Using the GammaRAE II Personal Radiation Detector

Similar documents
Using the GammaRAE II Responder Personal Radiation Detector and Dosimeter in One. Firmware Version 3.00 D August 2006

GammaRAE II Personal Radiation Monitor User s Guide P/N Revision A, June 2005

NeutronRAE II. Intrinsically Safe Personal Radiation Monitor. User s Guide

GammaRAE II R Personal Radiation Monitor And Dosimeter User s Guide P/N Revision D, December 2010

GammaRAE II Responder. Intrinsically Safe Personal Radiation Monitor and Dosimeter. User s Guide

Personal Radiation Alarm Dosimeter LK Operating Instruction Manual. Contents

DMC 3000 Quick User s Guide

minidose A compact and colorful personal electronic dosimeter, your family can use everyday.

Controls Surface mounted pushbuttons Suitable for gloved use. Buttons Side - On/Off Front Menu Scroll Pin Hole Setup access

Detecting Radiation. Protection through Detection. February Animations in this training work best in Windows XP

MODEL 951 RADIATION DETECTOR

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

PERSONAL COMBINED RADIATION DETECTOR/DOSIMETER РМ1703МО-1 OPERATION MANUAL

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

DMC 3000 User s Guide

MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER. August 2017

User s Manual. Electronic Personal Dosimeter (For Gamma(X)-ray) NRF30. Fuji Electric Co., Ltd. TN514629i 1/31

Model R9400. Instruction Manual. CO Meter with Temperature. wwwreedinstruments. com

RAE Systems Systems. User Presentation. October Protection Through Detection

Operate the Mutli-Gas Monitor PID

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

RAM GENE-1 ERK. Contamination & Radiation Meter. Operating Manual. Document #PRIR90N2.DOC Version 2.2 October 2009

MeshGuard Gamma User s Guide

Indoor Air Quality Meter Rev. 2.x Meters. The Value Leader TM

User Guide. MeshGuard Gamma

Dosimeters/Survey meters

Ranger EXP RADIATION A L E R T

MetRad1 Handheld Metal/Gamma Detection Unit. Operation Manual. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since 1963 BNC

LUDLUM MODEL 25 AND 25-1 PERSONAL RADIATION MONITOR USER S MANUAL. October 2014 Serial Number and Succeeding Serial Numbers

Real-Time Remote Monitoring System Utilizing New Electronic Personal Dosimeter

PM1703MO-1A PM1703MO-1B PERSONAL COMBINED RADIATION DETECTOR/DOSIMETER. Operation Manual

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

RAE Systems. Using the MeshGuard. Protection Through Detection

LUDLUM MODEL 3276 SERIES FRISKER/AREA MONITOR USER S MANUAL. November 2017 Serial Number: and Succeeding Firmware: 49830n30 and Higher

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions.

Using the QRAE Plus personal multigas monitor

Mini rad-d User's Manual - February 22, 2010

Portable Alpha/Beta Continuous Online Air Monitor (CAM)

MiniRAE 3000 ppbrae Basic Operation Pocket Reference

USER MANUAL Digital CO Monitor Model CO30

TRACERCO Radiation Monitor

TRACERCO T402 and T402HR USER MANUAL

Contamination Meter Users Manual

MINI-RADIAC INTRODUCTION

RAM GENE / RAM GENE-1

UltraRAE 3000 Basic Operation Pocket Reference

IPhone: 219/

ENMET Corporation. PO Box 979 Ann Arbor, MI RECON. Manual. Manual Part Number MCN-410, 12/03/08

MODEL OX-07 Type A INSTRUCTION MANUAL FOR RIKEN PORTABLE OXYGEN MONITOR PT0E-0860

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

RIID capability in the palm of your hand

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

MiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2. , and MiniClO 2. Responder Detectors Instruction Manual "! WARNING

Radioactivity dosimeter RD01. User's Manual

Setting the new standard for personal radiation detection.

CO2 RESPONDER Portable Carbon Dioxide Detector QUICK REFERENCE GUIDE

SC-01 Operator s Manual

LUDLUM MODEL 26 FRISKER USER S MANUAL. December 2016 Serial Number PF and Succeeding Serial Numbers

Indoor/Outdoor Temperature Alert

Radiation Alert Frisker INTERNATIONAL

FLOW CONTROLLER TYPE S/601

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

TRACERCO Radiation Monitor. Instruction and Maintenance Manual for Model No. T202

User's Guide. Pinless Moisture Meter. Model MO257

Kata products Kata DGM-1500 Turva

Refrigerator/Freezer Thermometer

For the Safety of Your

RAE Systems RAE Systems RAE Systems Presented by David Lucha RAE Systems Protectio n Through Detection

LUDLUM MODEL 26-1 FRISKER USER S MANUAL. April 2017 Serial Number PF and Succeeding Serial Numbers

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)

Area Monitor/Frisker Count Rate Meter Victoreen

Portable Oxygen Monitor OX-07. (Type A) Operating Manual

NATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

GasAlertMicroClip X3 Specifications

The EGT-1 is a single channel fully programmable digital EGT (Exhaust Gas Temperature) gauge.

Refrigerator/Freezer Thermometer

Digital Cooking Thermometer models / 00282

INSTRUCTIONS FOR. Wireless Refrigerator Freezer Thermometer (#10378)

HAND HELD METAL DETECTOR

Portable type of Carbon Dioxide Detector Model: GT220

PRELIMIN INTERNATIONAL

About D-tect Systems. Personal Radiation Detector General Description of Operation. Founded in 2001 as a division of Mission Research

Aer 5200/5300. Data Sheet Aer 5200/5300. Portable Alpha/Beta Continuous Online Air Monitor (CAM) Closer to your application

Surface Contamination Monitor. Operation Manual

Ambient Weather RC-8487 ClearView Radio Controlled Travel Alarm Clock with Indoor Temperature User Manual

Bacharach Bodyguard 4 User's Guide

03 Series: OX-03, CO-03, HS-03 Versions Operator s Manual

Radiation Training for Ancillary Personnel. Introduction

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS

DMC 2000 Personal Electronic Dosimeter

RAD-60 USER GUIDE (ALSO FOR THE RAD-50 MODEL AND ISOTRAK DOSIMETERS)

User Manual. Humidity-Temperature Chart Recorder. Model RH520

SENSIT HXG-2d Combustible Gas Detector

Battery-operated, hand-held alarm and measuring instruments for radiation protection

LD-5000 REFRIGERANT LEAK DETECTOR

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

Transcription:

Using the GammaRAE II Personal Radiation Detector

GammaRAE II Features Normal Usage Turning Unit On Operating Mode User Screens Advanced Features Programming Mode Training Agenda

GammaRAE II Features Detector: CsI (TI)/Photodiode Sensitivity: More than 1 cps per µr/hr (>100 cps per µsv/hr) Dose Equivalent: 1 4000 µr/h (0.01 40 µsv/h) Rate (DER) range for 137Cs Accuracy of DER: ± 30% for 137Cs Dosage Range: 1 µr - 999 µr Energy Range: 0.06-3.0MeV

GammaRAE II Features LCD display flips for 2-way viewing Continuous digital display of dosage rate in µr/h or µsv/h (user programmable) Programmable audible, visible and/or vibration alarms Highly visible LED lights on both sides of LCD graphic display Loud alarm >85 db @ 30cm for noisy environments 2 operation/program buttons Optional Windows -compatible datalogging and set-up program

GammaRAE II Reliability Passes Drop Test from 59 (1.5m) Non-slip rubber housing with grippable ridges securely fits into hand or glove 0-100% humidity, water resistant, IP-65 rated case Temperature range of -4 o F to 122 o F (-20 o C to 50 o C) 800 hours on alkaline battery (can be changed with a coin) Rugged metal belt clip, wrist strap

MODE button for selecting mode and function Physical Description Battery Compartment Buzzer alarm SET button for setting or selecting parameters

LED alarm Physical Description LCD flips 2 ways with SET button to easily show operation parameters and radiation measurements Battery compartment cover screw

GammaRAE II Features Normal Usage Replacing Battery Turning Unit On Operating Mode User Screens Advanced Features Programming Mode Training Agenda

Replacing Battery Using either a flathead screwdriver or a coin, turn screw counterclockwise to loosen Tilt cover off to access AA batteries. Initial use may require thin, flat object to assist in removal Screw is captured in battery cover Note: Use only alkaline batteries; carbon batteries may leak causing damage.

Replacing Battery Insert new batteries according to directions on back of GammaRAE II Replace cover and turn screw clockwise to tighten Unit will beep and LEDs will flash once indicating full battery charge If alarm beeps continuously, or makes a zapping noise, the batteries are almost dead and should not be used

GammaRAE II Features Normal Usage Replacing Battery Turning Unit On Operating Mode User Screens Advanced Features Programming Mode Training Agenda

Start-up: Turning Unit On Press and hold the MODE button for 3 seconds Alarm sounds (if buzzer is set to ON) LCD displays unit information LEDs and vibrator self-test at this time Instrument performs self-check Time and battery status are displayed GammaRAE II performs a 36-second background calibration

Start-Up Warnings Important! If your GammaRAE II displays Gamma sensor not found or No sensor installed! contact your distributor or RAE Systems service at 408-752-0723. Do not attempt to use or repair the unit. There are no user-serviceable parts in the GammaRAE II.

Start-Up Once calibration is complete and the unit is in Normal Operating Mode (NORM), you will see a screen like this. Note: NORM does not mean Naturally Occurring Radioactive Material ; It indicates that the unit is in Normal Operating Mode.

Turning Unit Off Press and hold the MODE button for 5 seconds The detector counts down 5 seconds on the screen, flashes the orange LEDs, and beeps, and then shuts off Do not release the MODE button until the unit has counted down to zero, flashed the red LEDs, and sounded a long beep.

GammaRAE II Features Normal Usage Replacing battery Turning Unit on Operating Mode User Screens Advanced Features Programming Mode Training Agenda

GammaRAE II Operations The GammaRAE II has two modes of operation: Normal Operating Mode (NORM) and Programming Mode (PROG). In normal operating mode, the GammaRAE II detects Gamma radiation and accumulates radiation dosage data. In Programming Mode, operating parameters are specified.

GammaRAE II Features Normal Usage Replacing battery Turning Unit on Operating Mode User Screens Advanced Features Programming Mode Training Agenda

User Screens NORM - Normal Operation Mode CAL Background Calibration PEAK Maximum radiation level detected since last cleared MIN Minimum radiation level detected since last cleared DOSE Accumulated radiation dosage since last cleared STAT Detector status TEST Self test Each function remains active for 60 seconds before automatically returning to the normal operating mode. Pressing the MODE button moves the selection to the next one in the sequence.

Normal Operating Mode (NORM) Displays a measurement of the ambient radiation. Can operate in search mode (expressed in counts per second, cps) or detection mode (µr/h or µsv/h, depending on how the detector is set up in Programming Mode) Switch back and forth between search and detection modes by pressing the SET button. Press the MODE button to step to the next function.

Background Calibration (CAL) Background Calibration Low dosage background radiation can come from things like asphalt, higher elevations, fertilizers, and even recent hospital procedures Press the SET button to have the detector re- calibrate to the background radiation Press the MODE button to step to the next function.

Maximum Reading (PEAK) The maximum radiation level detected since last cleared Press the SET button to clear the PEAK value The PEAK value is also cleared when the detector is turned off Press the MODE button to step to the next function

Minimum Reading (MIN) The minimum radiation level detected since last cleared Press the SET button to clear the MIN value The MIN value is also cleared when the detector is turned off Press the MODE button to step to the next function

Accumulated Dose (DOSE) The accumulated radiation dosage since last cleared Press the SET button to clear the DOSE value Press the MODE button to step to the next function

Dose Rate versus Dose The speedometer tells us how many miles per hour we are traveling A dose rate meter (detector) tells us how many msv or mrem are received per hour The odometer shows how many miles the car has traveled A dosimeter show many msv or mrem one has received altogether

Why measure Dose? It makes a difference whether the high dose is received all at one time or over a long period of time. For example, a dose of 5,000 msv is usually lethal if it is received in a short period and if the patient is left without special medical care. If a person receives the same dose slowly over several months, it would may or may not cause any signs of illness. The same kind of effect could be illustrated by drinking a quart of whisky. If you drink the whole bottle at once, you will get drunk, and you may even die. If you consume it during one year, drinking one teaspoonful every day or two, it will have no effect at all. Bjorn Wahlstrom, Understanding Radiation

ICRP Standards: Important Dose Limits Exposed Workers The public Average: 20 msv or 2000 mrem per year Maximum: 50 msv or 5000 mrem per year During pregnancy: 2 msv or 200 mrem per year Average: 1 msv or 100 mrem per year Single event: 5 msv or 500mrem

Typical Radiation Doses Exposed workers Chest x-ray examination Major x-ray examination Radon gas in houses Background radiation Average 1 to 3 msv per year/100 to 300 mrem Variation range 0 to 20 msv/0 to 2000 mrem About 0.1 msv per examination/10 mrem Variation range 0.05 to 5 msv/5 mrem to 500 mrem Up to 20 msv per examination/up to 2,000 mrem Average 2 to 3 msv per year/200 to 300 mrem Variation range 0.2 to 500 msv/20 to 50,000 mrem Mostly 1 to 3 msv per year/100 to 300 mrem In extreme cases up to 20 msv/up to 2,000 mrem Construction materials in buildings 0.2 to 1 msv per year/20 to 100 mrem In the vicinity of nuclear power plants Max. permissable 0.1 per year/10 mrem Actual 0.001 to 0.01 msv/.1 to 10 mrem

Detector Status (STAT) Detector status On: Run time from when the detector was turned on (shown in hours and minutes, 0000:00) BattV: Battery voltage Temp: Internal temperature (can be displayed in C or F set in Programming Mode) Press the MODE button to step to the next function

Self Test (TEST) Self test: This consists of tests to make sure all alert functions are working properly. 1. Press the SET button to accept and to initiate testing. 2. The buzzer is tested. Press the SET button to start the next test. 3. The vibrator is tested. Press the SET button to start the next test.

Self Test (TEST) 4. The LED is tested. Press the SET button to start the next test. 5. The backlight is tested. Press the SET button to start the next test. 6. The alarm buzzer is tested. Press the SET button to finish the TEST functions. This returns GammaRAE II to Normal Operating Mode.

GammaRAE II Features Normal Usage Replacing battery Turning Unit on Operating Mode User Screens Advanced Features Programming Mode Training Agenda

Programming Mode (PROG) Programming Mode is used to change alarm settings and detector settings Hold the MODE and SET buttons for 3 seconds to enter into Programming Mode Press the MODE button to step through the menu Press the SET button to select

Programming Mode (PROG) Alarm Set allows you to reset the alarm setpoints (CF) Datalog Set Monitor Set allows you to reconfigure the parameters of the GammaRAE II

Alarm Set Select Alarm Set to set the low detection limit for the alarm The Gamma CF is used to set Low Alarm = CF*σbk σbk = (standard deviation of background) this is the same as the n in the GammaRAE pager Press the MODE button to step through the digits from left to right Note: The default value is 5.0 Use the SET button to increment each digit (from 0 through 9)

Alarm Set The alarm is not a fixed value, but a % above background Smaller CF" increases the alarm sensitivity Small CF is like no squelch and large CF is like full squelch Alarm threshold value (alarm point): Alarm = B + CF x D B = background radiation reading (from CAL ). It is the average reading of every 0.25 second in 36 seconds CF = number of the deviations to trigger the alarm. Can be set from 1.0 to 9.9 D = mean square deviation of background radiation (from CAL ). The statistical difference of all of the 0.25 second readings for 36 seconds

Alarm Set Example: At a background reading of 15 μr/h CF 1 2 3 4 5 6 7 Alarm % Above Background 15% 30% 45% 60% 75% 90% 105% Alarm Threshold Value 17 μr/h 20 μr/h 22 μr/h 24 μr/h 26 μr/h 29 μr/h 31 μr/h Probability of False Alarm 16.6% 2.6% 0.2% 0.01% <0.01% <0.01% <0.01%

Alarm Set To exit Alarm Set, step through the options using the MODE button until you see Quit Press the SET button to exit Alarm Set Then step through the Main Menu until you see Quit Press SET to exit Program mode and return to Normal Operating Mode

Monitor Set Select Monitor Set to change any of the following parameters: Back Lite Default setting: Manual Buzz & Lite Default setting: Both On Vibrate Default setting: On Temp Unit Default setting: Celsius Gamma Unit Default setting: µr/h Change Date Change Time Press the MODE button to scroll down these menu options Select an option using the SET button

Monitor Set Back Lite Set the behavior of the display backlight Automatic A photosensor turns on the light in dim lighting Manual Turn on by pressing MODE Off Buzz & Lite Set the behavior of the audible and visible alarms Both on LEDs light and buzzer sounds when in alarm Light only Only LEDs light when in alarm Both off Vibrate Mode Set the vibration alarm On Off WARNING: You can turn all three of the alarm alerts (Buzzer, LEDs & Vibrator) OFF at the same time!!!!

Temp Unit Set the unit of measure Choices are Fahrenheit and Celsius Press MODE to select Fahrenheit or Celsius Then press SET to save your choice and exit

Gamma Unit Set the unit of measure (of radiation). Choices are µr/h (US) or µsv/h (SI Unit) 100 μr/h = 1 μsv/h Press MODE to select unit Press SET to save your choice and exit

Change Date Set the date (mm/dd/yyyy). Press MODE to step through month, date, and year, and press SET to increment through the digits (holding the SET button speeds through the numbers) Press MODE to select Save and press SET to save your date changes and exit Otherwise, press MODE again to select Quit and press SET to exit.

Change Time Set the time (hh:mm:ss) Press MODE to step through hours, minutes, and seconds, and press SET to increment through the digits (holding the SET button continuously speeds through the numbers). Press MODE to select Save and press SET to save your time changes and exit Otherwise, press MODE again to select Quit and press SET to exit.

Questions? RAE Systems 3775 North First Street San Jose, CA 5134 Voice: 408-952-8200 Fax: 408-952-8480 www.raesystems.com elang@raesystems.com