icount Range Fluid Condition Monitoring Moisture Sensors An essential component of any predictive maintenance programme Fast, reliable and accurate inline detection of moisture in fluids moisture sensors provide fast, reliable and accurate inline detection of moisture in fluids. Technology developed for preventative maintenance programmes. is the low pressure option for suction line/reservoir applications. is the Programmable sensor monitoring and reporting relative humidity (RH), moisture content in oils. Intrinsically safe sensor ATEX certified for use in hazardous Zone environments. Contact Information: European Product Information Centre Freephone: 8 7 7 7 (from AT, BE, CH, CZ, DE, EE, ES, FI, FR, IE, IT, PT, SE, SK, UK) filtrationinfo@parker.com Product Features: moisture sensors provide fast, reliable and accurate inline detection of moisture in fluids. Technology developed for preventative maintenance programmes. low pressure suction/return line applications. bar maximum operating pressure. Programmable sensor monitoring and reporting relative humidity (RH), moisture content in oils. bar MAOP. Intrinsically safe sensor ATEX certificated for use in hazardous Zone environments. bar MAOP. Temperature Outputs on all versions. www.parkerhfde.com 8 FDHBUK.
icount Range Cost Effective Moisture Detection Features &Benefits Continuous, online moisture indication, for hydraulic and lubricating systems. Reporting of %relative humidity of water content, giving the user information on how close to the fluids real saturation point. Reliable data on the rate of water absorption. Sensing cell technology using a laser trimmed thermoset polymer, for capacitive sensing that is capable of absorbing water molecules due to its micro porous structure. Uses a thermistor for temperature compensation correction. Offering total confidence in reporting the %RH relative humidity over the sensors temperature range. Apurpose designed tee adaptor allows for easy installation into an existing fluid system. The can also be specified with abench top wand offering the end user greater flexibility. Not available on Typical Applications Ground support vehicles Pulp and paper plants Marine hydraulics Power transmission & distribution Forestry Industrial hydraulics Earth moving applications Agricultural Hazardous Areas (Zone ) Theme parks (Ride hydraulics) In-Line Moisture Measurement of Hydraulic &Lubricating Oils. Parkers Moisture Sensor Range offers fast, reliable and accurate in-line detection of moisture in fluids. The transducer type technology has been especially designed with the preventative maintenance programme environment in mind. The industry accepted sensing cell device will monitor and report Relative Humidity (RH), moisture content in oils. The water content measurement technique offers the end user benefits over the current standard form of water content reporting (PPM). This allows for real time preventative maintenance to be undertaken and corrective actions to be made. By knowing that the water contamination is still within the oils absorbing range, less than %, reclaiming fluid properties before additive damage occurs can initiate calculable cost savings. 8 FDHBUK.
Moisture Sensor Specification Pressure: Maximum allowable operating pressure. (MAOP): bar ( PSI). Operating temperature: Minimum: - C (- F). Maximum: +8 C (+8 F). Flow through sensor cell: Installed in active flowstream. Fluid compatibility: Mineral oils, petroleum-based and Phosphate ester. Viscosity range: Unlimited. Port connections: / BSPT or / NPT. Supply voltage: +8 to + Vdc. Sensor size/weight/material: 8mm x mm/.kg/aluminium IP ratings: IP8 %RH Outputs: (+ to + Vdc) or ( to ma) Temperature Outputs: to+vdc Installation Details 87-88. A/F.. Thread Form Options BSPT. Ø8. Ø. Ø. R / BSPT. maximum All dimensions in millimetres (mm) Sensor Outputs Dimensions are for reference only Flow in either direction Tapping drill Tap to gauge.8 with. without Pin Designation Supply %RH %RH Temperature Common moisture sensor pin designations I/O Input Output Output Output Input Description Supply voltage (+8 to +Vdc) % Saturation out (+ to +Vdc) % Saturation out (+ to +ma) Temperature out ( to +Vdc) Common (Vdc) ground from power supply (not chassis ground) NPT Ø. Installation details for R / BSPT taper 7. Interpreting the data Oil type: Texaco Rando. Saturation point: ppm @ ºC (ºF). At the above operating condition, the meter displays % saturation. As the meters scale indicates a reduction in the saturation percentage, there is also a corresponding reduction in PPM at a constant temperature. In the example above, a meter reading of % saturation could be interpreted as ppm at ºC (ºF). Flow in either direction / NPT. maximum Tapping drill.7 with. without Installation details for / NPT 87 FDHBUK.
Programmable Specification % Saturation Calibration Accuracy: +% RH Temperature Calibration Accuracy: ± C Thermal Stability: ±% RH (over compensated temperature range + to +8 C) Stability: ±.% RH typical at % RH in year Linearity: ±.% RH typical Analogue Output Hysteresis: ±.% RH Full Scale Switched Output Hysteresis: % RH Operating Temperature Range: - C to +8 C (- to +8 F) Operating Humidity Range: to % RH (non condensing) Response Time: sec in slow moving air at C Maximum rated pressure: Bar ( PSI) Maximum torque on spanner flats: Nm (ONLY USE SPANNER FLATS TO INSTALL ANDREMOVE THE MOISTURE SENSOR) Seal Material (depending on ): Fluorocarbon, EPDM, Perfluoroelastomer Material: Stainless Steel Connector Details: Mx, 8 Way, IP7 Connector (IP8 when mated with moulded cable) Maximum Cable Length: Metres with Voltage Output Metres with Current Output Output: SEE ORDERING INFORMATION Installation Details Ø.. -7 7.. Ø.. Ø... A/F Hexagon Thread detail dice pattern M x. pitch. Moisture Sensor Wiring and Pin Designations Pin Wire Colour Designation I/O Description Brown Analogue Output Temperature - Degí Celsius. User Select Output (-Vdc, -Vdc, -Vdc and -ma). Green Alarm Limit Output Alarm Limit. Output that directly corresponds to the alarm set point. Yellow Analogue Output % Saturation. User Select Output (-Vdc, -Vdc, -Vdc and -ma). Grey Receive Input RS Communication. Pink Send Output RS Communication. Blue Common Input Common (Vdc). Ground from power supply. Pin Pin 8 Pin 7 White Alarm Switch Output Alarm Switch. Constant Vdc when in normal operation. Switch to Vdc when in alarm condition. Red LED illuminates when Sensor is in an alarm condition. 8 Red Supply Input Supply Voltage (+8 to +Vdc). Green LED illuminates when power is properly applied. 88 FDHBUK.
Intrinsically Safe Specification Pressure: Maximum allowable operating pressure. (MAOP): bar ( PSI). Operating temperature: Minimum: - C (- F) - dependent on seal material. Maximum: +8 C (+8 F). Flow through sensor cell: Installed in active flowstream. Fluid compatibility: Mineral oils, petroleum-based and Phosphate ester- Skydrol option available. Viscosity range: Unlimited. Thread form connections: See ordering information. Outputs: -ma (current loop). Calibration accuracy: +/- % RH Compensated thermal stability: +/- % RH (+ C to +8 C) Materials: Stainless steel. Sensor size/weight: 7mm x ømm/.kg. IP ratings: IP8 (with specified moulded cable) Developed in association with Triteq Ltd. Installation Details - See The has been certified as Intrinsically Safe Electrical Apparatus and offers fast, reliable and accurate in-line detection of moisture in fluids for use in hazardous areas. ATEX Certification allows the into areas of a potentially explosive atmosphere, that have previously not been allowed without permits, it is intended for use in Zone hazardous areas requiring the use of category G equipment and has been designed for use with galvanic isolators to the specified values stated below: The electrical parameters: Ui: 8V Ii: 9mA Pi:.W Ci: 8nF Li: The following instructions apply to - -ma Current Loop Moisture Sensor covered by certificate number Sira 7ATEX:. The equipment may be located where flammable gases of Group I may be present. The equipment is only certified for use in ambient temperatures in the range - C to + C and should not be used outside this range.. The equipment has not been assessed as a safety-related device (as referred to by Directive 9/9/EC Annex II, clause.).. Installation of this equipment shall be carried out by suitably trained personnel in accordance with the applicable code of practice.. Repair of this equipment shall be carried out by the manufacturer or in accordance with the applicable code of practice (IEC 79-9). 89 FDHBUK.
Visual Indicators Specifications Bar Graph Indicator (PBG8A) Construction: Housing nylon /, window acrylic, bezel/board supports ABS, pins phosphor bronze. Power supply: Vdc. Signal input: (By dipswitch configuration) Off differential up to V. A single signal (Ref. V) up to V. B single signal (Ref. V) up to V. Cut out size:.mm x.mm. Fixing: Push fit panel thickness.9mm to.mm. Sealing: Designed to IP standard. (Front face may be silicon sealed after LED configuration). Scale: Supplied to % in horizontal. Other scales, in volume, consult. Scaling factors: % to % range. Fully adjustable. Lamp intensity: mcd each. Front viewing: Polarised. Weight: 9gms. Alternative Indicator Description Power supply Accuracy Sample rate Operating temp ( C) Storage temp ( C) Display Power output (Vdc) Weight (kg) Panel cutout (mm) Dimensions (mm) PBG8A DDU -Vdc ±.% typical. per second - - to +7. digit LED. 9x ±. 8x9x9 DDU/DDU DDU - Vdc ±.% typical. per second - - to +7 / digit LED. 9x ±/. 8x9x9 Product accessories part numbers Product Number Supersedes Description DDU P.97PVC- Digital display unit - Vdc DDU P.97PVC- Digital display unit - Vdc PBG8A PBG.8.A Bar Graph Indicator (+ to + Vdc) PAM8 PAM.8 Bar Graph alarm module ACCNF B97 meter M, 8 pin moulded cable (IP8) ACCNF P97 M, pin rewireable connector (IP) ACCNF S97 meter extension box ACCNE8 S97 UK volt power supply ACCNE9 S97 European volt power supply ACCNE S97 US volt power supply ACCNF N/A metre M, pin moulded cable (IP8) Moisture sensor output setting The Moisture sensor reports on the saturation levels of the fluid passing through the sensing cell. The output is a linear scale, reporting within the range of % saturation to % saturation. Saturation ma Vdc Vdc % % % 7% %.8 8..7.......7. 9 FDHBUK.
Ordering Information Standard Product Table Product Number Supersedes Fluid type - Mineral + Aggressive - Mineral + Aggressive Thread Forms G / BSPT Taper / NPT Taper Connector M WAY M WAY - Product Configurator Key Model Fluid type Output Options Thread Forms Connector Future option Programmable Mineral Aggressive -Vdc -Vdc -Vdc G / BSP Bonded Seal G / BSP Integral Seal R / Taper M 8 WAY No -ma / NPT Taper 9/ - 8 UNF A Integral Seal Hand Held Unit 7 G /8 BSP Female Swivel Equal T adaptor - Standard Product Table Key Model Fluid type Output Options Thread Forms Connector Future option - Product Configurator Key Model Fluid type Output Thread form Connector Future option Programmable Mineral Aggressive -ma G / BSP Bonded Seal G / BSP Integral Seal R / Taper Thread WAY None / NPT Taper Thread 9/ - 8 UNF A Integral Seal G /8 BSP Female Swivel Equal Tee - Standard Product Table Key Model Fluid type Output Thread Forms Connector Future option 9 FDHBUK.