Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

Similar documents
SENSORS. Vacancy Sensors. Occupancy Sensors A4-A7 A-1

Never forget to turn the lights off again. Motion Sensors

Technology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2

Mini Product Guide.

CS1200 WHT Pir Ceiling Mount Occupancy Sensor

Table of Contents. Fast Fact. Sensor Models 2 Advantages of Sensors 3 FAQs 4-5

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

Lighting Control Strategies. to meet code requirements save energy and improve building performance

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

Versatile wall switch sensors maximize payback and simplify code compliance

Dual Relay Multi-Technology Wall Switch Occupancy Sensors

HUNTERSVILLE, NORTH CAROLINA USA EFFECTIVE SEPTEMBER 1, 2004

FROM THE WORLD S FIRST GFCI RECEPTACLE TO OUR GAME-CHANGING LINE OF PASS & SEYMOUR PLUGTAIL DEVICES, PASS & SEYMOUR PRODUCTS HAVE A REPUTATION FOR

2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F E. cristalcontrols.

ENERGY EFFICIENCY EXPERTS

Lighting and Fan Speed Controls

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Wireless Plug Load Control

0ACDT2000MV Ultasonic/Infared Occ Sensor

IN2 Lighting Control Devices

The Power To Supply... All Your Electrical Products

DIMMING WASP Occupancy and Daylight Sensor

H-MoSS. Tomorrow s Technology Today! H-MOSS Occupancy and Vacancy Sensors. Adaptive Technology Dual Technology Ultrasonic Passive Infrared

Shannon J Markey LC, LEED AP Legrand BCS / Wattstopper Western Regional Manager. Yesterday, Today & Tomorrow

Residential Occupancy & Vacancy Sensors

The Power To Supply... All Your Electrical Products

LIGHTING CONTROLS

MANDATORY MEASURES MANDATORY LIGHTING CONTROLS (a) Area Controls: Manual controls that control lighting in each area separately

SECTION. Occupancy Sensors & Lighting Control Products

Installation Instructions

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

Code Review TITLE PRESENTED BY POURIA NIKNAM

Interior Control Solutions

Lighting Controls. Energy-Saving Solutions For Efficient Buildings

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

Product Specifications Dialog Room Controller* (*patent pending)

Ever evolving energy code requirements and the large demand for energy

Installation Instructions

Movement-based energy control

Retrofit Solutions NEW. Energy-saving products for single rooms. Lutron energy-saving products. Patient Rooms. Office Spaces. Affordable Solutions

Sensors and Timers P&S. designed to be better. A COMPLETE LINE FOR ENERGY SAVINGS AND CONVENIENCE.

Sensors and Detectors

Maestro 0 10 V Dimmer Sensor

Reduce lighting energy costs with controls

SECTION LIGHTING CONTROL DEVICES AND CONTROL PANELS

Here we see the list of auto shutoff controls we will cover in the next few slides

Energy Management Products

LS-CM Series. Overview. Applications. Features & Benefits. Datasheet. Ceiling mount occupancy sensors

EL7611A/EL7612A Ultrasonic Occupancy Sensors and EL7621A Power Pack PRODUCT DATA

CONTENTS SENSOR SWITCH

A. This Section includes the following lighting control devices:

National Grid Small Business Program Rebate Manual

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Infrared Wall Mount Occupancy Sensor

POWER YOUR ENERGY EFFICIENCY PROGRAMS. with proven lighting controls. designed to be better.

Specifications Occupancy/Vacancy Sensors CSI ASHRAE AIA Division 16 Section 16950

Princeton Joint Unified School District Invitation for Bid Installation of District-Wide Lighting Occupancy Sensors

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

Maestro Dual-Circuit Occupancy Sensing Switch

Sensor Product Guide. Smart Sensing Control Solutions

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels

FR-A180 FR-A360. Occupancy detector. Use

LIGHTING CONTROL DEVICES

PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor

LPCMPIRM65 & LPCMPIRDSI65

SECTION 26 NX DISTRIBUTED INTELLIGENCE LIGHTING CONTROL SYSTEM HUBBELL CONTROL SOLUTIONS

IP65 High Bay Dual Sense Sensor

East Central College

AHAC-DT MicroSet dual tech low/line voltage ceiling sensors

, ,

Wherever the best is needed. Sensors for professionals.

ADDENDUM NO. 2 COOK LIBRARY BATHROOM RENOVATIONS PROJECT NUMBER TU-1874-SBR

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)

A. This Section includes the following lighting control devices:

Integrated PIR detectors

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Supporting the Requirements of EPAct 2005 Tax Deductions

SECTION LIGHTING CONTROLS

Maestro Occupancy Sensing Switch

Lutron Sensor Solutions. Lutron energy-saving light controls for your home or office. simple. affordable. energy-saving.

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Tualatin Valley Fire & Rescue Finance Department SW 70 th Ave., Tigard, OR Phone: , Fax:

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

DIVISION 26 ELECTRICAL SECTION LIGHTING CONTROL SYSTEM

Advances in Non-Residential Lighting Technologies

Dissecting Lighting Control Requirements ANSI/ASHRAE/IES Standard & 2013

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

A Simpler and Smarter Wireless Lighting Control Solution. Design & Application Guide

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

IP65 High Bay Dual Sense Sensor

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

Applied Lighting Controls

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Lighting Summary - Interior

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130)

F series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC

Honeywell ENERGY SAVINGS KIT

Transcription:

Occupancy and Vacancy Sensors ENERLITES offers a wide variety of lighting sensors. They are designed to bring convenience to your life and business while helping to reduce energy consumption in commercial, residential, and industrial applications. Occupancy and Vacancy Sensors Ceiling Mount Sensors Occupancy and Vacancy Sensors Wall Mount Occupancy Sensors 4-9 10-15 16-17 -1

Occupancy and Vacancy Sensors Lighting controls have traditionally been used to control the intensity of lighting within a space and allow the atmosphere of the room to be adjusted to the user s desires. Over the last decade, occupancy sensors have been designed into control systems that control a wide variety of areas in residential, commercial and industrial buildings. These applications consist of individually enclosed offices, large open work spaces, conference rooms, hallways, storage closets and more. Overall, occupancy sensors together with built-in photocell technology have been proven to reduce lighting related energy consumption up to 45 percent depending on application. Currently, modern building designs are integrating electric light sources with natural light that penetrates the room through strategically placed windows. This enables the building owner to incorporate motion and photo controls to automatically adjust the electric lighting to a lower level and takes advantage of the natural light entering the space. The overall goal is to provide a comfortable and well-illuminated space for the user while reducing energy consumption and saving electricity. Although occupancy sensors are most commonly used in commercial buildings, they are now being applied to residential homes in the form of a vacancy sensor. These types of sensors provide the manual ON function, but automatically turn the connected lighting OFF when the room becomes vacant. Residential applications that benefit from this type of control are generally bedrooms, bathrooms, laundry rooms, closets, and garages where lighting is often left on after occupancy. With multi-level wiring, installing occupancy/vacancy sensors in residential, commercial and industrial buildings can reduce lighing energy consumption significantly. Enerlites sensors are of the highest quality for energy management and conservation. Our occupancy/vacancy sensors are place in residential, commercial or industrial buildings and can reduce lighting energy consumption significantly. Green/Energy/Low-Carbon/Environment -2

The table below provides control ideas for several different room types and usage patterns. Space Type Use Pattern If... Then... Cafeteria or Occasionally Occupied occasionally Consider ceiling mount occupancy sensor(s). Make sure Lunch Room occupied minor motion will be detected in all desired locations. Classroom Usually occupied Occupied by different students and teachers Lights are left on after hours Consider ceiling or wall mount occupancy sensor(s) and manual dimming. Make sure that minor motion will be detected. Consider centralized controls and/or occupancy sensor(s). Computer Usually Lights are left on all Consider occupancy sensor(s) with manual dimming. e Room unoccupied the time sure that minor motion will be detected and that equipment vibration will not falsely trigger the sensor. Conference Occasionally Small conference room Consider an in-wall occupancy sensor. Room occupied Large conference room Consider ceiling or wall mount occupancy sensor(s). e sure that minor motion will be detected in all desired locations. Hallway Any Occasionally or usually occupied Consider occupancy sensor(s) with elongated throw. e sure that coverage does not extend beyond the desired area. Health Care- Occasionally Small area Consider an in-wall occupancy sensor. Examination occupied Room Laboratory Usually occupied Windows are present Consider automatic daylight driven dimming in combination with occupancy sensor(s). Laundry Room Occasionally Requires high light levels, Consider occupancy sensor(s). occupied yet lights are usually left on Libraries-Stack Occasionally Aisles are usually Consider ceiling mount sensor(s). Area occupied unoccupied Lobby / Hotel Usually occupied Lights are left on all night Consider occupancy sensor(s). e sure that minor motion but no one "owns" long, even when no one is will be detected in all desired areas. the space in the area for long periods Office, Open Usually occupied Lights are left on after hours Consider centralized controls and/or occupancy sensor(s). Office, Private Primarily one Windows are present Consider manual dimming, automatic daylight driven person, coming dimming, or automatic on/off. and going Occupants are likely to leave Consider an in-wall occupancy sensor. lights on and occupants would be in direct view of a wall box sensor Occupants are likely to leave Consider a ceiling or wall mount occupancy sensor(s). lights on and partitions or objects could hide an occupant from the sensor Restroom Any Has stalls Consider a ceiling mount ultrasonic occupancy sensor for full coverage. Usually occupied Single toilet (no partitions) Consider an in-wall occupancy sensor. Warehouse Aisles are usually Lights in an aisle can be Consider high bay fixture mount occupancy sensor(s) with unoccupied turned off when the aisle elongated throw. Select a sensor that will not detect motion in is unoccupied neighboring aisles, even when shelves are lightly loaded. -3

Ceiling Mount Sensors Combines passive infrared and ultrasonic technologies Simple and fast installation Adjustable time delay 360 Fresnel lens for superior occupancy detection 360 Dual-Technology PIR/Ultrasonic Occupancy Sensor DESCRIPTION CAT. NO. RATING Dual-Technology PIR/Ultrasonic Low Voltage Occupancy Sensor Requires MPP-24 Power Pack MDC-50L Voltage: 24 VDC Current Consumption: 20 ma 360 PIR Coverage 1600 sq. ft. Ultrasonic Coverage 1000 sq. ft. MDC-50L Specification: - Input Voltage: 24 VDC - Power Supply by MPP-24 and control line load through MPP-24 - Operating Temperature: 32 F to 131 F (0 C to 55 C) - Adjustable Light Level: 10FC-150FC - Adjustable Time Delay: 5 sec/autoset to 30 min MPP-24 CAT. NO. MPP-24 DESCRIPTION Power pack: 120/230/277 VAC, 50/60 Hz, 150 ma @ 24 VDC MPP-24 power packs supplies power for up to 6 MDC-50L sensors Specification: - Power Input: 120/230/277 VAC, 50/60 Hz - allast: 20 Amp @ 120/277 VAC Incandescent: 20 Amp @ 120 VAC Motor: 1 HP @ 120/240 VAC - Power Supply Output: 150 ma @ 24 VDC (with relay connected) MPP-24 Ultrasonic Radius of 18' (or 36' Diameter) PIR Radius of 22' (or 44' Diameter) MDC-50L at 9' high -4

Ceiling Mount Sensors Combines passive infrared and ultrasonic technologies Simple and fast installation Adjustable time delay 360 Fresnel lens for superior occupancy detection 360 Line Voltage Ceiling Sensor (Power Pack not required) DESCRIPTION CAT. NO. RATING Dual-Technology MDC-50V Incandescent: 800 W @ 120 VAC 360 PIR Coverage PIR/Ultrasonic Fluorescent: 800 VA @ 120 VAC 1600 sq. ft. Line Voltage 1600 VA @ 277 VAC Ultrasonic Coverage Occupancy Sensor Motor: 1/4 HP @ 120 VAC 1000 sq. ft. Specification: - Input Voltage: 120/277 VAC - Operating Temperature: 32 F to 131 F (0 C to 55 C) - Adjustable Light Level: 10FC-150FC - Adjustable Time Delay: 15 sec - 30 min - Sensitivity Adjustment: 50% or 100% - Load Ratings: Incandescent: 800 W @ 120 VAC, 60 Hz Fluorescent: 800 VA @ 120 VAC/1600 VA @ 277 VAC, 60 Hz Resistive: 800 W @ 120 VAC, 60 Hz Motor: 1/4 HP, 120 VAC, 60 Hz MDC-50V Ultrasonic Radius of 18' (or 36' Diameter) PIR Radius of 22' (or 44' Diameter) MDC-50V at 9' high -5

Ceiling Mount Sensors Passive infrared technology (PIR) 360 field of view,1200 sq. ft. Simple and fast installation Adjustable time delay 360 Fresnel lens for superior occupancy detection Vacancy override feature, turn lights on manually and turn lights off automatically 360 Low Voltage Ceiling Sensor DESCRIPTION CAT. NO. RATING PIR Occupancy Sensor, MPC-50L Voltage: 24 VDC 360, Low Voltage, Current up to 1200 sq. ft. Requires MPP-24 Consumption: 9 ma Power Pack Light Level Sensor MPC-50L Specification: - Input Voltage: 24 VDC - Power Supply by MPP-24 and control line load through MPP-24 - Operating Temperature: 32 F to 131 F (0 C to 55 C) - Adjustable Light Level: 10FC-150FC - Adjustable Time Delay: 5 sec - 30 min - Walk-Through Mode: 3 minutes if no activity after 30 sec. Installation Option: MPC-A Ceiling Sensor Adapter allows you to mount ceiling sensor onto the mud ring for several types of boxes, such as 4 or 5 junction box. MPP-24 power packs supply power for up to 6 MPC-50L sensors. MPC-A MPP-24 Radius of 22' MPC-50L at 8' high -6

Ceiling Mount Sensors Passive infrared technology (PIR) 360 field of view, 1200 sq. ft. Simple and fast installation Adjustable time delay and light level. 360 Fresnel lens for superior occupancy detection Vacancy override by using momentary switch (optional) 360 Line Voltage Ceiling Sensor (Power Pack not required) DESCRIPTION CAT. NO. RATING PIR Occupancy MPC-50V Incandescent: 800 W @ 120 VAC 360, Sensor, Fluorescent: 800 VA @ 120 VAC up to 1200 sq. ft. Line Voltage, 1600 VA @ 277 VAC Light Level Sensor Motor: 1/4 HP @ 120 VAC The MPC-50V 360 passive infrared (PIR) occupancy sensor turns lighting systems on and off based on occupancy and ambient light levels. The light level feature keeps lights from turning on if the ambient light level is sufficient. The sensors can be configured to turn lighting on, and hold it on as long as the sensor detects occupancy. After no movement is detected for a specified amount of time, the lights are switched off. Specification: - Input Voltage: 120/277 VAC - Operating Temperature: 32 F to 131 F (0 C to 55 C) - Adjustable Light Level: 10FC-150FC - Adjustable Time Delay: 15 sec - 30 min - Sensitivity Adjustment: 50% or 100% - Load Ratings: Incandescent: 800 W @ 120 VAC, 60 Hz Fluorescent: 800 VA @ 120 VAC/1600 VA @ 277 VAC, 60 Hz Resistive: 800 W @ 120 VAC, 60 Hz Motor: 1/4 HP, 120 VAC, 60 Hz MPC-50V Installation Option: MPC-A Ceiling Sensor Adapter allows you to mount ceiling sensor onto the mud ring for several types of boxes, such as 4 or 5 junction box. MPC-A Radius of 22' MPC-50V at 8' high -7

Fixture Mount Sensors Passive infrared technology (PIR) 360 field of view, up to 2800 sq. ft Simple and fast installation Adjustable time delay and light level 360 Fresnel lens for superior occupancy detection High ay Ceiling Sensor (Power Pack not required) DESCRIPTION CAT. NO. RATING High ay PIR MPC-50H Incandescent: 800 W @ 120 VAC 360, Occupancy Sensor Fluorescent: 800 VA @ 120 VAC MPC-50H - L1: 2800 sq. ft. Fixture Mount, 1200 VA @ 277 VAC MPC-50H - L2: 1200 sq. ft. Line Voltage Motor: 1/4 HP @ 120 VAC Light Level Sensor MPC-50H Specification: - Input Voltage: 120/277 VAC, 50/60 Hz - Operating Temperature: 32 F to 131 F (0 C to 55 C) - Adjustable Time Delay: 15 sec - 30 min - Sensitivity Adjustment: 50% or 100% - Load Ratings: Incandescent/Tungsten: 800 W @ 120VAC, 50/60 Hz Fluorescent/allast: 800 VA @ 120 VAC/1200 VA @ 277 VAC, 50/60 Hz Motor: 1/4 HP, 120 VAC - No minimum load required - Two lens L1: 15-50 ft, L2: 8-12 ft Figure 1 Lens 1 at Max 50' high L2 22' Radius MPC-50H 30' Radius Lens 2 at 8' high L1-8

Ceiling Mount Sensors Passive infrared technology (PIR) 360 field of view, 800 sq. ft. Simple and fast installation Adjustable time delay and light level 360 Fresnel lens for superior occupancy detection Small cutting and no junction box required 4 feet feeding cables for convenient installation uilt-in half inch flex EMT fitting Line Voltage Ceiling Sensor (Power Pack not required) DESCRIPTION CAT. NO. RATING PIR Occupancy MPC-52V Incandescent: 800 W @ 120 VAC 360, Sensor, Fluorescent: 800 VA @ 120 VAC up to 800 sq. ft. Line Voltage, 1200 VA @ 277 VAC Light Level Sensor Motor: 1/4 HP @ 120 VAC 4 ft. lead cable Specification - Input Voltage: 120/277 VAC - Operating Temperature: 32 F to 131 F (0 C to 55 C) - Adjustable Light Level: 10FC - 150FC - Adjustable Time Delay: 15 sec - 30 min - Sensitivity Adjustment: 50% or 100% - Load Rating: Incandescent: 800 W @ 120 VAC, 60 Hz Fluorescent: 800 VA @ 120 VAC/ 1200 VA @ 277 VAC, 60 Hz Motor: 1/4 HP, 120 VAC, 60 Hz MPC-52V PIR Radius of 22' (or 44' Diameter) MPC-52V at 8' high MPC-52V -9

Humidity Sensors 1/4th HP (3-AMP) fan Time Delay: 10, 20, and 30 minutes Humidity Set Point: 45%-80% relative humidity Compatible with incandescent, fluorescent, halogen, and LED lighting Neutral wire required Interchangeable faceplate Dual-Technology Humidity/PIR Motion Sensor DESCRIPTION CAT. NO. RATING DWHOS 1/4th HP(3-AMP) fan PIR coverage: 120VAC 60Hz Time Delay: 10, 20, and 30 600 sq. ft. lack Neutral wire and minutes Light Almond two separate Humidity Set Point: 45%-80% loads required relative humidity Interchangeable faceplate also available in black and light almond. Sold separately DWHOS This is the first of its kind, and is the only dual-technology humidity and PIR vacancy sensor on the market today. This device continuously monitors the humidity level in a room to automatically turn on and off the exhaust fan as needed. At the same time, the passive infrared technology (PIR) sensor detects motion and automatically turns off the lights when the room is vacant. This allows the consumer to save money and conserve energy. Contractors, builders, and specifiers are quickly falling in love with this device, because it takes half the installation time as traditional humidity and vacancy sensors, only requires a one-gang box, and is lower cost than any combination of our competitors' humidity and vacancy sensors. The DWHOS has several great features including programmable functions such as timers, humidity settings, and ambient light level adjustments. It s easy to install and comes with easy to follow instructions. This device looks great and will complement all of your architectural settings. Detection Range Max. 12' on the sides Max.24' from front Installation Height: 4' - 5' -10

Occupancy/Vacancy Sensors OCC/VAC modes available Adjustable time delay 15 seconds to 30 minutes No neutral wire required (secure ground required) Single pole feed & single output Zero crossing function Compatible with all kinds of loads including electronic ballast Controls incandescent, CFL, and LED lighting Standard decorator wall plate included Five year warranty Decorator Passive Infrared Wall Switch Occupancy Sensors DESCRIPTION CAT. NO. RATING OCC/VAC (2-in-1) Decorator Wall Switch secured ground wire required DWOS-J Incandescent: 800 W @ 120 VAC Fluorescent: 800 VA @ 120 VAC 1600 VA @ 277 VAC Motor: 1/4 HP @ 120 VAC 1200 sq. ft. OCC/VAC (2-in-1) Decorator Wall Switch with Dual Relay secured ground wire required DWOS-JD Incandescent: 800 W @ 120 VAC Fluorescent: 800 VA @ 120 VAC 1600 VA @ 277 VAC Motor: 1/4 HP @ 120 VAC 1200 sq. ft. DWOS-J * Dual Relays: Control two separate loads; bi-level wiring with VAC and OCC mode Detection Range Max. 20' on the sides Max. 30' from front Installation Height: 4' - 5' est: 320 sq. ft. Regular: 800 sq. ft. Maximum: 1200 sq. ft. DWOS-JD -11

Occupancy/Vacancy Sensors OCC/VAC Modes available Adjustable time delay 15 seconds to 30 minutes Single pole feed & single output Zero crossing function Adjustable sensitivity settings Standard decorator wall plate included Controls incandescent, CFL, and LED lighting Five year warranty Decorator Passive Infrared Wall Switch Occupancy Sensors DESCRIPTION CAT. NO. RATING DWOS-1277 Incandescent: 800 W @ 120 VAC OCC/VAC (2-in-1) Fluorescent: 800 VA @ 120 VAC 1200 sq. ft. Decorator Wall Switch 1600 VA @ 277 VAC neutral wire required Motor:1/4 HP @ 120 VAC DWOS-1277-NL Incandescent: 800 W @ 120 VAC OCC/VAC (2-in-1) Fluorescent: 800 VA @ 120 VAC 1200 sq. ft. uilt-in Night light 1600 VA @ 277 VAC Decorator Wall Switch Motor:1/4 HP @ 120 VAC neutral wire required DWOS-1277 /3-Way OCC/VAC (2-in-1) DWOS-3J Incandescent: 800 W @ 120 VAC Fluorescent: 800 VA @ 120 VAC 1200 sq. ft. Decorator Wall Switch Motor:1/4 HP @ 120 VAC secured ground wire required Detection Range Max. 20' on the sides Max. 30' from front Installation Height: 4' - 5' DWOS-1277-NL est: 320 sq. ft. Regular: 800 sq. ft. Maximum: 1200 sq. ft. -12

Occupancy/Vacancy Sensors Combines passive infrared and ultrasonic technologies Adjustable time delay 15 seconds to 30 minutes OCC/VAC modes available Walk-through sensing mode increases energy savings by turning lights Off shortly after momentary occupancy Adjustable time delay, light level, ultrasonic and PIR sensitivity Single pole feed & single output Controls incandescent, CFL, and LED lighting Five year warranty Multi-Technology Wall Switch Occupancy Sensor DESCRIPTION CAT. NO. RATING MWOS Incandescent: 800 W @ 120 VAC PIR coverage: OCC/VAC (2-in-1) Fluorescent: 800 VA @ 120 VAC 1200 sq. ft. Sensor Switch PIR/Ultrasonic 1600 VA @ 277 VAC Motor: 1/4 HP @ 120 VAC Ultrasonic: 400 sq. ft. Dual Technology neutral wire required Ultrasonic motion detection gives maximum sensitivity yet can be vulnerable to false triggering from air conditioning current, corridor activity, and movement of inanimate objects. Infrared motion sensing gives immunity to false triggering, but lacks sensitivity at greater distances. Our multi-technology sensors combine the benefits of both infrared and ultrasonic technologies for unrivaled performance and reliability. MWOS They provide for automatic switching of incandescent lamps, low-voltage lighting with electronic and magnetic transformers, and electronic and magnetic fluorescent ballasts. Detection Range Ultrasonic: max. 40' in front and 20' on sides PIR: max. 40' in front and 20' on sides Installation Height: 4' - 5' -13

Occupancy/Vacancy Sensors High sensitivity and dense coverage for exceptional performance Smart night light feature turns off to prevent disturbance and turns on when movement is detected in Vacancy mode Defaults to Manual-ON operation for maximum energy savings Color-matched lens and low profile for appealing design Interchangeable cover feature Occupancy Sensor Switch DESCRIPTION CAT. NO. RATING OCC/VAC (2-in-1) Sensor Switch neutral wire required HMOS Incandescent: 500 W @ 120 VAC Fluorescent: 500 VA @ 120 VAC Motor:1/8 HP @ 120 VAC 700 sq. ft. lack Light Almond OCC/VAC (2-in-1) Sensor Switch secured ground wire required HMOS-J Incandescent: 500 W @ 120 VAC Fluorescent: 500 VA @ 120 VAC 1000 VA@277 VAC Motor: 1/8 HP @ 120 VAC 700 sq. ft. lack Light Almond HMOS Vacancy Sensor Switch DESCRIPTION CAT. NO. RATING Vacancy Only Sensor Switch neutral wire required HMVS Incandescent: 500 W @ 120 VAC Fluorescent: 500 VA @ 120 VAC Motor: 1/8 HP @ 120 VAC 700 sq. ft. lack Light Almond Vacancy Only Sensor Switch secured ground wire required HMVS-J Incandescent: 500 W @ 120 VAC Fluorescent: 500 VA @ 120 VAC 1000 VA @ 277 VAC Motor: 1/8 HP @ 120 VAC 700 sq. ft. lack Light Almond Detection Range max. 12' on the sides max. 30' from front Installation Height: 4' - 5' est: 180 sq. ft. Regular: 450 sq. ft. Maximum: 700 sq. ft. -14

Wall Mount Occupancy Sensors Easy installation and energy-saving PIR Technology Turns lighting systems on/off based on occupancy and ambient light levels Adjustable sensitivity and light level Adjustable time delay 15 seconds to 30 minutes Passive Infrared Occupancy Sensor DESCRIPTION CAT. NO. RATING, MPW-V 120/277 VAC, 50/60 Hz 150, Passive Infrared Max load: 10 A 1000 sq. ft. Line Voltage Occupancy Sensor, MPW-J 120/277 VAC, 50/60 Hz 150, Passive Infrared Max load: 10 A 1000 sq. ft. Line Voltage Occupancy Sensor secured ground wire required, MPW-L Voltage: 22-26 VDC 150, MPW-V Passive Infrared 1000 sq. ft. Low Voltage Occupancy Sensor MPP-24 Power Pack Required PIR coverage 50ft MPW-J 10 ft 0 7 ft 15 ft 25 ft 50 ft -15

Wall Mount Occupancy Sensors Easy installation and energy-saving Combines PIR and Ultrasonic Technologies to avoid false triggering Turn lighting systems on /off based on occupancy and ambient light levels Combines numerous operating modes to create an ideal custom control Walk-through mode can turn lights off after only 3 minutes, if no activity is detected after 30 seconds following occupancy detection Dual Technology Occupancy Sensors DESCRIPTION CAT. NO. RATING, Dual MDW-V 120/277 VAC, 50/60 Hz PIR coverage: Technology Line Voltage Max load: 10 A 1000 sq. ft. Occupancy Sensor Ultrasonic: 800-1200 sq. ft., Dual MDW-L Voltage: 22-26 VDC PIR coverage: Technology Low Voltage 1000 sq. ft. Occupancy Sensor Ultrasonic: MPP-24 Power Pack 800-1200 sq. ft. Required MDW-V PIR coverage 50ft Ultrasonic coverage 30ft MDW-L 10 ft 0 7 ft 15 ft 25 ft 50 ft -16