REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

Similar documents
REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

Energy Star Directional Luminaire Test Report ELEC-TECH INTERNATIONAL CO LTD. LED Downlight

Annexure-I. 1. Goniophotometer and Goniospectroradiometric measurement System

BUG stands for Backlight, Uplight and Glare. The acronym

FLASHLIGHT ANSI STANDARDS

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1

Challenges in SSL Design and Photometric testing Gautam Brahmbhatt, Head Technical (Verification Service)

LED Reliability and Current Standards for Measurement

RENDERED TO. Radial Engineering Limited 1588 Kebet Way Port Coquitlam, B.C. V3C 5M5

RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

Safety Certification of Solid-State Lighting Products. September 23, 2009 Todd Straka Director - Lighting Services

Energy Solutions LED Accelerator Program PRODUCT QUALIFICATION REQUIREMENTS 2015

Vaya Linear LP, White & Mono

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

E10 & L9 Low Wattage Light Cone Data

Basics Series Surface Mount LED Fixtures. Affordable and easy-to-install, 4" and 6" fixtures. It s a. Snap

DRD5S & SurfaceFrame Alt/EM Surface Mount LED Downlight

Product Description. Features. Table of Contents. CLM-DS08 Rev 11. Product family data sheet. Source with

Albeo LED Luminaire. Heavy Industrial Low Bay Lighting. (ALR1 - Series)

Millenium Os. Luminaire LED. For Stairwells and Public Spaces. Designed and manufactured in the USA. High Abuse Motion-Activated Lighting Product

Fast. Precise. Versatile. UL Lighting Sciences

Fortimo LED Line Gen2 Module

Fortimo LED Line High Flux Module

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

REPORT NUMBER: MID-003r1 ORIGINAL ISSUE DATE: March 11, 2015 Revised Date: March 20, 2015

SECTION INTERIOR LIGHTING

LED retrofits! 4 T8 Specification Guide. Retrofit your existing Fluorescent Lights in Seconds No Electrician Needed! Pure Bright

2200TD-3000TD Dim to Warm* 2700T-6500T Tunable White* *Must be ordered with D05 or DS5 Driver options; excludes 2' and 3' lengths

T8 Self Ballasted UL & CSA LED TUBE RETROFITS

ENGINEERING EVALUATION

Product Specifications MaxLumen MRI LED Diffused Lighting

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

Lighting Measurement Solutions

SIGMADEK, LTD. FIRE TEST REPORT

SDL4 LED Strip Diffused Lens

Technical application guide

Overview of International Lighting Standards Steve Coyne Director, Light Naturally UNEP Consultant

Technical application guide

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

LHB LED High Bay. Technical Specifications. Description. Performance Data. Dimensions & Weights. Delivered Lumens Efficacy.

FABRITRAK SYSTEMS, INC. FIRE TEST REPORT

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

Dimensions (111mm) (111mm) 3 (76mm)

Rating. Class I Div II

lumenalpha downlight Specification Sheet

Product Specifications MaxLumen MRI LED Diffused Lighting

Solid State Lighting Sub-Assembly Interfaces for Luminaires. Andrew D. Jackson Philips Lighting Corporate Regulatory and Certification Laboratory

Table of Contents. Product Description. Features. CLM-DS08 Rev 9A. Product family data sheet. Source with. Characteristics - WhiteLight Dimming...

Optics & Radiometry Laboratory

DHL-LP-LED Low Profile LED Linear High/Low Bay

Type: Project : Luminaire characteristics: Source: Lumen maintenance: Optics: Material: Mounting: Electrical: Finish: Weight:

Philips MASTER LEDbulb DIM W & W E27/B K 230 V

DRAFT. Models: LED-8085M30, LED-8085M30C; LED-8085M42, LED-8085M42C; LED-8085M57, LED-8085M57C

Refrigerating Appliance DOE Test Report

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008

BAS SDL8' LED Strip Diffused Lens

FPLHB - Fidelux Premier Linear Highbay

Technical Application Guide for UP-SHINE LED Track Light

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

DRD5S & SurfaceFrame Alt/EM 18" Linear Surface Mount LED Area Light

Recessed LED Wall/Slot SAE 202

Fahrenheit Recessed LED Downlight Fire and Sound-Rated New Construction 4, 5, 6 Aperture

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

Fire Performance of Translucent Systems

IBLED SERIES 4' PROJECT: FEATURES AND SPECIFICATIONS LINE DRAWING

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

PD-32: Light Pollution

Philips MASTER LEDbulb 7-40 W and W E27/B K 230 V

CLARA AC Crystal CLARA AC 50. LED-modules for downlight. A qualified solution to replace and exceed Halogen solutions in Downlights.

CLM 422 Series LED Ceiling Luminaire Module - 45Watt

2018 Midstream Lighting Product Catalog

Optical Measurement Techniques for LED Clusters and LED Safety

928 E. 10 Mile Road (Site Plan)

Optical Testing Report for 46 Lamp Sample Sets

STREET LIGHTING CATALOGUE

SL3255 Surface Mount Underwater Light UNDERWATER LED LIGHTING

Lumination LED Luminaires

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

DEPARTMENT OF THE AIR FORCE HEADQUARTERS AIR FORCE CIVIL ENGINEER SUPPORT AGENCY

Medical LED. Superbly balanced and colour corrected LED-modules for medical use.

Are LED s ready for Prime Time?

This is a preview - click here to buy the full publication

FUNDERMAX GMBH FIRE TEST REPORT

Product Specifications MaxLumen MRI LED Diffused Lighting

Cree XLamp MT-G MR16 Reference Design

Evolution EXWW RECESSED LINEAR WALL WASH LUMINAIRE

Project: Comments: Prepared By: Control. Code Fixture & Trim D3 Wall Wash, Round. Platform & Control Wide Gamut, Tunable

MANDATORY MEASURES. There are two major steps for exterior spaces to comply with Title 24:

DOME SERIES. Data will be subject to change without notice. COMMERCIAL 1

Transcription:

. REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 Project No. G102748333 Date: February 21, 2017 REPORT NO. 102748333CHI-024 TEST OF ONE LED WALL PACK MODEL NO. WPFC-CW70 LED MODEL NO. PHILIPS LUMILEDS L130-5080003000W21 DRIVER MODEL NO. MESTER LED MSPI-IS70A12S-1750 RENDERED TO SUPER BRIGHT LEDS, INC. 4400 EARTH CITY EXPRESSWAY SAINT LOUIS, MO 63045 TEST: Electrical and Photometric tests as required to the IESNA test standard. AUTHORIZATION: The testing performed was authorized by signed quote number Qu-00723537-3. STANDARDS USED: The following American National Standards or Illuminating Engineering Society of North America Test Guides were used in part or totally to test each specimen: IESNA LM-79-2008: Electrical and Photometric Measurements of Solid State Lighting ANSI NEMA ANSLG C78.377: 2012: Specifications of the of Solid State Lighting Products DESCRIPTION OF SAMPLE: DATES OF TESTS: The client submitted one Production sample of model number WPFC-CW70. The sample was received by Intertek on February 10, 2017, in undamaged condition and one sample was tested as received. The sample designation was AH02102017050950D. February 16, 2017 through February 21, 2017. This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.

SUMMARY Model No.: WPFC-CW70 Description: LED Wall Pack Result Criteria Sphere Goniometer Total Lumen Output (Lumens) 7780 7602 Total (W) 68.16 68.20 Luminaire Efficacy (LPW) 114.1 111.5 Criteria Result Factor at 120Vac 0.983 Factor at 277Vac 0.902 Current ATHD % at 120Vac 15.96 Current ATHD % at 277Vac 19.85 Correlated Color Temperature (CCT - K) 5269 Color Rendering Index (CRI - Ra) 84.4 Color Rendering Index (CRI - R9) 15.3 DUV 0.000 Coordinate (x) 0.338 Coordinate (y) 0.347 Coordinate (u') 0.208 Coordinate (v') 0.481 BUG Rating B3-U2-G1 IES Classification Type I Longitudinal Classification Very Short EQUIPMENT LIST Equipment Used Yokogawa Meter Omega Newport Thermometer LSI High Speed Mirror Goniometer Newport Thermohygrometer Pacific, AC power supply Labsphere Spectroradiometer 3 Meter Sphere Elgar AC Supply Sorenson DC Supply Newport Humidity Recorder Yokogawa Meter Fluke J/K Temperature Meter Model Control Last Date Calibration Number Number Calibrated Due Date WT210 146919 07/11/16 07/11/17 DPI8-C24 146920 10/07/16 10/07/17 6440T 146928 VBU VBU iserver 146956 01/06/17 01/06/18 118-ACX CHI0358 VBU VBU CDS1100 CHI0091 VBU VBU SPR600 CHI0088 VBU VBU CW1251M 146112 VBU VBU XFR150-8 146846 VBU VBU ithx-sd 146382 06/27/16 06/27/17 WT1600 146768 01/10/17 01/10/18 52 146004 01/10/17 01/10/18 Date Used Report No. 102748333CHI-024 2 of 7 Date: February 21, 2017

TEST METHODS Seasoning in Sample Orientation LED Products No seasoning was performed in accordance with IESNA LM-79. Photometric and Electrical Measurements Integrating Sphere Method A Labsphere Model CDS 1100 CCD Array Spectroradiometer and Two Meter or Ten Foot Sphere was used to measure correlated color temperature, chromaticity coordinates, and the color rendering index for each SSL unit. Ambient temperature was measured at a position inside the sphere. Each SSL unit was operated on the client provided driver at the rated input voltage in its designated orientation. Each SSL unit was allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements including voltage, current, and power were measured using the Xitron or Yokogawa Analyzer. The calibration of the sphere photometer-spectroradiometer system is traceable to the National Institute of Standards and Technology. Photometric and Electrical Measurements Distribution Method A LSI Type C High Speed Model 6440 Mirror Goniometer was used to measure the intensity (candelas) at each angle of distribution for each sample. Ambient temperature was measured equal to the height of the sample mounted on the Goniometer equipment. Each sample was operated at input rated voltage in its designated orientation. Each sample was allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements including voltage, current, and power were measured using the Xitron or Yokogawa Analyzer. Some graphics were created with Photometrics Plus software. BUG Ratings (Backlight, Uplight, Glare) for Outdoor Fixtures Only Zonal Lumens were calculated and grouped using the formula in IESNA TM-15-11 for each zone as defined in the BUG addendum. The maximum lumen rating in each zone was compared against the BUG zonal requirements of Energy Star. Photometric Toolbox software was used to calculate results. Report No. 102748333CHI-024 3 of 7 Date: February 21, 2017

RESULTS OF TEST Photometric and Electrical Measurements at Ambient Temperature (25 C +/- 1 C) - Integrating Sphere Method Intertek Sample No. AH02102017050950D Base Orientation Horizontal Voltage {VAC} Current (ma) (Watts) Factor 120.0 577.5 68.16 0.983 277.0 276.6 69.14 0.902 Current ATHD (%) 15.96 Luminous Flux (Lumens) 7780 Lumen Efficacy (LPW) 114.1 19.85 Correlated Color Temperature (K) 5269 CRI -Ra 84.4 CRI -R9 15.3 DUV 0.000 CIE 31 Coordinate (x) 0.338 CIE 31 Coordinate (y) 0.347 CIE 76 Coordinate (u ) 0.208 CIE 76 Coordinate (v ) 0.481 Spectral Distribution over Visible Wavelengths nm mw/nm nm mw/nm nm mw/nm nm mw/nm nm mw/nm 350 0.704 440 76.20 530 94.43 620 86.29 710 9.442 355 0.712 445 125.9 535 96.37 625 80.65 715 8.114 360 0.705 450 180.6 540 97.80 630 74.69 720 6.991 365 0.648 455 177.3 545 99.48 635 68.68 725 6.006 370 0.596 460 126.0 550 101.0 640 62.54 730 5.140 375 0.568 465 94.95 555 102.4 645 56.53 735 4.394 380 0.567 470 74.75 560 103.8 650 50.76 740 3.753 385 0.539 475 56.14 565 105.1 655 45.27 745 3.222 390 0.597 480 48.53 570 106.3 660 40.12 750 2.769 395 0.723 485 48.68 575 107.2 665 35.25 755 2.385 400 0.958 490 51.94 580 107.7 670 30.86 760 2.075 405 410 415 1.496 2.635 4.802 495 500 505 58.37 66.14 73.69 585 590 595 107.6 106.7 105.0 675 680 685 26.95 23.39 20.28 765 770 775 1.790 1.534 1.331 420 8.593 510 79.83 600 102.7 690 17.47 780 1.149 425 15.32 515 85.04 605 99.83 695 15.04 430 26.53 520 89.08 610 95.94 700 12.87 435 45.48 525 92.10 615 91.43 705 11.03 Spectral Data Over Visible Wavelengths 200.000 180.000 160.000 140.000 120.000 100.000 80.000 60.000 40.000 20.000 0.000 350 400 450 500 550 600 650 700 750 800 (mw/nm) Nanometers Report No. 102748333CHI-024 4 of 7 Date: February 21, 2017

RESULTS OF TEST (cont'd) Photometric and Electrical Measurements at Ambient Temperature (25 C +/- 1 C) Distribution Method Absolute Intertek Sample No. AH02102017050950D Base Orientation Horizontal Voltage {VAC} 120.1 Current (ma) 577.5 (Watts) 68.20 Factor 0.983 Luminous Flux (Lumens) 7602 Lumen Efficacy (LPW) 111.5 Intensity (Candlepower) Summary at 25 C - Candelas Angle 0 25 45 67.5 90 0 4352 4352 4352 4352 4352 5 10 4134 3878 4148 3888 4214 4022 4292 4196 4359 4334 15 20 3691 3344 3677 3387 3780 3567 4071 3910 4280 4205 25 2818 2929 3280 3700 4106 30 35 40 45 50 55 2196 1713 1430 1272 1157 993 2366 1848 1489 1268 1127 983 2871 2371 1903 1507 1225 997 3431 3109 2738 2318 1870 1454 3983 3816 3598 3328 2968 2518 60 65 70 75 80 85 732 503 344 251 214 106 779 528 338 231 189 92 787 558 360 227 150 79 1061 681 412 264 158 73 1979 1259 689 386 181 71 90 95 100 42 30 13 37 24 10 29 17 7 18 9 5 10 6 4 Report No. 102748333CHI-024 5 of 7 Date: February 21, 2017

RESULTS OF TEST (cont'd) Illumination Plots Illuminance - Cone of Light Mounting Height: 10 ft. Isoillumination Plot Zonal Lumen Summary and Percentages at 25 C Zone 0-30 0-40 0-60 60-90 0-90 90-180 0-180 Lumens 2989 4491 6649 936.4 7586 16.2 7602 % Luminaire 39.3 59.1 87.5 12.3 99.8 0.2 100.0 Luminaire Classification System (LCS) LCS Zone Lumens % Luminaire FL (0-30) 1503.6 19.8 FM (30-60) 2103.7 27.7 FH (60-80) 504.7 6.6 FVH (80-90) 49.9 0.7 BL (0-30) 1487.7 19.6 BM (30-60) 1558.4 20.5 BH (60-80) 342.9 4.5 BVH UL (80-90) (90-100) 39.2 14.5 0.5 0.2 UH (100-180) 1.7 0.0 Total 7606.3 100.0 Zonal Lumens and Percentages at 25 C Zone Lumens % Luminaire 0-10 403.2 5.3 10-20 1100 14.5 20-30 1486 19.5 30-40 1502 19.8 40-50 1234 16.2 50-60 924.2 12.2 60-70 562.4 7.4 70-80 284.9 3.7 80-90 89.1 1.2 90-100 14.5 0.2 100-110 1.7 0.0 BUG Rating: B3-U2-G1 IES Classification: Type I Longitudinal Classification: Very Short Report No. 102748333CHI-024 6 of 7 Date: February 21, 2017

PICTURES (not to scale) X CONCLUSION The results tabulated in this report are representative of the actual test samples submitted for this report only. The data is provided to the client for further evaluation. Compliance to the referenced specification requirements was not determined in this report. In Charge Of Tests: Report Reviewed By: Hector Huitron Associate Engineer Lighting Division Timothy Quigley Engineer Lighting Division Attachment: None Report No. 102748333CHI-024 7 of 7 Date: February 21, 2017