icountms Range Fluid Condition Monitoring Moisture Sensors

Similar documents
Druck DPI 705/DPI 705 IS Series

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

IRceL CH4 Methane (CH 4

icount Oil Sampler (IOS) Portable Condition Monitoring for Hydraulic Oil and Fuel Systems

4) Intrinsic Safety Certification

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

Parker icount Oil Sampler (IOS)

INSTRUCTION MANUAL (ATEX)

MICROpeL 75 Combustible Gas Sensor Part Number: PM

M7100 Pressure Transducer

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

E2S Datasheet v10a

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

Dew-Point Transmitters and Instruments

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

icount Oil Sampler (IOS)

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

M5200 Industrial Pressure Transducer

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

U5700 Submersible Liquid Level Pressure Transducer

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Oil & Gas. Features:

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

Rosemount 3100 Series Ultrasonic Level Transmitters

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

Software Version 2.01 LEVEL MONITOR MODEL 220

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

M5800 Pressure Transducer with Rotatable Display

U5300 Industrial Pressure Transducer

DB5 Intrinsically Safe Sounder Type DB-5

P R O D U C T D ATA S H E E T

VQ500 Series Combustible Gas Detector Elements

DP86 Constant Voltage with Fitting

Beck. The differential pressure transmitter for air

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

IR25 Dual Gas Series Datasheet

WIO 200B and WIOI200B Water in oil sensor

WIO200 Water In Oil measuring instrument

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

gas monitoring system

portable gas analyser

VERSAFLOW VORTEX Supplementary instructions

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Air Sensor. SAC Ex FCS Ex. Manual ATEX. AQ M-Tech AB

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated

P R O D U C T D ATA S H E E T

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

Model HL-Z. High Line Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES POTENTIAL APPLICATIONS

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

SILO PROTECTION SYSTEMS

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

D5100 Industrial Differential Pressure Transducer

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

INSTRUCTION MANUAL. SIL 2 Load Cell/Strain Gauge Bridge Isolating Converter DIN-Rail Power Bus and Termination Board Model D5264S D5264S

Rosemount 2051T In-Line Pressure Transmitter

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

P125 High Pressure Sensor

Specifications: ACCURACY: RH: ±1% Temperature: ±0.5 C. Dew point: Typically, +/-2.0C above 0C; +/-3.0C 0 to -60C OPERATING RANGE:

D3000. Installation & Setup Guide

CE110I. Piezoelectric accelerometer with integrated electronics. IECEx

GuideLine 2. Highly Visible Alignment Lasers for Visually Demanding Surfaces

FCHM Hydromatic Pump Control Module

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

Model 144H. Product Data Sheet , Rev DB February Content

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

Oxygen Sensing Solutions

D5100 Industrial Differential Pressure Transducer

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Lamp Supply (Recommended)

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Ex Long & Short stroke LPI POSITION TRANSMITTER MKII For linear position measurement in compressors

U5600. Wireless Pressure Transducer SPECIFICATIONS

Model Super TJE. Ultra Precision Pressure Transducer DESCRIPTION FEATURES

Rosemount 3100 Series Ultrasonic Level Transmitters

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

89BSD Digital Output

P R O D U C T D ATA S H E E T

VQ600 Datasheet. Pellistor Gas Sensor for Hazardous Areas (Fixed Systems) FEATURES TECHNICAL SPECIFICATION OPERATION

Certificate of Compliance

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Fill Point, Level Gauges, and Control Range

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

PM100V PM80V PM15V. Ex works. Depending on the specific range of application a regular ecalibration of the sensor head (PMU-V) has to be effected.

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

User s Manual YTA610 and YTA710 NEPSI Certification

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

Transcription:

icount Range Fluid Condition Monitoring Moisture Sensors An essential component of any predictive maintenance programme Fast, reliable and accurate inline detection of moisture in fluids moisture sensors provide fast, reliable and accurate inline detection of moisture in fluids. Technology developed for preventative maintenance programmes. is the low pressure option for suction line/reservoir applications. is the Programmable sensor monitoring and reporting relative humidity (RH), moisture content in oils. Intrinsically safe sensor ATEX certified for use in hazardous Zone environments. Contact Information: European Product Information Centre Freephone: 8 7 7 7 (from AT, BE, CH, CZ, DE, EE, ES, FI, FR, IE, IT, PT, SE, SK, UK) filtrationinfo@parker.com Product Features: moisture sensors provide fast, reliable and accurate inline detection of moisture in fluids. Technology developed for preventative maintenance programmes. low pressure suction/return line applications. bar maximum operating pressure. Programmable sensor monitoring and reporting relative humidity (RH), moisture content in oils. bar MAOP. Intrinsically safe sensor ATEX certificated for use in hazardous Zone environments. bar MAOP. Temperature Outputs on all versions. www.parkerhfde.com 8 FDHBUK.

icount Range Cost Effective Moisture Detection Features &Benefits Continuous, online moisture indication, for hydraulic and lubricating systems. Reporting of %relative humidity of water content, giving the user information on how close to the fluids real saturation point. Reliable data on the rate of water absorption. Sensing cell technology using a laser trimmed thermoset polymer, for capacitive sensing that is capable of absorbing water molecules due to its micro porous structure. Uses a thermistor for temperature compensation correction. Offering total confidence in reporting the %RH relative humidity over the sensors temperature range. Apurpose designed tee adaptor allows for easy installation into an existing fluid system. The can also be specified with abench top wand offering the end user greater flexibility. Not available on Typical Applications Ground support vehicles Pulp and paper plants Marine hydraulics Power transmission & distribution Forestry Industrial hydraulics Earth moving applications Agricultural Hazardous Areas (Zone ) Theme parks (Ride hydraulics) In-Line Moisture Measurement of Hydraulic &Lubricating Oils. Parkers Moisture Sensor Range offers fast, reliable and accurate in-line detection of moisture in fluids. The transducer type technology has been especially designed with the preventative maintenance programme environment in mind. The industry accepted sensing cell device will monitor and report Relative Humidity (RH), moisture content in oils. The water content measurement technique offers the end user benefits over the current standard form of water content reporting (PPM). This allows for real time preventative maintenance to be undertaken and corrective actions to be made. By knowing that the water contamination is still within the oils absorbing range, less than %, reclaiming fluid properties before additive damage occurs can initiate calculable cost savings. 8 FDHBUK.

Moisture Sensor Specification Pressure: Maximum allowable operating pressure. (MAOP): bar ( PSI). Operating temperature: Minimum: - C (- F). Maximum: +8 C (+8 F). Flow through sensor cell: Installed in active flowstream. Fluid compatibility: Mineral oils, petroleum-based and Phosphate ester. Viscosity range: Unlimited. Port connections: / BSPT or / NPT. Supply voltage: +8 to + Vdc. Sensor size/weight/material: 8mm x mm/.kg/aluminium IP ratings: IP8 %RH Outputs: (+ to + Vdc) or ( to ma) Temperature Outputs: to+vdc Installation Details 87-88. A/F.. Thread Form Options BSPT. Ø8. Ø. Ø. R / BSPT. maximum All dimensions in millimetres (mm) Sensor Outputs Dimensions are for reference only Flow in either direction Tapping drill Tap to gauge.8 with. without Pin Designation Supply %RH %RH Temperature Common moisture sensor pin designations I/O Input Output Output Output Input Description Supply voltage (+8 to +Vdc) % Saturation out (+ to +Vdc) % Saturation out (+ to +ma) Temperature out ( to +Vdc) Common (Vdc) ground from power supply (not chassis ground) NPT Ø. Installation details for R / BSPT taper 7. Interpreting the data Oil type: Texaco Rando. Saturation point: ppm @ ºC (ºF). At the above operating condition, the meter displays % saturation. As the meters scale indicates a reduction in the saturation percentage, there is also a corresponding reduction in PPM at a constant temperature. In the example above, a meter reading of % saturation could be interpreted as ppm at ºC (ºF). Flow in either direction / NPT. maximum Tapping drill.7 with. without Installation details for / NPT 87 FDHBUK.

Programmable Specification % Saturation Calibration Accuracy: +% RH Temperature Calibration Accuracy: ± C Thermal Stability: ±% RH (over compensated temperature range + to +8 C) Stability: ±.% RH typical at % RH in year Linearity: ±.% RH typical Analogue Output Hysteresis: ±.% RH Full Scale Switched Output Hysteresis: % RH Operating Temperature Range: - C to +8 C (- to +8 F) Operating Humidity Range: to % RH (non condensing) Response Time: sec in slow moving air at C Maximum rated pressure: Bar ( PSI) Maximum torque on spanner flats: Nm (ONLY USE SPANNER FLATS TO INSTALL ANDREMOVE THE MOISTURE SENSOR) Seal Material (depending on ): Fluorocarbon, EPDM, Perfluoroelastomer Material: Stainless Steel Connector Details: Mx, 8 Way, IP7 Connector (IP8 when mated with moulded cable) Maximum Cable Length: Metres with Voltage Output Metres with Current Output Output: SEE ORDERING INFORMATION Installation Details Ø.. -7 7.. Ø.. Ø... A/F Hexagon Thread detail dice pattern M x. pitch. Moisture Sensor Wiring and Pin Designations Pin Wire Colour Designation I/O Description Brown Analogue Output Temperature - Degí Celsius. User Select Output (-Vdc, -Vdc, -Vdc and -ma). Green Alarm Limit Output Alarm Limit. Output that directly corresponds to the alarm set point. Yellow Analogue Output % Saturation. User Select Output (-Vdc, -Vdc, -Vdc and -ma). Grey Receive Input RS Communication. Pink Send Output RS Communication. Blue Common Input Common (Vdc). Ground from power supply. Pin Pin 8 Pin 7 White Alarm Switch Output Alarm Switch. Constant Vdc when in normal operation. Switch to Vdc when in alarm condition. Red LED illuminates when Sensor is in an alarm condition. 8 Red Supply Input Supply Voltage (+8 to +Vdc). Green LED illuminates when power is properly applied. 88 FDHBUK.

Intrinsically Safe Specification Pressure: Maximum allowable operating pressure. (MAOP): bar ( PSI). Operating temperature: Minimum: - C (- F) - dependent on seal material. Maximum: +8 C (+8 F). Flow through sensor cell: Installed in active flowstream. Fluid compatibility: Mineral oils, petroleum-based and Phosphate ester- Skydrol option available. Viscosity range: Unlimited. Thread form connections: See ordering information. Outputs: -ma (current loop). Calibration accuracy: +/- % RH Compensated thermal stability: +/- % RH (+ C to +8 C) Materials: Stainless steel. Sensor size/weight: 7mm x ømm/.kg. IP ratings: IP8 (with specified moulded cable) Developed in association with Triteq Ltd. Installation Details - See The has been certified as Intrinsically Safe Electrical Apparatus and offers fast, reliable and accurate in-line detection of moisture in fluids for use in hazardous areas. ATEX Certification allows the into areas of a potentially explosive atmosphere, that have previously not been allowed without permits, it is intended for use in Zone hazardous areas requiring the use of category G equipment and has been designed for use with galvanic isolators to the specified values stated below: The electrical parameters: Ui: 8V Ii: 9mA Pi:.W Ci: 8nF Li: The following instructions apply to - -ma Current Loop Moisture Sensor covered by certificate number Sira 7ATEX:. The equipment may be located where flammable gases of Group I may be present. The equipment is only certified for use in ambient temperatures in the range - C to + C and should not be used outside this range.. The equipment has not been assessed as a safety-related device (as referred to by Directive 9/9/EC Annex II, clause.).. Installation of this equipment shall be carried out by suitably trained personnel in accordance with the applicable code of practice.. Repair of this equipment shall be carried out by the manufacturer or in accordance with the applicable code of practice (IEC 79-9). 89 FDHBUK.

Visual Indicators Specifications Bar Graph Indicator (PBG8A) Construction: Housing nylon /, window acrylic, bezel/board supports ABS, pins phosphor bronze. Power supply: Vdc. Signal input: (By dipswitch configuration) Off differential up to V. A single signal (Ref. V) up to V. B single signal (Ref. V) up to V. Cut out size:.mm x.mm. Fixing: Push fit panel thickness.9mm to.mm. Sealing: Designed to IP standard. (Front face may be silicon sealed after LED configuration). Scale: Supplied to % in horizontal. Other scales, in volume, consult. Scaling factors: % to % range. Fully adjustable. Lamp intensity: mcd each. Front viewing: Polarised. Weight: 9gms. Alternative Indicator Description Power supply Accuracy Sample rate Operating temp ( C) Storage temp ( C) Display Power output (Vdc) Weight (kg) Panel cutout (mm) Dimensions (mm) PBG8A DDU -Vdc ±.% typical. per second - - to +7. digit LED. 9x ±. 8x9x9 DDU/DDU DDU - Vdc ±.% typical. per second - - to +7 / digit LED. 9x ±/. 8x9x9 Product accessories part numbers Product Number Supersedes Description DDU P.97PVC- Digital display unit - Vdc DDU P.97PVC- Digital display unit - Vdc PBG8A PBG.8.A Bar Graph Indicator (+ to + Vdc) PAM8 PAM.8 Bar Graph alarm module ACCNF B97 meter M, 8 pin moulded cable (IP8) ACCNF P97 M, pin rewireable connector (IP) ACCNF S97 meter extension box ACCNE8 S97 UK volt power supply ACCNE9 S97 European volt power supply ACCNE S97 US volt power supply ACCNF N/A metre M, pin moulded cable (IP8) Moisture sensor output setting The Moisture sensor reports on the saturation levels of the fluid passing through the sensing cell. The output is a linear scale, reporting within the range of % saturation to % saturation. Saturation ma Vdc Vdc % % % 7% %.8 8..7.......7. 9 FDHBUK.

Ordering Information Standard Product Table Product Number Supersedes Fluid type - Mineral + Aggressive - Mineral + Aggressive Thread Forms G / BSPT Taper / NPT Taper Connector M WAY M WAY - Product Configurator Key Model Fluid type Output Options Thread Forms Connector Future option Programmable Mineral Aggressive -Vdc -Vdc -Vdc G / BSP Bonded Seal G / BSP Integral Seal R / Taper M 8 WAY No -ma / NPT Taper 9/ - 8 UNF A Integral Seal Hand Held Unit 7 G /8 BSP Female Swivel Equal T adaptor - Standard Product Table Key Model Fluid type Output Options Thread Forms Connector Future option - Product Configurator Key Model Fluid type Output Thread form Connector Future option Programmable Mineral Aggressive -ma G / BSP Bonded Seal G / BSP Integral Seal R / Taper Thread WAY None / NPT Taper Thread 9/ - 8 UNF A Integral Seal G /8 BSP Female Swivel Equal Tee - Standard Product Table Key Model Fluid type Output Thread Forms Connector Future option 9 FDHBUK.