7,0 5,0 7,50 0 8,70 6, 8,0 6,90 7, 7,00 7,0 7,5 6, 7,50 6,0 7,70 9,90 6,90 9,40 7,00 8,90 7,0 8,0 7,45 7,90 7,70 7,0 7, Pf: Cooling capacity in KW Pa: Power input by the compressor. These values can be interpolated, but never extrapolated AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.65 A - N 6405 P 7

DIMENSIONS SCHEMES / ITB / / 95 HORIZONTAL DISCHARGE H I J B P O C N R M Q F K L G S Condensates draining Gas thread M /4" E Keep this space free for installation and maintenance D A MODEL A B C D E F G H I J K L M N O P Q R S / 95.74 88.7 5 70 9.6 45, 5 475 6, 5 850 9 476 5 408 50 0, 5 LEGEND: AIR FLOW POWER SUPPLY AND ELECTRICAL PANEL WATER INLET WATER OUTLET Note: All models have 4 drills (8 mm diameter) for antivibratory - supports AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.65 A - N 6405 P

/ ITB - 0 / 55 HORIZONTAL DISCHARGE H I J B P O N C R M Q K L F G S Condensates draining Gas thr ead M/4" E Keep this space free for installation and maintenance D A MODEL A B C D E F G H I J K L M N O P Q R S 0 / 55.0 877. 5 759.8 9 7, 5.7 6, 5.7 8 790 6 94 00 50 0, 5 LEGEND: AIR FLOW POWER SUPPLY AND ELECTRICAL PANEL WATER INLET WATER OUTLET Note: All models have 4 drills (8 mm diameter) for antivibratory - supports AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.65 A - N 6405 P

/ ITB - 95 HORIZONTAL DISCHARGE H I J K B Q P O C S N R L M T Condensates draining Gas thread M/4" F G 750mm 000mm E 000mm D A Keep this space free for installation and maintenance MODEL A B C D E F G H I J K L M N O P Q R S T 95.6 87, 5.7 5 70 9.0 45, 5 475 9 6, 5.88 9 506 408 56 0, 5 LEGEND: AIR FLOW POWER SUPPLY AND ELECTRICAL PANEL WATER INLET WATER OUTLET Note: All models have 4 drills (8 mm diameter) for antivibratory - supports 4 AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.65 A - N 6405 P

/ ITB - 55 / 5 HORIZONTAL DISCHARGE H I J K B L M Q P O N C S R T Condensates draining Gas thread M/4" F G 750mm 000mm E 000mm D A Keep this space free for installation and maintenance MODEL A B C D E F G H I J K L M N O P Q R S T 55 / 5.704 8. 5 759 9.646 7, 5.7 47 6, 5.8 8 790 6 94 00 50 0, 5 LEGEND: AIR FLOW POWER SUPPLY AND ELECTRICAL PANEL WATER INLET WATER OUTLET Note: All models have 4 drills (8 mm diameter) for antivibratory - supports AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.65 A - N 6405 P 5

/ ITB - / 95 / 0 / 55 VERTICAL DISCHARGE (OPTIONAL) H I J O P N C R M Q K L F G S B Condensates draining Gas thread M /4" E Keep this space free for installation and maintenance D A MODEL A B C D E F G H I J K L M N O P Q R S / 95.74 88.7 5 70.6 9 45, 5 475 6, 5 850 9 476 59, 5 408 50 0, 5 0 / 55.0 877. 5 759.8 9 5 477 6, 5.7 8 790 9 408 00 50 0, 5 LEGEND: AIR FLOW POWER SUPPLY AND ELECTRICAL PANEL WATER INLET WATER OUTLET Note: All models have 4 drills (8 mm diameter) for antivibratory - supports 6 AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.65 A - N 6405 P

/ ITB - 95 / 55 / 5 VERTICAL DISCHARGE (OPTIONAL) H I J K P Q O C S N R L M T B F G 750mm Condensates draining Gas thread M/4" 000mm E 000mm D A Keep this space free for installation and maintenance MODEL A B C D E F G H I J K L M N O P Q R S T 95.6 87, 5.7 5 70 9.0 45, 5 475 9 6, 5 88 9 506 5 408 46 56 0, 5 55 / 5.704 8. 5 759 9.646, 5 475 796 6, 5.8 8 790 9 408 00 50 0, 5 LEGEND: AIR FLOW POWER SUPPLY AND ELECTRICAL PANEL WATER INLET WATER OUTLET Note: All models have 4 drills (8 mm diameter) for antivibratory - supports AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.65 A - N 6405 P 7

MAXIMUM SERVICE PRESSURE (Bar) - ITB SERIES COOLING CIRCUIT HYDRAULIC CIRCUIT WATER EXCHANGER 9 0 AIR COIL 9 OPERATION WITH GLYCOL WATER CORRECTION COEFFICIENTS POSITIVE RATE NEGATIVE RATE Cooling capacity E 0,98 According to capacities table EVAPORATOR Chilled water flow E,05, Water pressure drop E,5, Medium rate º C / 7 See graphic Heating capacity E 0,97 CONDENSER Hot water flow E,05 Water pressure drop E,0 Medium rate º C 5 / 40 Anti-frost protection with glycol water: Freezing point C oncentration % 0 0 0 0 40 Etylen-glicol Propylen-glicol º C 0 -, 8-8, -4, 5 -, º C 0 -, 7-6, 5 -, 4-0, 0 OPERATING LIMITS T. (allowance difference water I/O in ºC) 9 8 7 6 5 4-5 - 0 4 6 8 0 4 Water outlet T. in ºC Max. T Min. T For a water outlet T of +5ºC: T minimum:,ºc Water T rate: 8,ºC / 5ºC T maximum: 6,ºC Water T rate:,ºc / 5ºC For T differences not included between the curves: consult. 8 AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.65 A - N 6405 P