APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

Similar documents
APPLIED. OMA-406R Rackmount Process Analyzer

OMA-300 Process Analyzer

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

Features and Benefits

An FT-NIR Primer. NR800-A-006

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

Xi Advanced Electronics for Zirconium Oxide Oxygen Probes

Specifications Wavelength Range: 190 nm to 800 nm continuous

detectors UltiMate 3000 Variable Wavelength Detectors

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

Features and Benefits

Xi Advanced Electronics for Zirconium Oxide Oxygen Probes

PUV, PIR and PFO Series BROCHURE

Enraf Servo Gauge 854 ATG

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

Accurate, cost-saving and reliable Natural gas analyzer SITRANS CV SITRANS CV. Answers for industry.

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

Enraf Servo Gauge 854 XTG

The SharpEye 40/40I (IR3) Flame Detection

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Dräger PointGard 2100 Detection of toxic gases and vapours

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

Dräger REGARD 3900 Series Control System

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

WASTEWATER Online UV%Transmission Analyzer

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

Autocalibration Systems for In Situ Oxygen Analyzers

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Effluent Monitoring. Solutions

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

818 Series. Low-Power Detectors ABSOLUTE SPECTRAL RESPONSIVITY (A/W)

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Ronan Model X96S Series Weighing System

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage.

Technical Information OUSAF12

The SharpEye 40/40M (Multi IR) Flame Detection

818 Series Low-Power Detectors

FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS.

Eliminating False Alarms in Toxic Gas Detection. Jason Schexnayder Sales Manager - Americas

Low-Power Detectors. Key Features. 818 Series. Power levels from pw to 2W. Wavelengths from 190 nm to 1800 nm. Proprietary detector optics

Industrial Grade Gas Detection

Dräger REGARD -1 Control System

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

for Drinking Water Systems

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

Industrial Grade Gas Detection

Dräger REGARD -1 Control System

New Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer.

Dräger Polytron 7000 Detection of toxic gases and oxygen

4500MkIII COMPLIANCE OPACITY AND DUST MONITORING QAL 1 PS-1 ASTM D6216 PROCEDURE 3 PS-11 QUALITY CUSTOMER SOLUTIONS

APPLICATION DATA SHEET

Honeywell Analytics is pleased to announce the release of Version firmware software for the SPM Flex TM product line.

Diode Array Spectroscopy

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001

The SharpEye 40/40L4-L4B (UV/IR) Flame Detection

Pre-engineered Sample Systems for TALYS ASP400 series with fiber optic interface

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

Process Gas Chromatograph

Dräger Polytron 8310 Stationary gas detector (DSIR)

POSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING

InfraSpec NR800. FT-NIR Analyzer. Bulletin12Y03A03-01E

NanoReady. Micro UV-Vis Spectrophotometer

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

operational excellence Solutions for

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP

ADPRO PRO Series by Xtralis

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.

IR 3000 WBPi Online Moisture Measurement with Infrared Technology

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards

The SharpEye 40/40I (IR3) Flame Detection

Open-area Smoke Imaging Detector. Engineering Specification

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

Dräger GS01 (wireless) Detection of flammable gases and vapours

Ronan Model X96S Series Density System

Temperature controllers TW, TO and TP, Speedy Therm

Turbimax CUE21 / CUE22

Dräger Polytron 5100 EC Detection of toxic gases and vapors

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

Technical Information OUSAF21

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

LABTRON LAAS - Series Atomic Absorption Spectrophotometer

SAM-MAX Refrigerant Monitors

Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments

in mobility Gentle & precise cleaning of sensitive Very quiet air-cooled system Large operating distance (up to 250 mm) Laser class 4 product

Technical Information OUSAF22

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Partners in Process Automation with Emerson Process Management for Intrinsic Safety

PG 990 Atomic Absorption

APPLICATION DATA SHEET

Dräger Polytron 8000 Stationary gas detector (EC)

Transcription:

A window into your process since 1994. The OMA Process Analyzer continuously measures chemical concentrations and physical properties that can be correlated from the 200-1100 nm (UV-Vis / SW-NIR) absorbance spectrum. Model OMA-206P deploys the OMA design in a highly portable, rugged suitcase enclosure. Features Continuously measures up to 5 chemicals concentrations in a liquid or gas process stream Suitcase enclosure made from Ultra High Impact structuraly copolymer for rugged portability Totally solid state build with no moving parts modern design for low maintenance Decades of field-proven performance in the world s harshest industrial environments APPLIED TM A N A L Y T I C S [1]

Optical Assembly & Principle of Operation light source holographic grating fiber optic cables flow cell diode array o-ring collimator The OMA measurement cycle is virtually instantaneous, but it can be helpful to visualize it in stages: (1) The white light signal originates in the pulsed Xe lamp that functions as the light source. (2) The signal travels via fiber optic cable to the flow cell. A collimator narrows the light beam. (3) The signal travels directly across the flow cell, interacting with the continuously drawn process sample. (4) The signal exits the flow cell through a collimator, now containing the distinct absorbance imprint of the current chemical composition of the sample. (5) The signal travels via fiber optic cable to the spectrophotometer. (6) The signal is dispersed by the holographic grating. Each differentiated wavelength is focused onto a designated photodiode within the diode array. (7) The absorbance spectrum is measured by plotting the lost light intensity at each wavelength: Normalized Light Intensity Spectrum Visualized Absorbance Spectrum (1% H 2 S) light intensity Thru N 2 Thru 1% H 2 S >> absorbance (AU) 1.4 1.0 0.6 0.2 215 225 235 245 255 wavelength (nm) 215 225 235 245 255 wavelength (nm) [2]

OMA-206P Technical Drawing [3]

All performance specifications are subject to the assumption that the sample conditioning system and unit installation are approved by Applied Analytics. For any other arrangement, please inquire directly with Sales. Subject to modifications. Specified product characteristics and technical data do not serve as guarantee declarations. Technical Data General Measurement Principle Detector Spectral Range Light Source Dispersive UV-Vis / SW-NIR absorbance spectrophotometry nova II Spectrophotometer Data sheet: http://aai.solutions/documents/aa_ds201a_novaii.pdf 200-800 nm (UV-Vis model) or 400-1100 nm (SW-NIR model) Standard: pulsed xenon lamp with average 5 year lifespan Fiber Optic Cables Standard: 600 μm core 1.8 meter fiber optic cables (qty = 2) Data sheet: http://aai.solutions/documents/aa_ds206a_fiberoptics.pdf Sample Medium Sample Introduction Sample Conditioning Analyzer Calibration Reading Verification Human Machine Interface User Interface Data Storage Enclosure Gas or liquid Standard: stainless steel 316L flow cell with application-dependent path length Options in data sheet: http://aai.solutions/documents/aa_ds206a_fiberoptics.pdf Custom design if necessary If possible, analyzer is factory calibrated with certified calibration fluids; no re-calibration required after initial calibration; measurement normalized by Auto Zero Simple verification with samples and self-check diagnostic Applied Analytics standard HMI: industrial controller with touch-screen LCD display Data sheet: http://aai.solutions/documents/aa_ds202a_hmi.pdf ECLIPSE Runtime Software Data sheet: http://aai.solutions/documents/aa_ds203a_eclipse.pdf Solid State Drive Data sheet: http://aai.solutions/documents/aa_ds204a_ssd.pdf Suitcase enclosure made from Ultra High Impact structural copolymer. The case is watertight, crushproof, and dustproof. It uses exclusively 1/4 (6.4 mm) neoprene o-ring and ABS latches with perfect seal. Enclosure Certification NATO codified; MIL C-4150J; IP-67; STANAG 4280; ATA 300 Please inquire for other certifications. Measuring Parameters Repeatabilty Photometric Accuracy Sample Conditions Sample Temperature Sample Pressure (max) Ambient Conditions Analyzer Environment Ambient Temperature ±0.5% of scale ±0.004 AU Standard: -20 to 70 C (-4 to 158 F) Optional: up to 150 C (302 F) with cooling extensions Contact AAI for temperatures above 150 C (302 F) Using immersion probe: 100 bar (1470 psig) Using standard flow cell: 206 bar (3000 psi) Indoor/Outdoor (no shelter required) Standard: 0 to 35 C (32 to 95 F) With optional temperature control: -20 to 55 C (-4 to 131 F) [4]

Revised 25 April 2017 Physical Specifications Dimensions 16.87 H x 20.62 W x 8.12 D (428mm H x 524mm W x 206mm D) Weight Wetted Materials Utility Requirements Electrical Requirements Power Consumption Outputs/Communication Outputs I/O Electronics 25 lbs. (11 kg) Standard: K7 glass, Viton, stainless steel 316L Various custom materials available please inquire. 85 to 264 VAC 47 to 63 Hz 45 watts 1x galvanically isolated 4-20mA analog output per measured analyte 2x digital outputs for fault and SCS control Optional: Modbus TCP/IP; RS-232; RS-485; Fieldbus; Profibus; HART; more Voltage/Current Interface Module (i.e. I/O Board) Data sheet: http://aai.solutions/documents/aa_ds205a_vcim.pdf is a registered trademark of Applied Analytics, Inc. www.aai.solutions Headquarters Applied Analytics, Inc. Burlington, MA sales@aai.solutions North America Sales Applied Analytics North America, Ltd. Houston, TX sales@appliedanalytics.us Asia Pacific Sales Applied Analytics Asia Pte. Ltd. Singapore sales@appliedanalytics.com.sg Middle East Sales Applied Analytics Oil & Gas Operations, L.L.C. Abu Dhabi, UAE sales@appliedanalytics.ae India Sales Applied Analytics (India) Pte. Ltd. Mumbai, India sales@appliedanalytics.in Europe Sales Applied Analytics Europe, AG Genève, Switzerland sales@appliedanalytics.eu Brazil Sales Applied Analytics do Brasil Rio de Janeiro, Brazil vendas@aadbl.com.br 2017 Applied Analytics, Inc. Products or references stated may be trademarks or registered trademarks of their respective owners. All rights reserved. We reserve the right to make technical changes or modify this document without prior notice. Regarding purchase orders, agreed-upon details shall prevail. [5]