PATIENT MONITORING SYSTEMS

Similar documents
PATIENT MONITORING SYSTEMS

PATIENT MONITORING SYSTEMS

1 Appendix - Product Specifications

OMNI TOUCH SCREEN PATIENT MONITOR

DPM Summary of Features and Benefits

Omni (K) PATIENT MONITOR

PM-9000 Express Portable Patient Monitor

DPM4 Bedside Monitor Default Settings

Multi-Parameter Patient Monitor

Product Specifications

5/ 5i/ 5c/ 7/ 7i/ 7c/ 5 elite/ 5i elite/ 5c elite/ 7 elite/ 7i elite/ 7c elite

CLEO VERSATILITY IN VITAL SIGNS

Vitalmax 4000 CL Product Specifications

OMNI Express VS VERSATILITY IN VITAL SIGNS

MRI Patient Monitoring System (Model )

T1 Monitor/Module Default Settings

www. szcomen. com COMEN - SHARE WITH THE WORLD

Infinity M300 Patient Worn Monitoring

B40 Patient Monitor. Affordable clinical excellence. Advanced clinical parameters. Ease of use for fast decision-making. Performance and reliability

SPECIFICATION FOR MULTIPARAMETER MONITOR

Meditec M700 Series Patient Monitors

GE Healthcare. Dash Variable-Acuity Monitoring

T1 BEDSIDE MONITOR GUIDELINE

M8000VET /M9000VET Veterinary Monitor User s Manual

User s Guide. Cardell Touch Veterinary Vital Signs Monitor. For Models:

Infinity M300+ Telemetry

Instructions for Use Vista 120

qube mini Overview

SECTION L MONITORING EQUIPMENT

Alarm and Measurement Default Settings

Menntor X7 Specification

Passport 12m and Passport 17m BEDSIDE MONITOR GUIDELINE 5.21 Software Version NAME: HOSPITAL: DATE: VALIDATOR: Performed

L505. Patient monitor user manual. Technology that doesn t miss a beat. Tel:

Patient Monitor CM400PC Monitoring Module

Ultraview SL2400 With Wireless-LAN-Option

İndex SUCTION UNIT... PATIENT MONITOR HOLTER SYSTEM... 7

Veterinary Portable Multi-parameter Patient Monitor. Operation Manual

Multiparameter. er Monitor DM

Measurements to guide your patient care

General Skills. yes. Device controls, buttons, indicators, and connectors

Instructions for Use. Infinity Vista. Infinity Patient Monitoring Series

M9500 Patient Monitor User s Manual

SERVICE MANUAL YM6000 Patient Monitor

GE Healthcare. Quick Guide. Dash 2500 Patient Monitor

QAM.L L550 series. Patient Monitor Manual QAM.L

Patient Alarm Messages

June 17, Skanray Technologies Pvt Ltd. c/o Ms. Yolanda Smith Regulatory Consultant Smith Associates 1468 Harwell Avenue Crofton, Maryland 21114

PAT I E N T M O N I TO R I N G N E T W O R K

HeartStart XL+ Configuration Worksheet

SureSigns VS4. Vital Signs Monitor Technical Data Sheet

Patient Monitoring System YM5500. Service Manual

Propaq LT Outline Train the Trainer

BM3VET User Manual Code Veterinary Monitor Rev. 2.4

Atlas Monitor Outline Train the Trainer

PM-9000Vet Veterinary Portable Multi-Parameter Patient Monitor. Operator s Manual

Ultraview SL Command Module Parameter Set ECG NIBP TEMP IP CO SpO2 Options SL Command Module: A B Our goals are simple:

SAINT JAMES HOSPITAL GROUP PURCHASING DEPARTMENT

Capnostream 20p Bedside Capnography Monitor. The only integrated, complete picture of oxygenation and ventilation 1

Manufacturer s Responsibility Only under the following circumstances will manufacturer be responsible for the safety, reliability and performance of t

SERVICE MANUAL. Patient Monitor M30. EU representative TECNOMED 2000 S.L. Valencia, Madrid Spain

Central Monitor. Central Monitoring System. Intuitive, Reliable, Flexible CNS-9601K. Shown with options

Clinical Information Center Pro v5 (CIC Pro)

Cost-effective way to tailor anesthesia

Operating Instructions. Passport _PPV ops color.indd 1

OPERATOR S MANUAL. Patient Monitor M20. EU representative TECNOMED 2000 S.L. Valencia, Madrid Spain

End-Tidal CO2 User Guide CAPNO3 T NIBP. SpO2. Ver Charmcare Co., Ltd.

SECTION L MONITORING EQUIPMENT

MRI Monitor. All-in-one monitor for the MRI environment. Features. Parameters. Accessories

ncompass 8100H Series Vital Signs Monitor Operator s Manual

Transport Pro Patient Monitor Operator s Manual Software Version 2.1

Nellcor with OxiMax Technology Product Ordering Guide A Full Line of Oximetry Sensors and Monitors

OMNI. Patient Monitor USER S MANUAL

DPM 4 Patient Monitor. Operator s Manual

Central Monitor CNS Shown with options

OKM 801INFANT INCUBATOR

Multi-parameter Patient Monitor STAR8000H. User Manual

VS2000V Veterinary Vital Signs Monitor Operation Manual

INSTRUCTIONS FOR USE. IntelliVue X2. Multi-Measurement Module Release G.0 with Software Revision G.0x.xx. Patient Monitoring

The information in this document is subject to change without notice.

OPERATOR S MANUAL. NPB-4000/4000C Patient Monitor

Menntor X7 SERVICE MANUAL. Modular Patient Monitors FDM

HBP Patient Monitor. Operator s Manual. EU representative OBELIS S.A Bd. Général Wahis, Brussels, Belgium.

TPCA TM PATIENT CONTROLLED ANALGESIA SYRINGE PUMP

INSTRUCTIONS FOR USE. IntelliVue Patient Monitor. MP5 Release G.0 with Software Revision G.0x.xx. Patient Monitoring

PM Portable Multi-parameter Patient Monitor. Operation Manual

B40/B20 Patient Monitor User's Guide. English E (Paper) 21 November General Electric Company. All rights reserved.

Nellcor Bedside SpO 2 Patient Monitoring System, PM100N

740 SELECT. Multi-Parameter Monitor

ARGUS VCM Vital Compact Monitor

T1 Patient Monitor. Operator s Manual

BeneVision Central Monitoring System. Quick Reference Guide

OPERATOR S MANUAL. For YM1000 Vital Signs Monitor. EU Representative TECNOMED 2000 S.L. Valencia, Madrid Spain

Infinity M540 Patient Monitor

Vital Signs Monitor 300 Series

Checkout Procedure Manual

cpm 12/cPM 8 Patient Monitor Operator s Manual

User Guide. Cardell Insight Veterinary Monitor. For Models: 8014 Blood Pressure Blood Pressure, Pulse Oximetry

D Moving beyond telemetry INFINITY M300

THE CLINICAL CONNECTION

MEDUCORE Standard 2. Defibrillation, Monitoring and Ventilation in One Hand NEW

Transcription:

PATIENT MONITORING SYSTEMS

Patient Monitoring Systems DESIGN FEATURES HEYER VizOR is our premium solution for sophisticated patient monitoring applications. VizOR comes in its standard configuration with a wide range of functions & features and makes it fit to match the requirements of high-sophisticated applications in OR, ICU and sickroom. Integrated high-quality modules (e.g. Masimo SpO2) ensure an accurate and stable measurement of the different parameters and a maximum safety for patient and doctor. The Patient Monitoring System HEYER VizOR can also be combined with various Anesthesia Machines to create a complete and fully functional Anesthesia Workstation. By using Masimo PhaseIn, Side & Main Stream Multi Gas Technology the VizOR can be completed as a supervisor for the total gas exchange of the patient. A wide range of screen sizes from 5 to 18.5 meet the individual situations of the hospital demand from transport to intensive care. VizOR 6 Heyer VizOR 6 is a cost-effective and lightweight (5 display, weighting < 800gr) detachable patient monitor that integrates of the most advanced non-invasive patient monitoring capabilities available today. It can be used for bedside monitoring and as a transport vital signs monitor throughout the entire care path. The compact VizOR 6 monitor easily slides into various docking stations and includes network connectivity, VGA output, a recorder, and an extra battery. HEYER VizOR 6 ensures the same functionality as a full-size multi-parameter monitor making it ideal for acute and general care floors, clinics, and home health care settings. The VizOR 6 can also be used in combination with defibrillators, ventilators and anesthesia machines providing complete vital signs and core patient monitoring parameters in a variety of clinical settings. Small and lightweight design concept A complete solution for all patient monitoring settings 5 color TFT display screen ECG (3/5 Lead), HR, SpO2 Masimo SET, RESP, NIBP (CAS/Standard), 2 TEMP, IBP, Gas interface for CO2 2 hours rechargeable battery (exchangeable by user) Touch Screen and Direct Access Keys 96 hours trend VizOR 6 options CO2 (Main Stream & Side Stream) Masimo Rainbow SET Wireless LAN Networking for Central System Cardiac Output (coming soon)

VizOR12s

VizOR 10 The compact and reliable monitor Portable color monitor with full parameters High performance monitoring in all areas of hospital Light & compact design concept 10 TFT color display with 6 traces Adult/neonatal applications Multi-Parameter: ECG, HR, RESP., SPO2, NIBP, 2 IBP, 2 TEMP CO2 and Multi Gas Analyzer (optional) Thermal Recorder (optional) Direct AC power & internal rechargeable battery for use in everywhere Rotary switch and dedicated direct access keys for intuitive & simple operation VizOR 12 Multifunctional patient monitor Reliable monitoring in all areas of hospital Light & compact design concept 12.1 TFT color display with 6 to 8 Signal traces Adult/neonatal applications Multi-parameter: ECG, HR, RESP, SPO2, NIBP, 2 IBP, 2 TEMP CO2 and Multi Gas Analyzer (optional) BFA - Brain Function Assessment (optional) Thermal Recorder (optional) Direct AC power & internal rechargeable battery for use in everywhere Rotary switch and dedicated direct access keys for intuitive & simple operation Networking with VizOR Central Monitoring System VizOR 12 Multifunctional patient monitor High performance multi parameter monitoring Complete solution for patient monitoring with 12 parameters ECG, HR, SPO2 Masimo SET, RESP, NIBP, 2 TEMP, 2 IBP Arrhythmia & ST Segment Analyzer 12 TFT Color bedside monitor with optional touchscreen Internal rechargeable battery Ethernet LAN networking Options: Masimo Rainbow SET Multi Gas Analyzer 12 Leads ECG Cardiac output BFA - Brain Function Assessment Wireless LAN Networking VizOR 15 Multifunctional patient monitor Contemporary design and concept 15 TFT color bedside patient monitor 6 to 8 signal traces and up to 10 Parameters: ECG, SPO2 (Masimo), RESP, NIBP, 2 TEMP, 2 IBP, CO2 (optional) ARR & ST Segment Analyzer CO2 and Multi Gas Analyzer (optional) Cardiac output (optional) BFA - Brain Function Assessment (optional) Direct AC Power, DC Power & internal rechargeable battery for use in everywhere Networking with VizOR Central Monitoring System Thermal recorder with 2 traces (optional) VizOR 17 Multifunctional patient monitor Multi Page Screen 18.5 TFT wide screen color LED display 6 to 12 Signal traces and up to 10 parameters: HR, NIBP (CAS/ Standard). RESP, IBP (up to 4), ECG, SPO2 Masimo SET, 2 TEMP, Gas Interface ARR & ST Segment analyzer Direct AC power, DC power & internal rechargeable battery Networking with VizOR Central Monitoring System Options: Masimo Rainbow SET CO2 & Multigas analyzer (main stream & side stream) BFA - Brain Function Assessment Cardiac Output 12 Lead ECG 2 Traces Thermal Recorder Wireless communication Touch screen Dual version hosting VizOR 6 as a module ICP 4 IBP connection Central Station Central Monitoring System for HEYER VizOR Patient Monitoring Systems Optional dual-screen display, color TFT LCD screen with high-resolution Up to 64 real time waveforms for up to 32 beds simultaneously ECG (I, II, III, avr, avl, AVF, V), SpO2, RESP, CO2, Dual IBP waveforms Selective waveforms and parameters Various configurations of main screen Convenient operation with touch-screen or mouse Supporting LAN network Audible and visual alarms Up to 96 hours trend store and review Up to 720 alarm events store and review Up to 1000 NIBP measurements store and review Up to 48 hours of disclosure store and review Set up the color of waveforms/parameters Exchanging the position of patient window Supporting thermal recorder, optional external laser printer Data Backup Managing patient information

Specifications General Specifications Safety Usage Harmful liquid proof degree Protection AC power Internal battery DC power plug Dimensions (cm) Weight (kg) Display Color display Waveforms Sweep speed Numeric parameters Operation method Input / Output Network Connection Based on IEC 60601-1, Class I, Type CF for all modules (Except Multi-Gas & NIBP module = BF) Continuous Operation Equipment Ordinary equipment (without Liquid Proof) Against electro surgery and defibrillator 90 260 V AC, 50/60 Hz Sealed lead acid 12 V. 3.3 Ah. Rechargeable Lithium Polymer: 11.1 V, 4.5 Ah, rechargeable (option) charging time: 16h Usage with Sealed Lead Acid: VizOR 10 : more than 120 min (full charge) VizOR 12 : more than 120 min (full charge) VizOR 15 : more than 60 min (full charge) VizOR 17 : more than 100 min (full charge) Usage with Lithium Polymer: More than 3.5 hours 12 14 V, 3 A (6A with recorder) W x H x D VizOR 6 15 x 10.9 x 6.7 VizOR 10 26 x 29 x 19 VizOR 12 31 x 28 x 19 VizOR 15 42 x 36 x 17 VizOR 17 45 x 35 x 16 VizOR 6 Approx. less than 1 kg VizOR 10 Approx. 5.5 VizOR 12 Approx. 6 VizOR 15 Approx. 6 VizOR 17 Approx. 7 VizOR 6 5 TFT, 480x2722 flexible display Configuration VizOR 10 10.4 TFT, 800x600 6 Traces / 8 Parameter VizOR 12 12.1 TFT, 800x600 6 to 8 Traces / 10 Parameter VizOR 15 15 TFT, 1024x768 6 to 8 Traces / 10 parameter VizOR 17 18.5 TFT, 1366x768 6 to 12 Traces / 10 Parameter ECG, SpO2, RESP/Gas, IBP 1, IBP2, EEG, C.O. (freezable) 12.5, 25, 50 mm/sec HR, PVCs, ST, Pulse Rate, SPO2, SIBP (SYS, DIA, MAP), IBP, (SYS, DIA, MAP), RR, T1, T2, DT, AWRR, Alarm Limits, EtCO2, FiCO2, EtN2O, FiN2O, EtO2, FiO2, EtAA, FiAA, BFI%, BS%, EMG%, SQI%, C.O. Key, Rotary knob, Membrane Touch Screen for VizOR 12s (option), VizOR 17 (option) Digital, Serial, RS422, Full Duplex, TCPIP VizOR Central Station Recorder (option) Model General scanning / Thermal printing Printing speed 6. 12.5, 25, 50 mm/sec Paper 58 mm by 20 m roll Temperature Probe type YSI-400 compatible Range 0 50 C Accuracy ±0.2 C Respiration Method Impedance Base resistance 250 1250 Ohm RESP SWEEP Speed 3, 6, 12.5, 25 mm /s Dynamic range 0.2 2 Ohm Breath rate range 0-253 bpm Accuracy ±2% Alarm Sources Alarm on / off Lead fault alarm Alert Error messages, all other parameter limits Selectable for all parameter Auditory and visual Blinking on display, Volume selectable Audio Alarms, Light Indicator Trend Sources HR, PVCs, ST, AFIB, SpO2, RR, T1, T2, IBP1 (SYS, DIA, MAP),IBP2 (SYS, DIA, MAP), EtCO2, FiCO2, AWRR, EtO2, FiO2, EtN2O, FiN2O,EtAA,FiAA,C.O. Trend Time 15 min, 30 min, 45 min, 1, 2, 4, 8, 12, 16, 24, 36, 48, 60, 72, 96 hours Resolution 1 sec Arrhythmia Analysis (except VizOR 6) Type ASYS, VFIB, AFIB, VTAC, RUN, AIVR, COUPLET, BIGEMINY, TRIGEMINY, TACHY, BRADY, PAUS, FREQUENT PVCs Learning Rapid learning; only 20 sec required for recognition of dominant rhythm Method Real time Arrhythmia Detection with innovative feature Memory Capability of storing the latest 150 ARR events (waveform and parameter) ST Analysis (except VizOR 6) Display resolution 0.01 mv Measurement -2 mv to +2 mv range Alarm range -2 mv to +2 mv Features User adjustable Isoelectric and ST Point Trending of ST values Update period 5 sec SPO2 (Pulse Oximetry) Masimo SET Method 2 wave length pulse wave type SPO2 Measuring 0% to 100% Range SPO2 Alarm Range 50% - 100% SPO2 Accuracy 71% - 100% ± 2% 50% - 70% ± 3% Pulse rate range 25 250 bpm ECG Leads Selectable 3, 5 10 wires optional For 3 wire: I, II, III For 5 wire: I, II, III, V, avr, avf, avl For 10 wire: I, II, III, V, avr, avf, avl, C2, C3, C4, C5, C6 4 Traces / up to 7 Waveforms ±5 mv Waveforms Dynamic range Leakage current < 10µA Lead off current < 90 na Gain 4, 2, 1, 1/2, 1/4, auto Calibration 1 mv, 0.5 sec Filters MONITOR (0.5 24Hz) NORMAL (0.5 40 Hz) EXTENDED (0.05 100 Hz) CMRR Internal noise >98 db < 30 µv RTI

Input impedance QRS detection Heart rate range Tall T-wave Pace Detection / Rejection Protection Standards >5 MOhm Duration: 40 120 msec Amplitude: 0.25 5 mv for Adult/Pediatric 0.2 5 mv for Neonate 15 300 bpm Adult/Pediatric 15 350 bpm for Neonate Accuracy: ±1% for 2bpm Reject up to 1.2 mv Amp Duration: 0.1 2 msec Amp: ±2 to ±700 mv (without over / undershoot) Reject from heart rate counter Re-insert into ECG to display on screen Ineffective pace rejection HR: 0, Pace 60 / HR 60, Pace 60 / HR 30, Pace 80 Beside rejection of arterial paces preceded ventricular paces by 150 or 250 msec Defibrillator and electro surgery ANSI / AAMI EC-13 NIBP Measurement Oscillometric Method Measurement Manual / Automatic mode (intervals between 1 min 24 hours) / STAT Measurement time 20 25 sec (excluding cuff pressurizing time) Measurement Adult: range SYS 30 ~ 255 mmhg DIA 15 ~ 220 mmhg MAP 20 ~ 235 mmhg Neonate: SYS: 30 ~ 135 mmhg DIA 15 ~ 110 mmhg MAP 20 ~ 125 mmhg Pressure ± 3 mmhg full range transducer accuracy Initial inflation Adult 150 mmhg target Pediatric 140 mmhg Neonate 85 mmhg Overall system Meet ANSI/AAMI SP-10/2002 efficacy Memory Up to 500 records IBP Channel Measurement range Pressure sensor sensitivity Pressure sensor impedance Resolution Accuracy Alarm range Filters 2 Channels SYS -50 ~ 300 mmhg DIA -50 ~ 300 mmhg MAP -50 ~ 300 mmhg 5µv/v/mmHg 300 2500 Ohm 1 mmhg 2 % or 2mmHg (each one is greater) without Transducer -50 300 mmhg Adjustable 8, 16, 22 Hz Main-Stream Multi Gas (optional) IRMA CO2, AX+ Measuring parameters IRMA CO2 CO2, AWRR IRMA AX+ CO2, N2O, 5 anesthesia agent (HAL, ENF, ISO, DES, SEV Auto ID), AWRR Side-Stream Multi Gas (optional) ISA CO2, AX+, OR+ Measuring parameters ISA CO2 CO2, AWRR IS AX+ CO2, N2O, 5 anesthesia agent (HAL, ENF, ISO, DES, SEV Auto ID, AWRR) ISA OR+ CO2, N2O, O2 paramagnetic, 5 anesthesia agent (HAL, ENF, ISO, DES, SEV Auto ID), AWRR Oxygen Integrated ultra-fast response time galvanic oxygen Sensor Type sensor (>62500 oxygen hours) BFA - Brain Function Assessment (optional) Function Measure the direct effect of anesthesia and sedative drugs on brain Environmental Temperature Humidity Altitude Operating: 5 40 C (for Gas Module: 10 to 35 C) Storage: -20 to 50 C) 20 90% (non-condensing) -200 to 3000 m VizOR 6 Additional Specifications Application Small enough to carry, powerful enough to monitor patient anywhere Environmental Meeting rigorous environmental standards, IPX II, Vibration, Shock Protection EMC. Electrosurgery, Electroshock Power AC adapter, rechargeable Battery, user replaceable and 12-14V/DC ext. power supply (e.g. in ambulance) Battery Backup Up to 2 hours (full charged) - Ni-MH 3.6 V 2500 mah User interface Touch-Screen, Membrane IBP Up to 4 (coming soon) Drug Calculation (coming soon) OXYCRG (coming soon) VizOR 6 Options CO2 (Main Stream & Side Stream) Masimo Rainbow SET Thermal Recorder Wireless LAN Networking Cardiac Output (coming soon) 12 Lead ECG (coming soon) Various chargers / docking stations F1 Docking Station: Li-Ion 11.1 V 4300 mah, usage > 12 h, charging ~ 6 h F1R Docking Station: same like F1, with recorder VizOR 17 Options CO2 & Multi-Gas Analyzer (Main Stream & Side Stream) Possibility of hosting VizOR 6 as a complete module Brain Function Assessment (BFA) Masimo Rainbow SET Thermal Recorder with 2 Traces Drug Calculation Wireless Communication Cardiac Output 12 Lead ECG function 4 Channels IBP connection (transducer optional available) Touch Screen OXYCRG ICP Subject to changes without prior notice!

HEYER Medical AG Carl-Heyer-Str. 1/3 56130 Bad Ems Germany Tel. +49 2603 7913 Fax +49 2603 70424 info@heyermedical.de www.heyermedical.de Rev. 08/2017 - EN