FIRE AND SAFETY. Manual Call Points p15-1 Magnetic Door Holders p15-3 Detection Cables p15-4 Portable Signals p15-7 Solar Powered Signals p

Similar documents
Tel: +44(0) Fax: +44(0) /17 LGM Products Ltd. Web: ISO 9001:2015 certified

ALARMLINE ANALOGUE Linear Heat Detection System

Web: LGM Products Ltd.

WLS-T25 Solar Powered Low Intensity Duty & Stand-by Aviation Obstruction Light

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Half-Dome. the Design-Tower. Compact

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

AlarmLine Linear Heat Detector

AlarmLine Addressable Linear Heat Detector

Pilot devices Stacklights Signal beacons

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

INSTRUCTION & SERVICE MANUAL

Alarmline II Analogue Linear Heat Sensor Cable Technical Manual

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

SHO-ME Lights and Sirens

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Hazardous Area Signalling

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

Vehicle Safety & Warning. Product Catalogue (0)

INTRINSICALLY SAFE LIGHTING RANGE

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

ATEX. Wolf Safety Lamp Company. The widest range of portable ATEX lighting approved for use in explosive atmospheres

Light special. Product special

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Celebrating YEARS Manufacturers of Visual & Audible Signalling Devices. NEW Exd

EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures

ATEX. Wolf Safety Lamp Company. Includes NEW LinkEx LED. The widest range of portable ATEX lighting approved for use in explosive atmospheres

DESIGN GUIDELINES. THERMAL building SOLUTIONS

Beacons, Lights & Strobes

DICTATOR Hold-Open Systems for Hazardous Areas

Documentation. Parallel Heating Cable. Type: ELP

Compact, robust crimping tool. suitable for a variety of noninsulated. terminals. Also features a cable cutter and spring return.

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

distributed by Sole Agent in Great China Universky (Jiangsu) Technologies, Inc. Phone: Fax:

Specification/ Data Sheet

The complete conventional fire warning system

DTS Light fittings for explosive atmospheres

Intrusion Outdoor Protection Perimeter

LF-4000 Series Conventional Fire Alarm Control Unit

120W Explosion Proof Signal Light w/ Audible Alarm - C1D1 - (2) Colored LED Lamps - 55 Horn Tones

3000 Series Fan Forced Ceiling Heater Series Commercial Fan Forced Ceiling Heater

Conventional Fire Alarm System 2014 V1.2

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

LINEAR HEAT SENSING DETECTION. System Sensor India 2014

Dräger Polytron 5720 IR Toxic Gas Detection

Safe & hazardous area. Industrial products catalogue

NexLED. Ex e LED BULKHEAD. Features. Standard Specification. International Approvals. NexLED with Exit Sign kit

Intelligent addressable fire alarm control panel

signaling solutions from auer signal

Dräger Flame 2500 (IR3) Flame Detection

Airchime Steam Whistles

Conventional Fire Detection

Explosion Proof Combination Signal db (A) / 5 Joule

LED Ultrastar. trobe beacons

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

EMERGENCY LIGHTING SYSTEM

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

AUDIBLE SIGNALIZATION

WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS

IFP-2.32 Manual 1) DESCRIPTION ICAS FIRE PANEL IFP 2.32

5 yr. Vitalite Rotating Warning Light. Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT

Industries. As a premier global manufacturing company, we believe that great brands are

Dräger Flame 2500 Flame Detection

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input

Dräger Flame 2350 (UV&IR) Flame Detection

Illumination unit For sight glass level indicator Model LGI

Dräger Flame 2100 (UV) Flame Detection

Bulletin 855T 70 mm Control Tower Stack Lights

ATM Lighting sp. z o.o

Dräger Flame 2700 (Multi-IR) Flame Detection

Xenex Conventional Fire Detection & Alarm System

Industrial Horn & LED Strobe Warning System - 12V DC - Weatherproof - NEMA 4X - Class 1 Beacon

Fan Heaters Type VLEx

Alarmline II Digital Linear Heat Sensor Cable Technical Manual

Auer - Signal tower ECO Ø70 mm modular

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

NEMA-4X Series. Certified for Harsh Environment Applications

Dräger Flame 2100 Flame Detection

Ex LED light fittings

Industrial Signalling

Overload relays. General descriptions. Configuration of the front

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger Polytron 8700 IR Detection of flammable gases and vapors

CONTENTS NBM-06 Bell (6") Page 1

DETCON MODEL AV2-C1D2C Hazardous Duty Class I. Div 2, Continuous Tone Alarm Station

Dräger Polytron 8000 Stationary gas detector (EC)

Linear Heat Detection

Dräger Flame 2370 (UV&IR) Flame Detection

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

FlexSQUARE Square shaped beacons

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights

Transcription:

FIRE AND SAFETY Manual Call Points p15-1 Magnetic Door Holders p15-3 Detection Cables p15-4 Portable Signals p15-7 Solar Powered Signals p15-10 Perth (08) 9248 0410 Sydney (02) 9676 1671 Melbourne (03) 9706 4599 15 Adelaide (08) 8347 2499 Brisbane (07) 3274 3327 PAGE 15-0

Manual Call Points FD-108 Break Glass Call Point Single pole change over contact Choice of five colours Supplied with test key Coated glass element Optional transparent flap MBFD108* MBFD108*C MBFD900 MBFD901 MBFD902 Surface Mount Call Point Surface Mount Call Point with Flap Replacement glass (75 x 40mm) Clear polycarbonate flap Test key *Specify colour R = Red, W = White, Y = Yellow, B = Blue, G = Green Switch action: Single pole change over Contact rating (A): 250VAC 10A 24VDC 10A 48VDC 3A IP42 Temp range ( C): -25 to +55 Cable entry: 3 x 20mm Terminal Capacity: 6 x 2.5mm² High impact ABS Dimensions (w x h x d): 86 x 86 x 56mm 200g FD-109 Resettable Call Point One or two change over contacts Available in Red, Yellow or Green Resettable (no glass replacement required) Supplied with lift flap and test key With LED MBFD109*LC1 MBFD109*LC2 MBFD908 Surface Mount Call Point one switch Surface Mount Call Point two switch Test Key *Specify colour 1 R = Red, Y = Yellow, G = Green, W = White 1 Other colours available subject to minimum order requirements Switch action: One or two Single pole change over Contact rating (A): 24VDC 3A Monitoring resistor: 470Ω 1 W (others on request) IP42 Cable entry: 1 x 20mm through back box Terminal Capacity: 3 x 1.5mm² or 6 x 1.5mm² High impact ABS Dimensions (w x h x d): 92 x 92 x 56mm 170g PAGE 15-1

Manual Call Points CX Manual Call Point Weather proof IP66 Available with 240V rated C/O contact or low voltage versions with monitoring resistor PVC coated glass element Supplied with test key Optional transparent flap FUL52000R FUL52005R FUL59000CX FUL59002 N/O contact with monitoring resistor and LED for voltages up to 50V max C/O contact for voltages up to 250VAC Replacement glass (pkt of 10) (75 x 40mm) Clear polycarbonate flap Switch action: Single pole N/O or single C/O contact Contact rating: 0.5A at 50VAC/DC (low voltage version) 3A at 250VAC and 24VDC (Mains version) Monitoring resistor: 470Ω 1 W (others on request) IP66 Temp range ( C): -25 to +70 ABS 220g Key Box Break Glass box for keys Tamper proof housing Replaceable glass ABS housing (colour red) Coated glass LAB10050 LAB20045 Break glass for key box Replacement glass PAGE 15-2

Magnetic Door Holders DH-500 Series Magnetic door holders with 70kg holding force Wall, floor and flush mounting versions Test button (DH-502 and DH-504) Supplied with adjustable armature plate Mounting Dimensions Weight (kg) MBDH501 MBDH502 Basic wall mounting Wall mounting in box 80 x 80 x 45mm 0.72 80 x 80 x 45mm 0.9 MBDH504 Floor mounting 118 x 92 x 120mm 1.46 MBDH505 Flush wall mounting stainless steel front plate 120 x 76 x 28mm 0.7 Voltage: 12-24VDC Current: 100/50mA Holding Force: 70Kg IP41 (from front only on some models) Cable entry: 2 x 20mm Black powder coated steel (flush mount version has stainless steel wall plate) PAGE 15-3

Detection Cables Fixed Temperature Cable Fixed temperature heat detection cables for fire protection 3 temperature points + extra high setting Chemical resistant versions Low cost, easy to install and reliable solution Applications fire detection in cable trays, escalators, warehouses, factories and car parks Full range of installation accessories Conductor resistance: 0.190Ω/m @ 20 C Max. voltage: 42VDC or 30VAC Dielectric withstand (UL): 500VDC Tensile strength: 1700N/mm 2 Min. bend radius: 75mm 1.2kg/100m Fire Fire Control Panel Zone Lead in cable Signaline UCB Interposing Line Resistor Signaline FT Heat Sensing Cable Signaline UCB End of Line Device Alarm Temperature C/ F Maximum Ambient Temperature C/ F Outer Sheath Material Colour Overall Diameter mm LGMFT68 68/155 45/113 PVC Red 3.5 LGMFT68R 68/155 45/113 Chemical and UV resistant Nylon Black 4.5 LGMFT88 88/190 70/158 PVC White 3.5 LGMFT105 105/220 85/185 PVC White 3.5 LGMFT105R 105/220 85/185 Chemical and UV resistant Nylon LGMFT185R 185/365 125/257 Chemical and UV resistant Nylon Note: Supplied in 50m increments, up to 500m per reel. Black 4.5 Red 3.6 Accessories Dimensions Weight (kg) LGMUCB LGMUCBEX LGMAPDL Universal connection 94 x 94 x box 1 57mm Ex e Universal connection box 1, 2 Alarm point distance locator 70 x 80 x 55mm 180 x 130 x 78mm 0.5 0.4 1 Suitable for use as end of line, interposing line unit or junction box. 2 2GD Ex e IIC T5 Ta -40 C to +55 C, @GD Ex tb IIIC T95 C IECEx approval IECExSIR06.0106 1.2 LGMAPDL PAGE 15-4

Detection Cables Analogue Heat Sensing Cable Analogue heat detection cables for fire protection Detects rise in temperature Cable resets once cooled Low cost, easy to install and reliable solution Applications fire detection in cable trays, escalators, warehouses, factories and car parks Full range of installation accessories Conductor resistance: 2Ω/100m @ 20 C Diameter: 2.8mm Temp range ( C): -40 to +70 Alarm temp. range: typical 1 meter alarm range 70 to 125 C 10 meter alarm range 45 to 100 C Tensile strength: 200N Outer Sheath Material Colour Minimum Bend Radius. mm Weight LGMHD01 PVC Red 5 1.6kg/100m LGMHD01R Chemical and UV resistant Nylon Black 18 2.2kg/100m LGMHD01S PVC with stainless steel braid Red 20 3.0kg/100m Note: Supplied in 50m increments, up to 500m per reel. Accessories Dimensions Weight (kg) LGMSKM03 LGMUCB Analogue cable controller, 24VDC, 2 x CO contacts, IP65, EN54 compliant Universal connection box 1 110 x 110 x 65mm 94 x 94 x 57mm 0.27 0.5 1 Suitable for use as end of line, interposing line unit or junction box. PAGE 15-5

Detection Cables Water Detection System Cable detects the presence of water along its length Cable resets once dry Low cost, easy to install and reliable solution Applications include leak detection in data centers, control rooms, museums etc Full range of installation accessories LGMWD003 Water leak detection cable 3.75m LGMWD007 Water leak detection cable 7.5m LGMWD015 LGMWD030 LGMWD100 LGMWDMKM LGMWCB2000 LGMWA01 Water leak detection cable 15m Water leak detection cable 30m Water leak detection cable 100m Water detection monitor WDM-KM with EOL plug Water detection panel CB2000 Non sensing terminating cable 10m Cable 4 core Diameter: 6mm nominal Pre-terminated lengths: 3.75m, 7.5m, 15m, 30m, 100m Non sensing leader cable: 10m Control module WDM-KM Voltage: 12-30VDC Operating current: 10mA (normal operation) 27mA (Alarm relay activated) Alarm output: 1 x NO contact, 1A 30VDC AC1 Fault output: 1 x NC contact, 20mA 48VDC (opens on power loss or cable break) Sensing cable length: 3.75m to 1000m Temp rating ( C): 0 to +50 C Dimensions: 105 x 70 x 30mm Water Detection Panel CB200W monitors up to 8 x WDM-KM control modules Voltage: 230VAC Detection: Up to 8 zones Alarm output: 2 x fully monitored alarm circuits (1 and 2 zone panels) 4 x fully monitored alarm circuits (4 and 8 zone panels) Auxiliary outputs: 1 x NO/NC alarm contact, 1A 30VDC AC1 1 x NO/NC relay output Temp rating ( C): 0 to +50 C Accessories to suit all cable types LGM9001 LGM9002 LGM9003 LGM9004 LGM9005 LGM9006 A clip including cable tie nylon wall mounting cable clip K clip for use with HD cable no screw or cable tie required P clip zinc plated steel cable clip for outdoor use T clip polypropylene cable clip with wall standoff J clip clip to support cables from cable trays Edge clip cable clip to support cable from steelwork PAGE 15-6

Portable Signaling Porta-lamp Battery powered xenon strobe Available with amber or red lens Weatherproof Magnetic mounting UECBBX* *Specify colour A = Amber, R = Red Porta-Lamp Battery Powered Xenon Beacon Flash Rate: 60fpm ±5 Lamp Type: 0.5J Xenon Batteries: 2 x D cells (not included) Autonomy: Approx. 30 hours (dependent on battery quality) Protection rating: IP55 polypropylene body, polycarbonate lens Dimensions (Ø x h): 105 x 135mm 0.58Kg Emergency Flare Battery powered LED emergency light Rechargeable from 12V vehicle socket or with 230V charger (included) Magnetic mounting 9 flash patterns Available in 6 colours Waterproof and floats Available in 6 pack case with charger Battery: Battery life: Light Source: Flash rate: Lithium Ion 6 to 35 hours depending on flash pattern 16 x LED s 60fpm IP67 TPE and PC Weight (kg) KAM1EF1* LED Flare with charger 0.285 KAM1EF6* 6 pack with charger single colour 3.10 KAM1EF6RB 6 pack with charger 3 red + 3 Blue 3.10 *Specify colour A = Amber, B = Blue, G = Green, R = Red, W = White, Y = Yellow PAGE 15-7

Portable Signaling EcoBlast Rechargeable air horn High sound output up to 115dB Can be refilled from any compressed air source Supplied with holster Operating pressure: Sound output: Autonomy: Dimensions (l x h x w): Min 5psi to Max 150psi Max 115dB @ 1m Approx. 30 seconds continuous blast when fully charged ABS (Horn), Aluminium (Canister) 190 x 200 x 75mm Weight (g) AIZ002 EcoBlast blister pack with pump 250 EcoBlast PRO Rechargeable air horn High sound output up to 115dB Rechargeable from air compressor or bike pump etc Pressure fuel gauge fitted Supplied with carry strap Optional bracket for wall mounting Operating pressure: Sound output: Autonomy: Dimensions (l x h x w): Min 5psi to Max 90psi Max 115dB @ 1m Approx. 200 blasts per charge ABS 280 x 230 x 160mm Weight (kg) AIZ010 EcoBlast Pro 0.95 AIZ900 Wall mounting bracket 0.7 Lalizas Air Horn Pressure canister powered air horn. High sound output Replacement canisters available Sound output: Propellant: Dimensions (l x h x w): 120dB @ 1m Hydrocarbon (non CFC) 380ml ABS horn, metal canister 170 x 220 x 55mm 290g Weight (kg) LALPA045PN Lalizas air horn 0.29 LALPA0451N Replacement propellant cannister 0.18 PAGE 15-8

Portable Signaling LK100 Hand Operated Siren Hand wound siren with output up to 108dB Heavy duty aluminium or lightweight plastic versions Supplied with carry bag Sound output: Frequency: 108dB @ 1m 550Hz nominal (depends on speed of rotation) Aluminium or ABS Weight (kg) LK100 Hand wound siren -aluminium 1.2 LK100P Hand wound siren - ABS 0.6 LK120 Hand Operated Siren Hand wound siren with output up to 120dB Heavy duty aluminium construction Portable with stand Sound output: Frequency: 120dB @ 1m 600Hz nominal (depends on speed of rotation) Aluminium siren with steel tube stand Weight (kg) LK120 Hand wound siren 11 STM Megaphone Choice of outputs 10 or 15W Public address and siren/whistle sound Separate microphone Power Sound Max. Range Batteries* Dimensions Weight (kg) MXSTM210W 10W whistle 320m 6 x C cells 350 x 200mm 1.5 MXSTM315S 15W Siren 500m 8 x C cells 355 x 235mm 1.6 * Batteries not included PAGE 15-9

Solar Powered Signals H-906 Hazard Marker High output LED solar powered signal Combined flasher and reflector Bidirectional light output Operates at night only Pole mounting Maintenance free Light Colour Weight (kg) KAIH906WR Red 0.68 KAIH906WY Yellow 0.68 Flash Rate: 150fpm ±30 Lamp Type: 6 x 8mm high output LED (in each direction) Batteries: Ni-cd Battery life: Approx. 3 years Autonomy: Approx. 24 hours (dependent on length and strength of sunshine) IP65 Aluminium alloy body, polycarbonate lens Mounting: 30mm pole mount H-931 Hazard Marker High output LED solar powered signal High visibility Unidirectional Operates at night only Pole mounting Maintenance free Light Colour Weight (kg) KAIH931R Red 1.8 Flash Rate: 120fpm ±20 Lamp Type: 8 x 5mm high output LED Batteries: Ni-cd Battery life: Approx. 3 years Autonomy: Up to 36 hours (dependent on length and strength of sunshine) IP65 Polypropylene body, polycarbonate lens Mounting: Pole mount (supplied with adjustable clamps) KAIH931Y Yellow 1.8 PAGE 15-10

Solar Powered Signals H-962 Traffic Signal Light High output LED solar powered signal High visibility Unidirectional Pole mounting Operates day and night Maintenance free Light Colour Weight (kg) KAIH962R Red 8 KAIH962Y Yellow 8 Flash rate: 60fpm ±10 Lamp type: 120 x 5mm high output LED Batteries: Sealed Lead-Acid IP65 Powder coated aluminium alloy housing Mounting: Supplied with mounting brackets 8Kg H-932 Pavement Marker High output LED solar powered signal High visibility Bidirectional (except white versions) Operates at night only Maintenance free Light Colour/Direction Weight (kg) KAIH932WR Red/Red 0.36 KAIH932WA Yellow/yellow 0.36 Flash rate: 300fpm ±60 Lamp type: 3 x 5mm high output LED (in each direction, except white versions) Batteries: Ni-cd Autonomy: Up to 24 hours (dependent on length and strength of sunshine) IP66 Aluminium and polycarbonate Mounting: Surface mount KAIH932WAR Yellow/Red 0.36 KAIH932SW White (steady / flashing) 0.36 KAIH932BSW White / (steady) 0.36 PAGE 15-11