SimpleVIS Viscometer Reference Guide P

Similar documents
HI COD REACTOR and Test Tube Heater 2008 Series

Package Contents. Dry Block Heater Power Cord Instruction manual Warranty Card. Serial Number: Date of Purchase: Supplier: Table of Contents

Reacti-Therm I and III Heating Modules

USER MANUAL WATER DISPENSER WITH ICE MAKER

L1L2L3. 99 Washington Street Melrose, MA Phone Toll Free Visit us at

APPENDIX 4. Thank you for choosing the Biomega BioClave steam sterilizer. HYDRAULIC DRAWING

Tank, Heater, and Control Operation Manual REV. E DATE: 04May2015

MODEL 7000 SUCTION UNIT

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

Menumaster. Commercial Microwave Oven Use and Care Manual FS-8EVP FS-11EVP FS-16EVP

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

BD Viper Lysing Heater Manual (for BD Viper System)

PKWK43. Electric Thermo Pot

I N S T R U C T I O N S

Refrigerated Incubator Model and Operating Instructions

Menumaster. Commercial Microwave Oven Use and Care Manual CFSP70 GSAND-7D SAND-7D SAND-700

OPERATING INSTRUCTIONS FOR LEEC AUTOMATIC CO2 INCUBATORS. MODELS GA2000 and GA2010 MODELS GA3000 and GA3010 With Infrared CO2 detectors CONTENTS

SW-2 SNOW MACHINE. Item ref: UK User Manual

Operating Manual for. Ultrawash Plus. Absorbance. Plate Washing. Luminescence. Automated Processing. Software

GigaCore RPSU. Redundant power supply for GigaCore 14R and 16Xt. Quick Start Guide. V2.0.0 Rev1. English

Spy model 673 wet sponge holiday detector ope rati ng instructions

High Output Vacuum/Pressure Pump

Operating Instructions

KHM800 Professional 800w haze machine

I N ST. MODEL 2912PS AUTOMATIC SLICER... with Portion Scale 701 S. RIDGE AVENUE TROY, OHIO

QTFX-LF900 Low-Level Fog Machine User Manual

PRE INSTALLATION PROCEDURES

OIL COOLER INSTRUCTION HANDBOOK

MC2000 OPERATING AND CALIBRATION INSTRUCTIONS

Oil and Water Retort Instruction Manual

4-GALLON MOBILE PARTS WASHER

PRO 2000i LOW LEVEL DEPOSITOR

CONGRATULATIONS ON CHOOSING THE WATERLOGIC 4 FIREWALL YOUR WATERLOGIC WATER DISPENSER

USER S MANUAL. MODEL NO. CLTL100 (White) CLTL120 (Black) Top-Load Water Cooler

Cascade Comfort Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Water Boilers ME10EN, ME15EN. Table of Contents

User Manual AIR HOG. Vacuum Booster REV. 3/20/ Stowe Dr. Poway, CA P: (858) F: (858)

Reacti-Therm I and III Heating/Stirring Modules

Operator s Manual. Histology Bath

OPERATIONS MANUAL. Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS Certified

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL

Model # VWK-2 INSTRUCTION MANUAL

ASPIRE Laboratory Aspirator

LABORATORY ILLUMINATED FLOTATION BATH

WA A Aqua Sub Bottom-load Water Cooler

LABORATORY OVENS MODELS INCLUDE: TO-152G & TOH-152G TO-152F & TO-235F DEHYDRATING OVENS MODELS INCLUDE: TD-150F TD-330F TD-500F

Variable Temperature Digital Solder and Desolder Station

Product waste disposal - Protection of the environment:

Fisher Scientific Isotemp Muffle Furnace 550 Series. Instruction Manual

HP 101A Series Humidity Temperature Probes INSTRUCTION MANUAL

MP 601A Humidity Probe INSTRUCTION MANUAL

Z-350 Fazer Machine User Manual English

EDR Series. Model. Instruction Manual. Rev 5.0. Thank you for purchasing the EDR Auto Smart.

USER MANUAL AND TECHNICAL MANUAL

USER- MANUAL TV7000MKII

DC200 Digital Dispenser Operating Manual

Digital Heat Block User Manual

Shaking Hot Tubs. Orbital / Reciprocating Shaking Water Bath Liter 115V S 28 Liter 115V Liter 230V

THANK YOU. For purchasing the VMI HYBRID TM

Page 2 of 5. SOP SF SOP for Water Bath Maintenance

USER S MANUAL HSC-14/18/24/24A

Grafisk Maskinfabrik A/S Bregnerødvej 92, DK-3460 Birkerød, Denmark. Website: Phone:

B 353 COFFEE BREWING MACHINES MACHINES A CAFE KAFFEEBRUEHMASCHINEN KOFFIEZETAPPARATEN

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

One-Touch Dispense. Multi-temp selections. 208 F For tea, coffee, instant noodle. 194 F Keep warm around 194 F. 176 F Keep warm around 176 F.

60 Liter Infinity Storage Reservoir

Disposal Unit (BKSDU) Burger King Shortening. Operation, Service & Parts Manual BURGER KING BKSDU

Requests for Daily Care and Maintenance

QIAcube HT Unpacking and Installation Instructions

Instruction Manual Analog Vortex Mixer with Fixed Cup Head

ICE MAKER. Model: IM-101 INSTRUCTION MANUAL

A few simple steps to ensure perfect water, every time.

Notices. Safety Notices. 2 Restek Corporation

Pasto Sous vide water bath

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

REFRIGERATED BATH CIRCULATOR. Instruction Manual. Covers model : LRBC-13C / LRBC-22C. Please read this manual carefully before using the instrument

Manual v1 Page 1 of 19. Manual. Laboratory autoclave

SERRES SUCTION BAG SYSTEM MANUAL

SAVE THESE INSTRUCTIONS HOUSEHOLD USE ONLY

VISUAL DISPLAY DISPENSER OWNERS MANUAL

FD 430 Envelope Sealer

STORM. Bottom-Load. Water Dispenser User Manual

Schuco byallied MEDICAL ASPIRATOR. USER'S MANUAL A Caution

SAFETY PERSONAL AC VOLTAGE (50 or 60Hz) PROXIMITY DETECTOR

STEAM LITE S3251UKJR OWNER S GUIDE

NEW Restek Electronic Leak Detector

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

VAC-THEN-STEAM MV2010UKL OWNER S GUIDE

MW402 Integrated Dishwasher

GigaCore 12. Gigabit Ethernet Switch for the entertainment industry. Quick Start Guide. V2.1.0 Rev5. English

QTFX-900 mkii Fog Machine. Item ref: UK User Manual

Free Standing Water Cooler

Recirculating Chiller RC350G-RC400G RC1400G-RC3000G. Operating Manual

Corning LSE 6L Digital Water Bath

Black Body Calibration Source User Manual

Owner & Operator s Manual. Table of Contents

EN Variable Temperature Electric Kettle

Aluminum Heating Mantles

Oakton TEMP 9500 Advanced Multiparameter Controller

Transcription:

SimpleVIS Viscometer Reference Guide P82.0090

Run Status Indicator Lamps Sample/Solvent Port Waste Bottle Dust Cover Temperature Calibration Port Touch Screen Display RS-232 Serial Port Exhaust Muffler Vacuum Line Waste Line Power Connector

SAFETY CAUTIONS Please observe the following safety procedures and notices for proper operation of the SimpleVIS Viscometer. Make sure that you read and understand all operating instructions and safety precautions listed in this manual before installing or operating your unit. If you have questions regarding instrument operation or documentation, contact CANNON Instrument Company. Do not deviate from the installation, operation or maintenance procedures described in this guide. Improper use of the SimpleVIS Viscometer may result in a hazardous situation and may void the manufacturer s warranty. Handle and transport the unit with care. Sudden jolts or impacts may cause damage to components. Do not place the SimpleVIS Viscometer on an unstable cart or stand. The SimpleVIS Viscometer should be placed on a level table or bench. Never operate damaged or leaking equipment. Unless procedures specify otherwise, always turn off the unit and disconnect the mains cable from the power source before performing service or maintenance procedures, or before moving the unit. Never operate the equipment with damaged mains power cables. Refer all service and repairs to CANNON Authorized Service Personnel. CAUTION In addition to the cautionary statements listed above, additional cautions may be posted in the manual. These cautions, identified by the symbol at the left indicate important operational procedures. Read and follow these important instructions. Protective Conductor The Protective Conductor Terminal symbol is used to indicate required ground connections for your instrument electrical supply. WARNING When supplying power to this instrument, ensure that the protective ground (earth) terminals of the instrument are connected to the protective conductor of the (supplied) line (MAINS) power cord. Use only the manufacturer-supplied power cord. The main plug for the power cord should only be inserted in a socket outlet (receptacle) provided with a protective ground (earth) contact. Do not use an extension cord (power cable) without a protective conductor (grounding). 3

~MAINS The ~MAINS symbol indicates instructions or connections for the AC power supply. The AC Power input must match the electrical specifications listed on the label on the rear panel of the instrument. The supplied AC Mains power cord must be attached to the connector labeled ~MAINS. This connection serves as a means of disconnect and should be readily accessible. ( O ) The (O) symbol indicates the OFF position for the electrical switches for your unit (AC Mains or accessories). Hazardous materials Routine SimpleVIS Viscometer operation may require the use and handling of hazardous chemicals and solutions. CANNON Instrument Company strongly urges the operators and technicians working with the SimpleVIS Viscometer to take proper safety precautions when working with these materials. These safety procedures can be found in the Material Safety Data Sheets which accompany the solutions. 4 SimpleVIS Viscometer Specifications/Compliance Product Info. Model: SimpleVIS Viscometer (Cat. No. 9725-S10) Applications ISO VG Lubricants, SAE Engine and Gear Oils Methodology Kinematic Viscosity, ASTM D7279 or ASTM D445-Modified Test Temperatures 40 or 100 C - user selectable Viscosity Range 40 C: 10 700 mm 2 /s (cst) 100 C: 5.5 200 mm 2 /s (cst) Accuracy < 3% of measured value, calibrated Repeatability < 2% of measured value, typical Sample Material Type Mineral Oils, Synthetic Oils, Formulated Motor/Gear Oils Solvent Compatibility Internal wetted components compatible with n-heptane only Volume Requirements Sample: 450 500 μl Solvent: 10 15 ml per test Dimensions 128 mm wide x 356 mm deep x 304 mm high (5x14x12 ) Weight SimpleVIS Viscometer unit: 4.6 kg (10.2 lbs) Shipping Weight 12.3 kg (27 lbs) with all accessories Input Power SimpleVIS Viscometer Operation Voltage: 11 13 VDC @ 5A peak AC/DC Adapter 100~230 Volts, 50/60 Hz, 100 Watts Power Requirements Operating Conditions 15-30 C, 10%-90% R.H. non-condensing, Installation Category II, Pollution degree 2 Compliance CE Mark: EMC Directive (2004/108/EC); Low Voltage Directive (2006/95/EC); HI-POT (1900 VDC, 60 sec.); ROHS

Running a Test GETTING STARTED Press the on switch on the AC/DC adapter. The Warm up Screen will display a PLEASE WAIT message. During this time, the instrument will seek the preset target temperature (40 or 100 C) and when reached, the instrument will enter an equilibration period. The equilibration period is 180 seconds. Note: Refer to the Basic Information section under Select Target Temperature for instructions on how to select the target temperature. Warm up Screen Once the temperature has equilibrated and the instrument is ready for measurement, the run status indicator lamps on front of instrument will illuminate and the user will be prompted to inject the sample on the Ready to Test Screen. Check the volume of the solvent container at the beginning of every work shift to avoid inadequate washing during testing. Ready to Test Screen Check the volume of the Waste Bottle frequently to avoid spillage/overflow. Empty the waste bottle when the volume reaches the 400 ml line marked on the bottle. Refer to the Basic Maintenance portion of this guide for more information. 5

Running a Test Injecting a sample 1. Using the supplied piston operated pipettor, insert the tip into a vial of test sample and pull the measured amount into the pipettor. Be sure no bubbles exist in the oil or results may be erratic. Refer to pipettor instruction guide for more information. The pipettor volume setting should be set to 450 ~ 500 μl (0.45-0.50mL) 2. Place the pipettor at a 45 angle into the sample/ solvent injection port, located on top of the instrument, and gently release the fluid in one easy operation so that the entire sample is smoothly dispensed into the tube without introducing bubbles. The Ready to Test Screen contains a START button. Pressing the button is optional as the injected sample will automatically be detected. The button is useful for higher viscosity fluids that might take a while to trip the top sensor. The run status indicator lamp will turn off during testing. When the viscosity measurement is complete, the run status indicator lamp will blink and the viscosity result will be displayed. 6

Running a Test Print the results (only if optional printer is installed) 1. Press the Print button on the display screen to printout the test results to an attached serial printer (optional accessory). 2. You may skip the print option and go directly to the wash cycle. See the next section. Wash Cycle Result Screen 1. Place the tip of the solvent bottle along the opening of the glass capillary in the sample/solvent port and gently squeeze until the cup is filled with solvent to clean any oil residue that might be left over from injecting the previous sample. Be careful to consider bath temperature (s) and potential solvent hazards when selecting solvents for use with the SimpleVIS Viscometer. Observe appropriate safety precautions when handling solvents. Note: Heptane (technical grade) is compatible with the SimpleVIS Viscometer. 2. Press the Wash button on the display screen to start the wash cycle. 3. Wait for the solvent in the cup to be drawn down the tube. 4. Place the tip of the solvent bottle directly into the glass capillary for approximately one second (no need to squeeze the bottle, the pump will pull the solvent in) and then remove for several seconds to allow the solvent to be drawn through the viscometer tube to the waste bottle. The display screen will prompt the user when to inject and remove the solvent bottle. Repeat this step until the display screen alerts the user to press the Dry button to start the dry run cycle. 7

Running a Test Dry Cycle Press the Dry button on the display wash screen to start the dry run cycle. The display will show the time remaining in the dry cycle. When the dry cycle time ends, the pump will turn off and the instrument will return to the Warm up Screen for a period of 60 seconds. The instrument will then be ready to run a new sample measurement at the leisure of the operator. Run Status Indicator Run Status Indicator lamps on front of the instrument allow users to see from a distance whether the instrument is ready to accept a sample. When the instrument is ready to accept a sample, the lamps will be lit. During the viscosity measurement, the indicator lamps will be off. The indicator lamps will blink at the conclusion of a new test or if an instrument error occurs. Wash Screen Dry Screen 8

Maintenance & Calibration The SimpleVIS Viscometer was designed to require minimal maintenance through simplicity of design and built-in electronic diagnostics. All new instruments are shipped with factory calibrations. However, like most metrological equipment, periodic maintenance and calibration is critical to maintaining accurate long-term measurements. CANNON Instrument Company recommends the following intervals for maintaining the proper and accurate operation of the SimpleVIS Viscometer. Basic Maintenance The main chassis of the SimpleVIS Viscometer does not contain any user-serviceable parts and should be returned to the manufacturer (or an authorized dealer service center) for repair when required. Basic instrument maintenance should be carried out weekly or each time the effluent waste bottle is emptied. Cleaning the Viscometer Tube To clean the viscometer tube simply start a wash cycle by tapping the Ready to Test caption field in the Ready to Test Screen three times within two seconds. This will cause the display to switch to the Wash Screen and start a normal wash. See discretionary washing on page 12. Changing the Tip on the Pipettor Refer to the pipette manual for detailed information on using the device. The tips can be wiped off after each test and reused. Use a clean dry paper towel to wipe the tip off. Cleaning the Display Screen Turn off the SimpleVIS Viscometer. Wet a soft, lint-free or micro fiber cloth with clean or distilled water. Wring out as much water as possible to ensure the cloth is damp but not wet. Wipe the screen in a gentle motion to remove dust, oil, or fingerprint smudges. Finish cleaning the touch screen with a dry lint-free cloth to wipe any excess moisture, and then turn the instrument back on. 9

Maintenance & Calibration Emptying the Waste Bottle Receiver Check the volume of the Waste Bottle frequently to avoid spillage/overflow. Disconnect the Waste Bottle from the cap containing the drain lines. Use appropriate precautions when handling the waste lines. Avoid spilling or splashing waste material collected in the lines. Check for kinks or wear in the lines. Always follow appropriate MSDS procedures when handling samples/solvents. Pour the collected solvent/sample mixture out of the Waste Bottle into a proper hazardous liquid waste storage container. Securely reconnect the cap with drain tubes to the Waste Bottle ensuring the lines are properly inserted. (Refer to the Basic Information section of this guide for more information on tubing connection) Waste sample/solvents can present possible environmental and health hazards. Dispose of all waste materials in accordance with all applicable governmental environmental and safety regulations. Cleaning the Tray that Houses the Waste Receiver Use a clean dry paper towel to wipe the tray to remove any spillage of solvent/sample. Dispose of the paper towel appropriately. Changing Temperature Change the temperature by tapping the temperature directly under the Seeking Target Temperature caption field in the Warm Up Screen three times within two seconds. Calibration The frequency of instrument calibration is dependent on the usage of the instrument (number of samples tested monthly), the environment in which the instrument is located, the type and cleanliness of the samples, and whether basic maintenance has been properly carried out. CANNON recommends 10

Maintenance & Calibration either of the two following calibration intervals. Performance Based Method Determine need to calibrate by performing weekly check-runs of certified viscosity reference standards. It is recommended the results of these runs be recorded and compared against the certified viscosity value printed on the standard bottle. When these check-runs consistently exceed the required precision (typically > 2 or 3%), then the instrument should be calibrated. This method requires more user interaction, but affords the least amount of risk that the instrument could be used when out-of-calibration. Periodic Interval Method On a 12-month basis, the instrument is returned to CANNON Instrument Company for calibration and certification regardless of the prior usage and performance. This method requires the least amount of user interaction with the instrument, but does afford some risk as errant calibrations (if present) will only be corrected once every 12 months. Verifying Temperature Periodically, the temperature should be verified with a digital reference thermometer. The temperature should be recalibrated if the displayed temperature does not agree with the reference thermometer. Note: Please contact CANNON Instrument Company for details on suitable reference thermometers. The user may access Temperature Calibration Screen from the Ready to Test Screen by tapping the temperature field 3 times within 2 seconds. The Temperature Calibration Screen Temperature Calibration Screen will appear in which the user may enter the temperature as read from the reference thermometer to the nearest 0.01 C. This may need to be repeated if the temperature still does not agree 11

Maintenance & Calibration with the reference with the desired tolerance. Changing the temperature calibration by more than 0.05 C will affect the instrument viscosity calibration by 2% or more. Please consult CANNON before proceeding. It is recommended that the instrument temperature be at target for at least 30 minutes before recalibrating if the instrument has been powered down for more than a couple of hours. This will ensure proper calibration as it may take some time for the entire instrument to come to proper thermal equilibration from a cold start. Changing Date and Time End users may need to change the date and time displayed on the instrument. This may be accomplished by just tapping once on the Date/Time field at the bottom of the Warm up Screen or the Ready to Test Screen. These fields are soft buttons which will access Date and Time Screen. This screen provides list boxes to set the Year, Month, Day of Month, Hour and Minute. Date and Time Screen Discretionary Washing Tube washing is normally performed after a test is completed, but there may be other times when the tube needs washing. For example, if the user injects oil into the tube and the sensors do not detect it for some reason. In cases such as this, the wash cycle may be started by tapping the Please Wait caption field in the Warm up Screen or the Ready to Test caption field in Ready to Test Screen or the Timing Started caption field in Timing Screen three times within 2 seconds. This will Timing Screen cause the display to switch to Wash Screen 12 and start a normal wash cycle.

Basic Information Unpack your SimpleVIS Viscometer Remove all packing materials from the components. The SimpleVIS Viscometer should be placed on a stable laboratory table or bench. 1. Verify that you have received all components for the SimpleVIS Viscometer. Report missing items to CANNON Instrument Company immediately. 2. Inspect each component for signs of damage. Report damages to the shipper and CANNON Instrument Company immediately. 3. Retain all packing materials until the instrument is connected and functioning properly. If any component(s) must be returned to CANNON Instrument Company, the damaged item(s) should be packaged in the included shipping case. Setting up your SimpleVIS Viscometer Complete the following rear panel electrical connections: 1. Plug the AC/DC power adapter into the power connector on the rear panel of the instrument. The connector will only go in one way correctly. Make sure the power switch on the AC/DC adapter is off. 2. Plug the power cord into the AC/DC adapter. Plug the other end of the power cord into an appropriate AC Mains outlet matching the voltage requirements indicated on the AC/DC adapter. 3. Do not turn on the AC/DC adapter switch at this time. (Optional printer: Plug the 9 pin serial printer cable into the RS232-C port on the rear panel of the instrument. Then plug the other end into the printer.) Complete the following tubing connections: 1. Locate the glass waste bottle and securely (but not overly) tighten the bottle cap to ensure an air-tight seal. Place the bottle in the holder on the top rear of the SimpleVIS Viscometer. 2. Connect both pieces of the1/8 transparent tubing into the bottle cap. 3. Make sure that the waste line extends into the cap further than the 13

14 Basic Information vacuum line by approximately 2 inches. 4. Connect the other ends of both pieces of tubing as indicated in the photo image. Select Target Temperature 1. Press the on switch on the AC/DC adapter. The Warm up Screen will display a PLEASE WAIT message 2. Select the temperature by tapping the temperature directly under the Seeking Target Temperature caption field in the Warm Up Screen three times within two seconds. This will cause the display to switch to the Set Temperature Screen. 3. Select the desired temperature then press the save button. Returning your instrument to Cannon Instrument Co. 1. Please contact CANNON Instrument Company to receive a Return Authorization (RA) number from our Technical Service Department. 2. Download our Instrument Repair/Calibration Return Form and fill in all required information on the form 3. Carefully package and ship your instrument with all required information in the case supplied with the instrument. The RA number needs to be clearly marked on the package label. Ship to the following address: Cannon Instrument Company ATTN: Return Authorization Number: 2139 High Tech Road State College, PA 16803 USA When returning your instrument please include the following information: The name and telephone number of the person in your company to contact regarding the instrument.

Components for the SimpleVIS Viscometer 9725-S10 Waste Bottle Media Cap P82.0075 1/8 Transparent Plug Tubing P65.3203 P81.2185 Waste Bottle P82.0075 Pipette Seals, pkg. of 8 (optional) P82.0056 Printer Cable (optional) P82.0065 Printer Power Supply (optional) Printer with Power Supply (optional) P82.0076 Pipettor P82.0055 Solvent Container P82.0053 AC/DC Adapter P82.0028 Power Supply Cord P74.2110 (120V) Pipette Tips (optional) P82.0054 15

2139 High Tech Road State College PA 16803 814-353-8000 800-676-6232 Fax 814-353-8007 cannon@cannoninstrument.com www.cannoninstrument.com simplevismanual.indd 07.09.12